Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2018)

For FY18, Savannah River National Laboratory (SRNL) focused on four main tasks in its study of corrosion of Hanford Double-Shell Tanks (DSTs). The New Limits task focused on the development of a pitting factor as a localized corrosion predictor. Electrochemical experiments were directed towards pitting factors between 1 and 2 (i.e., borderline conditions) and separating the effects of chloride and fluoride in the pitting factor equation. In addition, long term immersion testing experiments with partial and completely immersed coupons in solutions with a wide range of pitting factors were tested. Secondary liner studies continued this year with a new vapor corrosion inhibition (VCI) strategy in which ground water (GW) simulants at a specified concentration of commercial VCI were mixed. The specific concentrations were recommended by Cortec® and was compared with similar concentration of GW with calcium carbonate. The anodic drift task utilized a simulant corresponding to AN-107 waste tank chemistry. The chemistry was studied with three different surface conditions: mill-scale, partial mill-scale and ground to 600 grit to study the impact of different surfaces on the potential drift. The final task was focused on ammonia concentration determination of a vapor space corrosion (VSC) test vessel using Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detector. A summary of each task is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Performance of 700 Series Stellite Alloys in Various Media

The corrosion performance of 700 series Stellite alloys including Stellite 706, Stellite 712 and Stellite 720, which are high-carbon high-molybdenum Stellite alloys, in various media such as Green Death solution, 3.5 wt.% NaCl solution and morpholine solution with pH 9.5, is studied using electrochemical and immersion methods. The obtained polarization curves are analyzed along with the corroded surfaces examined using SEM/EDS to investigate the corrosion mechanisms of these alloys. The experimental results reveal that the 700 series Stellite alloys possess excellent corrosion resistance in the tested media, even in the severe corrosive condition—Green Death solution at 60 °C where no noticeable pitting is found on the surfaces of the alloys. It is shown that the corrosion resistance of these Stellite alloys depends strongly on the behavior of the passivation film formed on the alloy surfaces. Additional Mo content in these alloys benefits the stabilization of the passivation film thus enhances the corrosion resistance of the alloys. Both carbon and molybdenum contents affect the passivation film formation and stabilization.

36 MATERIALS SCIENCE↗

Corrosion Behavior of Q235 Steel Exposed in Deepwater of South China Sea

For the first time, the corrosion behavior of Q235 steel in 1200, 2000 and 3000 m deepwater of South China Sea for 0.5 year was reported in this study. The corrosion morphology and corrosion products properties were investigated using different techniques, such as 3D optical microscope, scanning electron microscope, x-ray diffraction analyzer and electrochemical impedance spectroscopy. The main environmental factors influencing the corrosion rate of Q235 in deep sea were discussed by applying gray relational analysis. The results indicated that uniform thinning occurred after exposure. A large number of tiny pits were distributed under the corrosion products with a two-layer structure. The corrosion rate and average pitting depth of samples exposed at 2000 m were lower than those exposed at 1200 and 3000 m, and the main environmental factors determining the variation of corrosion rate at different depths were temperature and dissolved oxygen concentration. Hydrostatic pressure had slight effect on the corrosion rate of Q235 steel, but promoted the formation of a more uniform corrosion morphology.

36 MATERIALS SCIENCE↗

Relative Humidity and the Susceptibility of Austenitic Stainless Steel to Stress Corrosion Cracking in an impure Plutonium Oxide Environment

