Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

47 OTHER INSTRUMENTATION↗

SU-E-T-260: Development of a System to Verify for Connection Consistency in a Brachytherapy

Purpose: Brachytherapy has multiple manual procedures which are prone to human error, especially during the connection process of the treatment device to applicator. This is when considerable attention is required. In this study, we propose a new connection verification device concept. Methods: The system is composed of a ring magnet (anisotropic ferrite : magfine Inc), hole device (A1324LUA-T : Allegro MicroSystems Phil Inc) and an in-house check cable, which is made from magnetic material (Figure1). The magnetic field distribution is affected by the check cable position and any magnetic field variation is detected by the hole device. This system frequency is 20Hz and the average of 4 signals was used as hole device value to reduce noise. Results: The value of the hole device is altered, depending on the location of the check cable. The resolution of the check cable position is 5mm and 10mm, around a 10mm region from the hole device and over 10mm, respectively. There was a reduction in sensitivity of the hole device, in our test, which was linked to the distance of the hole device from the check cable. Conclusion: We demonstrated a new concept of connection verification in a brachytherapy. This system has the possibility to detect an incorrect connection. Moreover, the system is capable of self-optimization, such as determining the number of hole device and the magnet strength.Acknowledgement:This work was supported by JSPS Core -to-Core program Number 23003 and KAKENHI Grant Number 26860401. This work was supported by JSPS Core-to-Core program Number 23003 and KAKENHI Grant Number 26860401.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aminobenzoic Acid Derivatives Obstruct Induced Fit in the Catalytic Center of the Ribosome

The Escherichia coli (E. coli) ribosome can incorporate a variety of non-l-α-amino acid monomers into polypeptide chains in vitro but with poor efficiency. Although these monomers span a diverse set of compounds, there exists no high-resolution structural information regarding their positioning within the catalytic center of the ribosome, the peptidyl transferase center (PTC). Thus, details regarding the mechanism of amide bond formation and the structural basis for differences and defects in incorporation efficiency remain unknown. Within a set of three aminobenzoic acid derivatives–3-aminopyridine-4-carboxylic acid (Apy), ortho-aminobenzoic acid (oABZ), and meta-aminobenzoic acid (mABZ)–the ribosome incorporates Apy into polypeptide chains with the highest efficiency, followed by oABZ and then mABZ, a trend that does not track with the nucleophilicity of the reactive amines. Here, we report high-resolution cryo-EM structures of the ribosome with each of these three aminobenzoic acid derivatives charged on tRNA bound in the aminoacyl-tRNA site (A-site). The structures reveal how the aromatic ring of each monomer sterically blocks the positioning of nucleotide U2506, thereby preventing rearrangement of nucleotide U2585 and the resulting induced fit in the PTC required for efficient amide bond formation. They also reveal disruptions to the bound water network that is believed to facilitate formation and breakdown of the tetrahedral intermediate. Together, the cryo-EM structures reported here provide a mechanistic rationale for differences in reactivity of aminobenzoic acid derivatives relative to l-α-amino acids and each other and identify stereochemical constraints on the size and geometry of non-monomers that can be accepted efficiently by wild-type ribosomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Pilot tone as a key to improving the spatial resolution of eBPMs

At Elettra, the Italian synchrotron light source, an internal project has been started to develop an electron beam position monitor capable of achieving sub-micron resolution with a self-compensation feature. In order to fulfil these requirements, a novel RF front end has been designed. A high isolation coupler combines the input signals with a known pilot tone which is generated by the readout system. This allows the parameters of the four channels to be continuously calibrated, by compensating the different responses of each channel. A similar technique is already known, but for the first time experimental results have shown the improvement in resolution due to this method. The RF chain was coupled with a 4-channel digitizer based on 160 MHz, 16 bits ADCs and an Altera Stratix FPGA. At first, no additional processing was done in the FPGA, collecting only the raw data from the ADCs; the position was calculated through the FFT of each signal. A simulation was also performed to verify the analytic relation between spatial resolution and signal-to-noise ratio; this was very useful to better understand the behaviour of the system with different sources of noise (aperture jitter, thermal noise, etc.). The experimental data were compared with the simulation, showing indeed a perfect agreement with the latter and confirming the capability of the system to reach sub-micrometric accuracy. Therefore, the use of the pilot tone greatly improves the quality of the system, correcting the drifts and increasing the spatial resolution by a factor of 4 in a time window of 24 hours.

