Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample acquisitions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Recurrent and convolutional neural networks for sequential multispectral optoacoustic tomography ( MSOT ) imaging

Abstract Multispectral optoacoustic tomography (MSOT) is a beneficial technique for diagnosing and analyzing biological samples since it provides meticulous details in anatomy and physiology. However, acquiring high through‐plane resolution volumetric MSOT is time‐consuming. Here, we propose a deep learning model based on hybrid recurrent and convolutional neural networks to generate sequential cross‐sectional images for an MSOT system. This system provides three modalities (MSOT, ultrasound, and optoacoustic imaging of a specific exogenous contrast agent) in a single scan. This study used ICG‐conjugated nanoworms particles (NWs‐ICG) as the contrast agent. Instead of acquiring seven images with a step size of 0.1 mm, we can receive two images with a step size of 0.6 mm as input for the proposed deep learning model. The deep learning model can generate five other images with a step size of 0.1 mm between these two input images meaning we can reduce acquisition time by approximately 71%.

Juhong, Aniwat↗

Non-destructive spatial analysis of phosphatase activity and total protein distribution in the rhizosphere using a root blotting method

Phosphorus (P) is an essential macronutrient for plant growth, but bioavailable P in soils is often limited due to immobilization resulting from pH and geochemical interactions. Understanding the dynamics of P in soils and elucidating the mechanisms by which plants access P from their environment are critical to evaluating productivity, particularly in nutrient poor environments. Phosphorus from organic matter can act as a major source of P for organisms in soil systems. Phosphatases, enzymes that liberate inorganic P from organic sources, are produced by both plants and microbes and are considered one of the most active classes of enzymes in soil. In this work we developed a root blotting method to spatially image phosphatase activity in the rhizosphere. Proteins from the rhizosphere are transferred to a nitrocellulose membrane while retaining their enzymatic activity and two-dimensional spatial distribution. Subsequent application of a fluorogenic phosphatase indicator, DDAO phosphate, enables visualization of the distribution of phosphatase activity in the sample. The proteins can then be fixed to the membrane and treated with a SYPRO® Ruby gel stain, a fluorescent total protein stain, allowing for visualization of total protein distribution. Taken together, the images of phosphatase activity and total protein localization can be mapped back to the root architecture and provide insight into factors affecting the spatial distribution of enzymatic activity and protein accumulation in the rhizosphere. Notably, this method can be applied to plants growing in rhizoboxes containing soil or soilless growth mixtures (e.g., sand or various potting mixes) and, because of the non-destructive nature of this approach, be performed over time to track changes. We anticipate that this fluorescent indicator imaging technique on root blots can be used in diverse plant-microbe-soil systems to better understand the role of phosphatases in P acquisition and soil P cycling.

59 BASIC BIOLOGICAL SCIENCES↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective One-Dimensional 13 C– 13 C Spin-Diffusion Solid-State Nuclear Magnetic Resonance Methods to Probe Spatial Arrangements in Biopolymers Including Plant Cell Walls, Peptides, and Spider Silk

Two-dimensional (2D) and 3D through-space 13 C– 13 C homonuclear spin-diffusion techniques are powerful solid-state nuclear magnetic resonance (NMR) tools for extracting structural information from 13 C-enriched biomolecules, but necessarily long acquisition times restrict their applications. In this work, we explore the broad utility and underutilized power of a chemical shift-selective one-dimensional (1D) version of a 2D 13 C– 13 C spin-diffusion solid-state NMR technique. The method, which is called 1D dipolar-assisted rotational resonance (DARR) difference, is applied to a variety of biomaterials including lignocellulosic plant cell walls, microcrystalline peptide fMLF, and black widow dragline spider silk. 1D 13 C– 13 C spin-diffusion methods described here apply in select cases in which the 1D 13 C solid-state NMR spectrum displays chemical shift-resolved moieties. Furthermore, this is analogous to the selective 1D nuclear Overhauser effect spectroscopy (NOESY) experiment utilized in liquid-state NMR as a faster (1D instead of 2D) and often less ambiguous (direct sampling of the time domain data, coupled with increased signal averaging) alternative to 2D NOESY. Selective 1D 13 C– 13 C spin-diffusion methods are more time-efficient than their 2D counterparts such as proton-driven spin diffusion (PDSD) and dipolar-assisted rotational resonance. The additional time gained enables measurements of 13 C– 13 C spin-diffusion buildup curves and extraction of spin-diffusion time constants TSD, yielding detailed structural information. Specifically, selective 1D DARR difference buildup curves applied to 13 C-enriched hybrid poplar woody stems confirm strong spatial interaction between lignin and acetylated xylan polymers within poplar plant secondary cell walls, and an interpolymer distance of ~0.45–0.5 nm was estimated. Additionally, Tyr/Gly long-range correlations were observed on isotopically enriched black widow spider dragline silks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Melt pool temperature measurement and monitoring during laser powder bed fusion based additive manufacturing via single-camera two-wavelength imaging pyrometry (STWIP)

