Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescent probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Ultrafast X-Ray Probes of Elementary Molecular Events

Elementary events that determine photochemical outcomes and molecular functionalities happen on the femtosecond and subfemtosecond timescales. Among the most ubiquitous events are the nonadiabatic dynamics taking place at conical intersections. These facilitate ultrafast, nonradiative transitions between electronic states in molecules that can outcompete slower relaxation mechanisms such as fluorescence. The rise of ultrafast X-ray sources, which provide intense light pulses with ever-shorter durations and larger observation bandwidths, has fundamentally revolutionized our spectroscopic capabilities to detect conical intersections. Recent theoretical studies have demonstrated an entirely new signature emerging once a molecule traverses a conical intersection, giving detailed insights into the coupled nuclear and electronic motions that underlie, facilitate, and ultimately determine the ultrafast molecular dynamics. Following a summary of current sources and experiments, we survey these techniques and provide a unified overview of their capabilities. We discuss their potential to dramatically increase our understanding of ultrafast photochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NIRDye 812: A molecular platform tailored for multimodal bioimaging applications of targeted fluorescence- and photoacoustic-guided surgery

The primary treatment for malignant tumors remains to be surgical removal of the diseased tissue. The presence or absence of residual diseased tissue at the tumor margin is the strongest predictor of postoperative prognosis and recurrence. Accordingly, reliance on the ability of surgeons to visually distinguish diseased tissue from healthy tissue unambiguously in real time is crucial. Near infrared-I (NIRsingle bondI) fluorescence-emitting targeting biomolecular constructs such as anticancer antibody-fluorophore conjugates, namely cetuximab-IRDye® 800CW (CTB-IRDye® 800CW), are FDA-approved for clinical trial usage in the fluorescence-guided resection of diseased tissue due to affording improved direct visualization of tumor tissue when compared to the use of either the unaided eye under standard white light illumination (WLI) surgical techniques or non-targeting fluorophores. Unfortunately, though helpful, CTB-IRDye® 800CW affords limited (i) identification of diseased tissue and (ii) tumor margin delineation, because the immunoconjugate generates suboptimal tumor-to-background ratios (TBRs) as a result of its spectral/photophysical profiles poorly aligning with the fixed optical windows of pre-/clinical setups. As such, CTB-IRDye® 800CW is more prone to affording incomplete resection compared to if TBRs were higher due to otherwise. Here, to aid in accurately identifying deep-seated diseased tissue, photoacoustic (PA) tomography has been implemented alongside CTB-IRDye® 800CW to achieve PA signals that could result in higher TBRs. However, in clinical trial practice, using IRDye® 800CW for PA imaging also yields subpar TBRs due to it affording low PA signals. To overcome such limitations, we developed NIRDye 812, a structurally-modified topological equivalent of IRDye® 800CW, to confer it the capability to yield both higher TBRs and superior PA signal than that of the equivalent CTB-conjugate and fluorophore IRDye® 800CW itself, respectively. To do so, we substituted the oxygen atom at its meso-position with a sulfur atom. CTB-NIRDye 812 demonstrated a red-shifted absorption wavelength at 796 nm and a peak NIR-I fluorescence emission wavelength at 820 nm, which better dovetails with the fixed windows of preinstalled fixed emission filters within commercial pre-/clinical NIR-I fluorescence imaging instruments. Overall, CTB-NIRDye 812 provided a ~ 2-fold increase in TBRs compared to those of CTB-IRDye® 800CW in vivo. Also, NIRDye 812 displayed an ~60% higher PA signal than that of IRDye® 800CW. Collectively, we achieved our goal of improving upon the spectral/photophysical and PA properties of IRDye® 800CW via introducing a subtle modification to its electronic core such that its CTB immunoconjugate could potentially allow for fast track or breakthrough designation by the FDA due to its near-identical structure displaying considerably improved efficacy.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Laser-induced-fluorescence imaging of a spin-polarized ultracold neutral plasma in a magnetic field

In this work, we report Doppler-sensitive laser-induced-fluorescence (LIF) imaging of an ultracold neutral plasma in a magnetic field. Local values of ion density, hydrodynamic fluid velocity, temperature, and spin polarization are obtained using a fluorescence model based on velocity-resolved rate equations (REs) including the transfer of ions between states due to laser coupling and spontaneous emission. The RE approach captures optical pumping of ions into states that are not driven by the LIF excitation laser, and this is validated with experimental data. Combined molecular-dynamics and quantum-trajectories simulations verify that velocity-changing collisions have a negligible impact on the state population evolution for typical experimental conditions. Relative intensities of Zeeman components of the LIF spectra provide clear evidence that the ions are electron-spin-polarized when created by photoionization of magnetically trapped 88 Sr atoms. This probe opens many possibilities for studying thermal transport and the equilibration of neutral plasmas in overlapping regimes of strong coupling and magnetization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field imaging in a laboratory plasma

