Search NASA⌕ Search

SEARCH · Search NASA

Results for “water sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Subcritical Water Extraction of Amino Acids from Atacama Desert Soils

Amino acids are considered organic molecular indicators in the search for extant and extinct life in the Solar System. Extraction of these molecules from a particulate solid matrix, such as Martian regolith, will be critical to their in situ detection and analysis. The goals of this study were to optimize a laboratory amino acid extraction protocol by quantitatively measuring the yields of extracted amino acids as a function of liquid water temperature and sample extraction time and to compare the results to the standard HCl vapor- phase hydrolysis yields for the same soil samples. Soil samples from the Yungay region of the Atacama Desert ( Martian regolith analog) were collected during a field study in the summer of 2005. The amino acids ( alanine, aspartic acid, glutamic acid, glycine, serine, and valine) chosen for analysis were present in the samples at concentrations of 1 - 70 parts- per- billion. Subcritical water extraction efficiency was examined over the temperature range of 30 - 325 degrees C, at pressures of 17.2 or 20.0 MPa, and for water- sample contact equilibration times of 0 - 30 min. None of the amino acids were extracted in detectable amounts at 30 degrees C ( at 17.2 MPa), suggesting that amino acids are too strongly bound by the soil matrix to be extracted at such a low temperature. Between 150 degrees C and 250 degrees C ( at 17.2 MPa), the extraction efficiencies of glycine, alanine, and valine were observed to increase with increasing water temperature, consistent with higher solubility at higher temperatures, perhaps due to the decreasing dielectric constant of water. Amino acids were not detected in extracts collected at 325 degrees C ( at 20.0 MPa), probably due to amino acid decomposition at this temperature. The optimal subcritical water extraction conditions for these amino acids from Atacama Desert soils were achieved at 200 degrees C, 17.2 MPa, and a water- sample contact equilibration time of 10 min.

biomarkers↗

Enhanced Characterization of Microorganisms in the Spacecraft Environment

Spacecraft such as the International Space Station (ISS) and the space shuttles are enclosed environments where crewmembers may spend long periods of time. Currently, crewmembers spend approximately a period of 6 months in the ISS. It is known that these prolonged stays in space may result in weakening of the immune system. Therefore, exposure to opportunistic pathogens or high concentrations of environmental microorganisms may compromise the health of the crew. The detection of biocontaminants in spacecraft environments utilizes culture-based methodology, omitting greater than 90% of all microorganisms including pathogens such as Legionella and Cryptosporidium. Culturable bacteria and fungi have been the only allergens studied; the more potent allergens, such as those from dust mites, have never been tested for in spacecraft environments. In addition, no attempts have been made to monitor microbial toxins in spacecrafts. The present study utilized quantitative polymerase chain reaction (QPCR) as a novel approach for monitoring microorganisms in the spacecraft environment. QPCR is a molecular biology technique that does not rely on the physiological state of the organisms for identification, thereby enabling detection of both culturable and non-culturable organisms. In this project, specific molecular primers and probes were utilized for the detection and quantitation of two fungi of concern in indoor environments, Aspergillus fumigatus and Stachybotrys chartarum. These organisms were selected because of the availability of PCR primers and probes, and to establish the sample processing and analysis methodology that may be employed with additional organisms. Purification methods and QPCR assays were optimized for the detection of these organisms in air, surface, and water; and sample processing and analysis protocols were developed. Preliminary validation of these protocols was conducted in the laboratory with air, surface, and water samples seeded with known concentrations of the target organisms. Additional studies were conducted with bulk materials (HEPA filter pleats and particulate found on the filter screen) obtained from the ISS.

Cruz, Patricia↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Hyporheic, Floodplain, and Surface Water (on Floodplain and River) Geochemical Datasets, and Shapefiles on Meander C at the East River, Colorado

The purpose of this dataset was to sample surface water and groundwater geochemistry at random locations in the East River, Colorado to provide a broad spatial dataset of geochemistry. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. We conducted this random sampling at multiple time points including during the snowmelt flooding stage, during peak flood, during the falling limb of flood, and during baseflow. This datasets contain many datafiles. We include flat text files of surface water geochemistry including surface water on the floodplain and surface water in the river, geochemistry of floodplain pore-water samples, and geochemistry of hyporheic pore-water samples. All datasets are also included as shapefiles so location geochemistry is co-located with sampling locations and sampling depths. This datasets also has the locations of small channels, and hollows that are on top of floodplain Meander C. These small channels funnel surface water from the hillslope through the floodplain and out to the river. All text datasets can be analyzed with software such as Excel or R. All shapefiles can be viewed with freely available R packages such as Leaflet.

