Constraining Systematics at SBND to Reduce Uncertainties in SBN Oscillation Analyses

The Short Baseline Near Detector (SBND) is a crucial component of the Short Baseline Neutrino (SBN) Program, situated 110 meters from the Booster Neutrino Beam (BNB) target. This 112-ton Liquid Argon Time Projection Chamber (LArTPC) Near Detector is optimally positioned to investigate the potential existence of an additional flavor of neutrino through neutrino oscillation. Due to its proximity to the BNB target, SBND is uniquely positioned to receive a high rate of un-oscillated neutrino events. This setup offers a valuable opportunity to examine exclusive channels, thereby enhancing our understanding of various neutrino interaction modes, aiding in the understanding and mitigation of various sources of uncertainties. By fully utilizing the detector's capabilities, we aim to mitigate significant uncertainties in neutrino oscillation studies, primarily those related to neutrino interactions and flux. Achieving a deeper understanding of these uncertainties and controlling them with near detector data is essential. In this poster I will present an SBND event selection to control these uncertainties for the SBN oscillation analyses.

Yadav, Shweta [Texas U., Arlington]↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

A Parallel Computing Infrastructure for Building Energy Simulation

In order to study grid-interactive efficient buildings, Pacific Northwest National Laboratories (PNNL) needs an infrastructure for urban-scale building energy modeling. Such an infrastructure should be fast, scalable, and easy-to-use. Given a set of data from the Energy Information Administration’s Commercial Building Energy Consumption Survey (CBECS) and tool to translate survey data into simulation inputs, this project aimed to conduct the simulation of the entire dataset in parallel. Before running the simulations, the necessary software was bundled into a container for use on the PNNL supercomputing network. Then, the parallel simulation workflow was designed using GNU Make, a file creation software, and submitted to a supercomputing partition which could run hundreds of simulations simultaneously. The EnergyPlus simulations output hourly electric meter data for each CBECS sample, which represents the electricity consumption of similar commercial buildings across the United States. Analyzing and visualizing the meter data is important to the future of the work, and this project wrote code to make common analysis methods simple, fast, and accessible. Moving forwards, the model will need to be expanded to include data from other sources and its accuracy will need to be improved and eventually validated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Line Outage Detection in Transmission Systems with Few PMUs

Unlike transmission systems, distribution systems historically lack enough measurements, making their real-time monitoring almost impossible. Recent deployment of diverse types of devices such as phasor measurement units (PMUs), smart meters, solar inverters and weather information sensors opens up new ways of monitoring these systems, with the assistance of customized machine learning (ML) applications. The paper describes a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams and creates synchronous measurement snapshots to be used by a hybrid robust state estimator (SE) which provides not only accurate state estimates but also real-time feedback for ML model refinement. Improved monitoring performance due to the use of developed computational framework is experimentally observed by simulated scenarios on an electric utility’s distribution system.

Distribution systems, graph learning, machine lear↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗

High Fidelity Modeling of WELL58-32 DFITS

Between 2017 and 2019, a series of injection tests were performed at pilot vertical well 58-32 at the Utah FORGE site. These injection activities were conducted in three distinct zones, isolated with packers and bridge plugs during the tests. Zone 1 consists of an open-hole section at the toe of the well, whereas Zones 2 and 3 are three-meter long cased and perforated sections. Several injection cycles were conducted in each zone. A detailed description of the geology of the FORGE site, of well 58-32 and of all injection cycles can be found in (Xing et al., 2020). The injection cycles included Diagnostic Fracture Injection Tests (DFITs). DFITs comprise two primary stages: an injection (pump-in) phase, where controlled fluid injection is employed to create a small hydraulic fracture in the surrounding rock, followed by a shut-in phase, where injection ceases, allowing observation of the formation’s pressure response. Utilizing methodologies such as the G-function analysis, DFITs provide valuable insights, including fracture closure pressure and the Instantaneous Shut-in Pressure (ISIP) and can be employed to estimate the minimum horizontal stress.