In laboratory plasmas, arrays of probes have typically been used to measure the evolution of the magnetic field topology. Here, we present initial image-based measurements of the magnetic topology in a low-temperature plasma using a purely optical diagnostic. Laser induced fluorescence measurements of neutral velocity distribution functions are made using a fast camera, imaging the Zeeman splitting of σ-peaks in neutral argon. The separation of σ-peaks provides spatially resolved magnetic field magnitude measurements with a detection threshold on the order of 10 G

36 MATERIALS SCIENCE↗

EVAP: A two-photon imaging tool to study conformational changes in endogenous Kv2 channels in live tissues

A primary goal of molecular physiology is to understand how conformational changes of proteins affect the function of cells, tissues, and organisms. Here, we describe an imaging method for measuring the conformational changes of the voltage sensors of endogenous ion channel proteins within live tissue, without genetic modification. We synthesized GxTX-594, a variant of the peptidyl tarantula toxin guangxitoxin-1E, conjugated to a fluorophore optimal for two-photon excitation imaging through light-scattering tissue. We term this tool EVAP (Endogenous Voltage-sensor Activity Probe). GxTX-594 targets the voltage sensors of Kv2 proteins, which form potassium channels and plasma membrane–endoplasmic reticulum junctions. GxTX-594 dynamically labels Kv2 proteins on cell surfaces in response to voltage stimulation. To interpret dynamic changes in fluorescence intensity, we developed a statistical thermodynamic model that relates the conformational changes of Kv2 voltage sensors to degree of labeling. We used two-photon excitation imaging of rat brain slices to image Kv2 proteins in neurons. We found puncta of GxTX-594 on hippocampal CA1 neurons that responded to voltage stimulation and retain a voltage response roughly similar to heterologously expressed Kv2.1 protein. Our findings show that EVAP imaging methods enable the identification of conformational changes of endogenous Kv2 voltage sensors in tissue.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray fluorescence mapping: Insights into mesoscale structure impact on battery functional electrochemistry

Abstract Electron transfer and ion transport occurs over multiple-length scales ranging from the atomic to mesoscale within battery materials and electrodes. Micro-X-ray fluorescence (µ-XRF) is an important characterization tool as it can resolve structural, compositional, and redox information while providing insight into the spatial distribution of an electroactive material. In this work, µ-XRF mapping is used to probe the distribution of iron within thin planar slurry-based and thick porous carbon nanotube (CNT)-based magnetite (Fe 3 O 4 ) electrodes. Notably, the porous CNT-based electrode showed homogenous distribution of Fe within the electrode whereas the planar electrode demonstrated distinct Fe aggregates. This information was used to rationalize the electrochemistry observed by cyclic voltammetry and galvanostatic cycling. The thick porous electrode delivered 215% more capacity per gram of magnetite during the first discharge, consistent with increased electrode homogeneity enabling effective ion access and electron transfer. Graphical Abstract

Sadique, Nahian↗

Aggregation‐Induced Stimulated Emission of 100% Dye Microspheres

Dyes with aggregation-induced emission (AIE) properties have gained interest due to their bright luminescence in solid-state aggregates. While fluorescence from AIE dyes is widely exploited, relatively little is known about aggregation-induced stimulated emission. Here, stimulated emission of tetraphenylethene (TPE)-based organoboron AIE dyes, TPEQBN, in thin films and in microcavity lasers is investigated. Using femtosecond pump–probe spectroscopy, gain coefficients up to 230 cm -1 at 500 nm are measured. Using rate equations, concentration- and pump-dependent gain dynamics as well as laser build-up dynamics are analyzed. During laser oscillation, radiative stimulated emission allows high instantaneous quantum yield greater than 90% to be achieved. Solid-state microspheres made of 100% AIE dyes are fabricated via microfluidic emulsion and solvent evaporation method. Coupled with high gain and high refractive index of 1.76, microspheres as small as 2 µm in diameter show lasing by nanosecond pumping with a threshold of ≈10 pJ µm –2 . Polymer coated, but not bare, microspheres are internalized by live cells and generate narrowband cavity-mode emission from within the cytoplasm. This work shows the potential of AIE dyes as laser materials.

