Search NASA⌕ Search

SEARCH · Search NASA

Results for “maximum likelihood estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probing the PeV region in the astrophysical neutrino spectrum using 𝜈 𝜇 from the Southern sky

IceCube has observed a diffuse astrophysical neutrino flux over the energy region from a few TeV to a few PeV. At PeV energies, the spectral shape is not yet well measured due to the low statistics of the data. This analysis probes the gap between 1 and 10 PeV by using high-energy downgoing muon neutrinos. Here, to reject the large atmospheric muon background, two complementary techniques are combined. The first technique selects events with high stochasticity to reject atmospheric muon bundles whose stochastic energy losses are smoothed due to high muon multiplicity. The second technique vetoes atmospheric muons with the IceTop surface array. Using 9 yrs of data, we found two neutrino candidate events in the signal region, consistent with expectation from background, each with relatively high signal probabilities. A joint maximum likelihood estimation is performed using this sample and an independent 9.5-yr sample of tracks to measure the neutrino spectrum. A likelihood ratio test is done to compare the single power-law (SPL) vs SPL+cutoff hypothesis; the SPL+cutoff model is not significantly better than the SPL. High-energy astrophysical objects from four source catalogs are also checked around the direction of the two events. No significant coincidence was found.

Abbasi, R. [Loyola University Chicago] (ORCID:0000↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

Improved renormalization group computation of likelihood functions for cosmological data sets

Evaluation of likelihood functions for cosmological large scale structure data sets (including CMB, galaxy redshift surveys, etc.) naturally involves marginalization, i.e., integration, over an unknown underlying random signal field. Recently, I showed how a renormalization group method can be used to carry out this integration efficiently by first integrating out the smallest scale structure, i.e., localized structure on the scale of differences between nearby data cells, then combining adjacent cells in a coarse graining step, then repeating this process over and over until all scales have been integrated. Here I extend the formulation in several ways in order to reduce the prefactor on the method's linear scaling with data set size. The key improvement is showing how to integrate out the difference between specific adjacent cells before summing them in the coarse graining step, compared to the original formulation in which small-scale fluctuations were integrated more generally. I suggest some other improvements in details of the scheme, including showing how to perform the integration around a maximum likelihood estimate for the underlying random field. In the end, an accurate likelihood computation for a million-cell Gaussian test data set runs in two minutes on my laptop, with room for further optimization and straightforward parallelization.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibrating two jets at once

Jet-energy calibration is an important aspect of many measurements and searches at the LHC. Currently, these calibrations are performed on a per-jet basis, i.e., agnostic to the properties of other jets in the same event. In this work, we propose taking advantage of the correlations induced by momentum conservation between jets in order to improve their jet-energy calibration. By fitting the p T asymmetry of dijet events in simulation, while remaining agnostic to the p T spectra themselves, we are able to obtain correlation-improved maximum likelihood estimates. This approach is demonstrated with simulated jets from the CMS detector, yielding a 3%–5% relative improvement in the jet-energy resolution, corresponding to a quadrature improvement of approximately 35%. Published by the American Physical Society 2024

Gambhir, Rikab (ORCID:0000000251080448)↗

Beyond integration: modeling every pixel to obtain better structure factors from stills

Most crystallographic data processing methods use pixel integration. In serial femtosecond crystallography (SFX), the intricate interaction between the reciprocal lattice point and the Ewald sphere is integrated out by averaging symmetrically equivalent observations recorded across a large number (10 4 -10 6 ) of exposures. Although sufficient for generating biological insights, this approach converges slowly, and using it to accurately measure anomalous differences has proved difficult. This report presents a novel approach for increasing the accuracy of structure factors obtained from SFX data. A physical model describing all observed pixels is defined to a degree of complexity such that it can decouple the various contributions to the pixel intensities. Model dependencies include lattice orientation, unit-cell dimensions, mosaic structure, incident photon spectra and structure factor amplitudes. Maximum likelihood estimation is used to optimize all model parameters. The application of prior knowledge that structure factor amplitudes are positive quantities is included in the form of a reparameterization. The method is tested using a synthesized SFX dataset of ytterbium(III) lysozyme, where each X-ray laser pulse energy is centered at 9034 eV. This energy is 100 eV above the Yb 3+ L -III absorption edge, so the anomalous difference signal is stable at 10 electrons despite the inherent energy jitter of each femtosecond X-ray laser pulse. This work demonstrates that this approach allows the determination of anomalous structure factors with very high accuracy while requiring an order-of-magnitude fewer shots than conventional integration-based methods would require to achieve similar results.

