Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

A Climatology of Midlatitude Continental Clouds from the ARM SGP Central Facility: Cloud Fraction and Radiative Forcing - Part II

Data collected at the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) central facility are analyzed for determining the variability of cloud fraction and radiative forcing at several temporal scales between January 1997 and December 2002. Cloud fractions are estimated for total cloud cover and for single-layer low (0-3 km), middle (3-6 km), and high clouds (greater than 6 km) using ARM SGP ground-based paired lidar-radar measurements. Shortwave (SW), longwave (LW), and net cloud radiative forcings (CRF) are derived from up- and down-looking standard precision spectral pyranometers and precision infrared radiometer measurements. The annual averages of total, and single-layer, nonoverlapped low, middle and high cloud fractions are 0.49, 0.11, 0.03, and 0.17, respectively. Total and low cloud amounts were greatest from December through March and least during July and August. The monthly variation of high cloud amount is relatively small with a broad maximum from May to August. During winter, total cloud cover varies diurnally with a small amplitude, mid-morning maximum and early evening minimum, and during summer it changes by more than 0.14 over the daily cycle with a pronounced early evening minimum. The diurnal variations of mean single-layer cloud cover change with season and cloud height. Annual averages of all-sky, total, and single-layer high, middle, and low LW CRFs are 21.4, 40.2, 16.7, 27.2, and 55.0 Wm(sup -2), respectively; and their SW CRFs are -41.5, -77.2, -37.0, -47.0, and -90.5 Wm(sup -2). Their net CRFs range from -20 to -37 Wm(sup -2). For all-sky, total, and low clouds, the maximum negative net CRFs of -40.1, -70, and -69.5 Wm(sup -2), occur during April; while the respective minimum values of -3.9, -5.7, and -4.6 Wm(sup -2), are found during December. July is the month having maximum negative net CRF of -46.2 Wm(sup -2) for middle clouds, and May has the maximum value of -45.9 Wm(sup -2) for high clouds. An uncertainty analysis demonstrates that the calculated CRFs are not significantly affected by the difference between clear-sky and cloudy conditions. A more comprehensive cloud fraction study from both surface and satellite observations will follow.

Dong, Xiquan↗

Gravity recovery analysis using GPS for STEP and a low-low satellite mission

Global Positioning System (GPS) receivers on low Earth orbiting satellites can provide three-dimensional global tracking with sub-decimeter orbit accuracy. The precise GPS data can additionally be used to refine the Earth's gravity field. Satellite Test of the Equivalence Principle (STEP) is a proposed European Space Agency mission which will carry a flight GPS receiver. Using a realistic scenario for processing 5 days of GPS data, a covariance analysis is performed to obtain the expected improvement in the gravity field. Additionally, a similar analysis is then repeated for two low Earth orbiting satellites, each equipped with GPS receivers and with precise ranging measurements between them.

Muellerschroen, Ronald J.↗

Far-infrared and submillimeter-wavelength observations of star-forming dense cores. I - Spectra

Far-infrared and submillimeter photometry of 10 low-mass star formation regions containing embedded IRAS sources is presented. These new observations define the peak of the spectral energy distributions of these objects and provide more precise estimates of their bolometric luminosities. Two new sources, L1527 and L483, are among the reddest known low-mass objects, with spectral energy distribution peaks at 100-200 microns and extremely steep IRAS slopes. These cold sources have spectra which are similar to blackbodies of 30-40 K but have significant excess emission on the Wien side. Models of the spectral energy distributions using a spherically symmetric core structure indicate that these sources have visual extinctions greater than 1000 mag. However, models with these large extinctions predict too little near-infrared emission. A nonspherically symmetric distribution of circumstellar material may play a role in the generation of the extra near-infrared emission.

Ladd, E. F.↗

ORION S-band data acquisition for S-Y calibration

Error sources in the Operational Radio Interferometry Observing Network (ORION) are addressed. Specifically, the performance of the S-band receiver and the optimum allocation of data volume between S- and X-band observations is studied. It is found that the requirements on the S-band receiver are not very stringent. The system temperature of the ORION S-band receiver has a very small effect on baseline determination accuracy. It is unwise to pay a high cost for an S-band receiver with a low system temperature; a system temperature as high as 240 K is tolerable. Only 20 to 40 percent of data volume is to be allocated to S-band observations for minimum baseline error. The error remains low over a rather wide range of data volume ratio. Hence precise allocation of the 14 pairs of the Mark 3 very long base interferometer data channels between S- and X-band observations is not critical.