36 MATERIALS SCIENCE↗

Photometric sensing of heavy metal ions using a naphthoquinodimethyl- bis -thioamide dye: Selectivity & photophysics of the metal organic complexes

As Mother Nature is experiencing catastrophic environmental pollutions from both natural sources and anthropogenic activities, many scientists have been working around the clock to develop environmentally benign and cost-effective, yet sensitive, detection techniques for pollutants, especially heavy metal species (e.g. lead, cadmium, mercury, among others) that are deleterious to human health. Herein, we report a novel sulfur-containing small organic dye/sensor naphthoquinodimethyl-bis-thioamide (QDM), which was found to be particularly selective toward mercury ion (Hg 2+ ). Using a combination of UV-vis absorption, photoluminescence, and time-resolved pump-probe techniques, we established that QDM and Hg 2+ can form stable complex(es) due to the strong affinity of sulfur toward mercury. In this investigation, while a higher ratio of QDM:Hg 2+ was necessary to fully quench the fluorescence emission of QDM, only 1 equiv of the Hg 2+ ion was necessary to observe the sensing effect on the excited state photo-behavior(s) of QDM. Furthermore, the present results highlight a synergy between molecular sensors' selectivity/sensitivity and sensor-analytes dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Intrusive Laser-Induced Imaging for Speciation and Patternation in High Pressure Gas Turbine Combustors

The next generation of was turbine combustors for aerospace applications will be required to meet increasingly stringent constraints on fuel efficiency, noise abatement, and emissions. The power plants being designed to meet these constraints will operate at extreme conditions of temperature and pressure, thereby generating unique challenges to the previously employed diagnostic methodologies. Current efforts at NASA Glenn Research Center (GRC) utilize optically accessible, high pressure flametubes and sector combustor rigs to probe, via advanced nonintrusive laser techniques, the complex flowfields encountered in advanced combustor designs. The fuel-air mixing process is of particular concern for lowering NO(x) emissions generated in lean, premixed engine concepts. Using planar laser-induced fluorescence (PLIF) we have obtained real-time, detailed imaging of the fuel spray distribution for a number of fuel injector over a wide range of operational conditions that closely match those expected in the proposed propulsion systems. Using a novel combination of planar imaging, of fuel fluorescence and computational analysis that allows an examination of the flowfield from any perspective, we have produced spatially and temporally resolved fuel-air distribution maps. These maps provide detailed insight into the fuel injection at actual conditions never before possible, thereby greatly enhancing the evaluation of fuel injector performance and combustion phenomena.

Locke, Randy J.↗

Near-Field Spectroscopy with Nanoparticles Deposited by AFM

An alternative approach to apertureless near-field optical spectroscopy involving an atomic-force microscope (AFM) entails less complexity of equipment than does a prior approach. The alternative approach has been demonstrated to be applicable to apertureless near-field optical spectroscopy of the type using an AFM and surface enhanced Raman scattering (SERS), and is expected to be equally applicable in cases in which infrared or fluorescence spectroscopy is used. Apertureless near-field optical spectroscopy is a means of performing spatially resolved analyses of chemical compositions of surface regions of nanostructured materials. In apertureless near-field spectroscopy, it is common practice to utilize nanostructured probe tips or nanoparticles (usually of gold) having shapes and dimensions chosen to exploit plasmon resonances so as to increase spectroscopic-signal strengths. To implement the particular prior approach to which the present approach is an alternative, it is necessary to integrate a Raman spectrometer with an AFM and to utilize a special SERS-active probe tip. The resulting instrumentation system is complex, and the tasks of designing and constructing the system and using the system to acquire spectro-chemical information from nanometer-scale regions on a surface are correspondingly demanding.

Anderson, Mark S.↗

Tre-DST: A Drug Susceptibility Test for Mycobacterium tuberculosis Using Solvatochromic Trehalose Probes

