Search NASA⌕ Search

SEARCH · Search NASA

Results for “high field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The boundary layer on compressor cascade blades

The characteristics of the flow field about highly loaded turbocompressor blades in a cascade wind tunnel were investigated. Experimental tests were conducted at chord Reynolds number (R sub c) near 500,000. A laser Doppler anemometer was employed in flow velocity measurement. Suction surface mean velocity and turbulence intensity profiles at a single incidence angle are presented. These data contribute to further understanding of two-dimensional boundary layer profiles, points of separation, and transition zones for turbomachine blades, and concomitantly, to compressor cascade predictive models.

Deutsch, S.↗

Helicopter Airborne Laser Positioning System (HALPS)

The theory of operation, configuration, laboratory, and ground test results obtained with a helicopter airborne laser positioning system developed by Princeton University is presented. Unfortunately, due to time constraints, flight data could not be completed for presentation at this time. The system measures the relative position between two aircraft in three dimensions using two orthogonal fan-shaped laser beams sweeping across an array of four detectors. Specifically, the system calculates the relative range, elevation, and azimuth between an observation aircraft and a test helicopter with a high degree of accuracy. The detector array provides a wide field of view in the presence of solar interference due to compound parabolic concentrators and spectral filtering of the detector pulses. The detected pulses and their associated time delays are processed by the electronics and are sent as position errors to the helicopter pilot who repositions the aircraft as part of the closed loop system. Accuracies obtained in the laboratory at a range of 80 ft in the absence of sunlight were + or - 1 deg in elevation; +0.5 to -1.5 deg in azimuth; +0.5 to -1.0 ft in range; while elevation varied from 0 to +28 deg and the azimuth varied from 0 to + or - 45 deg. Accuracies in sunlight were approximately 40 deg (+ or - 20 deg) in direct sunlight.

Eppel, Joseph C.↗

Helicopter Airborne Laser Positioning System (HALPS)

The theory of operation, configuration, laboratory, and ground test results obtained with an HALPS developed by Princeton University is presented. The HALPS measures the relative position between two aircraft in three dimensions using two orthogonal fan-shaped laser beams sweeping across an array of four detectors. Specifically, the HALPS calculates the relative range, elevation, and azimuth between an observation aircraft and a test helicopter with a high degree of accuracy. The detector array provides a wide field of view in the presence of solar interference due to compound parabolic concentrators and spectral filtering of the detector pulses. The detected pulses and their associated time delays are processed by the electronics and are sent as position errors to the helicopter pilot who repositions the aircraft as part of the closed loop system. Accuracies obtained in the laboratory at a range of 80 ft in the absence of sunlight were + or - 1 deg in elevation; +0.5 to -1.5 deg in azimuth; +0.5 to -1.0 ft in range; while elevation varied from 0 to +28 deg and the azimuth varied from 0 to + or - 45 deg. Accuracies in sunlight were approximately 40 deg (+ or - 20 deg) in direct sunlight.

Eppel, Joseph C.↗

Airborne rotary air separator study

Several air breathing propulsion concepts for future earth-to-orbit transport vehicles utilize air collection and enrichment, and subsequent storage of liquid oxygen for later use in the vehicle emission. Work performed during the 1960's established the feasibility of substantially reducing weight and volume of a distillation type air separator system by operating the distillation elements in high 'g' fields obtained by rotating the separator assembly. This contract studied the capability test and hydraulic behavior of a novel structured or ordered distillation packing in a rotating device using air and water. Pressure drop and flood points were measured for different air and water flow rates in gravitational fields of up to 700 g. Behavior of the packing follows the correlations previously derived from tests at normal gravity. The novel ordered packing can take the place of trays in a rotating air separation column with the promise of substantial reduction in pressure drop, volume, and system weight. The results obtained in the program are used to predict design and performance of rotary separators for air collection and enrichment systems of interest for past and present concepts of air breathing propulsion (single or two-stage to orbit) systems.

