Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Technique for Radiometer and Antenna Array Calibration - TRAAC

Highly sensitive receivers are used to detect minute amounts of emitted electromagnetic energy. Calibration of these receivers is vital to the accuracy of the measurements. Traditional calibration techniques depend on calibration reference internal to the receivers as reference for the calibration of the observed electromagnetic energy. Such methods can only calibrate errors in measurement introduced by the receiver only. The disadvantage of these existing methods is that they cannot account for errors introduced by devices, such as antennas, used for capturing electromagnetic radiation. This severely limits the types of antennas that can be used to make measurements with a high degree of accuracy. Complex antenna systems, such as electronically steerable antennas (also known as phased arrays), while offering potentially significant advantages, suffer from a lack of a reliable and accurate calibration technique. The proximity of antenna elements in an array results in interaction between the electromagnetic fields radiated (or received) by the individual elements. This phenomenon is called mutual coupling. The new calibration method uses a known noise source as a calibration load to determine the instantaneous characteristics of the antenna. The noise source is emitted from one element of the antenna array and received by all the other elements due to mutual coupling. This received noise is used as a calibration standard to monitor the stability of the antenna electronics.

Meyer, Paul↗

Optoelectronic Tweezers for Microparticle and Cell Manipulation

An optical image-driven light induced dielectrophoresis (DEP) apparatus and method are described which provide for the manipulation of particles or cells with a diameter on the order of 100 micromillimeters or less. The apparatus is referred to as optoelectric tweezers (OET) and provides a number of advantages over conventional optical tweezers, in particular the ability to perform operations in parallel and over a large area without damage to living cells. The OET device generally comprises a planar liquid-filled structure having one or more portions which are photoconductive to convert incoming light to a change in the electric field pattern. The light patterns are dynamically generated to provide a number of manipulation structures that can manipulate single particles and cells or group of particles/cells. The OET preferably includes a microscopic imaging means to provide feedback for the optical manipulation, such as detecting position and characteristics wherein the light patterns are modulated accordingly.

Wu, Ming Chiang↗

Electronically Calibratable Clock

Calibration circuit corrects apparent clock rate (ACR) of digital clock without altering oscillator frequency. Calibration circuit does not require iterative adjustments to reference frequency or rate, and correction to ACR is controlled by pushbuttons. Technique is applicable to any timer or counter that counts up to predetermined number then outputs a pulse to a readout register or to control another device.

Davidson, J. R.↗

Satellite Attitude Control Using a Combination of Inertia Wheels and a Bar Magnet

The use of inertia wheels to control the attitude of a satellite has currently aroused much interest. The stability of such a system has been studied in this investigation. A single-degree-of-freedom analysis indicates that a response with suitable dynamic characteristics and precise control can be achieved by commanding the angular velocity of the inertia wheel with an error signal that is the sum of the attitude error, the attitude rate, and the integral of the attitude error. A digital computer was used to study the three-degree-of-freedom response to step displacements, and the results indicate that the cross-coupling effects of inertia coupling and precession coupling had no effect on system stability. A study was also made of the use of a bar magnet to supplement the inertia wheels by providing a means of removing any momentum introduced into the system by disturbances such as aerodynamic torques. A study of a case with large aerodynamic torques, with a typical orbit, indicated that the magnet was a suitable device for supplying the essential trimming force. Single-degree-of-freedom bench tests generally verified the dynamic response predicted by the analytical study. the test table to within plus or minus 9 arc-seconds of the reference direction, even though the hardware components that were used in these tests were not specifically designed for the control system.

Adams, James J.↗

Characterization of bioelectric potentials

Method and system for recognizing and characterizing bioelectric potential or electromyographic (EMG) signals associated with at least one of a coarse gesture and a fine gesture that is performed by a person, and use of the bioelectric potentials to enter data and/or commands into an electrical and/or mechanical instrument. As a gesture is performed, bioelectric signals that accompany the gesture are subjected to statistical averaging, within selected time intervals. Hidden Markov model analysis is applied to identify hidden, gesture-related states that are present. A metric is used to compare signals produced by a volitional gesture (not yet identified) with corresponding signals associated with each of a set of reference gestures, and the reference gesture that is closest to the volitional gesture is identified. Signals representing the volitional gesture are analyzed and compared with a database of reference gestures to determine if the volitional gesture is likely to be one of the reference gestures. Electronic and/or mechanical commands needed to carry out the gesture may be implemented at an interface to control an instrument. Applications include control of an aircraft, entry of data from a keyboard or other data entry device, and entry of data and commands in extreme environments that interfere with accurate entry.