Melt pool (MP) temperature is one of the determining factors and a key signature for evaluating the properties of printed components in metal additive manufacturing (AM). The state-of-the-art measurement systems are hindered, primarily by the large-scale data acquisition and processing demands. In this work, we introduce a novel coaxial, high-speed, single-camera two-wavelength imaging pyrometer (STWIP) system as opposed to the typical utilization of multiple cameras for measuring MP temperature profiles in laser powder bed fusion (LPBF) processes. Developed on a commercial LPBF machine (EOS M290), the STWIP system demonstrated its ability to quantitatively monitor the MP temperature and its variation for 50 layers at high framerates (>30,000 fps) for a real-world application (standard fatigue specimens) print. High performance computing is employed to analyze the acquired big data (MP images), for determining each MP's average temperature and 2D temperature profile. The MP temperature evolution in the gage section of a fatigue specimen is also examined at a temporal resolution of 1 ms, by evaluating the MP temperatures in the samples' first, middle, and last layers. This report is the first of its kind on monitoring MP temperature distribution and evolution at such a large, detailed scale for longer durations in practical applications.

42 ENGINEERING↗

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tutorial on In Situ and Operando (Scanning) Transmission Electron Microscopy for Analysis of Nanoscale Structure–Property Relationships

In situ and operando (scanning) transmission electron microscopy [(S)TEM] is a powerful characterization technique that uses imaging, diffraction, and spectroscopy to gain nano-to-atomic scale insights into the structure–property relationships in materials. This technique is both customizable and complex because many factors impact the ability to collect structural, compositional, and bonding information from a sample during environmental exposure or under application of an external stimulus. In the past two decades, in situ and operando (S)TEM methods have diversified and grown to encompass additional capabilities, higher degrees of precision, dynamic tracking abilities, enhanced reproducibility, and improved analytical tools. Much of this growth has been shared through the community and within commercialized products that enable rapid adoption and training in this approach. This tutorial aims to serve as a guide for students, collaborators, and nonspecialists to learn the important factors that impact the success of in situ and operando (S)TEM experiments and assess the value of the results obtained. As this is not a step-by-step guide, readers are encouraged to seek out the many comprehensive resources available for gaining a deeper understanding of in situ and operando (S)TEM methods, property measurements, data acquisition, reproducibility, and data analytics.

(S)TEM↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

ThermoPore: Predicting part porosity based on thermal images using deep learning

Part qualification is often a critical and labor-intensive process in additive manufacturing, particularly in the detection of defects such as porosity, which stands to benefit significantly from advancements in machine learning. We present a deep learning approach for quantifying and localizing ex-situ porosity within Laser Powder Bed Fusion fabricated samples utilizing in-situ thermal image monitoring data. Our goal is to build the real time porosity map of parts based on thermal images acquired during the build. The quantification task builds upon the established Convolutional Neural Network model architecture to predict pore count and the localization task leverages the spatial and temporal attention mechanisms of the novel Video Vision Transformer model to indicate areas of expected porosity. Our model for porosity quantification achieved a R 2 score of 0.57 and our model for porosity localization produced an average Intersection over Union (IoU) score of 0.32 and a maximum of 1.0. This work is setting the foundations of part porosity “Digital Twins” based on additive manufacturing monitoring data and can be applied downstream to reduce time-intensive post-inspection and testing activities during part qualification and certification. In addition, we seek to accelerate the acquisition of crucial insights normally only available through ex-situ part evaluation by means of machine learning analysis of in-situ process monitoring data.

Deep learning↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ${\sim}{1000}$ to ${\sim}{3500}\;{{\rm cm}^{- 1}}$ but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

