Search NASA⌕ Search

SEARCH · Search NASA

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Low Cost Electrostatically Focused TWT

Ring-loop circuits are well known for their simplicity, low cost, compactness, low mass, high gain and efficiency and absence of backward wave oscillations. Peak powers over 20 kw have been achieved. They also have low harmonic output and excellent phase performance. We have developed a double ring-loop circuit that permits electrostatic focusing of an electron beam to at least 0.4 micro pervs. This eliminates the magnet stack and further lowers cost and weight. It permits glass rod fastening of circuit elements as well as gun and collector assemblies, as is done in cathode ray tubes. Using CRT construction techniques, the TWT can be built on automated equipment.

Vancil, Bernard K.↗

Double resonance spectroscopy of multiple-photon excited molecules

Multiple infrared photon absorption is a quite general process which molecules can undergo when placed in a high flux of infrared energy, such as the focussed beam of a CO2 laser. In order to understand how this process works, one must be able to follow the evolution of the molecules through their internal states, populated by photon absorption. Double-resonance spectroscopy is the method of a choice for getting at this information. A system pumped by CO2 laser radiation can be examined with a tunable laser probe beam, such as that from a lead-salt diode laser. From such an experiment, one can directly observe Rabi modulation of the absorption lines, determine elementary state-to-state relaxation pathways, and locate higher excited vibrational states. Systems currently under investigation include SF6 and vinyl chloride. In suitable cases, the probe beam can be a tunable visible or UV source, such as a dye laser. Fluorescence spectroscopy can then be used to monitor the transient absorptions produced by multiple-photon excitation. Among the systems which can be examined are biacetyl and glyoxal.

Steinfeld, J. I.↗

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗

Shear fatigue crack growth - A literature survey

Recent studies of shear crack growth are reviewed, emphasizing test methods and data analyses. The combined mode I and mode II elastic crack tip stress fields are considered. The development and design of the compact shear specimen are described, and the results of fatigue crack growth tests using compact shear specimens are reviewed. The fatigue crack growth tests are discussed and the results of inclined cracks in tensile panels, center cracks in plates under biaxial loading, cracked beam specimens with combined bending and shear loading, center-cracked panels and double edge-cracked plates under cyclic shear loading are examined and analyzed in detail.

Liu, H. W.↗

A double layer model for solar X-ray and microwave pulsations

The wide range of wavelengths over which quasi-periodic pulsations have been observed suggests that the mechanism causing them acts upon the supply of high energy electrons driving the emission processes. A model is described which is based upon the radial shrinkage of a magnetic flux tube. The concentration of the current, along with the reduction in the number of available charge carriers, can rise to a condition where the current demand exceeds the capacity of the thermal electrons. Driven by the large inductance of the external current circuit, an instability takes place in the tube throat, resulting in the formation of a potential double layer, which then accelerates electrons and ions to MeV energies. The double layer can be unstable, collapsing and reforming repeatedly. The resulting pulsed particle beams give rise to pulsating emission which are observed at radio and X-ray wavelengths.

Tapping, K. F.↗

An imaging system for PLIF/Mie measurements for a combusting flow

The equipment required to establish an imaging system can be divided into four parts: (1) the light source and beam shaping optics; (2) camera and recording; (3) image acquisition and processing; and (4) computer and output systems. A pulsed, Nd:YAG-pummped, frequency-doubled dye laser which can freeze motion in the flowfield is used for an illumination source. A set of lenses is used to form the laser beam into a sheet. The induced fluorescence is collected by an UV-enhanced lens and passes through an UV-enhanced microchannel plate intensifier which is optically coupled to a gated solid state CCD camera. The output of the camera is simultaneously displayed on a monitor and recorded on either a laser videodisc set of a Super VHS VCR. This videodisc set is controlled by a minicomputer via a connection to the RS-232C interface terminals. The imaging system is connected to the host computer by a bus repeater and can be multiplexed between four video input sources. Sample images from a planar shear layer experiment are presented to show the processing capability of the imaging system with the host computer.

Wey, C. C.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

One-Joule-per-Pulse Q-Switched 2-micron Solid State Laser

Q-switched output of 1.1 J per pulse at 2-micron wavelength has been achieved in a diode pumped Ho:Tm:LuLF laser using a side-pumped rod configuration in a Master-Oscillator-Power-Amplifier (MOPA) architecture. This is the first time that a 2-micron laser has broken the Joule per pulse barrier for Q-switched operation. The total system efficiency reaches 5% and 6.2% for single and double pulse operation, respectively. The system produces excellent 1.4 times of transform limited beam quality.

