At least 379 records · Page 21

Validation of a fault-tolerant clock synchronization system

A validation method for the synchronization subsystem of a fault tolerant computer system is investigated. The method combines formal design verification with experimental testing. The design proof reduces the correctness of the clock synchronization system to the correctness of a set of axioms which are experimentally validated. Since the reliability requirements are often extreme, requiring the estimation of extremely large quantiles, an asymptotic approach to estimation in the tail of a distribution is employed.

Butler, R. W.↗

Methods of Controlling the Loop Heat Pipe Operating Temperature

The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

Ku, Jentung↗

Avoiding Selection Bias in Generating Examples of Plans in the Presence of Heuristic Error

It is generally understood that heuristic error hurts the performance of search algorithms, measured in terms of search effort. Hence there is an interest in understanding how to reduce heuristic error. One way to do this is to learn a heuristic from a set of examples of plans generated offline, e.g. bootstrapping methods. In this paper, we consider how some methods for generating examples of plans may skew the training set in the presence of heuristic errors. Initial theoretical results show that duplicate detection is one source of selection bias in the canonical A* algorithm. We introduce a duplicate selection scheme for A* that avoids selection bias in generating cost-optimal examples, without compromising memory efficiency, and develop ideas in the satisficing setting. We evaluate our approach on n x m grids with multiple cost-optimal solutions and synthetic heuristic error. Finally, we attempt to extend these ideas to the problem of generating extreme examples of plans.

Alison S Paredes↗

Intravenous Fluid Mixing in Normal Gravity, Partial Gravity, and Microgravity: Down-Selection of Mixing Methods

The missions envisioned under the Vision for Space Exploration will require development of new methods to handle crew medical care. Medications and intravenous (IV) fluids have been identified as one area needing development. Storing certain medications and solutions as powders or concentrates can both increase the shelf life and reduce the overall mass and volume of medical supplies. The powders or concentrates would then be mixed in an IV bag with Sterile Water for Injection produced in situ from the potable water supply. Fluid handling in microgravity is different than terrestrial settings, and requires special consideration in the design of equipment. This document describes the analyses and down-select activities used to identify the IV mixing method to be developed that is suitable for ISS and exploration missions. The chosen method is compatible with both normal gravity and microgravity, maintains sterility of the solution, and has low mass and power requirements. The method will undergo further development, including reduced gravity aircraft experiments and computations, in order to fully develop the mixing method and associated operational parameters.

Niederhaus, Charles E.↗

On computing the global time-optimal motions of robotic manipulators in the presence of obstacles

A method for computing the time-optimal motions of robotic manipulators is presented that considers the nonlinear manipulator dynamics, actuator constraints, joint limits, and obstacles. The optimization problem is reduced to a search for the time-optimal path in the n-dimensional position space. A small set of near-optimal paths is first efficiently selected from a grid, using a branch and bound search and a series of lower bound estimates on the traveling time along a given path. These paths are further optimized with a local path optimization to yield the global optimal solution. Obstacles are considered by eliminating the collision points from the tessellated space and by adding a penalty function to the motion time in the local optimization. The computational efficiency of the method stems from the reduced dimensionality of the searched spaced and from combining the grid search with a local optimization. The method is demonstrated in several examples for two- and six-degree-of-freedom manipulators with obstacles.

Shiller, Zvi↗

Innovations in optimization and control of accelerators using methods of differential geometry and genetic algorithms (Final Report)

Online tuning of particle accelerators is necessary in order to achieve optimal machine performance. However, it is also a major challenge due to the large parameter space which must be searched and the fact that many of the desir- able objectives compete with one another, and so will not reach their optimal values simultaneously. In order to mitigate these issues, we have explored using dimension-reduction techniques to reduce the size of the parameter space which must be searched and multi-objective genetic algorithms to obtain the sets of tuning parameters which provide pareto-optimal values for the objectives. These methods have enabled us to obtain improved values of the vertical emittance at the Cornell Electron Storage Ring (CESR), and to do so with greater control of orbit errors. Algorithmic tuning is a multidisciplinary endeavour, requiring expertise in beam dynamics, diagnostics, control systems and computer science, and thus a key practical problem is to formulate a common language in which experts with different specialties can communicate. We developed a solution to this problem in the form of a generic accelerator software interface that allows for rapid prototyping of optimization and control algorithms. Our interface is built on the Experimental Physics and Industrial Control Systems (EPICS) and makes possible testing control code in simulation before deployment on real accelerators, as well as deployment of third-party optimization code.