Acharya, A.↗

Simulation of Rotor Blade Element Turbulence

A turbulence model has been developed for blade-element helicopter simulation. This model, called Simulation of Rotor Blade Element Turbulence (SORBET), uses an innovative temporal and geometrical distribution algorithm that preserves the statistical characteristics of the turbulence spectra over the rotor disc, while providing velocity components in real time to each of five blade-element stations along each of four blades. An initial investigation of SORBET has been performed using a piloted, motion-based simulation of the Sikorsky UH60A Black Hawk. Although only the vertical component of stochastic turbulence was used in this investigation, vertical turbulence components induce vehicle responses in all translational and rotational degrees of freedom of the helicopter. The single-degree-of-freedom configuration of SORBET was compared to a conventional full 6-degrees-of-freedom baseline configuration, where translational velocity inputs are superimposed at the vehicle center of gravity, and rotational velocity inputs are created from filters that approximate the immersion rate into the turbulent field. For high-speed flight the vehicle responses were satisfactory for both models. Test pilots could not distinguish differences between the baseline configuration and SORBET. In low-speed flight the baseline configuration received criticism for its high frequency content, whereas the SORBET model elicited favorable pilot opinion. For this helicopter, which has fully articulated blades, results from SORBET show that vehicle responses to turbulent blade-station disturbances are severely attenuated. This is corroborated by in-flight observation of the rotor tip path plane as compared to vehicle responses.

McFarland, R. E.↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Bench-Scale Testing of a High Efficiency, Ultra-Compact Process for Pre-Combustion CO 2 Capture (Final Report)

The overarching objective of this bench-scale study is to field-validate the technical feasibility of a membrane- and adsorption-enhanced water gas shift (WGS) reaction process that employs a carbon molecular sieve (CMS) membrane reactor (MR) followed by an adsorption reactor (AR) for pre-combustion CO 2 capture while demonstrating progress towards achievement of the overall performance goals of CO 2 capture with 95% CO 2 purity at a cost of electricity (COE) of 30% less than the baseline capture approaches. The main goal of this bench-scale project is to advance the proposed MR-AR transformative CO 2 capture technology to a sufficient maturity level so that our present industrial partners (M&PT and Worley) can potentially adapt the technology for further small pilot-scale testing. The project began at TRL 4, as the system prototype had already been validated in the laboratory on simulated syngas (as part of project DE-FE0026423). The project ended at TRL 5, via scaling-up of the prototype system and testing it on actual syngas at a host site (CAER at the University of Kentucky (UKy)). The project was carried-out in two different phases: In Phase I (during BP1 of the project), the team designed, constructed, and assembled the bench-scale experimental MR-AR system, prepared the membranes, adsorbents, and catalysts, tested the bench-scale unit with simulated syngas to validate functionality, and prepared a preliminary TEA of the technology. In Phase II (during BP2 of the project), the team installed the unit at the test site at the UKy site and completed all utility connections and hookups, field-tested the novel MR-AR process in the bench-scale system using real syngas, collected and analyzed experimental data, and completed a detailed TEA of the technology. A key aim of the project was to identify and address the technical and process risks and to generate information to advance the technology to the next stage of development. All project milestones and success criteria were met. Specifically, the team: (i) designed, constructed and assembled a bench scale system that handled 1 – 5 scfm syngas and tested its functionality with simulated syngas; (ii) prepared high performance CMS membrane tubes (ID: 3.5 mm, OD: 5.7 mm, 30” long) that meet the target H 2 permeance ( > 1 m 3 /(m 2 .hr.bar) or (> 370.3 GPU)) and a target H 2 /CO selectivity >80 at the relevant temperature (up to 300oC) and pressure conditions (up to 25 bar) with a <10% decline in performance over each 250 hr. testing period (iii) procured commercial sour-shift catalyst in sufficient quantity and prepared up to 10 kg of pelletized adsorbent for use at relevant conditions (250oC 2.5wt.% and target sorbent attrition rate < 0.2; (iv) installed the bench-scale unit at the test site (UKy) and tested the MR-AR technology using real syngas for over 250 hr. for both static and flow experiments; (v) updated the TEA analysis based on bench-scale data and met CO 2 capture goals of 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. The CMS membranes, HTC adsorbents and catalysts employed all exhibited very robust and stable performance during the long-term run (over a >250 hr live syngas run). Furthermore, the proposed MR-AR IGCC system achieved a LCOE with a N 2 sale price of $\$$ 30/ton, with N 2 compression (no N 2 compression) of 101.2 $\$$/MWh (95.3 $\$$/MWh), which represents a 29.8% (33.9%) LCOE reduction in the baseline IGCC with carbon capture of 144.2 $\$$/MWh. The proposed MR-AR IGCC delivers a CO 2 capture cost of 44.8 $\$$/tonne (39.9 $\$$/tonne) vs 98.1 $\$$/tonne of the baseline capture case and a net power production of 586 MWe (623 MWe) vs 556 MWe of the baseline capture case.

