Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Comparison of predicted and observed solar radiation in an urban area

Measurements of the downward solar radiant flux in the St. Louis area are compared with predictions from an approximate solution to the radiative transfer equation. The atmospheric aerosols were assumed to have a power size distribution and the refractive indices suggested by Fischer (1973) for an urban area. On a relatively clean day, the predictions compared well with observations. On a hazy day, the comparison was poor with the a priori choice of aerosol properties. The particles on the hazy day apparently had more submicron particles than those found in the assumed size distribution, and the particles were considerably less absorbing than those observed by Fischer. These changes could represent the effects of relative humidity and different air mass characteristics.

Bergstrom, R. W.↗

Data simulation studies for field programs, satellite system tests, and regional weather prediction

In the present paper, the status of the Drexel/NCAR regional numerical weather forecast system is summarized to show the extent of our experience and our immediate requirements for data within the United States on scales smaller than rawinsonde spacing (approximately 300 km). Preliminary experiments are described, and data assimilation problems are examined. It is shown that data requirements, assimilation methods, and forecast sensitivity differ for regional and large-scale models. Forecast verification statistics suggest that middle-troposphere temperature is well known but relative humidity is not. In some cases, regional forecasts require much better humidity data than available from rawinsondes. Numerics, lateral boundary conditions, model physics, and computing power are adequate for near real-time experimental regional prediction with horizontal mesh sizes down to 35 km. Subsynoptic data and assimilation are the primary challenges facing regional NWP.

Kreitzberg, C. W.↗

Space habitats

Differences between space industrialization and space colonization are outlined along with the physiological, psychological, and esthetic needs of the inhabitants of a space habitat. The detrimental effects of zero gravity on human physiology are reviewed, and the necessity of providing artificial gravity, an acceptable atmosphere, and comfortable relative humidity and temperature in a space habitat is discussed. Consideration is also given to social organization and governance, supply of food and water, and design criteria for space colonies.

Johnson, R. D.↗

Observations of the convective plume of a lake under cold-air advective conditions

Moderating effects of Lake Apopka, Florida, on downwind surface temperatures were evaluated under cold-air advective conditions. Point temperature measurements north and south of the lake and data obtained from a thermal scanner flown at 1.6 km indicate that surface temperatures directly downwind may be higher than surrounding surface temperatures by as much as 5 C under conditions of moderate winds (about 4 m/s). No substantial temperature effects were observed with surface wind speed less than 1 m/s. Fluxes of sensible and latent heat from Lake Apopka were calculated from measurements of lake temperature, net radiation, relative humidity, and air temperature above the lake. Bulk transfer coefficients and the Bowen ratio were calculated and found to be in agreement with reported data for nonadvective conditions.

Bill, R. G., Jr.↗

Moisture penetration in microcircuit packages

Results of study of hybrid microcircuit packages tested in temperature/humidity environments ranging from 25 C at 98 percent relative humidity (RH) to 85 C at 85 percent RH shows that package susceptibility to moisture is affected more by high temperature than humidity, and room temperature tests are inadequate for testing package seal integrity.

Licari, J. J.↗

Microwave radiometer measurement of water vapor path delay: Data reduction techniques

Data reduction techniques are developed to compensate for water vapor path delay, a limiting error source in geodetic measurements made with very long baseline interferometry and in radio ranging to spacecraft. It is shown that water vapor path delay is proportional to a linear combination of saturation-corrected sky brightness temperatures, measured on and off the water vapor line. The effects of emission from liquid water droplets in clouds as well as most of the oxygen emission are removed by the off-line channel. Sky brightness temperatures are saturation-corrected or 'linearized' using estimates of effective sky temperatures made from surface temperature. Tipping curves are used to remove instrumental error. Coefficients are found by two methods: from a regression analysis of measured brightness temperatures versus radiosonde measured delay, and from a regression analysis of theoretical brightness temperatures versus radiosonde measured delay. In each case the coefficients are adjusted for differing climatic conditions by measurements of surface temperature, pressure, and relative humidity. Regression solutions are constrained to remove liquid water contributions and to give the correct slope for radiometer versus radiosonde path delay.

