Search NASA⌕ Search

SEARCH · Search NASA

Results for “effective volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Aerial and satellite photography - A valuable tool for water quality investigations

An investigation of surface, volume, and bottom effects in Lake Superior is conducted. The objective of the reported study is the development of a reliable technique for the monitoring and the quantification of the water quality parameters associated with volume reflectance. Basic relationships are discussed together with details concerning the equipment used in the studies, the water quality on the basis of aerial photos and satellite imagery, and the effects of oil on sky-light reflection.

Scherz, J. P.↗

Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

Convertino, Victor A.↗

Integrated mechanics for the passive damping of polymer-matrix composites and composite structures

Some recent developments on integrated damping mechanics for unidirectional composites, laminates, and composite structures are reviewed. Simplified damping micromechanics relate the damping of on-axis and off-axis composites to constituent properties, fiber volume ratio, fiber orientation, temperature, and moisture. Laminate and structural damping mechanics for thin composites are summarized. Discrete layer damping mechanics for thick laminates, including the effects of interlaminar shear damping, are developed and semianalytical predictions of modal damping in thick simply supported specialty composite plates are presented. Applications show the advantages of the unified mechanics, and illustrate the effect of fiber volume ratio, fiber orientation, structural geometry, and temperature on the damping. Additional damping properties for composite plates of various laminations, aspect ratios, fiber content, and temperature illustrate the merits and ranges of applicability of each theory (thin or thick laminates).

Saravanos, D. A.↗

Seasonal and Long‐Term Groundwater Unloading in the Central Valley Modifies Crustal Stress

Abstract Changes in terrestrial water content cause elastic deformation of the Earth's crust. This deformation is thought to play a role in modulating crustal stress and seismicity in regions where large water storage fluctuations occur. Groundwater is an important component of total water storage change in California, helping to drive annual water storage fluctuations and loss during periods of drought. Here we use direct estimates of groundwater volume loss during the 2007–2010 drought in California's Central Valley obtained from high resolution Interferometric Synthetic Aperture Radar‐based vertical land motion data to investigate the effect of groundwater volume change on the evolution of the stress field. We show that GPS‐derived elastic load models may not capture the contribution of groundwater to terrestrial water loading, resulting in an underestimation of nontectonic crustal stress change. We find that groundwater unloading during the drought causes Coulomb stress change of up to 5.5 kPa and seasonal fluctuations of up to 2.6 kPa at seismogenic depth. We find that faults near the Valley show the largest stress change and the San Andreas fault experiences only ~40 Pa of Coulomb stress change over the course of a year from groundwater storage change. Annual Coulomb stress change peaks dominantly in the fall, when the groundwater level is low; however, some faults experience peak stress in the spring when groundwater levels are higher. Additionally, we find that periods of increased stress correlate with higher than average seismic moment release but are not correlated with an increase in the number of earthquakes. This indicates groundwater loading likely contributes to nontectonic loading of faults, especially near the Valley edge, but is not a dominant factor in modulation of seismicity in California because the amplitude of stress change declines rapidly with distance from the Valley. By carefully quantifying and spatially locating groundwater fluctuations, we will improve our understanding of what drives nontectonic stress and forces that modulate seismicity in California.

58 GEOSCIENCES↗

Silicon solar cell development and radiation effects study for low temperature and low illumination intensity operation, volume 2

The results are presented of a study to determine the effect of in-situ proton irradiation upon low temperature, low intensity performance of several cell types. The cell types were selected in an attempt to distinguish variations in temperature-dependent radiation resistance which could be attributed to the n-p or p-n structure, diffused or implanted junctions, crucible grown or float-zone type base material, and high or low base resistivity. The results indicate that while expected variations of performance occur at room temperature, all cell types degrade more or less similarly at lower temperatures with normalized degradation becoming increasingly rapid as temperature is reduced. Recommendations for an optimized cell for Jupiter probe use are included along with a definition of the testing required on these cells to insure good performance characteristics.