Wu, S. C.↗

High performance liquid chromatographic hydrocarbon group-type analyses of mid-distillates employing fuel-derived fractions as standards

Two high performance liquid chromatographic (HPLC) methods have been developed for the determination of saturates, olefins and aromatics in petroleum and shale derived mid-distillate fuels. In one method the fuel to be analyzed is reacted with sulfuric acid, to remove a substantial portion of the aromatics, which provides a reacted fuel fraction for use in group type quantitation. The second involves the removal of a substantial portion of the saturates fraction from the HPLC system to permit the determination of olefin concentrations as low as 0.3 volume percent, and to improve the accuracy and precision of olefins determinations. Each method was evaluated using model compound mixtures and real fuel samples.

Seng, G. T.↗

Steps toward 8m honeycomb mirror blanks. III - 1.8m honeycomb sandwich blanks cast from borosilicate glass

The design, fabrication techniques, and equipment used for producing two 1.8-m honeycomb sandwich blanks, eventually leading to production of 8-m blanks, are reported. The procedure employed 85 cast hexagonal tiles at the bottom section, affixed against flotation by SiC bolts. The two plano concave mirrors are 1.83 m thick, weight 500 kg, and are each designed for 19 supports of astatic-lever type. Both blanks are of high quality and with an adequately low bubble content; one is to be figured to high-precision 0.25-arcsecond images, and is to be tested on the Multiple Mirror Telescope. Construction of a spin-casting facility based on the same principle is being planned for test-fabricating spin-cast mirrors on a smaller scale.

Angel, J. R. P.↗

A laser interferometer dilatometer for thermal expansion measurements of composites

A high precision Fizeau type, laser interferometer dilatometer system has been developed for low expansion composite materials. The strain resolution is about 1 microstrain. The system is automated to operate over a large temperature range and record data during the test in real time. A technique has been developed to reduce the fringe data in real time to length changes. The dilatometer system is described and thermal expansion measurements for several fiber-reinforced and particle filled composites are presented.

Tompkins, S. S.↗

Communicating through deep space

NASA's Deep Space Network (DSN) consists of a worldwide set of communication stations and a central control facility in California, enabling communication with spacecraft thousands of millions of miles from earth. The stations have gone from 26 m diameter antennas operating at 960 MHz to 70 m diameter (by 1988) at 8400 MHz. The DSN provides exceptional performance in high gain steerable antennas, ultra-low noise receivers, high power transmitters, frequency and time standards, and precise radio metric data. Spacecraft missions envisaged in the 1990's for the continuing exploration of the Solar System include an array of increasingly complex visits to the inner planets, asteroids and comets and the outer planets. The Deep Space Network planned for the mid-1980s may not meet all the needs of these missions without substantial change. Deep space stations may require conversion to operation with beam waveguides, higher frequency and relative frequency stability of 10 to the -16th. A deep space relay station in earth orbit could permit operation at higher frequencies, with attendant higher performance. Long range planning to select the appropriate future network configurations and develop the technologies essential to their implementation is underway.

Smith, J. G.↗

PROBE (Precision Reflector Orbital Build Experiment): A proposed flight experiment to study EVA assembly of precision segmented reflectors

PROBE (Precision Reflector Orbital Build Experiment) is a Shuttle flight demonstration experiment designed to study extravehicular activity (EVA) assembly of precision segmented reflectors. PROBE will support missions being considered for NASA's Global Change Technology Initiative as well as other missions in astrophysics and spacecraft optical communications requiring large precision reflectors. Such reflectors are envisioned to consist of a low-mass backup truss to which the optical surface is attached. Because of their large size, these reflectors will be constructed on-orbit from smaller pieces which can be packaged in the launch vehicle. The technology to be developed with PROBE also has application for construction of solar dynamic collectors which are planned for the enhanced configuration of Space Station Freedom. Viewgraphs of PROBE are presented.