43 PARTICLE ACCELERATORS↗

Resource-Efficient Chemistry on Quantum Computers with the Variational Quantum Eigensolver and The Double Unitary Coupled-Cluster approach

Applications of quantum simulation algorithms to obtain electronic energies of molecules on noisy intermediate-scale quantum (NISQ) devices require careful consideration of resources describing the complex electron correlation effects. In modeling second-quantized problems, the biggest challenge confronted is that the number of qubits scales linearly with the size of molecular basis. This poses a significant limitation on the size of the basis sets and the number of correlated electrons included in quantum simulations of chemical processes. To address this issue and to enable more realistic simulations on NISQ computers, we employ the double unitary coupled-cluster (DUCC) method to effectively downfold correlation effects into the reduced-size orbital space, commonly referred to as the active space. Using downfolding techniques, we demonstrate that properly constructed effective Hamiltonians can capture the effect of the whole orbital space in small-size active spaces. Combining the downfolding pre-processing technique with the Variational Quantum Eigensolver, we solve for the ground-state energy of H2 and Li2 in the cc-pVTZ basis using the DUCC-reduced active spaces. We compare these results to full configuration-interaction and high-level coupled-cluster reference calculations.

quantum computing, variational quantum solver, cou↗

TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.

60 APPLIED LIFE SCIENCES↗

Methods of improving spatial resolution for IR spectroscopy in atmospheric-pressure plasma systems

High-temperature, atmospheric pressure plasma systems operated in molecular gases present complex diagnostic challenges. Infrared spectroscopy has been used to make measurements of the absorbance spectrum of complex molecular gas mixtures and thereby calculate the concentrations and species temperatures in these systems. For atmospheric-pressure systems, high spatial gradients arise and high spatial-resolution measurements are thus desirable. Some systems have achieved increased spatial resolution by reducing the beam diameter. However, this increase in spatial resolution comes at the expense of the optical throughput. Here we propose modifying a commercial Fourier Transform, Infrared spectrometer system with a set of simple optical elements. This design allows for scannable, high spatial resolution absorbance spectrum measurements of a complex molecular gas mix. We analyze the signal-to-noise ratio for this design and compare it with the diameter reduction method. For sufficiently low plasma radiation levels, this design improves the signal-to-noise ratio relative to reducing the beam diameter size while transmitting nearly all of the beam power. Furthermore, whether this design can achieve the desired sub-mm spatial resolution depends on the radiating area of the infrared light source in the spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear-electronic orbital reduced explicitly correlated Hartree-Fock approach: Restricted basis sets and open-shell systems

The nuclear electronic orbital (NEO) reduced explicitly correlated Hartree-Fock (RXCHF) approach couples select electronic orbitals to the nuclear orbital via Gaussian-type geminal functions. This approach is extended to enable the use of a restricted basis set for the explicitly correlated electronic orbitals and an open-shell treatment for the other electronic orbitals. The working equations are derived and the implementation is discussed for both extensions. The RXCHF method with a restricted basis set is applied to HCN and FHF{sup −} and is shown to agree quantitatively with results from RXCHF calculations with a full basis set. The number of many-particle integrals that must be calculated for these two molecules is reduced by over an order of magnitude with essentially no loss in accuracy, and the reduction factor will increase substantially for larger systems. Typically, the computational cost of RXCHF calculations with restricted basis sets will scale in terms of the number of basis functions centered on the quantum nucleus and the covalently bonded neighbor(s). In addition, the RXCHF method with an odd number of electrons that are not explicitly correlated to the nuclear orbital is implemented using a restricted open-shell formalism for these electrons. This method is applied to HCN{sup +}, and the nuclear densities are in qualitative agreement with grid-based calculations. Future work will focus on the significance of nonadiabatic effects in molecular systems and the further enhancement of the NEO-RXCHF approach to accurately describe such effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical state and internal variables estimation using a reduced-order physics-based model of a lithium-ion cell and an extended Kalman filter

This paper addresses the problem of estimating the present value of electrochemical internal variables in a lithium-ion cell in real time, using readily available measurements of cell voltage, current, and temperature. The variables that can be estimated include any desired set of reaction flux and solid and electrolyte potentials and concentrations at any set of one-dimensional spatial locations, in addition to more standard quantities such as state of charge. The method uses an extended Kalman filter along with a one-dimensional physics-based reduced-order model of cell dynamics. Simulations show excellent and robust predictions having dependable error bounds for most internal variables. (C) 2014 Elsevier B.V. All rights reserved.