In 2024, an estimated 10 million people developed Tuberculosis (TB), nearly half a million of whom were infected with drug-resistant tuberculosis (DR-TB). Early detection of infection and drug resistance enables rapid engagement in effective care. Bacterial culture and nucleic acid testing remain the primary diagnostic methods, with smear microscopy being phased out. However, these methods present significant limitations for diagnosing drug resistance, such as lengthy time-to-result for phenotypic tests, as well as the need for prior knowledge of resistance mutations and prohibitive cost for molecular tests. To address this, we developed a rapid phenotypic TB drug susceptibility test, termed Tre-DST, based on novel metabolically incorporated trehalose probes, which specifically detect live mycobacteria. We used the nonpathogenic Mycobacterium smegmatis and the virulence-attenuated Mycobacterium tuberculosis (Mtb) H37Ra or auxotrophic Mtb to demonstrate a strong correlation between cost-effective plate reader results and flow cytometry data, suggesting that the plate reader is a suitable fluorescence detector for Tre-DST. We determined that adding a 1-week incubation step allowed Mtb samples originally seeded at 10 4 CFU/mL to become detectable, over 2 weeks earlier than colony-forming unit analysis. We found that Tre-DST reports on drug susceptibility in a drug-agnostic manner, demonstrating loss of fluorescence with frontline TB drugs as well as the newer drug bedaquiline. Tre-DST distinguished RIF- and INH-resistant auxotrophs from susceptible controls and accurately reported the resistance activity. Ultimately, because Tre-DST is agnostic to mechanisms of drug resistance, this assay is likely compatible with all WHO-recommended and future DR-TB drugs as a diagnostic in reference laboratories.

diagnostics↗

Photocatalyzed electron exchange between organic chromophores and hematite nanoparticles and the role of solid-state charge transport

Understanding photocatalyzed redox interactions between Fe(III)–(oxyhydr)oxide mineral nanoparticles and adsorbed chromophoric organic matter is critical for accurately predicting bioavailable iron fluxes in the euphotic zone of natural aquatic systems, and for improving the effectiveness of nano-iron-based water purification systems. However, the electron transfer processes that underpin photoreductive dissolution at particle/organic/solution interfaces occur on ultrafast timescales and thus remain difficult to probe. In this work, we report an ultrafast transient absorption spectroscopy (TAS) study of suspensions of hematite nanoplatelets (HNPs) sensitized by adsorbed rhodamine B (RhB) dye as a function of solution media and pH. The TAS results indicate a substantially longer fluorescence lifetime of RhB adsorbed on HNPs across a wide range of pH conditions, consistent with transient photoinduced electron transfer to the oxide with recombination kinetics controlled by electron migration back to the interface via small polaron hopping. Normalization of the observed kinetics to the measured surface loading of RhB at different pH values shows that the recombination rates are insensitive to environmental variables, likely controlled instead by particle properties that determine small polaron diffusion behavior.

54 ENVIRONMENTAL SCIENCES↗

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology: Enabling In Situ Aerosol Science for Small Spacecraft Missions

AERACEPT is an early-stage technology combining an entry vehicle and descent probe in a single aeroshell instrumented for aerosol particle sampling.This approach combines previous technology demonstrations of sampling through an aeroshell body and well-established particle sampling techniques from airborne science with modern advances in thermal protection materials such as 3D woven carbon-carbon and HEEET. It is designed to be compatible with robust, fast cadence, low power, small footprint analysis instruments such as LIBS, SERS, and UV fluorescence. It is particularly well suited to a Venus mission, as the particles of interest will be in the subsonic regime of a passive descent, and is included as part of the Nephele Venus small spacecraft mission concept.

aerosol↗

An algorithm for computing chlorophyll-a concentrations using a dual-frequency fluorosensor

An algorithm to be used on data from a dual-frequency fluorosensor (i.e. one using two wavelengths for excitation of chlorophyll-a fluorescence) to compute total chlorophyll-a concentration and to partition that chlorophyll between two color groups present in a mixed phytoplankton population is described. The algorithm is based on laboratory and field-testing experience gained with the airborne lidar oceanographic probing experiment fluorosensor.

Campbell, J. W.↗

Shinkolobweite, from the Shinkolobwe Mine, Democratic Republic of Congo: A New Mineral Containing Uranium in the Rare Pentavalent Oxidation State