Jorgensen, Charles C.↗

Electronic depth micrometer

Device for measuring depth or thickness reads distance of penetration by small-diameter probe. It was developed specifically to measure thickness of wet (uncured) insulation applied to Space Shuttle structures; thin probes penetrate wet insulation to substrate, and reference surface on gage is then positioned against outer surface of insulation to measure its thickness. Gage is easy to use, even by workers wearing gloves or other protective clothing, and allows remote reading and recording of production data.

Major, R. K.↗

A Structured Light Sensor System for Tree Inventory

Tree Inventory is referred to measurement and estimation of marketable wood volume in a piece of land or forest for purposes such as investment or for loan applications. Exist techniques rely on trained surveyor conducting measurements manually using simple optical or mechanical devices, and hence are time consuming subjective and error prone. The advance of computer vision techniques makes it possible to conduct automatic measurements that are more efficient, objective and reliable. This paper describes 3D measurements of tree diameters using a uniquely designed ensemble of two line laser emitters rigidly mounted on a video camera. The proposed laser camera system relies on a fixed distance between two parallel laser planes and projections of laser lines to calculate tree diameters. Performance of the laser camera system is further enhanced by fusion of information induced from structured lighting and that contained in video images. Comparison will be made between the laser camera sensor system and a stereo vision system previously developed for measurements of tree diameters.

Chien, Chiun-Hong↗

Ion Storage with the High Performance Antiproton Trap (HiPAT)

The matter antimatter reaction represents the densest form of energy storage/release known to modern physics: as such it offers one of the most compact sources of power for future deep space exploration. To take the first steps along this path, NASA-Marshall Space Flight Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a goal of maintaining 10(exp 12) particles for up to 18 days. Experiments have been performed with this hardware using normal matter (positive hydrogen ions) to assess the device's ability to hold charged particles. These ions are currently created using an electron gun method to ionize background gas; however, this technique is limited by the quantity that can be captured. To circumvent this issue, an ion source is currently being commissioned which will greatly increase the number of ions captured and more closely simulate actual operations expected at an antiproton production facility. Ions have been produced, stored for various time intervals, and then extracted against detectors to measure species, quantity and energy. Radio frequency stabilization has been tested as a method to prolong ion lifetime: results show an increase in the baseline 1/e lifetime of trapped particles from hours to days. Impurities in the residual background gas (typically carbon-containing species CH4, CO, CO2, etc.) present a continuing problem by reducing the trapped hydrogen population through the mechanism of ion charge exchange.

Martin, James↗

Risk-Informed Safety Assurance and Probabilistic Assessment of Mission-Critical Software-Intensive Systems

This report validates and documents the detailed features and practical application of the framework for software intensive digital systems risk assessment and risk-informed safety assurance presented in the NASA PRA Procedures Guide for Managers and Practitioner. This framework, called herein the "Context-based Software Risk Model" (CSRM), enables the assessment of the contribution of software and software-intensive digital systems to overall system risk, in a manner which is entirely compatible and integrated with the format of a "standard" Probabilistic Risk Assessment (PRA), as currently documented and applied for NASA missions and applications. The CSRM also provides a risk-informed path and criteria for conducting organized and systematic digital system and software testing so that, within this risk-informed paradigm, the achievement of a quantitatively defined level of safety and mission success assurance may be targeted and demonstrated. The framework is based on the concept of context-dependent software risk scenarios and on the modeling of such scenarios via the use of traditional PRA techniques - i.e., event trees and fault trees - in combination with more advanced modeling devices such as the Dynamic Flowgraph Methodology (DFM) or other dynamic logic-modeling representations. The scenarios can be synthesized and quantified in a conditional logic and probabilistic formulation. The application of the CSRM method documented in this report refers to the MiniAERCam system designed and developed by the NASA Johnson Space Center.

