Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

Stimulated resonant inelastic X-ray scattering in a solid

Abstract When materials are exposed to X-ray pulses with sufficiently high intensity, various nonlinear effects can occur. The most fundamental one consists of stimulated electronic decays after resonant absorption of X-rays. Such stimulated decays enhance the number of emitted photons and the emission direction is confined to that of the stimulating incident photons which clone themselves in the process. Here we report the observation of stimulated resonant elastic (REXS) and inelastic (RIXS) X-ray scattering near the cobalt L 3 edge in solid Co/Pd multilayer samples. We observe an enhancement of order 10 6 of the stimulated over the conventional spontaneous RIXS signal into the small acceptance angle of the RIXS spectrometer. We also find that in solids both stimulated REXS and RIXS spectra contain contributions from inelastic electron scattering processes, even for ultrashort 5 fs pulses. Our results reveal the potential and caveats of the development of stimulated RIXS in condensed matter.

36 MATERIALS SCIENCE↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Modeling of advanced accelerator concepts

Computer modeling is essential to research on Advanced Accelerator Concepts (AAC), as well as to their design and operation. This paper summarizes the current status and future needs of AAC systems and reports on several key aspects of (i) high-performance computing (including performance, portability, scalability, advanced algorithms, scalable I/Os and In-Situ analysis), (ii) the benefits of ecosystems with integrated workflows based on standardized input and output and with integrated frameworks developed as a community, and (iii) sustainability and reliability (including code robustness and usability).

47 OTHER INSTRUMENTATION↗

A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging

Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionalities from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in 130 nm technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous 1 MHz regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.

47 OTHER INSTRUMENTATION↗

ATLAS toward the High Luminosity era: challenges on electronic systems

To maximize the physics reach, the Large Hadron Collider (LHC) plans to increase its instantaneous luminosity to $7.5×10^{34} cm^{-2} s^{-1}$ and deliver $3 - 4 ab^{-1}$ of data at a center-of-mass energy of 14 TeV. To profit from this high-luminosity LHC operation with a pile-up up to 200 inelastic collisions per bunch crossing, performance of the ATLAS detector needs to be maintained and in many systems, improved. The upgraded detector will have an unprecedented output data rate of up to 200 TB/s. Real-time processing of this large data volume in a short time period is extremely challenging. New sets of both front-end and back-end electronics are required for all sub-detectors. The large number of detector channels, huge volumes of input and output data, short time available to process and transmit data, harsh radiation environment, and the need of low power consumption all impose great challenges on the designs of electronic systems.

43 PARTICLE ACCELERATORS↗

Optical damage considerations in the design of the matter in extreme condition upgrade (MEC-U) laser systems

The Matter in Extreme Conditions Upgrade (MEC-U) project is a major upgrade to the MEC instrument of the LINAC Coherent Light Source (LCLS) X-ray free electron laser (XFEL) user facility at SLAC National Accelerator Laboratory. Here, the envisioned MEC upgrade will significantly enhance the capabilities of the pump laser sources in current MEC experimental station, boosting the energy of the nanosecond shock driver from 100 J to the kJ level, and increasing the power and repetition rate of the short pulse laser from 25 TW at 5 Hz to 1 PW at 10 Hz rate. Building such high energy/power pump laser systems presents challenges to minimize and mitigate against laser-induced optical damage. Here, as part of the system design, we have identified the optics at high-risk to damage and we have designed the laser systems to mitigate against these damage risks to ensure sustained facility operation.

Coating↗

Domain Knowledge Guided Bayesian Optimization For Autonomous Alignment Of Complex Scientific Instruments

Bayesian Optimization (BO) is a powerful tool for optimizing complex non-linear systems. However, its performance degrades in high-dimensional problems with tightly coupled parameters and highly asymmetric objective landscapes, where rewards are sparse. In such needle-in-a-haystack scenarios, even advanced methods like trust-region BO (TurBO) often lead to unsatisfactory results. We propose a domain knowledge guided Bayesian Optimization approach, which leverages physical insight to fundamentally simplify the search problem by transforming coordinates to decouple input features and align the active subspaces with the primary search axes. We demonstrate this approach's efficacy on a challenging 12-dimensional, 6-crystal Split-and-Delay optical system, where conventional approaches, including standard BO, TuRBO and multi-objective BO, consistently led to unsatisfactory results. When combined with an reverse annealing exploration strategy, this approach reliably converges to the global optimum. The coordinate transformation itself is the key to this success, significantly accelerating the search by aligning input co-ordinate axes with the problem's active subspaces. As increasingly complex scientific instruments, from large telescopes to new spectrometers at X-ray Free Electron Lasers are deployed, the demand for robust high-dimensional optimization grows. Our results demonstrate a generalizable paradigm: leveraging physical insight to transform high-dimensional, coupled optimization problems into simpler representations can enable rapid and robust automated tuning for consistent high performance while still retaining current optimization algorithms.

