Search NASA⌕ Search

SEARCH · Search NASA

Results for “mean squared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

advanced gas reactors↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the use of air temperature and precipitation as surrogate predictors in soil respiration modelling

Soil respiration (R S ), the soil-to-atmosphere CO 2 flux that is a major component of the global carbon cycle, is strongly influenced by local soil temperature (T soil ) and water content (SWC). Regional to global-scale R S modelling thus requires this information at local scales, but few high-quality, wall-to-wall (global) T soil and SWC data exist. As a result, such modelling efforts commonly use air temperature (T air ) and monthly precipitation (P m ) as surrogate predictors, but their site-scale accuracy and potential bias are unknown. In this report we used monthly data from 880 sites across a wide variety of different environmental conditions (i.e., climate, ecosystem type, elevation, vegetation leaf habit and drainage conditions) to determine the suitability of T air as a surrogate for T soil , and data from 507 sites to examine the suitability of P m as a surrogate for SWC. Site-specific linear and second-order exponential non-linear models were compared using model evaluation metrics (i.e., slope, p-value of slope, root mean square error [RMSE], index of agreement and model efficiency). We found that T soil and T air are highly correlated and explain similar R S variability. In contrast, P m is not a good surrogate for SWC, even though P m explains a similar amount of R S variability to SWC. The wide variability in the site-specific relationships between R S and SWC means that no single relationship can be used for large-scale modelling. The results from this study support the use of T air in continental-to-global scale R S models, and highlight the urgent need for continental-to-global scale SWC datasets for the modelling and evaluation of future soil carbon dynamics under global climate change.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning–Adjusted WRF Forecasts to Support Wind Energy Needs in Black Start Operations

Abstract The push for increased capacity of renewable sources of electricity has led to the growth of wind-power generation, with a need for accurate forecasts of winds at hub height. Forecasts for these levels were uncommon until recently, and that, combined with the nocturnal collapse of the well-mixed boundary layer and daytime growth of the boundary layer through the levels important for energy generation, has contributed to errors in numerical modeling of wind generation resources. The present study explores several machine learning algorithms to both forecast and correct standard WRF Model forecasts of winds and temperature at hub height within wind turbine plants over several different time periods that are critical for the anticipation of potential blackouts and aiding in black start operations on the power grid. It was found that mean square error for day-2 wind forecasts from the WRF Model can be improved by over 90% with the use of a multioutput neural network, and that 60-min forecasts of WRF error, which can then be used to adjust forecasts, can be made with an LSTM with great accuracy. Nowcasting of temperature and wind speed over a 10-min period using an LSTM produced very low error and especially skillful forecasts of maximum and minimum values over the turbine plant area.

17 WIND ENERGY↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

Simultaneous Retrieval of Effective Refractive Index and Density from Size Distribution and Light Scattering Data: Weakly-Absorbing Aerosol

We propose here a novel approach for retrieving in parallel the effective density and real refractive index of weakly absorbing aerosol from optical and size distribution measurements. Here we define “weakly absorbing” as aerosol single-scattering albedos that exceed 0.95 at 0.5 um.The required optical measurements are the scattering coefficient and the hemispheric backscatter fraction, obtained in this work from an integrating nephelometer. The required size spectra come from a Scanning Mobility Particle Sizer and an Aerodynamic Particle Sizer. The performance of this approach is first evaluated using a sensitivity study with synthetically generated but measurement-related inputs. The sensitivity study reveals that the proposed approach is robust to random noise; additionally the uncertainties of the retrieval are almost linearly proportional to the measurement errors, and these uncertainties are smaller for the real refractive index than for the effective density. Next, actual measurements are used to evaluate our approach. These measurements include the optical, microphysical, and chemical properties of weakly absorbing aerosol which are representative of a variety of coastal summertime conditions observed during the Two-Column Aerosol Project (TCAP; http://campaign.arm.gov/tcap/). The evaluation includes calculating the root mean square error (RMSE) between the aerosol characteristics retrieved by our approach, and the same quantities calculated using the conventional volume mixing rule for chemical constituents. For dry conditions (defined in this work as relative humidity less than 55%) and sub-micron particles, a very good (RMSE~3%) and reasonable (RMSE~28%) agreement is obtained for the retrieved real refractive index (1.49±0.02) and effective density (1.68±0.21), respectively. Our approach permits discrimination between the retrieved aerosol characteristics of sub-micron and sub-10micron particles. The evaluation results also reveal that the retrieved density and refractive index tend to decrease with an increase of the relative humidity.

density↗

The Joint Assimilation of Remotely Sensed Leaf Area Index and Surface Soil Moisture into a Land Surface Model