Guarro, Sergio B.↗

Control Software for Piezo Stepping Actuators

A control system has been developed for the Space Interferometer Mission (SIM) piezo stepping actuator. Piezo stepping actuators are novel because they offer extreme dynamic range (centimeter stroke with nanometer resolution) with power, thermal, mass, and volume advantages over existing motorized actuation technology. These advantages come with the added benefit of greatly reduced complexity in the support electronics. The piezo stepping actuator consists of three fully redundant sets of piezoelectric transducers (PZTs), two sets of brake PZTs, and one set of extension PZTs. These PZTs are used to grasp and move a runner attached to the optic to be moved. By proper cycling of the two brake and extension PZTs, both forward and backward moves of the runner can be achieved. Each brake can be configured for either a power-on or power-off state. For SIM, the brakes and gate of the mechanism are configured in such a manner that, at the end of the step, the actuator is in a parked or power-off state. The control software uses asynchronous sampling of an optical encoder to monitor the position of the runner. These samples are timed to coincide with the end of the previous move, which may consist of a variable number of steps. This sampling technique linearizes the device by avoiding input saturation of the actuator and makes latencies of the plant vanish. The software also estimates, in real time, the scale factor of the device and a disturbance caused by cycling of the brakes. These estimates are used to actively cancel the brake disturbance. The control system also includes feedback and feedforward elements that regulate the position of the runner to a given reference position. Convergence time for smalland medium-sized reference positions (less than 200 microns) to within 10 nanometers can be achieved in under 10 seconds. Convergence times for large moves (greater than 1 millimeter) are limited by the step rate.

Shields, Joel F.↗

Extracts from the test plan for in-flight evaluation of the NT-33A peripheral vision display

The Peripheral Vision Display (PVD) which presents the pilot with a gyro stabilized artificial horizon projected onto his instrument panel by a laser light source is outlined. During instrument flight conditions, such a display allows the pilot to gain attitude awareness by sensing the horizon line through his peripheral vision. The pilot can detect changes to aircraft attitude without continuously referring back to his flight instruments. A second generation PVD unit was installed in the USAF/Calspan NT-33A during late 1982. An NT-33A flight evaluation of the display provides a unique opportunity to utilize a Workload Assessment Device (WAD) to obtain quantitative data regarding the utility of the PVD in reducing pilot workload. The experimental design and procedures for a two phase NT-33 PVD flight evaluation program is described.

Knotts, L.↗

Autonomous Medical Care for Exploration

The goal of Autonomous Medical Care (AMC) is to ensure a healthy, well-performing crew which is a primary need for exploration. The end result of this effort will be the requirements and design for medical systems for the CEV, lunar operations, and Martian operations as well as a ground-based crew health optimization plan. Without such systems, we increase the risk of medical events occurring during a mission and we risk being unable to deal with contingencies of illness and injury, potentially threatening mission success. AMC has two major components: 1) pre-flight crew health optimization and 2) in-flight medical care. The goal of pre-flight crew health optimization is to reduce the risk of illness occurring during a mission by primary prevention and prophylactic measures. In-flight autonomous medical care is the capability to provide medical care during a mission with little or no real-time support from Earth. Crew medical officers or other crew members provide routine medical care as well as medical care to ill or injured crew members using resources available in their location. Ground support becomes telemedical consultation on-board systems/people collect relevant data for ground support to review. The AMC system provides capabilities to incorporate new procedures and training and advice as required. The on-board resources in an autonomous system should be as intelligent and integrated as is feasible, but autonomous does not mean that no human will be involved. The medical field is changing rapidly, and so a challenge is to determine which items to pursue now, which to leverage other efforts (e.g. military), and which to wait for commercial forces to mature. Given that what is used for the CEV or the Moon will likely be updated before going to Mars, a critical piece of the system design will be an architecture that provides for easy incorporation of new technologies into the system. Another challenge is to determine the level of care to provide for each mission type. The level of care refers to the amount and type of care one will render based on perceived need and ability. This is in contrast to the standard of care which is the benchmark by which that care is provided. There are certainly some devices and procedures that have unique microgravity or partial gravity requirements such that terrestrial methods will not work. For example, performing CPR on Mars cannot be done in exactly the same way as on Earth because the reduced gravity causes too large a reduction in the forces available for effective compression of the chest. Likewise, fluid behavior in microgravity may require a specialized water filtration and mixing system for the creation of intravenous fluids. This paper will outline the drivers for the design of the medical care systems, prioritization and planning techniques, key system components, and long term goals.