43 PARTICLE ACCELERATORS↗

Polarization effects in thallium bromide x-ray detectors

We present the results of a detailed experimental study of polarization effects in thallium bromide planar x-ray detectors. Measurements were carried out in the range 10-100 keV by scanning a highly focused x-ray beam, 50 {mu}m in diameter, from a synchrotron source across the detector. Above a certain radiation threshold the detector response showed a systematic degradation of its spectroscopic characteristics, peak channel position, peak height, and energy resolution. Using a pump-and-probe technique, we studied the dynamics of spectral degradation, the spatial extent and relaxation of the polarized region, and the dependence of the detector response on bias voltage and temperature. For comparison, we modeled polarization effects induced by the charging of traps by both electrons and holes using a model based on recent theoretical work of Bale and Szeles. We calculated the charge collection efficiency and spectral line shapes as functions of exposure time, beam position, count rate, and photon energy, and obtained credible agreement with experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary neutron diffraction analysis of challenging human manganese superoxide dismutase crystals

Superoxide dismutases (SODs) are enzymes that protect against oxidative stress by dismutation of superoxide into oxygen and hydrogen peroxide through cyclic reduction and oxidation of the active-site metal. The complete enzymatic mechanisms of SODs are unknown since data on the positions of hydrogen are limited. Here, methods are presented for large crystal growth and neutron data collection of human manganese SOD (MnSOD) using perdeuteration and the MaNDi beamline at Oak Ridge National Laboratory. The crystal from which the human MnSOD data set was obtained is the crystal with the largest unit-cell edge (240 Å) from which data have been collected via neutron diffraction to sufficient resolution (2.30 Å) where hydrogen positions can be observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution‐dependent behavior of subgrid‐scale vertical transport in the Z hang‐ M c F arlane convection parameterization

Abstract To better understand the behavior of quasi‐equilibrium‐based convection parameterizations at higher resolution, we use a diagnostic framework to examine the resolution‐dependence of subgrid‐scale vertical transport of moist static energy as parameterized by the Zhang‐McFarlane convection parameterization (ZM). Grid‐scale input to ZM is supplied by coarsening output from cloud‐resolving model (CRM) simulations onto subdomains ranging in size from 8 × 8 to 256 × 256 km 2 . Then the ZM‐based parameterization of vertical transport of moist static energy for scales smaller than the subdomain size ( ) are compared to those directly calculated from the CRM simulations ( ) for different subdomain sizes. The ensemble mean decreases by more than half as the subdomain size decreases from 128 to 8 km across while decreases with subdomain size only for strong convection cases and increases for weaker cases. The resolution dependence of is determined by the positive‐definite grid‐scale tendency of convective available potential energy (CAPE) in the convective quasi‐equilibrium (QE) closure. Further analysis shows the actual grid‐scale tendency of CAPE (before taking the positive definite value) and behave very similarly as the subdomain size changes because they are both tied to grid‐scale advective tendencies. We can improve the resolution dependence of significantly by averaging the grid‐scale tendency of CAPE over an appropriately large area surrounding each subdomain before taking its positive definite value. Even though the ensemble mean decreases with increasing resolution, its variability increases dramatically. cannot capture such increase in the variability, suggesting the need for stochastic treatment of convection at relatively high spatial resolution (8 or 16 km).

54 ENVIRONMENTAL SCIENCES↗

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameter-space metric of semicoherent searches for continuous gravitational waves

Continuous gravitational-wave (CW) signals such as emitted by spinning neutron stars are an important target class for current detectors. However, the enormous computational demand prohibits fully coherent broadband all-sky searches for prior unknown CW sources over wide ranges of parameter space and for yearlong observation times. More efficient hierarchical ''semicoherent'' search strategies divide the data into segments much shorter than one year, which are analyzed coherently; then detection statistics from different segments are combined incoherently. To optimally perform the incoherent combination, understanding of the underlying parameter-space structure is requisite. This problem is addressed here by using new coordinates on the parameter space, which yield the first analytical parameter-space metric for the incoherent combination step. This semicoherent metric applies to broadband all-sky surveys (also embedding directed searches at fixed sky position) for isolated CW sources. Furthermore, the additional metric resolution attained through the combination of segments is studied. From the search parameters (sky position, frequency, and frequency derivatives), solely the metric resolution in the frequency derivatives is found to significantly increase with the number of segments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale, electrified liquid jets for high resolution printing of charge.