36 MATERIALS SCIENCE↗

Utah FORGE: Neubrex Well 16B(78)-32 DAS Data - April, 2024

This dataset comprises Distributed Acoustic Sensing (DAS) data collected from the Utah FORGE monitoring well 16B(78)-32 (the producer well) during hydraulic fracture stimulation operations conducted in April 2024. The data were acquired continuously over the stimulation period at a temporal sampling rate of 10,000 Hz (10 kS/s) and a spatial resolution of approximately 3.35 feet (1.02109 meters). The measurements were captured using a Neubrex NBX-S4100 Time Gated Digital DAS interrogator unit connected to a single-mode fiber optic cable, which was permanently installed within the casing string. All recorded channels correspond to downhole segments of the fiber optic cable, from a measured depth (MD) of 5,369.35 feet to 10,352.11 feet. The DAS data reflect raw acoustic energy generated by physical processes within and surrounding the well during stimulation activities at wells 16A(78)-32 and 16B(78)-32. These data have potential applications in analyzing cross-well strain, far-field strain rates (including microseismic activity), induced seismicity, and seismic imaging. Metadata embedded in the attributes of the HDF5 files include detailed information on the measured depths of the channels, interrogation parameters, and other acquisition details. The dataset also includes a recording of a seminar held on September 19, 2024, where Neubrex's Chief Operating Officer presented insights into the data collection, analysis, and preliminary findings. The raw data files, stored in HDF5 format, are organized chronologically according to the recording intervals from April 9 to April 24, 2024, with each file corresponding to a 12-second recording interval.

15 GEOTHERMAL ENERGY↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ∼ <#comment/> 1000 to ∼ <#comment/> 3500 c m − <#comment/> 1 but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

Doughty, Benjamin (ORCID:0000000164299329)↗

Exploring limitations in the induced polarization versus surface conductivity relationship in the case of wetland soils

Recent induced polarization studies suggest that the real part of surface conductivity (σ' surf ) scales linearly with the imaginary conductivity (σ'' = σ'' surf ) or normalized chargeability (Mn) for a range of soil types. The coefficients of this relationship l and l_Mn ( l = σ''/σ' surf or l_Mn = Mn/σ' surf ) allow the separation of the surface and electrolytic conductivities from the bulk conductivity. However, the dependence of these constants on varying soil physicochemical properties, including under unsaturated conditions, is yet to be assessed. Using estimates of σ' surf from 18 undisturbed soil samples from a restored wetland and σ'' measured over a frequency range of 0.01 Hz to 10 kHz, the σ' surf and σ'' were compared with the laboratory measurements of soil properties. Also, l and l_Mn were calculated for each soil sample and regressed them against the soil properties. We find an apparent dependence of l on soil texture, bulk density, organic matter, and moisture contents, with coefficients of determination (R 2 ) ranging from 0.5 to 0.65 at low frequencies (e.g., 1 Hz) but not at high frequencies (e.g., 936 Hz). This dependence of l on soil texture results from the insensitivity of σ'' at low frequency to σ' surf and, by implication, to the soil properties controlling σ' surf . In contrast, l_Mn indicates no correlation with the soil properties because Mn is linearly correlated with σ' surf and correlated with the soil properties controlling σ' surf . Finally, our results call for caution on the application of σ'' at a single frequency as a proxy of σ' surf because σ'' is not necessarily correlated with σ' surf across all soil types. Although using l_Mn derived from multifrequency measurements overcomes this limitation, field acquisition of spectral information (e.g., up to 1000 Hz) remains a challenge.

54 ENVIRONMENTAL SCIENCES↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Artificial Intelligence and Machine Learning Applications in Modern Power Systems

Machine learning (ML) and artificial intelligence (AI) algorithms offer valuable tools for the analysis and interpretation of large datasets. These tools have the capability to uncover insights that may not be readily apparent within these datasets. In recent years, the integration of ML and AI has become increasingly prevalent in various applications within the power system domain. One of the earliest instances of machine learning in power systems can be traced back to demand forecasting, where artificial neural networks were employed for short-term load forecasting. In contemporary power systems, an abundance of high-resolution geospatial and temporal data is generated at various time intervals, ranging from sub-seconds (Phasor Measurement Units or PMUs) to seconds (Supervisory Control and Data Acquisition or SCADA), minutes (Process Information or PI), and extending to days, months, and years. These datasets contain valuable information concerning system reliability and performance. This information holds the potential to offer critical insights into system operations, as well as solutions for predicting and mitigating contingencies to prevent cascading outages. Despite the immense power of machine learning tools, system operators, planners, and utilities often exhibit hesitancy in fully embracing AI-enabled system operations and planning. This cautious approach persists, even as numerous diverse applications of machine learning continue to emerge in the realm of power systems. In this chapter, our focus will delve deep into ML and AI applications tailored for power systems. These applications aim to furnish system operators with enhanced situational awareness and augment their decision-making capabilities, especially during challenging operating conditions. Specific areas of interest encompass root cause analyses of electricity market datasets and the strategic selection of representative samples from vast power system databases for training ML/AI models. Finally, the chapter will conclude with a short discussion on the future of ML/AI in power systems and possible directions that the industry is moving towards.

power system applications, machine learning (ML), ↗