Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Towards combination of charge and light readout at O(10) MeV energies in DUNE

The Deep Underground Neutrino Experiment (DUNE) is an experiment under construction that will employ 10-kt scale liquid-argon-TPC technology to do precision measurements of neutrino oscillations. Apart from the determination of CP violation in neutrino interactions, one of the main scientific goals of DUNE is the detection of neutrinos from a supernova burst. It is imperative to maximise the potential of the detector for extracting information for these rare events. The use of light signals to aid the calorimetry of neutrino interactions provides such potential. We will present current efforts to demonstrate the application of combined calorimetry in one of the DUNE prototype detectors at CERN. The ground-level placement of the detector allows collection of large samples of cosmic-ray muons stopping within its volume. Michel electrons from muon decay can be identified in both the ionization charge and scintillation light, serving as a proxy for supernova neutrino interactions at O(10) MeV energies. The method for demonstrating combined calorimetry and its associated challenges will be introduced. We will also summarise the current analysis status and future prospects.

Pěč, Viktor [Prague, Inst. Phys.] (ORCID:000000034↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Reconfigurable training and reservoir computing in an artificial spin-vortex ice via spin-wave fingerprinting

Strongly interacting artificial spin systems are moving beyond mimicking naturally occurring materials to emerge as versatile functional platforms, from reconfigurable magnonics to neuromorphic computing. Typically, artificial spin systems comprise nanomagnets with a single magnetization texture: collinear macrospins or chiral vortices. Here, by tuning nanoarray dimensions we have achieved macrospin–vortex bistability and demonstrated a four-state metamaterial spin system, the ‘artificial spin-vortex ice’ (ASVI). ASVI can host Ising-like macrospins with strong ice-like vertex interactions and weakly coupled vortices with low stray dipolar field. Vortices and macrospins exhibit starkly differing spin-wave spectra with analogue mode amplitude control and mode frequency shifts of Δf = 3.8 GHz. The enhanced bitextural microstate space gives rise to emergent physical memory phenomena, with ratchet-like vortex injection and history-dependent non-linear fading memory when driven through global magnetic field cycles. We employed spin-wave microstate fingerprinting for rapid, scalable readout of vortex and macrospin populations, and leveraged this for spin-wave reservoir computation. ASVI performs non-linear mapping transformations of diverse input and target signals in addition to chaotic time-series forecasting.

97 MATHEMATICS AND COMPUTING↗

Optimal coupling of Ho W 10 molecular magnets to superconducting circuits near spin clock transitions

A central goal in quantum technologies is to maximize GT 2 , where G stands for the coupling of a qubit to control and readout signals and T 2 is the qubit’s coherence time. Furthermore, this is challenging, as increasing G (e.g., by coupling the qubit more strongly to external stimuli) often leads to deleterious effects on T 2 . Here, we study the coupling of pure and magnetically diluted crystals of Ho W 10 magnetic clusters to microwave superconducting coplanar waveguides. Absorption lines give a broadband picture of the magnetic energy level scheme and, in particular, confirm the existence of level anticrossings at equidistant magnetic fields determined by the combination of crystal field and hyperfine interactions. Such “spin clock transitions” are known to shield the electronic spins against magnetic field fluctuations. The analysis of the microwave transmission shows that the spin-photon coupling also becomes maximum at these transitions. The results show that engineering spin-clock states of molecular systems offers a promising strategy to combine sizable spin-photon interactions with a sufficient isolation from unwanted magnetic noise sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

Sensor Co-design for $\textit{smartpixels}$

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in the first level of the trigger for a hadron collider. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p$_T$) based on the geometrical shape of the charge deposition (``cluster''). To design a viable detector for deployment at an experiment, the dependence of the NN as a function of the sensor geometry, external magnetic field, and irradiation must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. A smaller sensor pitch in the bending direction improves the p$_T$ discrimination, but a larger pitch can be partially compensated with detector depth. An external magnetic field parallel to the sensor plane induces Lorentz drift of the electron-hole pairs produced by the charged particle, broadening the cluster and improving the network performance. The absence of the external field diminishes the background rejection compared to the baseline by $\mathcal{O}$(10%). Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by $\sim$ 30 - 60%, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data.

