Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Constraining the physical conditions in the jets of γ-ray flaring blazars using centimeter-band polarimetry and radiative transfer simulations. I. Data and models for 0420–014, OJ 287, and 1156+295

To investigate parsec-scale jet flow conditions during GeV γ-ray flares detected by the Fermi Large Angle Telescope, we obtained centimeter-band total flux density and linear polarization monitoring observations from 2009.5 through 2012.5 with the 26 m Michigan radio telescope for a sample of core-dominated blazars. We use these data to constrain radiative transfer simulations incorporating propagating shocks oriented at an arbitrary angle to the flow direction in order to set limits on the jet flow and shock parameters during flares temporally associated with γ-ray flares in 0420–014, OJ 287, and 1156+295; these active galactic nuclei exhibited the expected signature of shocks in the linear polarization data. Both the number of shocks comprising an individual radio outburst (3 and 4) and the range of the compression ratios of the individual shocks (0.5-0.8) are similar in all three sources; the shocks are found to be forward-moving with respect to the flow. While simulations incorporating transverse shocks provide good fits for 0420–014 and 1156+295, oblique shocks are required for modeling the OJ 287 outburst, and an unusually low value of the low-energy cutoff of the radiating particles' energy distribution is also identified. Our derived viewing angles and shock speeds are consistent with independent Very Long Baseline Array results. While a random component dominates the jet magnetic field, as evidenced by the low fractional linear polarization, to reproduce the observed spectral character requires that a significant fraction of the magnetic field energy is in an ordered axial component. Both straight and low pitch angle helical field lines are viable scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SUPER-LINEAR SLOPE OF THE SPATIALLY RESOLVED STAR FORMATION LAW IN NGC 3521 AND NGC 5194 (M51a)

We have conducted interferometric observations with the Combined Array for Research in Millimeter Astronomy (CARMA) and an on-the-fly mapping with the 45 m telescope at Nobeyama Radio Observatory (NRO45) in the CO (J = 1-0) emission line of the nearby spiral galaxy NGC 3521. Using the new combined CARMA + NRO45 data of NGC 3521, together with similar data for NGC 5194 (M51a) and archival SINGS H{alpha}, 24 {mu}m THINGS H I, and Galaxy Evolution Explorer/Far-UV (FUV) data for these two galaxies, we investigate the empirical scaling law that connects the surface density of star formation rate (SFR) and cold gas (known as the Schmidt-Kennicutt law or S-K law) on a spatially resolved basis and find a super-linear slope for the S-K law when carefully subtracting the background emissions in the SFR image. We argue that plausibly deriving SFR maps of nearby galaxies requires the diffuse stellar and dust background emission to be subtracted carefully (especially in the mid-infrared and to a lesser extent in the FUV). Applying this approach, we perform a pixel-by-pixel analysis on both galaxies and quantitatively show that the controversial result whether the molecular S-K law (expressed as {Sigma}{sub SFR{proportional_to}{Sigma}H{sub 2}{sup {gamma}}{sub H{sup 2}}) is super-linear or basically linear is a result of removing or preserving the local background. In both galaxies, the power index of the molecular S-K law is super-linear ({gamma}{sub H{sub 2}}{approx}>1.5) at the highest available resolution ({approx}230 pc) and decreases monotonically for decreasing resolution. We also find in both galaxies that the scatter of the molecular S-K law ({sigma}{sub H{sub 2}}) monotonically increases as the resolution becomes higher, indicating a trend for which the S-K law breaks down below some scale. Both {gamma}{sub H{sub 2}} and {sigma}{sub H{sub 2}} are systematically larger in M51a than in NGC 3521, but when plotted against the de-projected scale ({delta}{sub dp}), both quantities become highly consistent for the two galaxies, tentatively suggesting that the sub-kpc molecular S-K law in spiral galaxies depends only on the scale being considered, without varying among spiral galaxies. A logarithmic function {gamma}{sub H{sub 2}}=-1.1 log [{delta}{sub dp}/kpc]+1.4 and a linear relation {sigma}{sub H{sub 2}}=-0.2 [{delta}{sub dp}/kpc]+0.7 are obtained through fitting to the M51a data, which describes both galaxies impressively well on sub-kpc scales. A larger sample of galaxies with better sensitivity, resolution, and broader field of view are required to test the general applicability of these relations.

