Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Lidar and radiometer results from the ER-2 for the FIRE field experiments

The airborne lidar and radiometers which were flown during the FIRE cirrus and marine stratus field experiments had multiple objectives. Cloud parameters of direct interest, such as cirrus infrared emittance or convective scales for marine stratus, may be derived from the observations and analyzed along with the available cloud physics and meteorological observations. Additionally however a stated goal of the FIRE studies was to validate satellite cloud retrievals. To this end a number of derived products are to be available from the basic lidar and radiometer observations. The characteristics of the derived products are described, and in addition analysis results for cloud radiometric and structure parameters are presented. This extended abstract will be used to describe the available data products and the associated presentation will emphasize case study analysis results.

Spinhirne, James D.↗

The Parkes front-end controller and noise-adding radiometer

A new front-end controller (FEC) was installed on the 64-m antenna in Parkes, Australia, to support the 1989 Voyager 2 Neptune encounter. The FEC was added to automate operation of the front-end microwave hardware as part of the Deep Space Network's Parkes-Canberra Telemetry Array. Much of the front-end hardware was refurbished and reimplemented from a front-end system installed in 1985 by the European Space Agency for the Uranus encounter; however, the FEC and its associated noise-adding radiometer (NAR) were new Jet Propulsion Laboratory (JPL) designs. Project requirements and other factors led to the development of capabilities not found in standard Deep Space Network (DSN) controllers and radiometers. The Parkes FEC/NAR performed satisfactorily throughout the Neptune encounter and was removed in October 1989.

Brunzie, T. J.↗

On-orbit structural dynamic performance of a 15-meter microwave radiometer antenna

The on-orbit structural dynamic performance of a microwave radiometer antenna for Earth science applications is addressed. The radiometer is one of the Earth-observing instruments aboard a proposed geostationary platform as part of the Mission to the Planet Earth. A sequential approach is presented for assessing the ability of an antenna structure to retain its geometric shape subject to a representative onboard disturbance. This approach includes establishing the structural requirements of the antenna, developing the structural and disturbance models, performing modal and forced response analyses, and evaluating the resulting distortions in terms of the antenna's ability to meet stringent structural performance requirements. Two antenna configurations are discussed: free-flying and platform-mounted. These configurations are analyzed for a representative disturbance function which simulates rotation of the subreflector in order to perform a raster-type scan of the Earth disk. Results show that the scanning maneuver modeled would not induce antenna structural errors outside the specified limits.

Wahls, Deborah M.↗

The Millimeter-Wave Imaging Radiometer (MIR)

The Millimeter-Wave Imaging Radiometer (MIR) is a new instrument being designed for studies of airborne passive microwave retrieval of tropospheric water vapor, clouds, and precipitation parameters. The MIR is a total-power cross-track scanning radiometer for use on either the NASA ER-2 (high-altitude) or DC-8 (medium altitude) aircraft. The current design includes millimeter-wave (MMW) channels at 90, 166, 183 +/- 1,3,7, and 220 GHz. An upgrade for the addition of submillimeter-wave (SMMW) channels at 325 +/- 1,3,7 and 340 GHz is planned. The nadiral spatial resolution is approximately 700 meters at mid-altitude when operated aboard the NASA ER-2. The MIR consists of a scanhead and data acquisition system, designed for installation in the ER-2 superpod nose cone. The scanhead will house the receivers (feedhorns, mixers, local oscillators, and preamplifiers), a scanning mirror, hot and cold calibration loads, and temperature sensors. Particular attention is being given to the characterization of the hot and cold calibration loads through both laboratory bistatic scattering measurements and analytical modeling. Other aspects of the MIR and the data acquisition system are briefly discussed, and diagrams of the location of the MIR in the ER-2 superpod nosecone and of the data acquisition system are presented.

Gasiewski, A. J.↗

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

On-orbit structural dynamic performance of a low-frequency microwave radiometer for Mission to Planet Earth applications

The present paper addresses the on-orbit dynamic performance of a low-frequency microwave radiometer for earth science applications. The radiometer is one of the earth-observing instruments aboard a geostationary platform proposed as part of the Mission to Planet Earth. The paper includes establishing the structural requirements of the antenna, developing the structural and disturbance models, performing modal and forced response analyses, and evaluating the resulting distortions in terms of the antenna's ability to meet stringent structural performance requirements. Two antenna configurations are discussed: free-flying and platform-mounted. These configurations are analyzed for a representative disturbance function which simulates rotation of the subreflector in order to perform a raster-type scan of the earth disk. Results show that the scanning maneuver modeled did not induce antenna performance errors which were outside their estimated limits.