This work tests the hypothesis that jointly assimilating satellite observations of leaf area index and surface soil moisture into a land surface model improves the estimation of land vegetation and water variables. An Ensemble Kalman Filter is used to test such hypothesis across the Contiguous United States during April 2015 – December 2018. The performance of the proposed methodology is assessed for several modeled vegetation and water variables (evapotranspiration, net ecosystem exchange, and soil moisture) in terms of random errors and anomaly correlation coefficients against a set of independent validation datasets (i.e., Global Land Evaporation Amsterdam Model, FLUXCOM, and International Soil Moisture Network). Results show that the assimilation of leaf area index mostly improves the estimation of evapotranspiration and net ecosystem exchange, whereas the assimilation of surface soil moisture alone improves surface soil moisture content, especially in the western US, in terms of both root mean squared error and anomaly correlation coefficient. The joint assimilation of vegetation and soil moisture information combines the results of individual vegetation and soil moisture assimilations and reduces errors (and increases correlations with the reference datasets) in evapotranspiration, net ecosystem exchange, and surface soil moisture simulated by the land surface model. However, because soil moisture satellite observations only provide information on the water content in the top 5 cm of the soil column, the impact of the proposed data assimilation technique on root zone soil moisture is limited. This work moves one step forward in the direction of improving our estimation and understanding of land surface interactions using a multi-variate data assimilation approach, which can be particularly useful in regions of the world where ground observations are sparse or missing altogether.

Data assimilation↗

Towards optimal sensor placement for inverse problems in spaces of measures

The objective of this work is to quantify the reconstruction error in sparse inverse problems with measures and stochastic noise, motivated by optimal sensor placement. To be useful in this context, the error quantities must be explicit in the sensor configuration and robust with respect to the source, yet relatively easy to compute in practice, compared to a direct evaluation of the error by a large number of samples. In particular, we consider the identification of a measure consisting of an unknown linear combination of point sources from a finite number of measurements contaminated by Gaussian noise. The statistical framework for recovery relies on two main ingredients: first, a convex but non-smooth variational Tikhonov point estimator over the space of Radon measures and, second, a suitable mean-squared error based on its Hellinger–Kantorovich distance to the ground truth. To quantify the error, we employ a non-degenerate source condition as well as careful linearization arguments to derive a computable upper bound. This leads to asymptotically sharp error estimates in expectation that are explicit in the sensor configuration. Thus they can be used to estimate the expected reconstruction error for a given sensor configuration and guide the placement of sensors in sparse inverse problems.

97 MATHEMATICS AND COMPUTING↗

SU-D-BRF-03: Improvement of TomoTherapy Megavoltage Topogram Image Quality for Automatic Registration During Patient Localization

Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the image intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.

60 APPLIED LIFE SCIENCES↗

Statistical Tool Size Study for Computer-Controlled Optical Surfacing

Over the past few decades, computer-controlled optical surfacing (CCOS) systems have become more deterministic. A target surface profile can be predictably achieved with a combination of tools of different sizes. However, deciding the optimal set of tool sizes that will achieve the target residual error in the shortest run time is difficult, and no general guidance has been proposed in the literature. In this paper, we present a computer-assisted study on choosing the proper tool size for a given surface error map. First, we propose that the characteristic frequency ratio (CFR) can be used as a general measure of the correction capability of a tool over a surface map. Second, the performance of different CFRs is quantitatively studied with a computer simulation by applying them to guide the tool size selection for polishing a large number of randomly generated surface maps with similar initial spatial frequencies and root mean square errors. Finally, we find that CFR = 0.75 achieves the most stable trade-off between the total run time and the number of iterations and thus can be used as a general criterion in tool size selection for CCOS processes. To the best of our knowledge, the CFR is the first criterion that ties tool size selection to overall efficiency.

36 MATERIALS SCIENCE↗

End-to-end quality measure for transmission of compressed imagery over a noisy coded channel

For the transmission of imagery at high data rates over large distances with limited power and system gain, it is usually necessary to compress the data before transmitting it over a noisy channel that uses channel coding to reduce the effect of noise introduced errors. Both compression and channel noise introduce distortion into the imagery. In order to design a communication link that provides adequate quality of received images, it is necessary first to define some suitable distortion measure that accounts for both these kinds of distortion and then to perform various tradeoffs to arrive at system parameter values that will provide a sufficiently low level of received image distortion. The overall mean square error is used as the distortion measure and a description of how to perform these tradeoffs are included.

Korwar, V. N.↗

Multilevel Monte Carlo Estimation of Unbiased Expectation via Sample Reuse and the Low Variance Estimation of Asymptotic Rates

A new variant of the multilevel Monte Carlo estimator [5, 3, 9, 12] is presented for the estimation of expectation statistics that utilizes sample reuse in specified levels, explicitly removes approximation error bias associated with numerically computed output quantities of interest that have an asymptotic limit behavior, and permits a low variance estimate of the asymptotic rate of convergence to that limit. In addition, it is shown that this new multilevel Monte Carlo variant can yield a computational cost savings. A review of Monte Carlo and multilevel Monte Carlo estimators is presented that includes analysis of expected value, expected mean squared error, and the calculation of optimized multilevel sample size parameters. The multilevel Monte Carlo estimator produces estimates of expectation for numerically approximated output quantities of interest that are biased by approximation error. When the quantity of interest can be modeled as the asymptotic limit of numerically approximated output quantities of interest, it is theoretically possible to remove this approximation error bias in the multilevel Monte Carlo estimator. In actual implementations, however, this procedure is unreliable due to statistical variability and inaccuracy in estimating the needed asymptotic limit. Analysis and numerical experiment show that the proposed variant of the multilevel Monte Carlo method greatly reduces (in some cases eliminates) the statistical variability in this limit estimation.

