Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSMISSION LINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Systematic planning of moving target defence for maximising detection effectiveness against false data injection attacks in smart grid

Abstract Moving target defence (MTD) has been gaining traction to thwart false data injection attacks against state estimation (SE) in the power grid. MTD actively perturbs the reactance of transmission lines equipped with distributed flexible AC transmission system (D‐FACTS) devices to falsify the attacker's knowledge about the system configuration. However, the existing literature has not systematically studied what influences the detection effectiveness of MTD and how it can be improved based on the topology analysis. These problems are tackled here from the perspective of an MTD plan in which the D‐FACTS placement is determined. We first exploit the relation between the rank of the composite matrix and the detecting effectiveness. Then, we rigorously derive upper and lower bounds on the attack detecting probability of MTDs with a given rank of the composite matrix. Furthermore, we analyse existing planning methods and highlight the importance of bus coverage by D‐FACTS devices. To improve the detection effectiveness, we propose a novel graph theory–based planning algorithm to retain the maximum rank of the composite matrix while covering all necessary buses. Comparative results on multiple systems show the high detecting effectiveness of the proposed algorithm in both DC‐ and AC‐SE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Statistical Spread of Transmission Outages on a Fast Protection Time Scale Based on Utility Data

When there is a fault, the protection system automatically removes one or more transmission lines on a fast time scale of less than one minute. The outaged lines form a pattern in the transmission network. We extract these patterns from utility outage data, determine some key statistics of these patterns, and then show how to generate new patterns consistent with these statistics. The generated patterns provide a new and easily feasible way to model the overall effect of the protection system at the scale of a large transmission system. This new data-driven generative modeling of protection is expected to contribute to simulations of disturbances in large grids so that they can better quantify the risk of blackouts. Analysis of the pattern sizes suggests an index that describes how much outages spread in the transmission network at the fast timescale.

Transmission↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of the Attenuation Caused by Power Line Towers on an E1-HEMP Induced Excitation

In a transmission line, the coupling between a line and a tower above ground is evaluated when the excitation is an E1 high-altitude electromagnetic pulse (HEMP). The model focuses on capturing correctly the effect of the coupling on the peak of the HEMP induced current that propagates along the line. This assessment is necessary to accurately estimate the effect of the excitation on the systems and components of the power grid. This analysis is a step towards a quantitative evaluation of HEMP excitation on the power grid. The results obtained indicate that the effect can be significant, especially for lines heights of 20 meters or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast microwave switching power divider

Unit divides power from single input among any 12 of 120 output terminals and redistributes it in 6 microseconds. Microwave current from coaxial line excites disk feeding many radial strip transmission lines. Built for use in electronically-steered S-band antenna, device also divides and switches energy among filters and phase shifters.

Johnson, R. W.↗

Power line radiation in the magnetosphere

Harmonic radiation from electrical power transmission lines in the range of a few kHz leaks into the magnetosphere and stimulates a coherent wave instability, resulting in strong amplification of the input waves and the generation of free-running emissions. A description is given of some recent observational results that provide new information on the power line radiation (PLR) phenomenon. It is pointed out that PLR stimulates many subtle and complex wave-particle interactions in the magnetosphere that are similar to those simulated by controlled transmitter signals. These interactions undoubtedly affect both wave and particle environments in the magnetosphere. However, a quantitative assessment of their importance is not possible until further information becomes available.

Park, C. G.↗

Multilayer Microstrip Slot And Dipole Array Antenna

Multilayer antenna structure contains interleaved linear subarrays of microstrip dipole and slot radiating antenna elements to provide compact, dual-band antenna. Structure also contains associated microstrip transmission lines, plus high-power amplifiers for transmission and low-noise amplifiers for reception. Overall function is to transmit in horizontal polarization at frequency of 29.634 GHz and receive in vertical polarization at 19.914 GHz, in direction 44 degrees from broadside to antenna. Antenna structure is part of apparatus described in "Steerable K/Ka-band Antenna for Land-Mobile Satellite Applications," NPO-18772.