ABSTRACT Shinkolobweite, Pb1.333[U5+O(OH)(UO2)5O4.67(OH)5.33](H2O)5, is a new lead uranyl oxide-hydroxide hydrate mineral containing hexavalent and pentavalent uranium from the Shinkolobwe mine, Democratic Republic of Congo. Crystals of shinkolobweite are dark reddish-brown prisms up to 0.5 mm in length, occurring on a matrix of massive uraninite associated with fourmarierite, rutherfordine, soddyite, and sklodowskite. Crystals are translucent with subadamantine luster and light bronze-yellow streak, are flattened on {010}, are elongated on [001], and exhibit the forms {100}, {010}, {101}, and . The mineral is non-fluorescent under both longwave and shortwave ultraviolet illumination. It has a Mohs hardness of ∼2 and exhibits brittle tenacity with perfect cleavage on {010}, imperfect cleavage on {100}, and even fracture. The calculated density is 5.853 g/cm3 based on the empirical formula. Electron probe microanalysis provided the empirical formula Pb1.290U6+4.876U5+1.166O27H16.633 based on 27 O apfu and U5+:U6+ determined by X-ray photoelectron spectroscopy. Shinkolobweite is orthorhombic, superspace group Pnnm(0b0)000, a = 14.4808(4), b = 7.0681(8), c = 11.9423(3) Å, V = 1222.32(15) Å3, modulation wave vector [0 1/3 0], and Z = 2. The structure was refined from 8959 reflections to a final R1 = 0.0736 for all reflections. Uranyl oxide-hydroxide sheets in shinkolobweite adopt the β-U3O8 topology and possess (3 + 1) commensurately modulated ordering that results from the long-range ordering of U5+ and U6+ in the sheet, as well as the position and occupancy of interlayer Pb2+ cations. Observations of a topological transition between α-U3O8 and β-U3O8 type sheets in shinkolobweite supplements our understanding of U5+ mineral oxidation and stability.

Mineralogy↗

Exploring Local Vibrational Structure in Protein-Bound Chlorophyll a: Isotope-Enrichment Experiments and Electrostatic Analysis

Local chlorophyll (Chl) vibrations play an essential role in biological photosynthesis by facilitating rapid energy transfer between pigments. In research studies, they also provide a useful spectroscopic probe of the local protein environment that surrounds each pigment. However, measuring the complete vibrational absorption spectrum of a protein-bound Chl molecule is much more difficult than, for example, Chl in neat solvent due to overlap with protein vibrations that typically drown out Chl vibrational features. Resonance Raman and fluorescence spectroscopies provide a way around this problem for Franck–Condon active vibrations, but these often rely on cryogenic measurement conditions and fail to capture vibrational signatures from, e.g., ester-group vibrations that lack coupling to a convenient electronic transition. In the present contribution, we use 13 C-enrichment of the protein backbone to shift protein background signals to lower frequency, providing a largely clean spectral window in which to study local Chl a C═O stretch modes. A room-temperature absorption spectrum for Chl a in the water-soluble chlorophyll protein (WSCP) of Lepidium virginicum is thus extracted as a difference between protein-plus-pigment and protein-only vibrational spectra. Excellent agreement in the molecular fingerprint region with the vibrational spectrum of Chl a in organic solvents confirms that the resulting spectrum represents the response of the protein-bound Chl a molecule. Furthermore, the ester group resonance is observed to shift in response to the S53P mutation that eliminates a 17 3 ester group hydrogen bond from the protein environment. Finally, we analyze these experimental results using MD-based electrostatic analysis, finding that electric-field mapping at the C atom of the ester group provides a satisfactory explanation for the observed frequency shifts between organic solvent and protein environment. MD analysis further suggests that a red-shifted ester peak observed experimentally for the S53P mutant results from solvation of the 17 3 Chl ester group due increase water penetration into the Chl-binding pocket relative to wild-type WSCP. Here, we anticipate that these results will prove useful both for benchmarking future simulation work and as a reference for interpreting Chl vibrational spectra as a probe of pigment–protein interactions.

14 SOLAR ENERGY↗

Radiogenic transformation of human mammary epithelial cells in vitro

Cancer induction by space radiations is a major concern for manned space exploration. Accurate assessment of radiation risk at low doses requires basic understanding of mechanism(s) of radiation carcinogenesis. For determining the oncogenic effects of ionizing radiation in human epithelial cells, we transformed a mammary epithelial cell line (185B5), which was immortalized by benzo(a)pyrene, with energetic heavy ions and obtained several transformed clones. These transformed cells showed growth properties on Matrigel similar to human mammary tumor cells. To better understand the mechanisms of radiogenic transformation of human cells, we systematically examined the alterations in chromosomes and cancer genes. Among 16 autosomes examined for translocations, by using fluorescence in situ hybridization (FISH) technique, chromosomes 3, 12, 13, 15, 16, and 18 appeared to be normal in transformed cells. Chromosomes 1, 4, 6, 8, and 17 in transformed cells, however, showed patterns different from those in nontransformed cells. Southern blot analyses indicated no detectable alterations in myc, ras, Rb, or p53 genes. Further studies of chromosome 17 by using in situ hybridization with unique sequence p53 gene probe and a centromere probe showed no loss of p53 gene in transformed cells. Experimental results from cell fusion studies indicated that the transforming gene(s) is recessive. The role of genomic instability and tumor suppressor gene(s) in radiogenic transformation of human breast cells remains to be identified.

NASA Center JSC↗