Wahls, Deborah M.↗

Interpreting measurements obtained with the cloud absorption radiometer

The software developed for the analysis of data from the Cloud Absorption Radiometer (CAR) is discussed. The CAR is a multichannel radiometer designed to measure the radiation field in the middle of an optically thick cloud (the diffusion domain). It can also measure the surface albedo and escape function. The instrument currently flies on a C-131A aircraft operated by the University of Washington. Most of this data was collected during the First International satellite cloud climatology project Regional Experiment (FIRE) Marine Stratocumulus Intensive Field Observation program off San Diego during July 1987. Earlier flights of the CAR have also been studied.

Source record↗

Monolithic microwave integrated circuit water vapor radiometer

A proof of concept Monolithic Microwave Integrated Circuit (MMIC) Water Vapor Radiometer (WVR) is under development at the Jet Propulsion Laboratory (JPL). WVR's are used to remotely sense water vapor and cloud liquid water in the atmosphere and are valuable for meteorological applications as well as for determination of signal path delays due to water vapor in the atmosphere. The high cost and large size of existing WVR instruments motivate the development of miniature MMIC WVR's, which have great potential for low cost mass production. The miniaturization of WVR components allows large scale deployment of WVR's for Earth environment and meteorological applications. Small WVR's can also result in improved thermal stability, resulting in improved calibration stability. Described here is the design and fabrication of a 31.4 GHz MMIC radiometer as one channel of a thermally stable WVR as a means of assessing MMIC technology feasibility.

Sukamto, L. M.↗

Characterization of the Earth Radiation Budget Experiment radiometers

The Earth Radiation Budget Experiment (ERBE) scanning radiometers were used to measure the earth's radiation fields during the period November 1984 through February 1990. The ERBE radiometric packages were placed into orbit aboard the Earth Radiation Budget Satellite (ERBS) and the NOAA-9 and NOAA-10 spacecraft platforms. In each radiometric package, thermistor bolometers were used as detection elements for the broadband total (0,2 - 50,0 microns), shortwave (0,2 - 5,0 microns), and longwave (5,0 - 50,0 microns) spectral regions. Flight calibration facilities were built into each of the spacecraft radiometric packages. The flight facilities consisted of black bodies, tungsten lamps, and silicon photodiodes. The black bodies and tungsten lamps were found to be reliable at precision levels approaching 0,5 percent over a five-year period. The photodiodes were found to degrade more than 2 percent during the first year in orbit. In this paper, the flight calibration systems for the ERBE scanning radiometers are described along with the resultant measurements.

Lee, R. B., III↗

COBE differential microwave radiometers - Calibration techniques

The COBE spacecraft was launched November 18, 1989 UT carrying three scientific instruments into earth orbit for studies of cosmology. One of these instruments, the Differential Microwave Radiometer (DMR), is designed to measure the large-angular-scale temperature anisotropy of the cosmic microwave background radiation at three frequencies (31.5, 53, and 90 GHz). This paper presents three methods used to calibrate the DMR. First, the signal difference between beam-filling hot and cold targets observed on the ground provides a primary calibration that is transferred to space by noise sources internal to the instrument. Second, the moon is used in flight as an external calibration source. Third, the signal arising from the Doppler effect due to the earth's motion around the barycenter of the solar system is used as an external calibration source. Preliminary analysis of the external source calibration techniques confirms the accuracy of the currently more precise ground-based calibration. Assuming the noise source behavior did not change from the ground-based calibration to flight, a 0.1-0.4 percent relative and 0.7-2.5 percent absolute calibration uncertainty is derived, depending on radiometer channel.

Bennett, C. L.↗

Structure in the COBE differential microwave radiometer first-year maps

Results of the first year of data from the differential microwave radiometers on the Cosmic Background Explorer are presented. Statistically significant structure that is well described as scale-invariant fluctuations with a Gaussian distribution is shown. The rms sky variation, smoothed to a total 10-deg FWHM Gaussian, is 30 +/-5 micro-K for Galactic latitude greater than 20-deg data with the dipole anisotropy removed. The rms cosmic quadrupole amplitude is 13 +/-4 micro-K. The angular autocorrelation of the signal in each radiometer channel and cross-correlation between channels are consistent and give a primordial fluctuation power-law spectrum with index of 1.1 +/-0.5, and an rms-quadrupole-normalized amplitude of 16 +/-4 micro-K. These features are in accord with the Harrison-Zel'dovich spectrum predicted by models of inflationary cosmology.

