Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I -- National Study

The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Thanks to advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India's RE targets and identify actions that may be favorable for integration. Our primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU's anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD $920 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment - from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India's 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Analysis of Inter-Area Oscillations in the US Eastern and Western Interconnections

This paper presents a comparative analysis of interarea oscillations in the US Eastern and Western Interconnections using frequency disturbance data collected from the advanced wide-area Frequency Monitoring Network (FNET/GridEye), enabling us to investigate and compare the oscillation characteristics of both regions. The study analyzes the statistical data from the two interconnections, including total oscillation events, average dominant frequencies, damping ratios, and maximum amplitudes. We also explore the impact of seasonal and daily variations on oscillation occurrences and the influence of different grid topologies and operational practices. The results provide insights into both interconnections' stability and control characteristics, offering valuable information for power system operators to enhance grid stability and oscillation suppression measures.

Fu, Hao [University of Tennessee, Knoxville (UTK)]↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗

Micro-grid for Future Planetary Surface Needs

Under the current Artemis Program, the National Aeronautics and Space Administration (NASA) will send its next set of astronauts (first woman and next man) to the Moon by 2024 and establish a sustainable presence on the lunar surface by 2028. The challenge of creating a sustained lunar surface presence is significantly different than previous efforts. Lunar surface operations will require access to continuous and highly reliable power to support mission needs, such as to support ISRU operations. Adding to this challenge, the lunar surface operations are not going to be established over a single effort, rather the system and operations will evolve and grow over time (years). The first initial loads that arrive on the lunar surface will be integrated to their own dedicated power sources. As the lunar surface operations grow, so will the demand for power and at some point these individual loads will require more power than can be generated with any single power device. This power demand drives the need for inter-connecting the loads and power devices to share power between them, resulting in a micro-grid. One of the advantages of developing a lunar surface micro-grid is that allows lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient, rather than negotiating between generation and consumption. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. Creating a lunar surface micro-grid has its advantages, however there are significant challenges associated with an evolvable micro-grid concept. The challenges include how to efficiently transmit large amounts of power (10kW+) long distances (1kW+), how to effectively integrate dissimilar power generation and energy storage devices to maximize power consumption and minimize downtime, and how to physically connect these devices together with a connector that can survive the lunar environment (dust, extreme cold temperatures) and is capable of both astronaut and robotic operation. The basic components of the micro-grid have to be designed to ensure the system is sustainable, modular, and reconfigurable. An interface to the micro-grid has to be designed that allows for additional technologies, some of which may not yet be fully designed, to easily integrate into the micro-grid concept. This presentation discusses these lunar challenges in some more depth and offers a path forward in designing an evolvable micro-grid to meet the needs of the lunar surface operations and proposes a Universal Micro-grid Interface Converter to connect these dissimilar power sources and mission loads to the micro-grid.

Jeffrey Csank↗

Artificial Intelligence for a Resilient and Flexible Power Grid

Recent widespread and extreme natural disasters as well as the drive towards clean sustainable energy sources necessitate a transformational operational and technological approaches to improve power grid resilience. Convergence of artificial intelligence (AI), distributed computing, and connectivity technologies enables these new approaches to deliver a sustainable electric grid. In particular, AI-based techniques can enable proactive decision-making by processing massive amounts of data to deliver intelligence at various levels of the system, edge devices to control room. In this chapter, we will explore the potential applications AI-based technology will unlock and challenges to address to achieve a sustainable, flexible power grid.

Omitaomu, Femi↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Locating the Source of Forced Oscillations in Transmission Power Grids

A forced oscillation event in power grids refers to a state where malfunctioning or abnormally operating equipment causes persisting periodic disturbances in the system. While power grids are designed to damp most perturbations during standard operations, some of them can excite normal modes of the system and cause significant energy transfers across the system, creating large oscillations thousands of miles away from the source. Localization of the source of such disturbances remains an outstanding challenge due to a limited knowledge of the system parameters outside of the zone of responsibility of system operators. Here, we propose a new method for locating the source of forced oscillations that addresses this challenge by performing a simultaneous dynamic model identification using a principled maximum likelihood approach. We illustrate the validity of the algorithm on a variety of examples where forcing leads to resonance conditions in the system dynamics. Our results establish that an accurate knowledge of system parameters is not required for a successful inference of the source and frequency of a forced oscillation. We anticipate that our method will find a broader application in general dynamical systems that can be well described by their linearized dynamics over short periods of time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Ride-Through Control Strategy for Single-Phase Virtual Synchronous Generator