Yu, Jirong↗

Double-focusing mass spectrometer

Device uses lighter, easily alined, magnet assembly to provide field required to interact with ion beam. It has no separate duct; instead, evacuated duct is formed by pole pieces which support vacuum pump. Magnetic gap and magnet assembly are reduced from 4.64 to 2.54 mm and from 2.4 to 1.5 kg, respectively.

Giffin, C. E.↗

The Effect of Temperature on Faceplate/Core Delamination in Composite/Titanium Sandwich Plates

A study was made of the delamination behavior of sandwich beams made of titanium core bonded to face-plates that consisted of carbon fiber reinforced polymer composite. Nominally mode I behavior was considered at 23C and 180C, by making use of a specially reinforced double cantilever (DCB) specimens. The toughness of the bond between the faceplate and the core was determined on the basis of a beam on elastic foundation analysis. The specimen compliance, and toughness were all independent of temperature in these relatively short-term experiments. The fracture mechanism showed temperature dependence, due to the hygrothermal sensitivity of the adhesive.

Liechti, Kenneth M.↗

Millimeter-wave double-dipole antennas for high-gain integrated reflector illumination

A double-dipole antenna backed by a ground plane has been fabricated for submillimeter wavelengths. The double-dipole antenna is integrated on a thin dielectric membrane with a planar detector at its center. Measured feed patterns at 246 GHz agree well with theory and demonstrate a rotationally symmetric pattern with high coupling efficiency to Gaussian beams. The input impedance is around 50 ohms, and will match well to a Schottky diode or SIS detector. The double-dipole antenna served as the feed for a small machined parabolic reflector. The integrated reflector had a measured gain of 37 dB at 119 microns. This makes the double-dipole antenna ideally suited as a feed for high resolution tracking or for long focal length Cassegrain antenna systems.

Filipovic, Daniel F.↗

Si(Li) position sensitive detector

A position sensitive detector was made using the lithium diffused layer of a lithium-drifted-silicon detector as the uniform resistive layer. An expression is derived for estimating the resistance from the thickness of the lithium layer. Expressions for the noise and ballistic deficit for single differentiation-double integration pulse shaping are presented. Room temperature data for a 1 Mev proton beam on a 45 mm long detector shows that the linearity is better than .05% and that the position resolution is 1.06 + or - .05 mm.

Gigante, J. R.↗

Molecular-Beam-Epitaxy Program

Molecular Beam Epitaxy (MBE) computer program developed to aid in design of single- and double-junction cascade cells made of silicon. Cascade cell has efficiency 1 or 2 percent higher than single cell, with twice the open-circuit voltage. Input parameters include doping density, diffusion lengths, thicknesses of regions, solar spectrum, absorption coefficients of silicon (data included for 101 wavelengths), and surface recombination velocities. Results include maximum power, short-circuit current, and open-circuit voltage. Program written in FORTRAN IV.

Sparks, Patricia D.↗

Aircraft-based radiometric imaging of tropospheric temperature and precipitation using the 118.75-GHz oxygen resonance

Passive microwave imaging of O2 emissions using the 118.75-GHz resonance has been investigated for tropospheric and stratospheric remote sensing of atmospheric temperature and precipitation. An imaging millimeter-wave spectrometer (MTS) using eight double-sideband channels centered around the 118.75-GHz resonance, and including a fixed-beam 53.65-GHz radiometer and video camera was constructed. The MTS collected data during 33 flights of the NASA-ER-2 high-altitude aircraft in 1986 during GALE and Cohmex, yielding the first high-spatial-resolution microwave images of atmospheric O2 brightness. The isolated 118-GHz line offers higher spatial resolution and precipitation sensitivity than O2 lines in the 5-mm band near 60 GHz. The brightness temperature perturbations of clouds in nonprecipitating regions are typically twice as large in the 118-GHz channels. However, observations over cirrus anvils show that the 118-GHz brightnesses are not adversely sensitive to some optically opaque cloud cover. Thus these channels are expected to be useful for temperature sounding in the presence of clouds, although retrieval ambiguities can result from variations in the water-vapor profile and surface emissivity.