Heard, Walter↗

Quantifying Vegetation Change in Semiarid Environments: Precision and Accuracy of Spectral Mixture Analysis and the Normalized Difference Vegetation Index

Because in situ techniques for determining vegetation abundance in semiarid regions are labor intensive, they usually are not feasible for regional analyses. Remotely sensed data provide the large spatial scale necessary, but their precision and accuracy in determining vegetation abundance and its change through time have not been quantitatively determined. In this paper, the precision and accuracy of two techniques, Spectral Mixture Analysis (SMA) and Normalized Difference Vegetation Index (NDVI) applied to Landsat TM data, are assessed quantitatively using high-precision in situ data. In Owens Valley, California we have 6 years of continuous field data (1991-1996) for 33 sites acquired concurrently with six cloudless Landsat TM images. The multitemporal remotely sensed data were coregistered to within 1 pixel, radiometrically intercalibrated using temporally invariante surface features and geolocated to within 30 m. These procedures facilitated the accurate location of field-monitoring sites within the remotely sensed data. Formal uncertainties in the registration, radiometric alignment, and modeling were determined. Results show that SMA absolute percent live cover (%LC) estimates are accurate to within ?4.0%LC and estimates of change in live cover have a precision of +/-3.8%LC. Furthermore, even when applied to areas of low vegetation cover, the SMA approach correctly determined the sense of clump, (i.e., positive or negative) in 87% of the samples. SMA results are superior to NDVI, which, although correlated with live cover, is not a quantitative measure and showed the correct sense of change in only 67%, of the samples.

Elmore, Andrew J.↗

Petit Grand Tour: Mission Concepts to Outer Planet Satellites Using Non-Conic Low Energy Trajectories

Our Solar System is connected by a vast Interplanetary Superhighway System (ISSys) providing low energy transport throughout. The Outer Planets with their satellites and rings are smaller replicas of the Solar System with their own ISSys, also providing low energy transport within their own satellite systems. This low energy transport system is generated by all of the Lagrange points of the planets and satellites within the Solar System. Figures show the tubular passage-ways near L1 of Jupiter and the ISSys of Jupiter schematically. These delicate and resilient dynamics may be used to great effect to produce free temporary captures of a spacecraft by a planet or satellite, low energy interplanetary and inter-satellite transfers, as well as precision impact orbits onto the surface of the satellites. Additional information is contained in the original extended abstract.

Lo, M. W.↗

Estimating the Libration of Mercury by Remote Sensing of Gravity and Altimetry

One of the most intriguing scientific questions about Mercury is whether the planet possesses a liquid core. One way that this can be ascertained is through the measurement of the longitudinal libration of Mercury about its rotation axis. The MESSENGER (Mercury Surface, Space, Environment, Geochemistry, and Ranging) mission to Mercury will attempt this measurement by deriving the rotation of the planet from remotely sensed observations of the Mercury gravity field and the planet's shape. For a fully fluid core the libration is expected to be an approximately 350-m-amplitude oscillation (at the equator) about the mean rotation of the planet. Thus, the shape of the planet undergoes a librational oscillation in the same way that features on the surface participate in the motion. In this sense altimetric topography can be considered analogous to imaging, with the important exception that for altimetry, the long wavelengths corresponding to low degrees and orders in a spherical harmonic expansion, can be precisely determined from orbital measurements. The rotation of the planet thus introduces a time dependence of the topographic image in an inertial (i.e. fixed) reference frame and the libration is a variation in the planetary rotation rate, manifest as an oscillation of the topographic image. Similarly, gravity measures the distribution of mass within a planet and as such can be viewed as providing a vertically integrated 'image' of the internal density structure. For a librating planet the gravitational field will also reveal a variation in the rotation rate, manifest as an oscillation of the field with respect to an inertial reference frame. While the long-wavelength gravity field contains contributions from the radial distribution of mass with depth, the long wavelength terms are most sensitive to the mass distribution of the deep interior. Thus, both the topography and the gravity independently can be used to determine the (irregular) rotation of a planet, although the topographical method measures the rotation of the crust while the gravity measures the rotation of the distributed mass, and these are not necessarily identical. For example, for a planet that contains a fluid outer core that is effectively decoupled from the mantle the gravity field will not librate in the manner of a solid body. The libration obtained from the variable rotation of the gravity field will represent a combination of contributions due to a librating mantle and a differentially rotating fluid core. Differential rotation of the Earth's inner core had been theoretically predicted from three dimensional geodynamical models and subsequently reported from seismic observations. A difference between the libration of the lithosphere as determined from altimetry and the deep interior as determined from gravity, if it could be detected, might provide further insight into the nature of core-mantle coupling. Additional information is contained in the original extended abstract.