Stetzel, KD↗

Remobilizing the Interfaces of Thermocapillary Driven Bubbles Retarded by the Adsorption of a Surfactant Impurity on the Bubble Surface

Thermocapillary migration is a method for moving bubbles in space in the absence of buoyancy. A temperature gradient is applied to the continuous phase in which a bubble is situated, and the applied gradient impressed on the bubble surface causes one pole of the drop to be cooler than the opposite pole. As the surface tension is a decreasing function of temperature, the cooler pole pulls at the warmer pole, creating a flow which propels the bubble in the direction of the warmer fluid. A major impediment to the practical use of thermocapillarity to direct the movement of bubbles in space is the fact that surfactant impurities which are unavoidably present in the continuous phase can significantly reduce the migration velocity. A surfactant impurity adsorbed onto the bubble interface is swept to the trailing end of the bubble. When bulk concentrations are low (which is the case with an impurity), diffusion of surfactant to the front end is slow relative to convection, and surfactant collects at the back end of the bubble. Collection at the back lowers the surface tension relative to the front end setting up a reverse tension gradient. For buoyancy driven bubble motions in the absence of a thermocapillarity, the tension gradient opposes the surface flow, and reduces the surface and terminal velocities (the interface becomes more solid-like). When thermocapillary forces are present, the reverse tension gradient set up by the surfactant accumulation reduces the temperature tension gradient, and decreases to near zero the thermocapillary velocity. The objective of our research is to develop a method for enhancing the thermocapillary migration of bubbles which have been retarded by the adsorption onto the bubble surface of a surfactant impurity, Our remobilization theory proposes to use surfactant molecules which kinetically rapidly exchange between the bulk and the surface and are at high bulk concentrations. Because the remobilizing surfactant is present at much higher concentrations than the impurity, it adsorbs to the bubble much faster than the impurity when the bubble is formed, and thereby prevents the impurity from adsorbing onto the surface. In addition the rapid kinetic exchange and high bulk concentration maintain a saturated surface with a uniform surface concentrations. This prevents retarding surface tension gradients and keeps the velocity high. In our first report last year, we detailed experimental results which verified the theory of remobilization in ground based experiments in which the steady velocity of rising bubbles was measured in a continuous phase consisting of a glycerol/water mixture containing a polyethylene glycol surfactant C12E6 (CH3(CH2)11(OCH2CH2)6OH). In our report this year, we detail our efforts to describe theoretically the remobilization observed. We construct a model in which a bubble rises steadily by buoyancy in a continuous (Newtonian) viscous fluid containing surfactant with a uniform far field bulk concentration. We account for the effects of inertia as well as viscosity in the flow in the continuous phase caused by the bubble motion (order one Reynolds number), and we assume that the bubble shape remains spherical (viscous and inertial forces are smaller than capillary forces, i e. small Weber and capillary numbers). The surfactant distribution is calculated by solving the mass transfer equations including convection and diffusion in the bulk, and finite kinetic exchange the bulk and the surface. Convective effects dominate diffusive mass transfer in the bulk of the liquid (high Peclet numbers) except in a thin boundary layer near the surface. A finite volume method is used to numerically solve the hydrodynamic and mass transfer equations on a staggered grid which accounts specifically for the thin boundary layer. We present the results of the nondimensional drag as a function of the bulk concentration of surfactant for different rates of kinetic exchange, from which we develop criteria for the concentration necessary to develop a prescribed degree of remobilization. The criteria compare favorably with the experimental results.