Gasiewski, A. J.↗

Airborne lidar research

The planetary boundary layer (PBL) is the lowest layer of the atmosphere in contact with the Earth's surface. It plays an important role in atmospheric circulation and dynamics by influencing surface fluxes of moisture, heat, and momentum. The PBL is characterized by its turbulence structure. Organized convection within the PBL may generate gravity waves within the free troposphere. These waves can propagate vertically, modifying global circulation. Remote sensing of the PBL using a downward-looking lidar is providing new insight into dynamic processes of this important layer and its connection with wave generation. An airborne lidar is an ideal tool to study the PBL. The lidar is installed on the NASA Electra aircraft. It consists of a frequency doubled Nd:YAG laser aligned with a 40 cm diameter telescope. As the laser beam propagates downward from the aircraft toward the surface, it is scattered by the aerosols and molecules in the atmosphere. Generally, there is a sharp gradient of aerosol scattering associated with the PBL top, with high aerosol scattering from within the PBL, and generally very low scattering from the free atmosphere above. It is this gradient in aerosol scattering that is used to visualize the structure of the PBL. A small portion of the scattered radiation is collected by the telescope, filtered, detected by a photomultiplier, and digitized at 100 nsec rate. The horizontal resolution is typically around 13 m, using a 10 Hz laser and a nominal aircraft moves, the resolution of features in the atmosphere below the aircraft is about 15 x 13 m. Results from several studies are presented and discussed.

Melfi, S. Harvey↗

Evidence of auroral plasma cavities at Uranus and Neptune from radio burst observations

Radio bursts originating from the stronger magnetic polar regions of both Uranus and Neptune were detected by the planetary radio astronomy experiment during the Voyager 2 encounters with the planets. It has previously been demonstrated that these bursts are beamed into a broad, hollow emission pattern from their auroral sources. It is now shown that the bursts at both planets also manifest similar detailed patterns, with the waves beamed into two separate and distinct radiation cones at intermediate wave frequencies. This double-cone emission pattern is predicted by relativistic cyclotron resonance theory, and application of this theory to the observed emission pattern yields the plasma density structure within the radio source region. Calculations indicate that at both Uranus and Neptune the plasma-to-cyclotron frequency ratio can drop well below 0.01 within the active region. Such low values indicate that the southern auroral zones at both planets contain an auroral plasma cavity that is similar to that found in earth's nightside auroral zone.

Farrell, W. M.↗

Advanced Precipitation Radar Antenna to Measure Rainfall From Space

To support NASA s planned 20-year mission to provide sustained global precipitation measurement (EOS-9 Global Precipitation Measurement (GPM)), a deployable antenna has been explored with an inflatable thin-membrane structure. This design uses a 5.3 5.3-m inflatable parabolic reflector with the electronically scanned, dual-frequency phased array feeds to provide improved rainfall measurements at 2.0-km horizontal resolution over a cross-track scan range of up to 37 , necessary for resolving intense, isolated storm cells and for reducing the beam-filling and spatial sampling errors. The two matched radar beams at the two frequencies (Ku and Ka bands) will allow unambiguous retrieval of the parameters in raindrop size distribution. The antenna is inflatable, using rigidizable booms, deployable chain-link supports with prescribed curvatures, a smooth, thin-membrane reflecting surface, and an offset feed technique to achieve the precision surface tolerance (0.2 mm RMS) for meeting the low-sidelobe requirement. The cylindrical parabolic offset-feed reflector augmented with two linear phased array feeds achieves dual-frequency shared-aperture with wide-angle beam scanning and very low sidelobe level of -30 dB. Very long Ku and Ka band microstrip feed arrays incorporating a combination of parallel and series power divider lines with cosine-over-pedestal distribution also augment the sidelobe level and beam scan. This design reduces antenna mass and launch vehicle stowage volume. The Ku and Ka band feed arrays are needed to achieve the required cross-track beam scanning. To demonstrate the inflatable cylindrical reflector with two linear polarizations (V and H), and two beam directions (0deg and 30deg), each frequency band has four individual microstrip array designs. The Ku-band array has a total of 166x2 elements and the Ka-band has 166x4 elements with both bands having element spacing about 0.65 lambda(sub 0). The cylindrical reflector with offset linear array feeds reduces the complexity from "NxN" transmit/receive (T/R) modules of a conventional planar-phased array to just "N" T/R modules. The antenna uses T/R modules with electronic phase-shifters for beam steering. The offset reflector does not provide poor cross-polarization like a double- curved offset reflector would, and it allows the wide scan angle in one plane required by the mission. Also, the cylindrical reflector with two linear array feeds provides dual-frequency performance with a single, shared aperture. The aperture comprises a reflective surface with a focal length of 1.89 m and is made from aluminized Kapton film. The reflective surface is of uniform thickness in the range of a few thousandths of an inch and is attached to the chain-link support structure via an adjustable suspension system. The film aperture rolls up, together with the chain-link structure, for launch and can be deployed in space by the deployment of the chain-link structure.

Rahmat-Samii, Yahya↗