Claflin, E. S.↗

Synthesis of improved moisture resistant polymers

The use of difluoromaleimide-capped prepolymers to provide improved moisture resistant polymers was investigated. Six different prepolymer formulations were prepared by two different methods. One method utilized the PMR approach to polyimides and the second method employed the normal condensation route to provide fully imidized prepolymers. Polymer specimens cured at 450 F exhibited adequate long-term stability in air at 400 F. Moisture absorption studies were conducted on one polymer formulation. Neat Polymer specimens exhibited weight gains of up to 2% (w/w) after exposure to 100% relative humidity at 344K (160 F) for 400 hours.

Orell, M. K.↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

The experiments conducted to determine the heat resistance of Bacillus megaterium ATCC 6458 at 90 and 100 C were completed. Estimates from replicate experiments at eight percent relative humidities (less than 0.001 to 100% RH) for each temperature were computed. A Bacillus cereus strain with high heat resistance was cultured and the resistance determined in phosphate buffer (D sub 121.1 = 2.16 min and z = 8.7 C). The profile of the dry heat resistance of B. megaterium is summarized and the most resistant condition to the three spores (Bacillus subtilis var. niger, ATCC 29669, and Bacillus stearothermophilus, strain 1518) is compared.

Reyes, A. L.↗

Notes on the meteorology of the intertropical convergence zone during the July 1977 experiment

The stratosphere and troposphere are large-scale open systems which exchange mass and trace constituents. If averaged over all longitudes, mass exchange can be expressed as products of the means and the mean of the product of the deviations from the mean. At high latitudes, the mass exchange is dominated by the deviations from the mean. At low latitudes, in the tropics, it is generally assumed that the mass exchange is caused by the mean motion. Figures are presented which depict: Northern Hemisphere mean motion; Convergence Zone motion; clouds and their motions; surface pressure variations; and meteorological parameters such as temperature, relative humidity, and ozone mixing ratios.

Danielson, E. F.↗

Electrochemically regenerable carbon dioxide absorber

Preliminary designs were generated for two electrochemically regenerable carbon dioxide absorber concepts. Initially, an electrochemically regenerable absorption bed concept was designed. This concept incorporated the required electrochemical regeneration components in the absorber design, permitting the absorbent to be regenerated within the absorption bed. This hardware was identified as the electrochemical absorber hardware. The second hardware concept separated the functional components of the regeneration and absorption process. This design approach minimized the extravehicular activity component volume by eliminating regeneration hardware components within the absorber. The electrochemical absorber hardware was extensively characterized for major operating parameters such as inlet carbon dioxide partial pressure, process air flow rate, operational pressure, inlet relative humidity, regeneration current density and absorption/regeneration cycle endurance testing.

Woods, R. R.↗

Feasibility study on the development of tough, moisture-resistant laminating resins

The potential of cyanate resins as replacement for epoxy resins in composites with graphite fiber reinforcement was investigated in an effort to provide improved moisture resistance and toughness in laminating systems at a projected cost, handleability, and processing requirements equivalent to 400 K (260 F) curing epoxies. Monomer synthesis, formulation, blending, resin preparation, catalysis studies, prepreg preparation, laminate fabrication, and testing are discussed. A graphite fiber reinforced laminate was developed with 95 percent retention of the original 363 K (180 F) flexural strength and 70 percent retention of the 363 K (180 F) short beam shear strength after 500 hour exposure to 95 + 7 relative humidity at 324 K (120 F).

Brand, R. A.↗

Atmospheric aerosol measurement problems

The present knowledge of the atmospheric aerosols is summarized briefly with respect to geographical distribution, time variations, optical properties, chemical nature, and natural and artificial sources. The measurement techniques for determining aerosol properties are summarized with the limitations and results from each. The problems resulting from variations in refractive index, shape, composition, volatile constituents, relative humidity and time from collection until measurement are described. Needed measurements on atmospheric aerosols are outlined with some of the latest methods for obtaining them, including the needs and goals of some world-wide programs.