Laboratory tests to investigate the corrosivity of moist plutonium oxide/chloride salt mixtures on 304L and 316L stainless steel coupons showed that corrosion occurred in selected samples. The tests exposed flat coupons for pitting evaluation and 'teardrop' stressed coupons for stress corrosion cracking (SCC) evaluation at room temperature to various mixtures of PuO{sub 2} and chloride-bearing salts for periods up to 500 days. The exposures were conducted in sealed containers in which the oxide-salt mixtures were loaded with about 0.6 wt % water from a humidified helium atmosphere. Observations of corrosion ranged from superficial staining to pitting and SCC. The extent of corrosion depended on the total salt concentration, the composition of the salt and the moisture present in the test environment. The most significant corrosion was found in coupons that were exposed to 98 wt % PuO{sub 2}, 2 wt % chloride salt mixtures that contained calcium chloride and 0.6 wt% water. SCC was observed in two 304L stainless steel teardrop coupons exposed in solid contact to a mixture of 98 wt % PuO{sub 2}, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl{sub 2}. The cracking was associated with the heat-affected zone of an autogenous weld that ran across the center of the coupon. Cracking was not observed in coupons exposed to the headspace gas above the solid mixture, or in coupons exposed to other mixtures with either no CaCl{sub 2} or 0.92 wt% CaCl{sub 2}. SCC was present where the 0.6 wt % water content exceeded the value needed to fully hydrate the available CaCl{sub 2}, but was absent where the water content was insufficient. These results reveal the significance of the relative humidity in the austenitic stainless steels environment to their susceptibility to corrosion. The relative humidity in the test environment was controlled by the water loading and the concentration of the hydrating salts such as CaCl{sub 2}. For each salt or salt mixture there is a threshold relative humidity below which the necessary liquid electrolyte cannot exist, and therefore below which the SCC risk is very low. This threshold is a thermodynamic quantity known as the deliquescence relative humidity that is dependent on the identity of the salt but is independent of the quantity of salt. Below the deliquescence RH there should be low corrosion risk, and above it the corrosion risk increases rapidly as a liquid phase, which is initially saturated with salt, grows and becomes more widespread in the container.

36 MATERIALS SCIENCE↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

Beneficial effect of copper on pitting resistance of Ni-Cr-Fe alloys

This study examines the effect of copper alloying on pitting resistance in a model solid solution FCC Ni-13%Cr-10%Fe alloy through potentiodynamic and potentiostatic polarization in 0.1 M NaCl in conjunction with an analysis using first-principles competitive electro-chemisorption modeling. The pitting potential increased with increasing Cu content in the alloy. Furthermore, the extent of metastable pit growth was suppressed and the incubation time for metastable to stable pit transition increased with Cu content. The first-principles competitive adsorption calculations suggested that Cu alloying suppresses chloride ion adsorption on the alloy surface in a simulated pit environment, which inhibits active dissolution at the pit bottom, enhances proton adsorption, and thereby increases the local pH at the pit bottom. In conclusion, we propose that these two effects of Cu in solid solution combine to reduce pit stability and may act in addition to the enrichment of Cu on the corroding pit surface.

36 MATERIALS SCIENCE↗

The Shape Factor for Pits and Its Impact on Pit Stability

This study employs the finite element method (FEM) to predict the impact of pit shape on pit stability via shape factors of various pit geometries relevant to localized corrosion. Lower values of the shape factor indicate an increased ease in maintaining pit stability. Analyzed geometries include undercut pits, bispherical pit-within-pit structures, and covered pits with perforated (lacy) covers. The effect of the water layer thickness, transport properties of the electrolyte inside and outside the pit, and cathode location on the pit shape factor were also explored. Results show that occluded pits exhibit lower shape factors than open ones, with disk-shaped pits decreasing further as c/r ratio and occlusion angle increase. The findings also suggest minimal influence from a secondary pit if the primary remains active. An equation is presented that quantifies the impact of lacy covers, revealing significant shape factor value reduction. Additionally, high salt concentrations inside pits have a limited stabilizing effect compared to geometry, while thin water layers and adjacent cathodic/sinks reduce pit stability.