Kirkpatrick, A. R.↗

Constraints on PSC Particle Microphysics Derived From Lidar Observations

Based on extensive T-matrix computations of light scattering by polydispersions of randomly oriented, rotationally symmetric nonspherical particles, we analyze existing lidar observations of polar stratospheric clouds (PSCs) and derive several constraints on PSC particle microphysical properties. We show that sharp-edged nonspherical particles (finite circular cylinders) exhibit less variability of lidar backscattering characteristics with particle size and aspect ratio than particles with smooth surfaces (spheroids). For PSC particles significantly smaller than the wavelength, the backscatter color index Alpha and the depolarization color index Beta are essentially shape-independent. Observations for type Ia PSCs can be reproduced by spheroids with aspect ratios larger than 1.2, oblate cylinders with diameter-to-length ratios greater than 1.6, and prolate cylinders with length-to-diameter ratios greater than 1.4. The effective equal-volume-sphere radius for type la PSCs is about 0.8 microns or larger. Type Ib PSCs are likely to be composed of spheres or nearly spherical particles with effective radii smaller than 0.8 microns. Observations for type II PSCs are consistent with large ice crystals (effective radius greater than 1 micron modeled as cylinders or prolate spheroids.

Liu, Li↗

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

Review, Tutorial↗

Effective path length corrections in beam-beam scattering experiments

The effect of the change of scattering geometry with scattering angle in beam-beam experiments is investigated. Atomic (molecular) target distributions associated with static gas, orifice, tube, capillary array (with and without further collimation), and jet sources have been considered in model calculations for a number of commonly used electron scattering geometries. The relationship between scattering intensity, cross section, and the geometrical integral called 'effective path length' is derived. Volume correction factors (the reciprocal of effective path length) have been calculated for sample cases to illustrate the effect of various beam and scattering geometry characteristics. The validity of the model calculation has been experimentally verified. Most of the commonly used scattering geometries require significant correction of the scattering intensity distributions, but with proper planning scattering geometries can be designed such that the intensity and the cross section angular distribution are identical within 1%.

Brinkmann, R. T.↗

Data volume reduction for single-look polarimetric imaging radar data

An 8-b quantization scheme to reduce the data volume for single-look complex scattering matrix data measured by polarimetric imaging radar systems is described. The scattering matrices are not symmetrized before compression, thereby retaining information about background noise and system effects. The data volume is reduced by a factor of 3.2. It is shown, with measured data, that the signal to quantization noise ratio for the compression scheme is more than 35 dB for the cross-polarized channels, and more than 45 dB for the copolarized channels.

Van Zyl, Jakob J.↗

Rethinking the Role of Financial Transmission Rights in Wind-Rich Electricity Markets in the Central U.S.

Transmission congestion can cause a divergence between wholesale power prices at the individual pricing nodes where power is generated and the more-liquid trading hubs where that power is often delivered and sold. This nodal price difference is commonly referred to as the “locational basis” (or just “basis”). Because the basis varies over time, it can—if not hedged—unpredictably affect a wind plant’s revenue and/or value, which increases investor risk and potentially slows deployment. We find wind plants typically face a larger and more-negative basis than do thermal generators, and hence are more-negatively impacted by congestion. Moreover, while most thermal generators can effectively hedge basis risk by purchasing conventional fixed-volume financial transmission rights (FTRs), these fixed-volume FTRs do not effectively hedge basis risk for variable wind generation. More-effective hedging mechanisms may be required to support those generators most-impacted by congestion, and to promote continued investment in variable generation resources in congested markets.

17 WIND ENERGY↗

Thermal-capillary analysis of Czochralski and liquid encapsulated Czochralski crystal growth

Results are presented from finite element analysis of the Czochralski (CZ) and Liquid Encapsulated Czochralski (LEC) crystal growth processes based on a thermal-capillary model which governs the heat transfer in the system simultaneously with setting the shapes of the melt/solid interface, the melt and encapsulant menisci, and the radius of a steadily growing crystal. Calculations are performed for the small-scale growth of silicon (CZ) and gallium arsenide (LEC). The effects of melt volume and crucible position relative to the heater on the radius of the crystal and the shape of the melt/solid interface are predicted for the CZ system, and the importance of including an accurate representation of the melt meniscus for modeling the process is demonstrated. The additional effect of an encapsulant layer on heat transfer is treated for the LEC method for the cases of totally transparent and opaque encapsulant. The responses of these LEC prototype systems are examined for changes in pull rate and encapsulant volume.