01 COAL, LIGNITE, AND PEAT↗

Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

Littell, Justin D.↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis

Modern microelectronics life-cycle and supply chain ecosystem bring multiple untrusted entities, which can compromise their integrity. A major integrity issue of microelectronics stems from piracy of intellectual properties (IP) and counterfeiting, which causes significant revenue loss to the semiconductor manufacturers. Further, these components often lead to compromised functionality, reliability, security, and safety of an electronic system. This paper presents secure information transmission and probing methods for verifying the integrity of digital integrated circuit (ICs) based on their electromagnetic (EM) near-field emissions and thereby protecting systems against counterfeit components. The proposed method has been tested on both high-level instructions executed by microprocessors or Systems-on-Chip (serving as examples of software), and also logic circuits within FPGA fabrics and ASICs (serving as examples of hardware). The authentication information required by each digital system is generated using a pseudo-random number generator circuit and securely transmitted via near-field magnetic emissions. The authorized party can probe these emissions using a near-field probe, process the acquired signals to improve the signal-to-noise ratio (SNR), and then recover the secure information through matched filtering. Experimental results from commercial SoCs are used to demonstrate the proposed technique. Methods for reducing EM interference during integrity verification of both FPGAs and ASICs are also described.

47 OTHER INSTRUMENTATION↗

Endwall Heat Transfer Measurements in a Transonic Turbine Cascade

Turbine blade endwall heat transfer measurements are given for a range of Reynolds and Mach numbers. Data were obtained for Reynolds numbers based on inlet conditions of 0.5 and 1.0 x 106, for isentropic exit Mach numbers of 1.0 and 1.3, and for freestream turbulence intensities of 0.25% and 7.0%. Tests were conducted in a linear cascade at the NASA Lewis Transonic Turbine Blade Cascade Facility. The test article was a turbine rotor with 136' of turning and an axial chord of 12.7 cm. The large scale allowed for very detailed measurements of both flow field and surface phenomena. The intent of the work is to provide benchmark quality data for computational fluid dynamics (CFD) code and model verification. The flow field in the cascade is highly three-dimensional as a result of thick boundary layers at the test section inlet. Endwall heat transfer data were obtained using a steady-state liquid crystal technique.

Giel, P. W.↗

Formation and dissociation of shear-induced high-energy dislocations: insight from molecular dynamics simulations

Solid-phase processing (SPP) allows one to create complex microstructures, not achievable via thermal processing alone. The resulting structures exhibit a rich palette of defects, both thermal and non-thermal, including defect substructures, such as dislocation networks. It is essential to understand the mechanisms of deformation and defect structure formation to guide SPP towards achieving desired microstructures and material properties. In this study, large-scale molecular dynamics simulations are used to investigate the effects of inhomogeneous strain distribution, that mimics deformation conditions of tribological tests, on the evolution of defects under severe shear deformation in polycrystalline Al. Analysis of defect nucleation and reaction pathways reveals that strong geometric constraints suppress the nucleation and slide of low energy dislocation 1/2$\langle110\rangle${111} but promote the nucleation and slide of high energy dislocations, such as [$1\bar1$0] (001) and 1/2 [$1\bar1$$\bar2$]($1\bar1$1). Further, a rough contact surface, characteristic to tribological tests, imposes an inhomogeneous stress field leading to inhomogeneous defect substructures due to location-dependent activation of slip systems. The results suggest that high-energy dislocations can dominate the evolution of grain structures in highly constrained environments, which should be considered in modeling plastic deformation and grain refinement during SPP.

42 ENGINEERING↗

FOCAL Campaign I: Advanced Wind Turbine Control Strategies

Campaign I of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aims to generate a dataset enabling the validation of aerodynamic performance of a scaled turbine mounted on a rigid tower in a fixed condition. The turbine considered in the FOCAL testing campaigns is the IEA-Wind 15MW Reference Wind Turbine. This scaled model is capable of simulating advanced blade-pitch control strategies in a high-quality wind field. The turbine is fully instrumented to record a variety of parameters in real time such as structural loads and dynamics. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Constant wind and blade-pitch with varying rotor speeds LC 2.X - Constant wind and rotor speed with varying blade-pitch LC 3.X - Varying wind with active closed-loop control Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign I: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine. UMaine ASCC Report Number 23-40-1183. Details on the results of the verification and validation are found in the following reference: Mendoza, Nicole et al., "Verification and Validation of Model-Scale Turbine Performance and Control for the IEA Wind 15 MW Reference Wind Turbine," Energies, vol. 15, no. 20, 2022, https://doi.org/10.3390/en15207649.