54 ENVIRONMENTAL SCIENCES↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Surface Water FTICR-MS, NPOC, TN, Anions, Stable Isotopes, Bacterial Abundance, and Dissolved Inorganic Carbon (v8)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the surface water samples and does not include any results from the sediment. Sediment data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1729719. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in March 2020. It was updated in October 2020 (v2, new and modified files), July 2021 (v3, new and modified files), January 2023 (v4, new and modified files), February 2023 (v5, new and modified files), August 2023 (v6, new and modified files), July 2025 (v7,new and modified files), and August 2026 (v8, new and modified files). Version 8 includes major restructuring of the files and their formats. See the change history section in readme for more details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, and (9) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods, (2) dissolved inorganic carbon (DIC), (3) stable water isotopes (O and H), (4) specific conductivity, (5) total dissolved nitrogen (TN), (6) anions, (7) flow cytometry bacterial abundance data, (8) laboratory methods, and (9) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL, https://www.pnnl.gov/environmental-molecular-sciences-laboratory), and (12) a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .html, .jpg, or .jpeg.

18-O↗

Post-fire time series photos from five sites across the Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2, 2024, affecting all five sites. This dataset provides time series game camera photos, while the broader study includes continuous water quality monitoring, biogeochemical sampling of water and soils, precipitation data, and organic matter analysis. The other data types and additional metadata (include site environmental information) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018020. Because this study is ongoing, this data package will be updated regularly to include newly collected photos. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) field protocol; and (6) folders of game camera photos. The game camera photos are organized by site with subfolders by month of collection. The field metadata contains a subset of the information collected that is most relevant to photo-processing. The full set of field metadata can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018020. All files are .csv, .pdf, or .jpg.

Burn severity↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently three different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS miniature grab sample containers (GSCs) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the current miniature GSCs and Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

Steven W Beck↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health, must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently two different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves for ground analysis. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS mini-grab sample containers (m-GSC) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

William M. King↗

Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

NASA Discipline Environmental Health↗

Constraints on the Mineralogy of Gale Crater Mudstones from MSL SAM Evolved Water

The Sample Analysis at Mars (SAM) and Chemistry and Mineralogy (CheMin) instruments on the Mars Science Laboratory (MSL) have analysed more than 150 micron fines from 14 sites at Gale Crater. Here we focus on the mudstone samples. Two were drilled from sites John Klein (JK) and Cumberland (CB) in the Sheepbed mudstone. Six were drilled from Murray Formation mudstone: Confidence Hills (CH), Mojave (MJ), Telegraph Peak (TP), Buckskin (BK), Oudam (OU), Marimba (MB). SAM's evolved gas analysis mass spectrometry (EGA-MS) detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, and other trace gases, including organic fragments. The identity and evolution temperature of evolved gases can support CheMin mineral detection and place constraints on trace volatile-bearing phases or phases difficult to characterize with X-ray diffraction (e.g., amorphous phases). Here we will focus on SAM H2O data and comparisons to SAM-like analyses of key reference materials.

McAdam, A. C.↗

Evaluation of liquid water measuring instruments in cold clouds sampled during FIRE

Airborne liquid water content (LWC) measurements were conducted with an icing detector and a forward-scattering spectrometer probe during 10 flights into cold clouds, as part of the First ISCCP Research Experiment (FIRE). The LWC measurements thus obtained compare favorably with those from the hot-wire probes in the range where LWC is above the detection limits of the latter; the hot-wire probes have detection thresholds about one order of magnitude higher than is possible with the icing detector and spectrometer probe. FIRE experiment data indicate that LWC should be taken into consideration in cloud studies at temperatures down to at least 35 C.

Heymsfield, Andrew J.↗

Radiolysis of thermally dehydrated gibbsite

Aluminum hydroxide (gibbsite, Al (OH) 3 ) powders and their thermally dehydrated forms were rehydrated and irradiated with gamma rays to examine the effects of the collapse of the crystalline gibbsite structure as it is converted to alumina on the transport of precursors of molecular hydrogen to the surface. The amount of hydrogen gas, H 2 , production from irradiated gibbsite and its transition phases with adsorbed water increased substantially with increasing temperature for dehydration of the samples, up to a point. Furthermore, the production of H 2 for samples without water was considerably lower than the hydrated samples signifying the importance of surface water and the transport of precursors to the surface. EPR spectroscopy showed that the major radiolytic products are trapped electrons and related O – centers. Thermal gravimetric analysis (TGA) measurements of gibbsite dehydration established the temperatures of phase transitions from gibbsite to alumina. Changes to the surface and structure of gibbsite and its transition phases following irradiation were analyzed using nitrogen adsorption, powder X-ray diffraction (pXRD), Raman spectroscopy, electron paramagnetic resonance (EPR), and scanning electron microscopy (SEM). pXRD and Raman spectra showed amorphorization at about 300 °C, coupled to a substantial increase in specific surface area due to increasing porosity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water