This paper presents a fault ride-through control strategy for grid-tied virtual synchronous generator (VSG) under two main grid fault conditions, grid voltage sag fault and unintentional grid outage fault. Considering the overcurrent issue of VSG during the grid voltage sag fault, mechanism on overcurrent issue and the relationship among power angle, voltage amplitude, active power and reactive power are analyzed. Based on the analysis, a control strategy based on direct power angle and voltage amplitude control is proposed. Compared to the common control strategy based on additional inner current loop, the proposed VSG requires no add extra voltage or current sensors. For the grid outage fault, detailed analysis on the relationship among power angle, active power and frequency has been conducted, and it is found that the power angle is related to the output active power when the converter operates on grid-tied condition; under unintentional islanding conditions, the power angle is related to the voltage frequency. Based on the found, a detection method based on small frequency disturbance is proposed. Simulation studies on a prototype VSG system are presented to demonstrate the validity of the proposed control strategy.

Zeng, Rong↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application

This paper develops and compares two control schemes in the application control layer of a non-phase-locked loop (non-PLL) grid-forming (GFM) inverter to gain insight and understanding into how the two schemes affect the dynamic responses of GFM inverters and the transition operation of microgrids. The first scheme adopts power tracking based on an outer current loop in grid-connected mode and droop control in islanded mode, and the second uses droop control in both grid-connected and islanded modes. Analytical study is developed to compare the performance of these two strategies from various aspects, including fundamental differences, transition operation, power tracking, and P-Q capability with low point-of-common-coupling (PCC) voltages. Extensive simulation testing is carried out to validate the control performance of these two control strategies, and the simulation testing confirms the findings of the analytic study. Finally, the second strategy is recommended because of its superior control performance and ease of implementation. The analysis and results are useful in developing reliable control schemes for non-PLL GFM inverters because increasing numbers of inverters will work as non-PLL grid-forming sources in future grids because of their improved stability and reliability.

grid-forming↗

Onboard power line conditioning system for an electric or hybrid vehicle

A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Optimization for Grid Resilience. FY18 Final Technical Report

The optimal restoration problem lies at the foundation of the evaluation and improvement of resilience in power systems. In this report we present a scalable decomposition algorithm for solving this problem for realistic power systems. The algorithm has been developed in three major research threads, corresponding to the chapters in the present report. Chapter 1 studies mixed-integer programming (MIP) formulations for the requirement that each electrical island that appears after a recon guration must have at least one energized generator. We provide three alternative MIP formulations for this restriction, show their equivalence, and prove that two of them are stronger in terms of their linear programming relaxation than the formulation most commonly used in the power systems literature. Since the time to solve MIPs can vary signi cantly between equivalent formulations, we also present computational experiments on IEEE test systems for the Intentional Controlled Islanding (ICI) and the Black Start Allocation (BSA) problems. We observe that a polynomially separable, exponential in size, strong formulation yields the best performance for the BSA problem and exhibits a comparable performance to a linear in size, weak formulation for the ICI problem. Chapter 2 presents a methodology to generate mixed-integer linear approximations of the AC power ow equations governing lines, transformers (including tap regulators and phase shifters), shunt and series compensators, and consumption responsive to voltage. Our approximations are capable of capturing limitations for power grids under abnormal or uncommon operating conditions where common assumptions used in power ow relaxations may not hold. Particularly, the approximation captures overvoltages under almost no load, which is a major concern when energizing lines after a blackout. The method constructs piecewise linear approximations of the non-linear power ow equations by minimizing the squared approximation error over a subset of the feasible domain. We test the method using a realistic database for the Chilean system (1548 buses, 1114 lines, 564 transformers). The resulting approximations yield root mean square errors in the order of 0.05pu and are successfully applied to solve a transmission switching instance for the Chilean system. Chapter 3 presents our algorithm for optimal restoration. The algorithm works by partitioning the problem into a master problem and a slave problem. The master problem optimizes over energization sequences of generators, buses and branches, for the entire restoration horizon, while respecting the energization requiments studied in Chapter 1. The slave problem veri es that there exist power ow solutions supporting the energization sequences proposed by the master problem, adding cuts to the master if an infeasible sequence is detected.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Topology Estimation using Graphical Models in Multi-Phase Power Distribution Grids