Tulintseff, Ann N.↗

Multimaterial Aerosol Jet Printed Magnetic Nanocomposites for Microwave Circuits

Here this article demonstrates the process and characterization of additively manufactured polymer-matrix magnetic nanocomposites. These nanocomposites are composed of nickel-zinc ferrite (Ni 0.5 Zn 0.5 Fe 2 O 4 ) nanoparticles in a polyimide matrix. These materials are printed using multimaterial aerosol jet printing where aerosols of nickel-zinc ferrite and polyimide inks are mixed in place to fabricate structures with nonunity relative permeability. To characterize these materials, we use energy-dispersive X-ray spectroscopy to estimate the content of ferrite in the composite, fitted simulation models, and ring resonator measurements to estimate the permeability. In fully aerosol jet printed 1-mm 2 inductors, we demonstrate an increase in inductance density of 40% in a 4.5-turn microstrip spiral inductor using this printed composite. These fully printed inductors demonstrate an inductance density of 4.2-nH/mm 2 . EDS analysis shows films with 18 wt.% Ni 0.5 Zn 0.5 Fe 2 O 4 . Finally, we show microstrip transmission lines on printed composite compared to the same on polyimide subjected to a dc magnetic bias, displaying a magnetic resonance behavior.

42 ENGINEERING↗

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Implementation of a Frenkel exciton-based controlled phase shifter

Frenkel excitons are of interest for ultrafast switching applications due to the femtosecond timescale at which coherent exciton transfer between chromophores takes place. The Frenkel Hamiltonian, which governs the dynamics of Frenkel excitons, belongs to a class of Hamiltonians that enable universal quantum computation. It is thus of interest to determine how a complete set of exciton-based gates for quantum computing could be constructed as aggregates of chromophores. Here, we demonstrate that a controlled phase shifter can be constructed as a pair of exciton transmission lines that employ two types of chromophores and that are cross coupled by a two-exciton interaction. This element facilitates the construction of controlled basis-change gates, thereby enabling the implementation of a complete set of exciton-based gates for universal quantum computation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Embedded ESD Protection Proof of Concept

The purpose of this project is to characterize and correlate Electrostatic Discharge (ESD) sensitivity levels of an Integrated Circuit (IC) package using Transmission Line Pulse (TLP) and Human Body Model (HBM) methods. This characterization will be used as a baseline ESD sensitivity level to demonstrate improvement to the ESD sensitivity of the IC package through the use of EPI-FLO(Trade Mark) Polymer Voltage Suppression (PVS) protection devices developed and manufactured by Electronic Polymers, Inc. (EPI).

Human Body Model (HBM) methods↗

An On-Chip Superconducting Kinetic Inductance Fourier Transform Spectrometer for Millimeter-Wave Astronomy

An on-chip FTS consists of two waveguides coupled to long superconducting transmission lines (STLs) (similar to 620 mm) using two coupling probes. The signal propagating on one of the STLs is phase-shifted with respect to the other line with a bias current that affects the nonlinear dependence of kinetic inductance, Lk(I)of the STL material. Here we describe the design and simulation of a superconducting on-chip FTS coupled to a dual polarization W-band (90-110 GHz) waveguide. These devices have applications in ground-based and space-based millimeter-wave spectral surveys.

Fourier transform spectrometer↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

This presentation starts with the details of IEEE 2800-2022 requirements of IBR for balanced and unbalanced faults. Then, it shows how to design a droop based GFM control to be IEEE 2800-2022 compliant. An performance evaluation is carried out to see if three OEM GFM inverters 2800-2022 compliant or not. And finally we show how IEEE 2800-2022 complaint and non-compliant GFM inverter will impact the transmission line protection elements, such as directional element and FID. Finally, recommendations are made if the GFM is not IEEE 2800-2022 compliant to disable the protection elements that rely on reliable and regulated negative sequence current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electron Dynamics Within a MITL Containing a Load

In this paper, we derive the vacuum electric fields within specific cylindrically symmetric magnetically insulated transmission lines (MITLs) in the limit of an infinite speed of light for an arbitrary time-dependent current. We focus our attention on two types of MITLs: the radial MITL and a spherically curved MITL. We then simulate the motion of charged particles, such as electrons, present in these MITLs due to the vacuum fields. In general, the motion of charged particles due to the vacuum fields is highly nonlinear since the fields are nonlinear functions of spatial coordinates and depend on an arbitrary time-dependent current drive. Using guiding center theory, however, one can describe the gross particle kinetics using a combination of $\textbf {E} \times \textbf {B}$ and $\nabla B$ drifts. In addition, we compare our approximate inner MITL field models and particle kinetics with those from a fully electromagnetic simulation code. We find that the agreement between the approximate model and the electromagnetic simulations is excellent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