Smith, D. E.↗

Cross-sectional structural parameters from densitometry

Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section along the length of the scan. Various aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of cross-sectional properties. Factors considered included X-ray photon energy, initial scan orientation, the angle spanned by the three scans (included angle), and I(min)/I(max) ratios. Principal moments of inertia were accurate to within +/-3.1% and principal angles were within +/-1 degrees of the expected value for phantoms scanned with included angles of 60 degrees and 90 degrees at the higher X-ray photon energy (140 kVp). Low standard deviations in the error (0.68-1.84%) also indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 degrees. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (I(min)/I(max)) values when various included angles are used make this technique viable for future in vivo studies.

NASA Center ARC↗

A Stainless-Steel Mandrel for Slumping Glass X-ray Mirrors

We have fabricated a precision full-cylinder stainless-steel mandrel at Marshall Space Flight Center. The mandrel is figured for a 30-cm diameter primary (paraboloid) mirror of an 840-cm focal-length Wolter-1 telescope. We have developed this mandrel for experiments in slumping.thermal forming at about 600 C.of glass mirror segments at Goddard Space Flight Center, in support of NASA's participation in the International X-ray Observatory (IXO). Precision turning of stainless-steel mandrels may offer a low-cost alternative to conventional figuring of fused-silica or other glassy forming mandrels. We report on the fabrication, metrology, and performance of this first mandrel; then we discuss plans and goals for stainless-steel mandrel technology.

Gubarev, Mikhail V.↗

Forward voltage short-pulse technique for measuring high power laser array junction temperature

The present invention relates to a method of measuring the temperature of the P-N junction within the light-emitting region of a quasi-continuous-wave or pulsed semiconductor laser diode device. A series of relatively short and low current monitor pulses are applied to the laser diode in the period between the main drive current pulses necessary to cause the semiconductor to lase. At the sufficiently low current level of the monitor pulses, the laser diode device does not lase and behaves similar to an electronic diode. The voltage across the laser diode resulting from each of these low current monitor pulses is measured with a high degree of precision. The junction temperature is then determined from the measured junction voltage using their known linear relationship.

Meadows, Byron L.↗

Performance Simulations for a Spaceborne Methane Lidar Mission

Future spaceborne lidar measurements of key anthropogenic greenhouse gases are expected to close current observational gaps particularly over remote, polar, and aerosol-contaminated regions, where actual in situ and passive remote sensing observation techniques have difficulties. For methane, a "Methane Remote Lidar Mission" was proposed by Deutsches Zentrum fuer Luft- und Raumfahrt and Centre National d'Etudes Spatiales in the frame of a German-French climate monitoring initiative. Simulations assess the performance of this mission with the help of Moderate Resolution Imaging Spectroradiometer and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations of the earth's surface albedo and atmospheric optical depth. These are key environmental parameters for integrated path differential absorption lidar which uses the surface backscatter to measure the total atmospheric methane column. Results showthat a lidar with an average optical power of 0.45W at 1.6 μm wavelength and a telescope diameter of 0.55 m, installed on a low Earth orbit platform(506 km), will measure methane columns at precisions of 1.2%, 1.7%, and 2.1% over land, water, and snow or ice surfaces, respectively, for monthly aggregated measurement samples within areas of 50 × 50 km2. Globally, the mean precision for the simulated year 2007 is 1.6%, with a standard deviation of 0.7%. At high latitudes, a lower reflectance due to snow and ice is compensated by denser measurements, owing to the orbital pattern. Over key methane source regions such as densely populated areas, boreal and tropical wetlands, or permafrost, our simulations show that the measurement precision will be between 1 and 2%.

methane↗