79 ASTRONOMY AND ASTROPHYSICS↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear gyrokinetic simulations of toroidal Alfvén eigenmodes in the Mega-Amp Spherical Tokamak

Linear gyrokinetic (GK) simulations using the Gyrokinetic Toroidal Code (GTC) have been performed to investigate Toroidicity-driven Alfvén Eigenmodes (TAEs) driven by the neutral beam injection (NBI) induced fast ions in the Mega-Amp Spherical Tokamak (MAST) to identify the non-perturbative and kinetic effects of thermal plasma. A specific TAE in MAST discharge 26887, with an on-axis NBI power of approximately 1.5 MW and plasma current around 800 kA, exhibited frequency chirping, and the tangential soft x-ray camera array resolved the radial mode structure peaked near |q|=1.5. Various excitation methods were used in the GTC linear simulations, illustrating this code's capability to realistically represent the mechanisms and behaviors of fast ion-driven TAEs in spherical tokamaks. The radial structures from these GK simulations closely match measurements and calculations performed using the NOVA ideal MHD code, though with the frequencies approximately 10 kHz lower, likely due to various kinetic and non-perturbative effects. The simulations measured the damping rates due to continuum damping, radiative damping, and ion Landau damping, revealing that ion Landau damping has the most significant contribution to the total damping rate of the TAE. A comparison of growth rates of TAEs excited by fast ion Maxwellian and slowing-down distributions shows that the TAEs excited by a fast ion anisotropic pitch distribution (as part of the slowing-down distributions) are more unstable compared to those excited by a Maxwellian distribution with an equivalent fast ion beta. This shows that the use of fast ion anisotropy alters the number of fast ions to be in shear Alfvén resonance, and hence, it can greatly affect the stability of TAEs. These tests can be performed with the GTC but impossible with ideal MHD simulations, highlighting the necessity of kinetic simulations such as the GTC for a precise prediction of the TAE stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

No evidence for the blue-tilted power spectrum of relic gravitational waves

In this paper, we constrain the tilt of the power spectrum of relic gravitational waves by combining the data from BICEP2/Keck Array and Planck (BKP) and the Laser Interferometer Gravitational-Waves Observatory (LIGO). Supposing the linearly uniform priors for both the tensor-to-scalar ratio r and the tensor tilt n{sub t}, we find n{sub t}=0.66{sup +1.83}{sub −1.44} at the 68% confidence level from the data of BKP B-modes. By further adding the LIGO upper limit on the intensity of stochastic gravitational-wave background, the constraint becomes n{sub t}=−0.76{sup +1.37}{sub −0.52} at the 68% confidence level by assuming that the tensor amplitude has the similar order of the upper bounds from current CMB experiments. We find that there is no evidence for a blue-tilted power spectrum of relic gravitational waves and either sign of the index of tensor power spectrum is compatible with the current data.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of U 238 ( n , n ' γ ) cross section data and their impact on reaction models

A better knowledge of (n,xn) reaction cross sections is important for both reaction modeling and energy applications. This article focuses on inelastic scattering of neutrons off 238 U for which improvements are needed to better constrain evaluations and solve inconsistencies in nuclear power reactor calculations. A new precise measurement of (n,xnγ) reaction cross sections on 238 U has been performed at the GELINA (Geel Electron LINear Accelerator) neutron facility operated by EC-JRC-Geel (Belgium) with the GRAPhEME (GeRmanium array for Actinides PrEcise MEasurements) setup. The prompt γ-ray spectroscopy method coupled to time-of-flight measurements is used to extract (n,xnγ) cross section values which can be further combined to infer the total neutron inelastic scattering cross section. Cross section data for 18 γ transitions (five never measured before) are presented and compared to the data in the literature. Here, emphasis is especially given to the uncertainty determination to produce partial cross section data as accurate as possible. Due to intrinsic limitations of the experimental method, the use of additional nuclear structure information coupled with theoretical modeling is required to determine the total (n, n') cross section over the whole neutron energy range. We have investigated modeling aspects of the 238 U(n,n'γ) cross sections related to the description of compound nucleus and preequilibirum mechanisms as well as the discrete part of nuclear structure. Through comparison between experimental and calculated (n,n'γ) cross sections, we pinpoint inaccuracies in the description of specific reaction mechanisms and challenge recently implemented models. This helps improving the whole modeling of the (n, n') reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DPC Disposal Thermal Scoping Analysis