Derby, J. J.↗

Initial ASME code rule analysis on Simple and Full assessment

ASME & ASTM codes present simple and full assessment methodologies to qualify nuclear grade graphite components. This report explains the theory behind the statistical portion of the codes and describes the issues discussed in a 2020 workshop in the simple assessment, as well as the full assessment. The methodology for the full assessment was developed by Hindley []. He used a validation methodology to match the experimental average failure load of test specimens from several geometries to the calculated 50% POF load to tune the grouping criteria parameters based on an RMSE penalty function. The grouping criteria consists of a minimum volume to satisfy the weakest link theory of the Weibull distribution and a minimum stress range parameter. Hindley’s work found a minimum link volume of 10 times the grain size and a stress range parameter of 7% [satisfy the validation requirements. Several studies found that the link volume of 10 times the grain size was not satisfactory for the volume grouping criteria for graphite grades with fine grains. ASME 2021 code adopted a new volume grouping criteria based on fracture toughness for calculation of the process zone volume. However, errors were found in the ASME 2021 code process zone volume equation and the question is now open as to what volume grouping criteria is satisfactory. This report presents results from sensitivity studies that were done to evaluate the volume grouping criteria effect on the full assessment POF. This report also presents results from sensitivity studies on other aspects of the code that affect the POF, the mesh size and the choice of the Weibull threshold parameter. All three sensitivity studies: the volume grouping criteria, the mesh size, and the threshold parameter choice are found to affect the component qualification decision for components of structural reliability class 1 (SRC-1). The sensitivity analysis results are presented in the body of the report for NBG-18, which is the same grade of graphite as Hindley used in his thesis. Results from NBG-17, IG-110, 2114, and PCEA are presented in the Appendix. For NBG-18, it was found that increasing the threshold increases the POF, finer meshes result in higher POFs, and that smaller link volume requirements lead to higher POFs (which is inconsistent with Hindley’s findings). This report proposes a new validation study similar to Hindley’s []. The purpose of the new validation study is to tune the threshold, mesh size and grouping criteria based on results from multiple grades of graphite, including finer grain graphites T220 (1-3 microns) and NG-CT-50 (5 microns). The test specimens will be broken at 3 labs, such that we can measure between lab measurement variability, with at least 5 test specimens per lab such that the within lab uncertainty can also be measured. Hindley’s validation method tried matching the average experimental load with the median. The future study will attempt to match failures at lower percentiles, which would be closer to the SRC POF limit. We are currently looking into what geometries make sense and the best method to measure multi-axial stress states. These design decisions are still being set.

36 MATERIALS SCIENCE↗

Longitudinal coherence and short-term wind speed prediction based on a nacelle-mounted Doppler lidar

The spatial structure of turbulence in atmospheric boundary layer flows is highly relevant to wind energy. In particular, wind turbine control strategies based on inflow preview measurements require knowledge of the longitudinal evolution of turbulent flow as it approaches the rotor. These upstream measurements are usually obtained with nacelle-mounted wind lidars. In contrast to traditional in situ anemometry, lidars collect measurements within a probe volume which varies in size depending on the technology of the commercial system being used. Here, we address two issues related to the use of wind lidar to measure the incoming flow to a wind turbine: (i) whether existing longitudinal coherence models can be used to predict flow at the rotor, based on measurements performed at a distance away from the rotor; and (ii) what effect probe-volume averaging has on the inflow predictions. These two questions are critical to the design and implementation of robust wind turbine control strategies. To address these questions, we perform field measurements and large-eddy simulations to determine which incoming flow structures can be readily predicted with existing coherence models, and which require additional corrections to account for lidar volumetric averaging effects. Results reveal that the wind turbine induction zone has a negligible impact on the longitudinal coherence and first-order turbulence quantities, such as the standard deviation of velocity fluctuations. However, the phase of the signal, from which advection time periods of the turbulent structures are derived, is affected by the rotor blockage effect.

17 WIND ENERGY↗

Studies of single-mode injection lasers and of quaternary materials. Volume 2: Measurement of electro-optic effects in InGaAsP junction waveguides

Both the linear electro-optic (Pockel's) effect and electroabsorption (Franz-Keldysh effect) in waveguiding junctions of InGaAsP were measured. The electro-optic coefficient is found to be 0.1-0.14x10 to the -12 power m/V at lambda = 1.54 - 1.65 micrometers. Possibly this is the first reported measurement of the electro-optic coefficient for InGaAsP. The value found for the electroabsorption is on the order of 7x10 to the -4 power cm to the -1 power/(V/cm) or approximately 100 cm/1 for fields of 200,000 V/cm at lambda 1.3 micrometers. All measurements were made on a quaternary film with a bandgap wavelength of 1.23 micrometers. Because of the rapid commercial introduction of quaternary lasers, LEDs, and detectors to take advantage of large optical fiber bandwidths and low losses in the 1.2- to 1.7- micrometer region, these measurements are significant in providing some of the basic physical constants needed to design modulators and switches capable of operating at microwave frequencies in this wavelength region.

Hammer, J. M.↗