17 WIND ENERGY↗

A Computationally Efficient Linear Semi-Lagrangian Scheme for the Advection of Microphysical Variables in Cloud-Resolving Models

An efficient semi-Lagrangian (SL) numerical scheme for the advection of positive-definite microphysical variables in cloud-resolving models is proposed. The scheme is a linear combination of SL schemes of the first and second order. The proposed scheme is compared with two high-order, monotonic, nonlinear Eulerian schemes, in two 2D tests. In the first test, advection of a positive scalar field with large gradients is performed within complicated idealized steering flows. In the second test, a hail storm is simulated using the 2D Hebrew University Cloud Model, describing the interactions between 15 size distributions of different microphysical quantities (each distribution is described by 43 mass bins). The proposed scheme is computationally efficient, has a low numerical diffusion and a high level of mass conservation accuracy, and preserves the sum of multiple advected variables as well as the linear relationships between the advected scalar variables. Although the proposed SL scheme is not exactly positive definite, the negative values and their number, which may appear only in the case of very strong gradients, are negligible. The scheme produces results similar to those of nonlinear Eulerian advection schemes while reducing computation time by approximately a factor of 10.

54 ENVIRONMENTAL SCIENCES↗

Multiphysics Simulations of Thermal Shock Testing of Nanofibrous High Power Targets

Increase of primary beam power for neutrino beam-lines leads to a reduced lifespan for production targets. New concepts for robust targets are emerging from the field of High Power Targetry (HPT); one idea being investigated by the HPT R&D Group at Fermilab is an electrospun nanofiber target. As part of their evaluation, samples with different densities were sent to the HiRadMat facility at CERN for thermal shock tests. The samples with the higher density, irradiated under a high intensity beam pulse, exhibit major damage at the impact site whereas those with the lower density show no apparent damage. The exact cause of this failure was unclear at the time. In this paper, we present the results of multiphysics simulations of the thermal shock experienced by the nanofiber targets that suggest the failure originates from the reduced permeability of the high density sample to air flow. The air present in the porous target expands due to heating from the beam, but is unable to flow freely in the high density sample, resulting in a larger back pressure that blows apart the nanofiber mat. We close with a discussion on how to further validate this hypothesis.

43 PARTICLE ACCELERATORS↗

Upgraded Near-Field Antenna-Testing System

Upgraded system for near-field testing of large microwave antenna built around commercial automated network analyzer (HP8510) designed for measurement and characterization of microwave circuits and components. Contains highly capable microwave receiver also suitable for far-field and radar-cross-section measurements. Receiver operates in fast-data-acquisition mode at rate of one new data point every millisecond without averaging. Also operates with greater sensitivity by use of averaging feature at time penalty of 0.2 ms per average. Time-domain option added to analyzer enables it to perform time-domain reflectometry.

Kunath, Richard R.↗

Benchmark Testing of the Largest Titanium Aluminide Sheet Subelement Conducted

To evaluate wrought titanium aluminide (gamma TiAl) as a viable candidate material for the High-Speed Civil Transport (HSCT) exhaust nozzle, an international team led by the NASA Glenn Research Center at Lewis Field successfully fabricated and tested the largest gamma TiAl sheet structure ever manufactured. The gamma TiAl sheet structure, a 56-percent subscale divergent flap subelement, was fabricated for benchmark testing in three-point bending. Overall, the subelement was 84-cm (33-in.) long by 13-cm (5-in.) wide by 8-cm (3-in.) deep. Incorporated into the subelement were features that might be used in the fabrication of a full-scale divergent flap. These features include the use of: (1) gamma TiAl shear clips to join together sections of corrugations, (2) multiple gamma TiAl face sheets, (3) double hot-formed gamma TiAl corrugations, and (4) brazed joints. The structural integrity of the gamma TiAl sheet subelement was evaluated by conducting a room-temperature three-point static bend test.

Bartolotta, Paul A.↗