59 BASIC BIOLOGICAL SCIENCES↗

C2QA - Bosonic Qiskit

The practical benefits of hybrid quantum information processing hardware that contains continuous-variable objects (bosonic modes such as mechanical or electromagnetic oscillators) in addition to traditional (discrete-variable) qubits have recently been demonstrated by experiments with bosonic codes that reach the break-even point for quantum error correction [1]–[5] and by efficient Gaussian boson sampling simulation of the Franck-Condon spectra of triatomic molecules [6] that is well beyond the capabilities of current qubit-only hardware. The goal of this Co-design Center for Quantum Advantage (C2QA) project is to develop an instruction set architecture (ISA) for hybrid qubit/bosonic mode systems that contains an inventory of the fundamental operations and measurements that are possible in such hardware. The corresponding abstract machine model (AMM) would also contain a description of the appropriate error models associated with the gates, measurements and time evolution of the hardware. This information has been implemented as an extension of IBM Qiskit. IBM Qiskit is an open-source software development toolkit (SDK) for simulating the quantum state of a quantum circuit and for running the same circuits on prototype hardware within the IBM Quantum Experience. We introduce the Bosonic Qiskit software to enable the simulation of hybrid qubit/bosonic systems using the existing Qiskit software development kit [7]. This implementation can be used for simulating new hybrid systems, verifying proposed physical systems, and modeling systems larger than can currently be constructed. We also cover tutorials and example use cases included within the software to study JaynesCummings models, bosonic Hubbard models, plotting Wigner functions and animations, and calculating maximum likelihood estimations using Wigner functions.

quantum, boson, Qiskit↗

Network Detection of Radiation Sources Using Localization-Based Approaches

Radiation source detection is a critical problem in homeland security-related applications. Deploying a network of detectors is expected to provide improved detection due to the combined, albeit dispersed, capture area of multiple detectors. Recently, localization-based detection algorithms provided performance gains beyond the simple “aggregated” area as a result of localization being enabled by the networked detectors. We introduce the following three localization-based detection approaches: 1) source-attractor radiation detection (SRD); 2) triangulation-based radiation source detection (TriRSD); and 3) the ratio of square distance-based radiation source detection (ROSD-RSD). We use canonical datasets from Domestic Nuclear Detection Office's intelligence radiation sensors systems tests to assess the performance of these methods. Extensive results demonstrate that SRD outperforms TriRSD and ROSD-RSD, and other existing detection algorithms based on the sequential probability ratio test and maximum likelihood estimation in terms of both false alarm and detection rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative Reconstruction of Coded Source Neutron Radiographs

Use of a coded source facilitates high-resolution neutron imaging through magnifications but requires that the radiographic data be deconvolved. A comparison of direct deconvolution with two different iterative algorithms has been performed. One iterative algorithm is based on a maximum likelihood estimation (MLE)-like framework and the second is based on a geometric model of the neutron beam within a least squares formulation of the inverse imaging problem. Simulated data for both uniform and Gaussian shaped source distributions was used for testing to understand the impact of non-uniformities present in neutron beam distributions on the reconstructed images. Results indicate that the model based reconstruction method will match resolution and improve on contrast over convolution methods in the presence of non-uniform sources. Additionally, the model based iterative algorithm provides direct calculation of quantitative transmission values while the convolution based methods must be normalized base on known values.

