Search NASA⌕ Search

SEARCH · Search NASA

Results for “demonstration and field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Intrinsic nonlocality of spin- and polarization-resolved probabilities in strong-field quantum electrodynamics

Spin and polarization are central to precision tests of fundamental physics and for interpreting radiation from astrophysical sources and ultraintense laser-matter experiments. Here, focusing on the fundamental process of nonlinear Compton scattering, we demonstrate that a key assumption underlying current strong-field quantum electrodynamics models, i.e., that emission can be treated as an instantaneous random event sampled from a local differential rate, is inconsistent once emission angles, electron spin, and/or photon polarization are resolved. Namely, even in strictly constant and uniform fields , the resulting fully differential distribution is sign indefinite, yielding negative inferred probabilities. The physical reason is that the photon emission probability builds up over a finite length of the electron trajectory, the formation region, during which the electron direction changes by roughly the same small angle that defines the radiation cone. Therefore, we put forward a new method where we integrate over this formation region analytically to obtain a physically consistent electron spin and photon polarization model. We show that the implementation of our model is compatible with existing Monte Carlo and particle-in-cell workflows. Simulations of a GeV-class electron-laser collision accessible at current petawatt facilities and of emission in a pulsarlike magnetic field are shown to reveal spin and polarization patterns that differ even qualitatively from state-of-the-art local models. In particular, our new model predicts substantial angle-dependent circular photon polarization where the well-known collinear-emission approach yields none, and a pronounced helicity bias in the recoiling electrons absent from current predictions. These findings have direct implications for upcoming strong-field QED experiments and for interpreting polarized radiation from extreme astrophysical environments.

astrophysical electromagnetic fields↗

The 2010 ILSO-ISRU Field Test at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

For the advanced Moessbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform X-ray fluorescence analysis simultaneously to Moessbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The ISRU 2010 field campaign demonstrated that in-situ Moessbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

Current Sheets in the Corona and the Complexity of Slow Wind

The origin of the slow solar wind has long been one of the most important problems in solar/heliospheric physics. Two observational constraints make this problem especially challenging. First, the slow wind has the composition of the closed-field corona, unlike the fast wind that originates on open field lines. Second, the slow wind has substantial angular extent, of order 30 degrees, which is much larger than the widths observed for streamer stalks or the widths expected theoretically for a dynamic heliospheric current sheet. We propose that the slow wind originates from an intricate network of narrow (possibly singular) open-field corridors that emanate from the polar coronal hole regions. Using topological arguments, we show that these corridors must be ubiquitous in the solar corona. The total solar eclipse in August 2008, near the lowest point of cycle 23 affords an ideal opportunity to test this theory by using the ultra-high resolution Predictive Science's (PSI) eclipse model for the corona and wind. Analysis of the PSI eclipse model demonstrates that the extent and scales of the open-field corridors can account for both the angular width of the slow wind and its closed-field composition. We discuss the implications of our slow wind theory for the structure of the corona and heliosphere at solar minimum and describe further observational and theoretical tests.

Antiochos, Spiro↗

Advancing reliability assessments of photovoltaic modules and materials using combined-accelerated stress testing

Previously undiscovered failure modes in photovoltaic (PV) modules continue to emerge in field installations despite passing protocols for design qualification and quality assurance. Failure to detect these modes prior to widespread use could be attributed to the limitations of present-day standard accelerated stress tests (ASTs), which are primarily designed to identify known degradation or failure modes at the time of development by applying simultaneous or sequential stress factors (usually two at most). Here, we introduce an accelerated testing method known as the combined-accelerated stress test (C-AST), which simultaneously combines multiple stress factors of the natural environment. Simultaneous combination of multiple stress factors allows for improved identification of failure modes with better ability to detect modes not known a priori. A demonstration experiment was conducted that reproduced the field-observed cracking of polyamide- (PA-) and polyvinylidene fluoride (PVDF)–based backsheet films, a failure mode that was not detected by current design qualification and quality assurance testing requirements. In this work, a two-phase testing protocol was implemented. The first cycle (“Tropical”) is a predominantly high-humidity and high-temperature test designed to replicate harsh tropical climates. The second cycle (“Multi-season”) was designed to replicate drier and more temperate conditions found in continental or desert climates. Testing was conducted on 2 × 2-cell crystalline-silicon cell miniature modules constructed with both ultraviolet (UV)–transmitting and UV-blocking encapsulants. Cracking failures were observed within a cumulative 120 days of the Tropical condition for one of the PA-based backsheets and after 84 days of Tropical cycle followed by 42 days of the Multi-season cycle for the PVDF-based backsheet, which are both consistent with failures seen in fielded modules. In addition to backsheet cracking, degradation modes were observed including solder/interconnect fatigue, various light-induced degradation modes, backsheet delamination, discoloration, corrosion, and cell cracking. The ability to simultaneously apply multiple stress factors may allow many of the test sequences within the standardized design qualification procedure to be performed using a single test setup.