Barth, Timothy↗

Optimal binning of correlated measurements

Experimental measurements are commonly represented on a discrete grid, requiring a balance between granularity and statistical noise. Two strategies have traditionally been used to improve such representations: selecting an appropriate bin width to control discretization error and applying kernel-based smoothing to suppress fluctuations. Despite their shared goal, these approaches have largely developed independently, without a unified statistical description of how discretization and correlation jointly determine measurement precision. Here, we extend the discussion of optimal interval averaging to a correlation-aware setting by Gaussian process regression, which explicitly accounts for correlations among neighboring bins. Starting from first principles, we derive the mean-squared error of discretized measurements and obtain closed-form asymptotic expressions for the optimal bin width and correlation length. When recast in reduced variables, the theory reveals distinct universal scaling laws governing the error in the correlation-free and correlation-controlled regimes. Characterized by intrinsically smooth intensity profiles and counting-based statistics, neutron scattering measurements are well suited for demonstrating the enhanced error contraction enabled by inter-bin correlations. We show that such improvement is achievable over the experimentally accessible Q-range and across multiple instruments and material systems. These results show that explicitly accounting for correlations systematically reshapes the limits of precision in discretized, noise-limited measurements. More broadly, the framework provides a transferable statistical foundation for optimizing data representation, inference, and experimental design across the physical and data sciences.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Observer-Based Nonlinear Control Scheme to Reduce Oscillations and Zero Crossing in Skid-Steer Vehicles

Motion sickness is a common condition experienced by drivers of skid-steer vehicles, primarily caused by zero crossing and oscillations in undamped systems. This study proposes an observer-based nonlinear control scheme to reduce transient oscillations and zero-crossing phenomena in skid-steer vehicles, thereby potentially alleviating motion sickness. Reducing transient oscillations and zero crossing in the transient response may alleviate motion sickness. A nonlinear damping controller is designed to improve transient response by reducing oscillations and zero-crossing. To design the controller, a reduced-order kinematic model based on coordinate transformation is developed. This transformation not only converts the system modeling into a controllable form but also enhances control performance. Modeling error is addressed by considering the distance between the center of the vehicle and the sensor location. Despite these improvements, model uncertainties and external disturbances remain, which may degrade control performance. To ensure robustness and estimate such disturbances, a high-order sliding mode observer (HOSMO) is incorporated. The effectiveness of the proposed method is validated through MATLAB/Simulink and TruckMaker simulations. From the simulation results, it was shown that the proposed method reduced the mean squared error of the tracking error to within 10 % compared to the state feedback controller with the HOSMO.

Seo, Jiwon [Chung-Ang University, Seoul (Korea, Re↗

Hourly PM 2.5 Estimates across California from 2018 to 2023

This study presents a new data set of hourly PM 2.5 concentrations across California from 2018 to 2023 at a three-kilometer resolution. This data set was developed by assimilating observations from PurpleAir and the U.S. EPA Air Quality System monitors into wildfire smoke forecasts from the High-Resolution Rapid Refresh Smoke (HRRR-Smoke) model using the Gridpoint Statistical Interpolation (GSI) three-dimensional variational data assimilation framework. Archived forecasts of modeled wildfire smoke PM 2.5 from HRRR-Smoke create the background field for assimilation, which is then corrected using surface observations of total PM 2.5 . The resulting reanalysis from GSI provides an estimate of total PM 2.5 that minimizes error from both the observational and the model data. Validation results indicate strong performance, with monthly R 2 values ranging from 0.73 to 0.91 across the six-year data set, comparable to other PM 2.5 data sets. Case studies are presented for three major fire events, the 2018 Camp Fire, 2019 Kincade Fire, and 2020 Lightning Complex Fires to demonstrate the data set’s fidelity in resolving plume dynamics and local exposure patterns. Root-mean-squared error averaged over each month scales with average PM 2.5 concentrations, resulting in a low error under typical conditions but higher absolute errors during extreme smoke events. This is the first long-term, hourly PM 2.5 data set of its kind for California and enables the generation of subdaily exposure metrics, such as peak hourly concentrations, exceedance durations, and time-of-day exposure peaks. The novelty and strong validation of this data set make it a compelling resource for future studies on the impact and significance of subdaily PM 2.5 exposure.

PM2.5↗