Santos-Villalobos, Hector J↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Probing Quantum Telecloning on Superconducting Quantum Processors

Quantum information cannot be perfectly cloned, but approximate copies of quantum information can be generated. Quantum telecloning combines approximate quantum cloning, more typically referred to as quantum cloning, and quantum teleportation. Quantum telecloning allows approximate copies of quantum information to be constructed by separate parties, using the classical results of a Bell measurement made on a prepared quantum telecloning state. Quantum telecloning can be implemented as a circuit on quantum computers using a classical coprocessor to compute classical feedforward instructions using if statements based on the results of a midcircuit Bell measurement in real time. We present universal symmetric optimal 1 → M telecloning circuits and experimentally demonstrate these quantum telecloning circuits for M = 2 up to M = 10, natively executed with real-time classical control systems on IBM Quantum superconducting processors, known as dynamic circuits. We perform the cloning procedure on many different message states across the Bloch sphere, on seven IBM Quantum processors, optionally using the error suppression technique X–X sequence digital dynamical decoupling. Two circuit optimizations are utilized: one that removes ancilla qubits for M = 2,3 , and one that reduces the total number of gates in the circuit but still uses ancilla qubits. Parallel single-qubit tomography with maximum likelihood estimation density matrix reconstruction is used in order to compute the mixed-state density matrices of the clone qubits, and clone quality is measured using quantum fidelity. These results present one of the largest and most comprehensive noisy intermediate-scale quantum computer experimental analyses on (single qubit) quantum telecloning to date. The clone fidelity sharply decreases to 0.5 for M > 5 , but for M = 2 , we are able to achieve a mean clone fidelity of up to 0.79 using dynamical decoupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust Solution Verification Experiments on Nonuniform Meshes

The activities of verification, validation, and uncertainty quantification (VVUQ) provide a comprehensive means to assess the credibility of computational models. Within VVUQ, solution verification assesses numerical errors and evaluates whether the simulation is sufficiently accurate for its intended applications. As computational modeling gains traction in the development of complex, high-consequence systems, the need for robust solution verification intensifies, particularly because experimental data for these systems are often limited. This work examines improvements in the robustness of Richardson extrapolation (RE), a method commonly used in solution verification to study the discretization error of computational models using a power law. Nonuniform mesh refinement is discussed alongside other pollutants that affect the robustness of the power law model. Maximum likelihood estimation (MLE) is proposed as a robust strategy to address the uncertainty generated by nonuniform mesh refinement. An exploratory computational fluid dynamics (CFD) study of a 2D planar Poiseuille flow is conducted to determine if nonuniform mesh noise can be modeled with this MLE approach for more robust RE.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET

Purpose: Side readout of scintillation light from crystal elements in positron emission tomography (PET) is an alternative to conventional end-readout configurations, with the benefit of being able to provide accurate depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. This paper explores different readout geometries of scintillation crystal elements with the goal of achieving a detector that simultaneously achieves excellent timing resolution, energy resolution, spatial resolution, and photon sensitivity. Methods: The performance of discrete LYSO scintillation elements of different lengths read out from the end/side with digital silicon photomultipliers (dSiPMs) has been assessed. Results: Compared to 3 × 3 × 20 mm{sup 3} LYSO crystals read out from their ends with a coincidence resolving time (CRT) of 162 ± 6 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8% ± 0.2% without requiring energy saturation correction. Using a maximum likelihood estimation method on individual dSiPM pixel response that corresponds to different 511 keV photon interaction positions, the DOI resolution of this 3 × 3 × 20 mm{sup 3} crystal side-readout configuration was computed to be 0.8 mm FWHM with negligible artifacts at the crystal ends. On the other hand, with smaller 3 × 3 × 5 mm{sup 3} LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra. Conclusions: The energy, timing, and DOI resolution information extracted from the side of long scintillation crystal elements coupled to dSiPM have been acquired for the first time. The authors conclude in this proof of concept study that such detector configuration has the potential to enable outstanding detector performance in terms of timing, energy, and DOI resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

SU-F-T-103: Analysis of Hepatitis B Virus Reactivation After Conformal Radiotherapy in Patients with Hepatocellular Carcinoma Using the Lyman NTCP Model