Smoot, G. F.↗

MMIC Receiver For Water-Vapor Radiometer

MMIC receiver puts out signal, frequency of which proportioned to brightness temperature of sky at input frequency of 31 GHz. Miniaturization enhances thermal stability and stability of calibration of water-vapor radiometer. Potential for mass production at relatively low cost. Facilitating widespread use of MMIC water vapor radiometers in meteorology and aviation, deployed at several global sites to improve capability of general circulation models and at airports to monitor icing conditions by measuring supercooled liquid water in clouds.

Sukamto, Lin M.↗

The Split Window Microwave Radiometer (SWMR) for hurricane wind speed measurement from space

The monitoring of hurricanes demands considerable resources each year by the National Oceanic and Atmospheric Administration. Even with the extensive use of satellite and airborne probing of those storms, there is still much uncertainty involved in predicting landfall for timely evacuation of people subject to the threat. The concept of the Split Window Microwave Radiometer (SWMR) is to add an additional capability of remotely measuring surface winds to hopefully improve prediction capabilities or at least define the severity of the storm while it is far from land. Some of the present science and observational needs are addressed in this report as are remote sensing limitations which impact the design of a minimal system which can be launched into low earth orbit by a low cost launch system. This study has concluded that wind speed and rain rate maps of hurricanes can be generated with an X-Band radiometer system with an antenna whose aperture is 2 m on a side.

Swift, Calvin T.↗

All-solid-state radiometers for environmental studies to 700 GHz

We report results with an all-solid-state radiometer for measurements of the ClO molecule at 649 GHz. The project is part of a program to provide low-noise, low-weight, low-power radiometers for space operation, and special effort has been expended on the development of high-efficiency solid-state frequency multipliers and Schottky-barrier mixers with low local oscillator power requirements. The best measured system noise temperature was 1750 K with the mixer and preamplifier cooled to 77 K. The mixer diode was easily pumped into saturation, indicating that the design has excellent prospects of operating at higher frequencies - our present design goal being 1 THz. We comment on the principal design features of such systems and will report on stratospheric measurements performed with this system.

Zimmermann, Ralph↗

ESTAR: The Electronically Scanned Thinned Array Radiometer for remote sensing measurement of soil moisture and ocean salinity

The product of a working group assembled to help define the science objectives and measurement requirements of a spaceborne L-band microwave radiometer devoted to remote sensing of surface soil moisture and sea surface salinity is presented. Remote sensing in this long-wavelength portion of the microwave spectrum requires large antennas in low-Earth orbit to achieve acceptable spatial resolution. The proposed radiometer, ESTAR, is unique in that it employs aperture synthesis to reduce the antenna area requirements for a space system.

Swift, C. T.↗

A ratioing radiometer for use with a solar diffuser

The use of an on-board solar diffuser has been proposed to monitor the in-flight calibration of satellite sensors. This paper presents the preliminary specifications and design for a ratioing radiometer, to be used to determine the change in radiance of the solar diffuser. The issues involved in spectral channel selection are discussed and the effects of stray light are presented. An error analysis showing the benefit of the ratioing radiometer is included.

Palmer, James M.↗

Spatial sampling errors for a satellite-borne scanning radiometer

The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer is planned as the Earth radiation budget instrument for the Earth Observation System, to be flown in the late 1990's. In order to minimize the spatial sampling errors of the measurements, it is necessary to select design parameters for the instrument such that the resulting point spread function will minimize spatial sampling errors. These errors are described as aliasing and blurring errors. Aliasing errors are due to presence in the measurements of spatial frequencies beyond the Nyquist frequency, and blurring errors are due to attenuation of frequencies below the Nyquist frequency. The design parameters include pixel shape and dimensions, sampling rate, scan period, and time constants of the measurements. For a satellite-borne scanning radiometer, the pixel footprint grows quickly at large nadir angles. The aliasing errors thus decrease with increasing scan angle, but the blurring errors grow quickly. The best design minimizes the sum of these two errors over a range of scan angles. Results of a parameter study are presented, showing effects of data rates, pixel dimensions, spacecraft altitude, and distance from the spacecraft track.

Manalo, Natividad D.↗

Scanning mirror design considerations for a geostationary spaceborne radiometer

This paper will address the design considerations and challenges for a radiometer scanning mirror in a Geostationary (GEO) orbit. With increasingly demanding imaging requirements, mirror designs that are insensitive to the harsh thermal environment will be required. The compatibility of various mirror designs for a precision radiometer will be examined and discussed. The design solutions considered will include material, geometry and thermal design tradeoffs.

Hookman, R. A.↗