This is a progress report on thermal modeling for dual-purpose canister (DPCs) direct disposal that covers several available calculation methods and addresses creep and temperature-dependent properties in a salt repository. Three modeling approaches are demonstrated: A semi-analytical calculation method that uses linear solutions with superposition and imaging, to represent a central waste package in a larger array; A finite difference model of coupled thermal creep, implemented in FLAC2D; and An integrated finite difference thermal-hydrologic modeling approach for repositories in different generic host media, implemented in PFLOTRAN. These approaches are at different levels of maturity, and future work is expected to add refinements and establish the best applications for each.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Mapping Spiking Neural Networks to Heterogeneous Crossbar Architectures using Integer Linear Programming

Advances in novel hardware devices and architectures allow Spiking Neural Network (SNN) evaluation using ultra-low power, mixed-signal, memristor crossbar arrays. As individual network sizes quickly scale beyond the dimensional capabilities of single crossbars, networks must be mapped onto multiple crossbars. Crossbar sizes within modern Memristor Crossbar Architectures (MCAs) are determined predominately not by device technology but by network topology; more, smaller crossbars consume less area thanks to the high structural sparsity found in larger, brain-inspired SNNs. Motivated by continuing increases in SNN sparsity due to improvements in training methods, we propose utilizing heterogeneous crossbar sizes to further reduce area consumption. This approach was previously unachievable as prior compiler studies only explored solutions targeting homogeneous MCAs. Our work improves on the state-of-the-art by providing Integer Linear Programming (ILP) formulations supporting arbitrarily heterogeneous architectures. By modeling axonal interactions between neurons, our methods produce better mappings while removing inhibitive a priori knowledge requirements. We first show a 16.7-27.6% reduction in area consumption for square-crossbar homogeneous architectures. Then, we demonstrate 66.9-72.7% further reduction when using a reasonable configuration of heterogeneous crossbar dimensions. Next, we present a new optimization formulation capable of minimizing the number of inter-crossbar routes. When applied to solutions already near-optimal in area, an 11.9-26.4% routing reduction is observed without impacting area consumption. Finally, we present a profile-guided optimization capable of minimizing the number of runtime spikes between crossbars. Compared to the best-area-then-route optimized solutions, we observe a further 0.5-14.8% inter-crossbar spike reduction while requiring 1–3 orders of magnitude less solver time.

Pohl, Devin [ORNL] (ORCID:0009000040149027)↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