Shehi, A. (ORCID:0009000271548041)↗

Localized corrosion behavior of a single-phase non-equimolar high entropy alloy

In another work, a design method combining computational modeling and empirical knowledge has been reported to establish a more efficient paradigm for developing future corrosion resistant alloys. Using this approach, a single-phase non-equimolar high entropy alloy (HEA) was successfully designed and synthesized. In this work, a detailed experimental investigation of the localized corrosion behavior of this alloy is presented. The HEA was found to possess superior intrinsic pitting resistance and exhibit strong passivity, even in 6 M HCl. The ability of this HEA to initiate and propagate a pit has been studied. The pitting resistance was shown to result from the formation of a passive film with exceedingly strong resistance to breakdown and from a high resistance to pit propagation. Pitting was discovered to be significantly inhibited because of the extremely strong passivity, even in solutions with lower pH and higher chloride concentration than found in a typical local pit environment. The outstanding properties of the HEA validate the approach used for designing corrosion-resistant HEAs.

36 MATERIALS SCIENCE↗

In situ corrosion analysis of Al-Zn-In-Mg-Ti-Ce sacrificial anode alloy

The corrosion behaviour of Al-5Zn-0.02In-1Mg-0.05Ti-0.5Ce (wt.%) alloy has been investigated by immersion test, scanning electron microscopy, energy dispersive X-ray detector, electrochemical impedance spectroscopy and electrochemical noise. The results show that there exist different corrosion types of the alloy in 3.5% NaCl solution with the immersion time. At the initial stage of immersion, pitting due to the precipitates predominates the corrosion with a typical inductive loop at low frequencies in electrochemical impedance spectroscopy. The major precipitates of the alloy are MgZn{sub 2} and Al{sub 2}CeZn{sub 2} particles. The corrosion potentials of the bulk MgZn{sub 2} and Al{sub 2}CeZn{sub 2} alloys are negative with respect to that of {alpha}-Al, so the MgZn{sub 2} and Al{sub 2}CeZn{sub 2} precipitates can act as activation centre and cause the pitting. In the late corrosion, a relative uniform corrosion predominates the corrosion process controlled by the dissolution/precipitation of the In ions and characterized by a capacitive loop at medium-high frequencies in electrochemical impedance spectroscopy. The potential noise of the pitting shows larger amplitude fluctuation and lower frequency, but the potential noise of the uniform corrosion occurs with smaller amplitude fluctuation and higher frequency.

36 MATERIALS SCIENCE↗

Determining Drying Conditions to Mitigate Hanford Double Shell Storage Tank Underside Corrosion — Phase 1

The Hanford Site in Washington State has legacy radiological waste that is being retrieved from single shell tanks (SSTs) and transferred to newer, double shell tanks (DSTs) for eventual closure of the SSTs. The waste is maintained in the DSTs until eventual immobilization can be performed at the Waste Treatment and Immobilization Plant (WTP), currently under construction. Until full immobilization is complete, extended service of the DSTs must be ensured by mitigating corrosion of the steel tank walls and buried steel pipelines. A Pit Air Supply System has been developed to mitigate corrosion of the leak detection pits connected to the concrete foundations of the DSTs. The objectives for the present study are: (i) to corrode steel specimens in an electrolytic simulant to form artificial pits with specific pit depths, and (ii) to determine the temperature and humidity levels that will mitigate further pit growth. Experimental work and results will be presented to evaluate conditions associated with the PASS system and predict corrosion rates when the PASS is operating.

Atmospheric Corrosion↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Launch Pad Coatings for Smart Corrosion Control

Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability. Researchers at NASA's Corrosion Technology Laboratory at KSC are developing a smart, environmentally friendly coating system for early corrosion detection, inhibition, and self healing of mechanical damage without external intervention. This smart coating will detect and respond actively to corrosion and mechanical damage such as abrasion and scratches, in a functional and predictable manner, and will be capable of adapting its properties dynamically. This coating is being developed using corrosion sensitive microcapsules that deliver the contents of their core (corrosion inhibiting compounds, corrosion indicators, and self healing agents) on demand when corrosion or mechanical damage to the coating occurs.