FOS: Computer and information sciences↗

Characterization of high-frequency waves in the Martian magnetosphere

Context.Various high-frequency waves in the vicinity of upper-hybrid and Langmuir frequencies are commonly observed in different space plasma environments. Such waves and fluctuations have been reported in the magnetosphere of the Earth, a planet with an intrinsic strong magnetic field. Mars has no intrinsic magnetic field and, instead, it possesses a weak induced magnetosphere, which is highly dynamic due to direct exposure to the solar wind. In the present paper, we investigate the presence of high-frequency plasma waves in the Martian plasma environment by making use of the high-resolution electric field data from the Mars Atmosphere and Volatile Evolution missioN (MAVEN) spacecraft. Aims.This study aims to provide conclusive observational evidence of the occurrence of high-frequency plasma waves around the electron plasma frequency in the Martian magnetosphere. We observe two distinct wave modes with frequency below and above the electron plasma frequency. The characteristics of these high-frequency waves are quantified and presented here. We discuss the generation of possible wave modes by taking into account the ambient plasma parameters in the region of observation. Methods.We have made use of the medium frequency (100 Hz–32 kHz) burst mode-calibrated electric field data from the Langmuir Probe and Waves instrument on board NASA’s MAVEN mission. Due to the weak magnetic field strength, the electron gyro-frequency is much lower than the electron plasma frequency, which implies that the upper-hybrid and Langmuir waves have comparable frequencies. A total of 19 wave events with wave activities around electron plasma frequency were identified by examining high-resolution spectrograms of the electric field. Results.These waves were observed around 5 LT when MAVEN crossed the magnetopause boundary and entered the magnetosheath region. These waves are either a broadband- or narrowband-type with distinguishable features in the frequency domain. The narrowband-type waves have spectral peak above the electron plasma frequency. However, in the case of broadband-type waves, the spectral peak always occurred below the electron plasma frequency. The broadband waves consistently show a periodic modulation of 8–14 ms. Conclusions.The high-frequency narrowband-type waves observed above the electron plasma frequency are believed to be associated with upper-hybrid or Langmuir waves. However, the physical mechanism responsible for the generation of broadband-type waves and the associated 8–14 ms modulation remain unexplained and further investigation is required.

Astronomy & Astrophysics↗

Broadband coherent XUV light from e − / e + microbunching in an intense laser pulse

Attosecond pulses of coherent extreme ultraviolet (XUV) light are instrumental for investigating subatomic dynamics and can be produced using a free-electron laser (FEL). It has been suggested that an optical FEL, which employs a laser pulse in place of a conventional undulator, could enable a dramatically more compact implementation of such a light source. Yet, the high electron density and subsequent high emittance implied by an optical FEL makes this concept challenging to realize with an electron beam. There has been impressive progress in recent years producing collimated dense and relativistic beams of electrons and positrons in the laboratory. As we demonstrate here, the inherent stability of a quasi-neutral electron-positron beam mitigates Coulomb expansion, and renders it a promising alternative source of coherent light. Specifically, we show via computer simulations that broadband coherent light in the XUV domain, which takes the form of 8-as pulses at 92-as intervals, can be generated by microbunching of relativistic electrons and positrons in a laser pulse. This process occurs over a sub-millimeter length scale, enabling the development of light sources which are orders-of-magnitude more compact than existing sources, with potential applications in physics, chemistry, biology, and industry.

47 OTHER INSTRUMENTATION↗

The Q weak high performance LH 2 target

A high-power liquid hydrogen target was built for the Jefferson Lab Q weak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$ p scattering at an incident energy of 1.16 GeV, and a Q 2 = 0.025 GeV 2 . To achieve the luminosity of 1.7 x 10 39 cm -2 s -1 , a 34.5 cm- long target was used with a beam current of 180 μA. The ionization energy-loss deposited by the beam in the target was 2.1 kW. The target temperature was controlled to within ±0.02 K and the target noise (density fluctuations) near the experiment's beam helicity- reversal rate of 960 Hz was only 53 ppm. The 58 liquid liter target achieved a head of 11.4 m (7.6 kPa) and a mass flow of 1.2 ± 0.3 kg/s (corresponding to a volume flow of 17.4 ± 3.8 l/s) at the nominal 29 Hz rotation frequency of the recirculating centrifugal pump. We describe aspects of the design, operation, and performance of this target, the highest power LH2 target ever used in an electron scattering experiment to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-Ångström-resolution MicroED Using a Direct Detection Camera

The recent development of microcrystal electron diffraction (MicroED) in electron cryo-microscopy (cryo-EM) has addressed many of the challenges of X-ray crystallography [1], filling a long-standing need in organic chemistry for rapid and accurate high-resolution structural characterization [2]. Like X-ray crystallography, this is also a diffraction technique requiring crystalline specimens, but because high energy electrons have a more favorable ration of elastic to inelastic scattering [3], MicroED can acquire data using crystals that are orders of magnitude smaller than those needed for X-ray crystallography—even as small as 50 nm in length [4]. Additionally, the instrumentation required for MicroED is readily available, as many chemistry and biology labs already have access to cryo-capable transmission electron microscopes (TEM).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