42 ENGINEERING↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real Time - Optimal Power Flow Based Distributed Energy Resources Management System (DERMS) (CRADA Number CRD-20-16909 Final Report)

The integration of behind-the-meter distributed energy resources (DERs) into distribution systems brings transformative changes to power systems. This requires operators and planners to find solutions to modernize electric grids and to effectively manage DERs for grid services. NREL developed novel DER management algorithms (referred to as Real-Time Optimal Power Flow, RT-OPF) through U.S. Department of Energy (DOE)-funded efforts, including Advanced Research Projects Agency–Energy (ARPA-E) Network Optimized Distributed Energy Systems (NODES) funding. This cutting-edge control technology aims to modernize distribution systems with large amounts of DER integration, which will help utilities solve issues brought by renewable integration and build resilient and renewable-based electric grids nationwide. Utilidata worked with NREL to investigate the commercialization opportunity of this RT-OPF-based distributed energy resource management system (DERMS). In this project, NREL performs the technology transfer of the RT-OPF to Utilidata to help them fully understand the RT-OPF solution, to identify potential engineering hurdles, and to assess the expected commercial value of various RT-OPF use cases and deployment. The technology transfer work includes two major tasks. First, NREL performs an in-depth knowledge transfer of the entire RT-OPF solution to Utilidata to help them gain an extensive and detailed understanding of the complete RT-OPF solution. In this task, NREL provides exhaustive information (e.g., documentation, code packages, laboratory and field trial data, performance results) while conducting in-depth training sessions to provide a thorough explanation of the entire solution. NREL hosts meetings to present different topics related to the RT-OPF solution, and question-and-answer sessions are included in each meeting to better explain the RT-OPF-related work. Second, the RT-OPF simulations are performed in a laboratory environment. The main objectives of this task are to walk through with Utilidata engineers how to set up a simulation of RT-OPF, identifying each RT-OPF code block/component in operation, learning how these components interact with each other, and eventually running RT-OPF simulations under various system conditions. This task helps Utilidata engineers understand performance limitations and constraints while also quantifying the commercial value of the RT-OPF for different use cases. Based on these two tasks, Utilidata engineers should be able to define and prioritize the next steps of RT-OPF implementation with an eye toward commercial success and scalability of the solution. The next steps are expected to be part of a new project following the conclusion of this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating Large-Format Metal Additive Manufacturing: How Controls R&D is Driving Speed, Scale, and Efficiency

This article highlights work at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility to develop closed-loop, feedback control for laser-wire based Directed Energy Deposition, a form of metal Big Area Additive Manufacturing (m-BAAM), a process being developed in partnership with GKN Aerospace specifically for the production of Ti-6Al-4V pre-forms for aerospace components. A large-scale structural demonstrator component is presented as a case-study in which not just control, but the entire 3D printing workflow for m-BAAM is discussed in detail, including design principles for large-format metal AM, toolpath generation, parameter development, process control, and system operation, as well as post-print net-shape geometric analysis and finish machining. In terms of control, a multi-sensor approach has been utilized to measure both layer height and melt pool size, and multiple modes of closed-loop control have been developed to manipulate process parameters (laser power, print speed, deposition rate) to control these variables. Layer height control and melt pool size control have yielded excellent local (intralayer) and global (component-level) geometry control, and the impact of melt pool size control in particular on thermal gradients and material properties is the subject of continuing research. Further, these modes of control have allowed the process to advance to higher deposition rates (exceeding 7.5 lb/hr), larger parts (1-meter scale), shorter build times, and higher overall efficiency. The control modes are examined individually, highlighting their development, demonstration, and lessons learned, and it is shown how they operate concurrently to enable the printing of a large-scale, near net shape Ti-6Al-4V component.

Gibson, Brian↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smart connected worker edge platform for smart manufacturing: Part 2—Implementation and on‐site deployment case study