14 SOLAR ENERGY↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arc minute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arcminute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Wave Energy Power Take-off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bi-Directional High-Power DC Supply

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Wave Energy Power Take-Off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bidirectional High-Power DC Supply: Preprint

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Test of Superconducting Wires and Rutherford Cables With High Specific Heat

High-field accelerator magnets made of state-of-the-art Nb 3 Sn Rutherford cables demonstrate relatively long trainings due to sudden heat depositions originated by thermo-mechanical perturbations in the magnet coils. Coil sensitivity to these perturbations can be reduced by increasing the specific heat, Cp, of major coil components - strands, or whole cable, or epoxy. The R&D on all these three approaches is in progress. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using a thin composite Cu/Gd 2 O 3 tape. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. In this work, Cu/Gd 2 O 3 ribbons with ~30% of Gd 2 O 3 powder and two different thicknesses were produced by Hyper Tech Research, Inc. Wire and cable samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for the Minimum Quench Energy (MQE). At 80%Ic, the MQE gain average over the tested magnetic field range of the NbTi cable with high-Cp tape on both sides was ~1.3. The MQE gain average of the NbTi wire wrapped with the high-Cp ribbon was 3.1.

43 PARTICLE ACCELERATORS↗

Assessment of radar resolution requirements for soil moisture estimation from simulated satellite imagery

Radar simulations were performed at five-day intervals over a twenty-day period and used to estimate soil moisture from a generalized algorithm requiring only received power and the mean elevation of a test site near Lawrence, Kansas. The results demonstrate that the soil moisture of about 90% of the 20-m by 20-m pixel elements can be predicted with an accuracy of + or - 20% of field capacity within relatively flat agricultural portions of the test site. Radar resolutions of 93 m by 100 m with 23 looks or coarser gave the best results, largely because of the effects of signal fading. For the distribution of land cover categories, soils, and elevation in the test site, very coarse radar resolutions of 1 km by 1 km and 2.6 km by 3.1 km gave the best results for wet moisture conditions while a finer resolution of 93 m by 100 m was found to yield superior results for dry to moist soil conditions.

Ulaby, F. T.↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

SECARB 2020 Semi-Annual Field Review Reports - Anthropogenic Test

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.

01 COAL, LIGNITE, AND PEAT↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

A microwave systems approach to measuring root zone soil moisture

Computer microwave satellite simulation models were developed and the program was used to test the ability of a coarse resolution passive microwave sensor to measure soil moisture over large areas, and to evaluate the effect of heterogeneous ground covers with the resolution cell on the accuracy of the soil moisture estimate. The use of realistic scenes containing only 10% to 15% bare soil and significant vegetation made it possible to observe a 60% K decrease in brightness temperature from a 5% soil moisture to a 35% soil moisture at a 21 cm microwave wavelength, providing a 1.5 K to 2 K per percent soil moisture sensitivity to soil moisture. It was shown that resolution does not affect the basic ability to measure soil moisture with a microwave radiometer system. Experimental microwave and ground field data were acquired for developing and testing a root zone soil moisture prediction algorithm. The experimental measurements demonstrated that the depth of penetration at a 21 cm microwave wavelength is not greater than 5 cm.

Newton, R. W.↗

Copper atom based measurements of velocity and turbulence in arc jet flows

Laboratory and field measurements were combined with a modeling effort to explore the feasibility of using atomic copper laser-induced fluorescence to measure velocity, turbulence, and temperature in arcjet flows. Both CW and pulsed frequency-doubled dye lasers were used to demonstrate the ability to measure velocity with 10 percent accuracy at rates of 200,000 cm/s in a rarefied flow of Cu atoms seeded in He. The pulsed laser established a threshold energy for power-broadening of the absorption line at 3.5 x 10 to the -8th J/sq cm. Field measurements at the NASA/JSC 10-MW arcjet facility demonstrated the ability to perform these measurements under actual test conditions. The use of this technique to measure freestream temperatures in the flow was examined for the 0.08/cm linewidth laser used in the NASA/JSC effort. Finally, single-shot turbulence measurements at the USAF/AEDC 35-MW H2 arcjet facility were measured with 4 percent accuracy using the laser/absorption line-overlap technique.

Marinelli, William J.↗