Search NASA⌕ Search

DOE OSTI · 1997930

Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis

Abstract

Modern microelectronics life-cycle and supply chain ecosystem bring multiple untrusted entities, which can compromise their integrity. A major integrity issue of microelectronics stems from piracy of intellectual properties (IP) and counterfeiting, which causes significant revenue loss to the semiconductor manufacturers. Further, these components often lead to compromised functionality, reliability, security, and safety of an electronic system. This paper presents secure information transmission and probing methods for verifying the integrity of digital integrated circuit (ICs) based on their electromagnetic (EM) near-field emissions and thereby protecting systems against counterfeit components. The proposed method has been tested on both high-level instructions executed by microprocessors or Systems-on-Chip (serving as examples of software), and also logic circuits within FPGA fabrics and ASICs (serving as examples of hardware). The authentication information required by each digital system is generated using a pseudo-random number generator circuit and securely transmitted via near-field magnetic emissions. The authorized party can probe these emissions using a near-field probe, process the acquired signals to improve the signal-to-noise ratio (SNR), and then recover the secure information through matched filtering. Experimental results from commercial SoCs are used to demonstrate the proposed technique. Methods for reducing EM interference during integrity verification of both FPGAs and ASICs are also described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Huan, Junjun, Dehghanzadeh, Peyman, Mandal, Soumyajit, Bhunia, Swarup. 2023-07-31. Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis. https://doi.org/10.1109/access.2023.3300222

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