Harris, F. S., Jr.↗

Procedure for developing experimental designs for accelerated tests for service-life prediction

Recommended design procedures to reduce the complete factorial design by retaining information on anticipated important interaction effects, and by generally giving up information on unconditional main effects are discussed. A hypothetical photovoltaic module used in the test design is presented. Judgments were made of the relative importance of various environmental stresses such as UV radiation, abrasion, chemical attack, temperature, mechanical stress, relative humidity and voltage. Consideration is given to a complete factorial design and its graphical representation, elimination of selected test conditions, examination and improvement of an engineering design, and parametric study. The resulting design consists of a mix of conditional main effects and conditional interactions and represents a compromise between engineering and statistical requirements.

Thomas, R. E.↗

The effect of paleoatmospheric ozone on surface temperature

Photochemical and radiative-convective calculations are performed to evaluate the influence of ozone in determining the surface temperature of the paleoatmosphere prior to the buildup of molecular oxygen to its present atmospheric level. Possible effects of atmospheric dynamics on the photochemistry and thermal structure of the paleoatmosphere are neglected, and the present atmospheric values are assumed for the tropospheric water-vapor relative-humidity distribution and lapse rate as well as for the fractional cloud amount and cloud reflectivity. It is found that the radiative effects (at IR and solar wavelengths) of ozone for a molecular oxygen level of one-tenth the present atmospheric level resulted in a globally averaged surface-temperature increase of about 4.5 K for the present solar constant. Implications of the results for paleoclimate are briefly considered.

Levine, J. S.↗

Thermodynamic and transport properties of air/water mixtures

Subroutine WETAIR calculates properties at nearly 1,500 K and 4,500 atmospheres. Necessary inputs are assigned values of combinations of density, pressure, temperature, and entropy. Interpolation of property tables obtains dry air and water (steam) properties, and simple mixing laws calculate properties of air/water mixture. WETAIR is used to test gas turbine engines and components operating in relatively humid air. Program is written in SFTRAN and FORTRAN.

Fessler, T. E.↗

Conditional instability of the first kind upside-down

It is shown that entrainment leads to the generation of turbulence kinetic energy in a stratocumulus layer when the virtual temperature jump at the cloud top is weaker than a critical value. The critical value increases as the relative humidity of the air above the cloud top decreases. This result is interpreted as a criterion for the instability of the layer cloud to penetrative downdrafts. The role of the instability in determining the subtropical and tropical distributions of boundary-layer cloudiness is assessed.

Randall, D. A.↗

The enhanced oxidation of SO2 by NO2 on carbon particulates

The oxidation of SO2 on carbon particles in dry air and in air at 65% relative humidity (RH) was found to be greatly enhanced by the presence of gaseous NO2. Exposures of 20-80ppm SO2 + 10ppm NO2 on 1-mg samples of commercial carbon black were found to produce both sorption and desorption coverages (weight retained after desorption into N2) of over one order of magnitude greater than for corresponding SO2 exposures. Significant agglomeration and wetting were observed to occur progressively during exposures at 65% RH, and samples, even after 150-h exposure, rarely reached steady-state weight gain. The wetting may have regenerated fresh reactive carbon surface. Sorptions conducted in nitrogen atmospheres, rather than in air, appeared to produce slightly higher sorptions and weight retentions for equivalent exposure concentrations and times, indicating that NO2 served as the oxidizer and that molecular oxygen, or some trace constitutents in air, may have weakly inhibited the oxidation by NO2. Wet chemical analysis of the desorbed phase indicated that sulfate, presumably H2SO4 accounted for over half of the retained weight. Measurements of pH from water-quenched samples indicated a highly acidic surface phase, and suggested the oxidation process could proceed in an acidic environment.

Cofer, W. R., III↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