Nearly all research in micro- and nanofabrication focuses on the formation of solid structures of materials that perform some mechanical, electrical, optical, or related function. Fabricating patterns of charges, by contrast, is a much less well explored area that is of separate and growing interesting because the associated electric fields can be exploited to control the behavior of nanoscale electronic and mechanical devices, guide the assembly of nanomaterials, or modulate the properties of biological systems. This paper describes a versatile technique that uses fine, electrified liquid jets formed by electrohydrodynamics at micro- and nanoscale nozzles to print complex patterns of both positive and negative charges, with resolution that can extend into the submicrometer and nanometer regime. The reported results establish the basic aspects of this process and demonstrate the capabilities through printed patterns with diverse geometries and charge configurations in a variety of liquid inks, including suspensions of nanoparticles and nanowires. The use of printed charge to control the properties of silicon nanomembrane transistors provides an application example.

42 ENGINEERING↗

New beam line for time-of-flight medium energy ion scattering with large area position sensitive detector

A new beam line for medium energy ion mass scattering (MEIS) has been designed and set up at the Angstroem laboratory, Uppsala University, Sweden. This MEIS system is based on a time-of-flight (ToF) concept and the electronics for beam chopping relies on a 4 MHz function generator. Repetition rates can be varied between 1 MHz and 63 kHz and pulse widths below 1 ns are typically obtained by including beam bunching. A 6-axis goniometer is used at the target station. Scattering angle and energy of backscattered ions are extracted from a time-resolved and position-sensitive detector. Examples of the performance are given for three kinds of probing ions, {sup 1}H{sup +}, {sup 4}He{sup +}, and {sup 11}B{sup +}. Depth resolution is in the nanometer range and 1 and 2 nm thick Pt layers can easily be resolved. Mass resolution between nearby isotopes can be obtained as illustrated by Ga isotopes in GaAs. Taking advantage of the large size detector, a direct imaging (blocking pattern) of crystal channels are shown for hexagonal, 4H-SiC. The ToF-MEIS system described in this paper is intended for use in semiconductor and thin film areas. For example, depth profiling in the sub nanometer range for device development of contacts and dielectric interfaces. In addition to applied projects, fundamental studies of stopping cross sections in this medium energy range will also be conducted.

43 PARTICLE ACCELERATORS↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend) This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 mu m spot of ~;;5x109 photons/ s (0.1percent bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored bytwo pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 um are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (~;;0.2 mu m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10-5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (~;;150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

47 OTHER INSTRUMENTATION↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nontrivial role of the resolution function in the formation of double-crystal X-ray rocking curves

A theoretical analysis of the shape of the resolution function of an X-ray diffractometer in the double-crystal nondispersive scheme for measuring rocking curves has been performed. It is shown that this function, along with the strong narrow central line (corresponding to the characteristic line to which the collimator crystal and slits in the experimental scheme are tuned) always contains an additional weak satellite, corresponding to the neighboring characteristic line. This feature manifests itself in experimental curves as an additional pseudopeak, whose intensity is comparable with the corresponding diffraction scattering intensity from a sample in the fundamental characteristic line, and whose shape and exact position are set by the resolution function in a specific experimental scheme. It is shown that the exact allowance for the angular and spectral distribution of incident radiation in the double-crystal scheme makes it possible to precisely determine the parameters of the structures studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Roller Cam Positioners

Roller Cam Positioners could support the LCLS undulator sections allowing micron sized alignment adjustment of each undulator in 5 degrees of freedom. The supports are kinematic with the number of degrees of freedom matched to the number of constraints. Ton loads are supported on simple ball bearings. Motion is intrinsically bounded. Positioning mechanisms are based on pure rolling motion with sub-micron hysteresis and micron resolution. This note describes a general purpose positioning mechanism suitable for undulator support.

43 PARTICLE ACCELERATORS↗

Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

43 PARTICLE ACCELERATORS↗

Large-surface-area diamond (111) crystal plates for applications in high-heat-load wavefront-preserving X-ray crystal optics

Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. In conclusion, the variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.

36 MATERIALS SCIENCE↗