Shekar, Danush [Illinois U., Chicago]↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Analog-to-digital converter based on voltage-controlled superconducting devices

The increasing demand for cryogenic electronics in superconducting and quantum computing systems calls for ultra-energy-efficient data conversion architectures that remain functional at deep cryogenic temperatures. Here, in this work, we present the first design of a voltage-controlled superconducting flash analog-to-digital converter (ADC) based on a voltage-controlled quantum-enhanced Josephson junction field-effect transistor (JJFET). Exploiting its strong gate tunability and transistor-like behavior, the JJFET offers a scalable alternative to conventional current-controlled superconducting devices while aligning naturally with CMOS-style design methodologies. Building on our previously developed Verilog-A compact model calibrated to experimental data, we design and simulate a three-bit JJFET-based flash ADC targeted for integration within cryogenic control and readout circuitry in quantum computing. The core comparator block is realized through careful bias current selection and augmented with a three-terminal nanocryotron to precisely define reference voltages. Cascaded JJFET comparators ensure robust voltage gain, cascadability, and logic-level restoration across stages. Simulation results demonstrate accurate quantization behavior with ultra-low power dissipation, underscoring the feasibility of voltage-driven superconducting mixed-signal circuits. This work establishes a critical step toward unifying superconducting logic and data conversion, paving the way for scalable cryogenic architectures in quantum–classical co-processors, low-power artificial intelligence accelerators, and next-generation energy-constrained computing platforms.

Analog-to-digital converter↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Entangled Photon Pair Source Demonstrator Using the Quantum Instrumentation Control Kit System

Here, we report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC-FPGA technology to drive the electro-optic intensity modulator that generate time-bin entangled photon pairs and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

47 OTHER INSTRUMENTATION↗

Studies of Cherenkov photon production in PbF 2 crystals using proton beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. Finally, we focus on using PbF 2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A feasible path for the use of ferromagnetic josephson junctions in quantum circuits: The ferro-transmon

We discuss the capabilities of ferromagnetic (F) Josephson junctions (JJs) in a variety of layouts and configurations. The main goal is to demonstrate the potential of these hybrid JJs to disclose new physics and the possibility to integrate them in superconducting classical and quantum electronics for various applications. The feasible path towards the use of ferromagnetic Josephson junctions in quantum circuits starts from experiments demonstrating macroscopic quantum tunneling in NbN/GdN/NbN junctions with ferro-insulator barriers and with triplet components of the supercurrent, supported by a self-consistent electrodynamic characterization as a function of the barrier thickness. This has inspired further studies on tunnel ferromagnetic junctions with a different layout and promoted the first generation of ferromagnetic Al-based JJs, specifically Al/AlO x /Al/Py/Al. This layout takes advantage of the capability to integrate the ferromagnetic layer in the junction without affecting the quality of the superconducting electrodes and of the tunnel barrier. The high quality of the devices paves the way for the possible implementation of Al tunnel-ferromagnetic JJs in superconducting quantum circuits. These achievements have promoted the notion of a novel type of qubit incorporating ferromagnetic JJs. This qubit is based on a transmon design featuring a tunnel JJ in parallel with a ferromagnetic JJ inside a SQUID loop capacitively coupled to a superconducting readout resonator. In conclusion, the effect of an external RF field on the magnetic switching processes of ferromagnetic JJs has been also investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Searches for CE ν NS and physics beyond the standard model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering ( CE ν NS ) of reactor antineutrinos off silicon nuclei using thick fully depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with subelectron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing, data quality, and event selection for CE ν NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021–2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits for the neutrino interaction rates, comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model improve the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation by CONNIE obtains the best limits on the DM-electron scattering cross section by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