LOW-FREQUENCY OBSERVATIONS OF LINEARLY POLARIZED STRUCTURES IN THE INTERSTELLAR MEDIUM NEAR THE SOUTH GALACTIC POLE

We present deep polarimetric observations at 154 MHz with the Murchison Widefield Array (MWA), covering 625 deg{sup 2} centered on α = 0{sup h}and δ = −27°. The sensitivity available in our deep observations allows an in-band, frequency-dependent analysis of polarized structure for the first time at long wavelengths. Our analysis suggests that the polarized structures are dominated by intrinsic emission but may also have a foreground Faraday screen component. At these wavelengths, the compactness of the MWA baseline distribution provides excellent snapshot sensitivity to large-scale structure. The observations are sensitive to diffuse polarized emission at ∼54′ resolution with a sensitivity of 5.9 mJy beam{sup −1} and compact polarized sources at ∼2.′4 resolution with a sensitivity of 2.3 mJy beam{sup −1} for a subset (400 deg{sup 2}) of this field. The sensitivity allows the effect of ionospheric Faraday rotation to be spatially and temporally measured directly from the diffuse polarized background. Our observations reveal large-scale structures (∼1°–8° in extent) in linear polarization clearly detectable in ∼2 minute snapshots, which would remain undetectable by interferometers with minimum baseline lengths of >110 m at 154 MHz. The brightness temperature of these structures is on average 4 K in polarized intensity, peaking at 11 K. Rotation measure synthesis reveals that the structures have Faraday depths ranging from −2 to 10 rad m{sup −2} with a large fraction peaking at approximately +1 rad m{sup −2}. We estimate a distance of 51 ± 20 pc to the polarized emission based on measurements of the in-field pulsar J2330–2005. We detect four extragalactic linearly polarized point sources within the field in our compact source survey. Based on the known polarized source population at 1.4 GHz and non-detections at 154 MHz, we estimate an upper limit on the depolarization ratio of 0.08 from 1.4 GHz to 154 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Speed Ionic Synaptic Memory Based on 2D Titanium Carbide MXene

Synaptic devices with linear high-speed switching can accelerate learning in artificial neural networks (ANNs) embodied in hardware. Conventional resistive memories however suffer from high write noise and asymmetric conductance tuning, preventing parallel programming of ANN arrays. Electrochemical random-access memories (ECRAMs), where resistive switching occurs by ion insertion into a redox-active channel, aim to address these challenges due to their linear switching and low noise. ECRAMs using 2D materials and metal oxides however suffer from slow ion kinetics, whereas organic ECRAMs enable high-speed operation but face challenges toward on-chip integration due to poor temperature stability of polymers. Here, ECRAMs using 2D titanium carbide (Ti 3 C 2 T x ) MXene that combine the high speed of organics and the integration compatibility of inorganic materials in a single high-performance device are demonstrated. These ECRAMs combine the speed, linearity, write noise, switching energy, and endurance metrics essential for parallel acceleration of ANNs, and importantly, they are stable after heat treatment needed for back-end-of-line integration with Si electronics. The high speed and performance of these ECRAMs introduces MXenes, a large family of 2D carbides and nitrides with more than 30 stoichiometric compositions synthesized to date, as promising candidates for devices operating at the nexus of electrochemistry and electronics.

2D materials↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗

Transferring orbital angular momentum to an electron beam reveals toroidal and chiral order

Orbital angular momentum (OAM) and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics. Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices. Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. Instead, we find that the presence of an electric toroidal moment in a ferrorotational phase transfers measurable torque and OAM to a localized electron beam in the ballistic limit. We record these torque transfers from a high-energy electron beam using a momentum-resolved detector. This approach provides a high-sensitivity method to detect polarization fields and their more complex order parameters and topologies. In addition to toroidal order, we also demonstrate high-precision measurements of vorticity and chirality for polar vortexlike phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Open Source Laser Polymer Welding System: Design and Characterization of Linear Low-Density Polyethylene Multilayer Welds

The use of lasers to weld polymer sheets provides a means of highly-adaptive and custom additive manufacturing for a wide array of industrial, medical, and end user/consumer applications. This paper provides an open source design for a laser polymer welding system, which can be fabricated with low-cost fused filament fabrication and off-the-shelf mechanical and electrical parts. The system is controlled with free and open source software and firmware. The operation of the machine is validated and the performance of the system is quantified for the mechanical properties (peak load) and weld width of linear low density polyethylene (LLDPE) lap welds manufactured with the system as a function of linear energy density. The results provide incident laser power and machine parameters that enable both dual (two layers) and multilayer (three layers while welding only two sheets) polymer welded systems. The application of these parameter sets provides users of the open source laser polymer welder with the fundamental requirements to produce mechanically stable LLDPE multi-layer welded products, such as heat exchangers.

Laureto, John↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