The presence of water-ice in the Martian subsurface is a subject of much debate and excited speculation. Recent results from the gammaray spectrometer (GRS) on board NASA's Mars Odyssey spacecraft indicate the presence of large amounts of hydrogen in regions of predicted ice stability. The combination of chemistry, low gravitational field (3.71 m/s(exp 2)) and a surface pressure of about 6.36 mbar at the mean radius, place limits on the stability of H2O on the surface, however, results from the GRS indicate that the hydrogen rich phase may be present at a depth as shallow as one meter in some locations on Mars. The potential for water on Mars leads directly to the speculation that life may once have existed there, since liquid water is the unifying factor for environments known to support life on Earth. Lubricant-free drilling has been considered as a means of obtaining water-rich subsurface samples on Mars, and two recent white papers sponsored by the Mars Program have attempted to identify the problems associated with this goal. The two major issues identified were: the engineering challenges of drilling into a water-soil mixture where phase changes may occur; and the potential to compromise the integrity of in-situ scientific analysis due to contamination, volatilization, and mineralogical or chemical changes as a result of processing. This study is a first attempt to simulate lubricantfree drilling into JSC Mars-1 simulant containing up to 50% water by weight. The goal is to address the following: 1) Does sample processing cause reactions or changes in mineralogy which will compromise the interpretation of scientific measurements conducted on the surface? 2) Does the presence of water-ice in the sample complicate (1)? 3) Do lubricant-free drilling and processing leave trace contaminants which may compromise our understanding of sample composition? 4) How does the torque/power required for drilling change as a function of water content and does this lead to unexpected thermal effects?

Menard, J.↗

Total Water Content Measurements with an Isokinetic Sampling Probe

The NASA Glenn Research Center has developed a Total Water Content (TWC) Isokinetic Sampling Probe. Since it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument is comprised of the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Analysis and testing have been conducted on the subsystems to ensure their proper function and accuracy. End-to-end bench testing has also been conducted to ensure the reliability of the entire instrument system. A Stokes Number based collection efficiency correction was developed to correct for probe thickness effects. The authors further discuss the need to ensure that no condensation occurs within the instrument plumbing. Instrument measurements compared to facility calibrations from testing in the NASA Glenn Icing Research Tunnel are presented and discussed. There appears to be liquid water content and droplet size effects in the differences between the two measurement techniques.

Reehorst, Andrew L.↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

Sink or source? Insights into the behavior of copper and zinc in the sediment porewater of a constructed wetland by peepers

The H-02 free water surface constructed wetland has been applied to remove heavy metals, mainly copper (Cu) and zinc (Zn), from wastewater on the Savannah River Site (Aiken, SC, USA). More and more studies focus on the metal behavior between the sediment and the overlying water, which directly reflects the stability of metals after sedimentation in constructed wetlands. This study focused on the biogeochemical pathways in metal bioavailability and remobilization in the sediment after metals were removed from the overlying water. The dialysis sampling devices (peepers) were used to collect porewater samples from eight depths in the sediment for the measurement of Cu, Zn, dissolved organic carbon (DOC), and major anions (sulfate and chloride). Surface water samples were also collected for the measurement of Cu, Zn, DOC, and anions. Different temporal trends were observed for dissolved Cu between the surface and bottom waters, but not for dissolved Zn. There were no obvious changes in porewater metal concentrations with increasing depths in the sediment. Sediment served as a sink for Cu as only 3% of porewater samples showed higher labile Cu concentrations than the surface water during the entire year. Furthermore, sediment served as a source for Zn in summer and winter as 32% of porewater samples showed higher labile Zn concentrations than the surface water, and these samples were collected at all sediment depths. We think the seasonal changes in the behaviors of Cu and Zn were primarily controlled by the sulfur dynamics and the metal removal processes in the constructed wetland, as well as the different complexing chemistry between Cu and Zn. Also, our study supports that peeper is a powerful tool for studying the biogeochemistry of metals in the sediment.

54 ENVIRONMENTAL SCIENCES↗