Calle, Luz M.↗

Hanford Double Shell Waste Tank Corrosion Studies - Final Report FY2015

During FY15, SRNL performed corrosion testing that supported Washington River Protection Solutions (WRPS) with their double shell tank (DST) integrity program. The testing investigated six concerns including, 1) the possibility of corrosion of the exterior of the secondary tank wall; 2) the effect of ammonia on vapor space corrosion (VSC) above waste simulants; 3) the determination of the minimum required nitrite and hydroxide concentrations that prevent pitting in concentrated nitrate solutions (i.e., waste buffering); 4) the susceptibility to liquid air interface (LAI) corrosion at proposed stress corrosion cracking (SCC) inhibitor concentrations; 5) the susceptibility of carbon steel to pitting in dilute solutions that contain significant quantities of chloride and sulfate; and 6) the effect of different heats of A537 carbon steel on the corrosion response. For task 1, 2, and 4, the effect of heat treating and/ or welding of the materials was also investigated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The corrosion behavior of the T1 (Al2CuLi) intermetallic compound in aqueous environments

The intermetallic compound T1 (Al2CuLi) is suspected to play an important role in the localized corrosion at subgrain boundaries in Al-Li-Cu alloys. The intermetallic was synthesized for characterization of its corrosion behavior. Experiments performed included open circuit potential measurements, potentiodynamic polarization, and corrosion rate vs. pH in solutions whose pH was varied over the range of 3 to 11. Subgrain boundary pitting and continuous subgrain boundary corrosion are discussed in terms of the data obtained. Evidence suggesting the dealloying of copper from this compound is also presented.

Buchheit, R. G.↗

DEGRADATION EVALUATION OF HEAVY WATER DRUMS AND TANKS

Heavy water with varying chemistries is currently being stored in over 6700 drums in L- and K-areas and in seven tanks in L-, K-, and C-areas. A detailed evaluation of the potential degradation of the drums and tanks, specific to their design and service conditions, has been performed to support the demonstration of their integrity throughout the desired storage period. The 55-gallon drums are of several designs with Type 304 stainless steel as the material of construction. The tanks have capacities ranging from 8000 to 45600 gallons and are made of Type 304 stainless steel. The drums and tanks were designed and fabricated to national regulations, codes and standards per procurement specifications for the Savannah River Site. The drums have had approximately 25 leakage failures over their 50+ years of use with the last drum failure occurring in 2003. The tanks have experienced no leaks to date. The failures in the drums have occurred principally near the bottom weld, which attaches the bottom to the drum sidewall. Failures have occurred by pitting, crevice and stress corrosion cracking and are attributable, in part, to the presence of chloride ions in the heavy water. Probable degradation mechanisms for the continued storage of heavy water were evaluated that could lead to future failures in the drum or tanks. This evaluation will be used to support establishment of an inspection plan which will include susceptible locations, methods, and frequencies for the drums and tanks to avoid future leakage failures.

36 MATERIALS SCIENCE↗

Erosion-Corrosion Analysis of Tank 241-AW-02E Feed Pump Pit Jumpers B-2 and 1-4 Removed from Service in 2013 (Final Report)

This document is the final report summarizing the results in the examination of two pipe sections (jumpers) from the tank 241-AW-02E feed pump pit in the 241-AW tank farm. These pipe section samples consisted of jumper AW02E-WT-J-[B – 2] and jumper AW02E-WT-J-[1 – 4]. For the remainder of this report, these jumpers will be referred to as B – 2 and 1 – 4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion detection and evaluation

Report details comprehensive study of nondestructive methods for detecting and/or evaluating up to six different types of corrosion: general, galvanic filiform, pitting, intergranular, and stress. Studied methods include: visual/optical inspection, radiography, penetrant inspection, analysis by polarized light, electrical conductivity measurements, pH analysis, and ultrasonic inspection.

Kammerer, C. C.↗