Johnson-Throop, Kathy A.↗

Dynamics and control of a tumbling satellite retrieval device

The problem of capturing a satellite in an uncontrolled three-axis tumble is addressed. The proposed solution is a truss which opens and engulfs the satellite, resulting in coincident centers of mass. Torques are then applied to the truss so that it matches the tumble rates of the satellite and remains motionless in the satellite's reference frame. Equations are derived which show how to vary the mass distribution to match any set of inertia moment ratios. The physical system is shown to be controllable. An optimal control algorithm for tumble matching is then derived and a computer simulation is developed.

Neff, J. M.↗

Fixed-trim re-entry guidance analysis

The terminal guidance problem for a fixed-trim re-entry body is formulated with the objective of synthesizing a closed-loop steering law. A transformation of variables and subsequent linearization of the motion, with the sight-line to the target as a reference, reduces the order of the state system for the guidance problem. The reduced order system, although nonlinear and time-varying, is simple enough to lend itself to synthesis of a class of guidance laws. A generalization of the feedforward device of classical control theory is successfully employed for compensation of roll autopilot lags. The proposed steering law exhibits superior miss-distance performance in a computational comparison with existing fixed-trim guidance laws.

Gracey, C.↗

Water Pollution Detection by Reflectance Measurements

Measurement of the intensity of light reflected from various planar liquid surfaces has been performed. The results of this brief study show that the presence of a film of foreign material floating on a reference substrate is easily detected by reflectance measurement if the two liquids possess significantly different refractive indices, for example, oil (n = 1.40) and water (n = 1.33). Additional study of various optical configurations, and the building and testing of a prototype monitoring device revealed that the method is sufficiently practical for application to continuous water quality monitoring.

Goolsby, A. D.↗

Holographic Weapons Sight as Crew Optical Alignment Sight

Crew Optical Alignment Sights (COAS) are used by spacecraft pilots to provide a visual reference to a target spacecraft for lateral relative position during rendezvous and docking operations. NASA s Orion vehicle, which is currently under development, has not included a COAS in favor of automated sensors, but the crew office has requested such a device be added for situational awareness and contingency support. The current Space Shuttle COAS was adopted from Apollo heritage, weighs several pounds, and is no longer available for procurement which would make re-use difficult. In response, a study was conducted to examine the possibility of converting a commercially available weapons sight to a COAS for the Orion spacecraft. The device used in this study was the XPS series Holographic Weapon Sight (HWS) procured from L-3 EOTech. This device was selected because the targeting reticule can subtend several degrees, and display a graphic pattern tailored to rendezvous and docking operations. Evaluations of the COAS were performed in both the Orion low-fidelity mockup and rendezvous simulations in the Reconfigurable Operational Cockpit (ROC) by crewmembers, rendezvous engineering experts, and flight controllers at Johnson Space Center. These evaluations determined that this unit s size and mounting options can support proper operation and that the reticule visual qualities are as good as or better than the current Space Shuttle COAS. The results positively indicate that the device could be used as a functional COAS and supports a low-cost technology conversion solution.

Merancy, Nujoud↗

Subsystem design package for the on-site monitor at solar heating and cooling sites

The on-site monitor is a portable device which can be easily connected to a Site Data Acquisition Subsystem to allow readouts of realtime sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The design package consists of the performance specification, performance requirements cross reference, and the acceptance test procedure.

Source record↗

System for use in conducting wake investigation for a wing in flight

A system supported by a wing in flight is described which has a reference total pressure port in spaced relation with a wake as the wake is generated by the wing, a reference static pressure port supported in spaced relation with the wake, and a probe adapted to be displaced along an accurate path through the wake including a total pressure port and static pressure ports. A differential pressure transducer and a pressure switching device are interposed between the ports and the transducer is provided for selectively connecting pairs of the ports to the transducer in opposed relation, whereby a single transducer is utilized to obtain differential pressure measurement for the wake with enhanced accuracy.

Bikle, P. F.↗