Abstract In this paper, we describe specific deployments of the Smart Connected Worker (SCW) Edge Platform for Smart Manufacturing through implementation of four instructive real‐world use cases that illustrate the role of people in a Smart Manufacturing paradigm through which affordable, scalable, accessible, and portable (ASAP) information technology (IT) acquires and contextualizes data into information for transmission to operation technologies (OT). For case one, the platform captures the relationships between energy consumption and human workflows for improved energy productivity while workers interact with machines during semiconductor manufacturing. The platform utilizes human cognition to identify anomalous machine behavior for root cause analysis of system faults via neural network (NN) that recognize alarm postures of workers with cameras. For case two, a smart assembly line is demonstrated for state monitoring and fault detection. Machine learning (ML) models are used to recognize system states and identify fault scenarios with human intervention. For case three, the platform monitors human–machine interactions to classify manufacturing machine states for proper operations and energy productivity. Internal energy states of individual or collections of manufacturing equipment are determined via NN based algorithms that disaggregate signals associated with smart metering typically deployed at manufacturing facilities. These methods predict the real time energy profile of each machine from the total energy profile of a manufacturing site. For case four, a software defined sensor system built with scientific workflow engines is demonstrated for contextualizing data from laser surface refraction for characterization, and diagnostics in the processing of additively manufactured titanium alloy.

Donovan, Richard P.↗

Waffle Homes: Utilizing Aerial Imagery of Unfinished Buildings to Determine Average Room Size

A primary function of the Population Density Tables Project (PDT) at Oak Ridge National Laboratory is to produce residential population densities per 1000 sq. ft. for each country and their associated first-level administrative units. This is accomplished by utilizing the average size of different types of dwelling areas (urban, rural, single-family, multi-family, etc.) and the average household size provided by a country’s Census or statistical bureau records. This data is available for the majority of Europe, North America, and large swathes of Asia, but is less easily found in Africa and South America. In these regions, Censuses generally report dwelling area by number of rooms, which poses the challenging question of how we can translate number of rooms to dwelling size when no dwelling size areas are available with which to compare. Using sub-meter resolution satellite imagery of Accra, Ghana, this challenge can be tackled using imagery of roofless buildings currently under construction that show the interior floor plan of the dwelling. A sample of buildings from the different neighborhoods of Accra can be digitized to provide an estimate and range of average room sizes of dwellings. This average room size can then be translated to a total dwelling area using the "number of rooms occupied by a household" variable from the Ghanaian Census. This intermediate step between average dwelling size and number of rooms occupied, fills the missing link that prevents PDT from continually producing new population densities for countries where dwelling size is unavailable through any official means.

Woody, Carson↗

Wind as a Distributed Energy Resource

Distributed wind can be installed in a wide range of locations and wind conditions, supporting millions of systems and thousands of gigawatts of power production capacity. As a result, utilities, communities, and nations are looking to distributed generation as an effective way to meet future energy needs. This fact sheet provides an overview of distributed wind, including where distributed wind projects can be located, and how U.S. and international research supports distributed wind applications. This fact sheet was produced as a resource for the International Energy Agency Task 41 members to use as an educational resource.

behind-the-meter wind energy↗

Characterization of Temperature Heterogeneity in Utility-Scale Power Plant Boilers by Spatially Distributed Ultrasonic Measurements

In extreme environments, even hardened insertion sensors fail quickly. For such environments, we have developed an ultrasonic (US) method for measuring the spatial distribution of temperatures in solid materials and, specifically, across containments of extreme processes. By deploying US sensors in multiple locations, spatial heterogeneity in temperatures inside harsh environments may be characterized. In this note, we update our progress on testing the developed approach in an industrial setting and its performance in describing the temperature distribution inside a 500 MW (electrical) coalfired utility boiler of an electrical power generation plant. We use waveguides (WG) structured to contain echogenic features that produce a train of echoes in response to an excitation pulse. The time of flight between echoes encodes the information on the temperature distribution in the corresponding segment of the WG, which we reconstruct using its parametrization. Five waveguides were welded to the boiler’s heat exchange surface (waterwall) and different locations at the same boiler elevation and produced reliable US waveforms 18 months after the installation. For several weeks during the latest trial, we performed US measurements in five locations spanning half of the boiler’s 14-meter width. The measurements were acquired during regular operation, including load cycling to adjust for demand and intermittent contributions of renewable power sources, and during boiler shutdown for emergency maintenance and the subsequent restart. The interpretation of US waveforms by signal processing resulted in an accurate estimation of temperature distribution along the waveguides. We captured daily cyclical variations in demand-following load. Measurements performed in multiple locations revealed unexpected temperature variations across the boiler. We conclude that an array of developed sensors can provide responsive and spatial temperature measurements while maintaining functionality despite prolonged exposure to an extreme environment.

Walton, Kenneth↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.