Power distribution grids are structurally operated radially, such that energized lines form a collection of trees with a substation at the root of each tree. The operational topology may change from time to time, however tracking these changes, even though important for the distribution grid operation and control, is hindered by limited real-time monitoring. This work develops a learning framework to reconstruct the radial operational structure of the distribution grid from synchronized voltage measurements. To detect operational lines our learning algorithm uses conditional independence tests for continuous random variables that is applicable to a wide class of probability distributions and Gaussian injections in particular. Furthermore, our algorithm applies to the practical case of unbalanced three-phase power flow. The performance is validated on AC power flow simulations over three phase IEEE distribution grid test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report for Contract No. DE-EE0006332, "Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation"

This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Thrust Measurements of Marshall's Ion-ioN Thruster

Electronegative ion thrusters are a variation of traditional gridded ion thruster technology differentiated by the production and acceleration of both positive and negative ions. Benefits of electronegative ion thrusters include the elimination of lifetime-limiting cathodes from the thruster architecture and the ability to generate appreciable thrust from both charge species. While much progress has been made in the development of electronegative ion thruster technology, direct thrust measurements are required to unambiguously demonstrate the efficacy of the concept and support continued development. In the present work, direct thrust measurements of the thrust produced by the MINT (Marshall's Ion-ioN Thruster) are performed using an inverted-pendulum thrust stand in the High-Power Electric Propulsion Laboratory's Vacuum Test Facility-1 at the Georgia Institute of Technology with operating pressures ranging from 4.8 x 10(exp -5) and 5.7 x 10(exp -5) torr. Thrust is recorded while operating with a propellant volumetric mixture ratio of 5:1 argon to nitrogen with total volumetric flow rates of 6, 12, and 24 sccm (0.17, 0.34, and 0.68 mg/s). Plasma is generated using a helical antenna at 13.56 MHz and radio frequency (RF) power levels of 150 and 350 W. The acceleration grid assembly is operated using both sinusoidal and square waveform biases of +/-350 V at frequencies of 4, 10, 25, 125, and 225 kHz. Thrust is recorded for two separate thruster configurations: with and without the magnetic filter. No thrust is discernable during thruster operation without the magnetic filter for any volumetric flow rate, RF forward Power level, or acceleration grid biasing scheme. For the full thruster configuration, with the magnetic filter installed, a brief burst of thrust of approximately 3.75 mN +/- 3 mN of error is observed at the start of grid operation for a volumetric flow rate of 24 sccm at 350 W RF power using a sinusoidal waveform grid bias at 125 kHz and +/- 350 V. Similar bursts in thrust are observed using a square waveform grid bias at 10 kHz and +/- 350 V for volumetric flow rates of 6, 10, and 12 sccm at 150, 350, and 350 W respectively. The only operating condition that exhibits repeated thrust spikes throughout thruster operation is the 24 sccm condition with a 5:1 mixture ratio at 150 W RF power using the 10 kHz square waveform acceleration grid bias. Thrust spikes for this condition measure 3 mN with an error of +/- 2.5 mN. There are no operating conditions tested that show continuous thrust production.

Caruso, Natalie R. S.↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

Situational awareness-enhancing community-level load mapping with opportunistic machine learning

Motivated by present and forthcoming challenges in the adoption and integration of distributed renewable energy, we develop a machine learning (ML) approach that builds short-fuse mappings connecting the occasionally-unobservable true load in one target community with information-rich signals collected from relatively more instrumented reference communities. Our setting is inspired by and tailored to target communities with significant unobservable behind-the-meter solar generation, where true load (a relatively well-behaved quantity of interest to grid operators) is hard to discern during daytime due to insufficient instrumentation and/or privacy reasons, but that can be related to reference communities with low unobservable distributed variable generation or with sufficient instrumentation. The developed mapping, herein realized with Support Vector Machine regression, is built using nighttime data from all communities, when their distributed generation is low or zero. Our ML algorithm opportunistically learns to correlate signals of interest and then is operationally used the next day to shed light into target community load evolution. The mapping is subsequently rebuilt, rolling its short-fuse scope perpetually forward in time. Here, we demonstrate the efficacy of our approach on nine synthetically generated topologies and associated timeseries stemming from real-world data, on which we observe cumulative error performance that yields lower than 10% and 15% daily-averaged mean absolute percentage errors in target community load estimation on more than about 75% and 90% of days, respectively, in multiple yearly evaluations that shed light on long-term performance also under seasonal and one-off effects. The proposed ML-powered methodology can offer grid operators much-improved visibility into a previously obscure space and can also serve as an additional source of information in broader, multi-modal solar disaggregation solutions.

14 SOLAR ENERGY↗