Purpose: The aim of this research was to investigate the feasibility of Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model in analyzing hepatitis B virus (HBV) reactivation in patients receiving conformal radiotherapy for patients with hepatocellular carcinoma (HCC). Methods: Between June 2009 and June 2012, 108 HBV-related HCC patients (90 were specifically selected and 18 patients were excluded) treated with conformal RT at three centers were enrolled in this retrospective study. They were all diagnosed as HCC by pathology or cytology. All 90 patients were followed up to September 2013 with a median follow-up time of 25.2 months. The parameters (TD50 (1), n, and m) of the modified LKB NTCP model were derived using maximum likelihood estimation. Bootstrap and leave-one-out were employed to test the generalizability of the results for use in a general population. Results: The incidences of complications in the study population were as follows: radiation-induced liver diseases (RILD) were 17.6%, HBV reactivation was 24.8%, and HBV reactivation-induced hepatitis was 22.7%, respectively. In multivariate analysis, the NTCP (p<0.001), and V20 were associated with HBV reactivation. TD50 (1), m and n were 42.9Gy (95% CI) (38.2–46.8), 0.14 (0.12–0.15) and 0.30 (0.2–0.33), respectively, for HBV reactivation. Bootstrap and leave-one-out results showed that the HBV parameter fits were extremely robust. Conclusion: A modified LKB NTCP model has been established to predict HBV reactivation for patients with HCC receiving conformal RT. The finding derives parameters set to predict potential endpoints of HBV reactivation.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-10: Tumor Metabolic Control Probability & Dose Response Mapping for Adaptive Dose Painting by Number

Purpose: Adaptive dose-painting-by-number (DPbN) requires a dose-response-mapping (DRM) obtained early in the treatment course. To obtain DRM, voxel-by-voxel tumor dose response needs to be quantified. Our recent study has demonstrated that voxel-by-voxel radio-sensitivity of patient tumor can be determined using tumor-metabolic-ratio measured early during the treatment using FDG-PET images. In this study, the measurements were utilized to construct tumor metabolic control probability (TMCP) and DRM for DPbN. Methods: FDG-PET/CT images of 18 HN cancer patients obtained pre- and weekly during the treatment were used. Spatial parametric images of tumor-metabolic-ratio (dSUV) were constructed following voxel-by-voxel deformable image registration. Each voxel value in dSUV was a function of baseline SUV and delivered dose. Utilizing all values of dSUV in the controlled tumor group at the last treatment week, a cut-off function between the baseline SUV and dSUV was formed, and applied in early treatment days on dSUV of all tumors to model the TMCP. At the treatment week k, TMCP was constructed with respect to the tumor voxel dSUV appeared at the week using the maximum likelihood estimation for all dose levels, and used for DRM construction. Results: TMCPs estimated in the week 2 & 3 have D{sub 50}=11.1∼47.6Gy; γ{sub 50}=0.55∼0.92 respectively with respect to dSUV=0.3∼1.2. The corresponding DRM between tumor voxel dSUV and the expected treatment dose has sigmoid shape. The expected treatment dose are 26∼40Gy (for 95% TMCP) for high sensitive tumor voxels with dSUV=0.3∼0.5; and 65∼110Gy for low sensitive tumor voxels with the dSUV>1.0 depending on the time of the estimation. Conclusion: TMCP can be constructed voxel-by-voxel in human tumor using multiple FDG-PET imaging obtained in early treatment days. TMCP provides a potential quantitative objective of tumor DRM for DPbN to plan the best dose, escalate or de-escalate, in tumor adaptively based on its own radio-sensitivity.

60 APPLIED LIFE SCIENCES↗

Blind Ptychographic Phase Retrieval via Convergent Alternating Direction Method of Multipliers

Ptychography has risen as a reference X-ray imaging technique: it achieves resolutions of one billionth of a meter, macroscopic field of view, or the capability to retrieve chemical or magnetic contrast, among other features. A ptychographic reconstruction is normally formulated as a blind phase retrieval problem, where both the image (sample) and the probe (illumination) have to be recovered from phaseless measured data. In this article we address a nonlinear least squares model for the blind ptychography problem with constraints on the image and the probe by maximum likelihood estimation of the Poisson noise model. We formulate a variant model that incorporates the information of phaseless measurements of the probe to eliminate possible artifacts. Next, we propose a generalized alternating direction method of multipliers designed for the proposed nonconvex models with convergence guarantee under mild conditions, where their subproblems can be solved by fast el-ementwise operations. Numerically, the proposed algorithm outperforms state-of-the-art algorithms in both speed and image quality.

47 OTHER INSTRUMENTATION↗