Palaparthi, Ravi↗

A method to improve accuracy and precision of water surface identification for photon depth dose measurements

The objective of this study is to present a method to reduce the setup error inherent in clinical depth dose measurements and, in doing so, to improve entrance dosimetry measurement reliability. Ionization chamber (IC) depth dose measurements are acquired with the depth scan extended into the air above the water surface. An inflection region is obtained in each resulting percent depth ionization (PDI) curve that can be matched against other measurements or to an inflection region obtained from an analogous Monte Carlo (MC) simulation. Measurements are made with various field sizes for the 6 and 18 MV photon beams, with and without a Pb foil in the beam, to determine the sensitivity of the dose inflection region to the beam conditions. The offset between reference and test data set inflection regions is quantified using two separate methods. When comparing sets of measured data, maxima in the second derivative of ionization are compared. When comparing measured data to MC simulation, the offset that minimizes the sum of squared differences between the reference and test curves in the ionization inflection region is found. These methods can be used to quantify the offset between an initial setup (test) position and the true surface (reference) position. The ionization inflection location is found to be insensitive to changes in field size, electron contamination, and beam energy. Data from a single reference condition should be sufficient to identify the surface location. The method of determining IC offsets is general and should be applicable to any IC and other radiation sources. The measurement method could reduce the time and effort required in the initial IC setup at a water surface as setup errors can be corrected offline. Given a reliable set of reference data to compare with, this method could increase the ability of quality assurance (QA) measurements to detect discrepancies in beam output as opposed to discrepancies in IC localization. Application of the measurement method standardizes the procedure for localizing cylindrical ICs at a water surface and thereby improves the reliability of measurements taken with these devices at all depths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sky Residual Correction

The near-infrared is populated by numerous emission lines radiated from the Earth’s atmosphere, and these emission lines are often several orders of magnitude brighter in intensity than the typical astrophysical science target. The subtraction of these emission lines, sky subtraction, can create large systematic errors in ground-based astronomical spectra effectively limiting the number of usable resolution elements. A more effective sky subtraction, and the reduction of the systematic errors due to the sky subtraction process, is a major hurdle which ground-based astronomy must overcome to increase the amount of usable spectrum, and to be able to observe fainter scientific targets. Large high-quality data sets such as the Sloan Digital Sky Survey (SDSS) in themselves present opportunities for a reduction of the systematic sky subtraction errors through self-calibration. The sky residual correction method of Wild and Hewett is one such self-calibration technique which uses principal component analysis to reduce the systematic sky residual errors present in SDSS spectra. We apply sky residual corrections to the SDSS, Baryon Oscillation Spectroscopic Survey, and Apache Point Observatory Galactic Evolution Experiment data sets to optimize the number of subtraction components, and to quantify the reduction of the systematic errors in the science spectra. Finally as a proof of concept we use the sky-residual-corrected SDSS luminous red galaxy spectra to search for gravitationally lensed emission line Galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Input Shaping to Reduce Solar Array Structural Vibrations

Structural vibrations induced by actuators can be minimized using input shaping. Input shaping is a feedforward method in which actuator commands are convolved with shaping functions to yield a shaped set of commands. These commands are designed to perform the maneuver while minimizing the residual structural vibration. In this report, input shaping is extended to stepper motor actuators. As a demonstration, an input-shaping technique based on pole-zero cancellation was used to modify the Solar Array Drive Assembly (SADA) actuator commands for the Lewis satellite. A series of impulses were calculated as the ideal SADA output for vibration control. These impulses were then discretized for use by the SADA stepper motor actuator and simulated actuator outputs were used to calculate the structural response. The effectiveness of input shaping is limited by the accuracy of the knowledge of the modal frequencies. Assuming perfect knowledge resulted in significant vibration reduction. Errors of 10% in the modal frequencies caused notably higher levels of vibration. Controller robustness was improved by incorporating additional zeros in the shaping function. The additional zeros did not require increased performance from the actuator. Despite the identification errors, the resulting feedforward controller reduced residual vibrations to the level of the exactly modeled input shaper and well below the baseline cases. These results could be easily applied to many other vibration-sensitive applications involving stepper motor actuators.

Doherty, Michael J.↗

Acceleration of GPU-based Krylov solvers via data transfer reduction

Krylov subspace iterative solvers are often the method of choice when solving large sparse linear systems. At the same time, hardware accelerators such as graphics processing units continue to offer significant floating point performance gains for matrix and vector computations through easy-to-use libraries of computational kernels. However, as these libraries are usually composed of a well optimized but limited set of linear algebra operations, applications that use them often fail to reduce certain data communications, and hence fail to leverage the full potential of the accelerator. In this study, we target the acceleration of Krylov subspace iterative methods for graphics processing units, and in particular the Biconjugate Gradient Stabilized solver that significant improvement can be achieved by reformulating the method to reduce data-communications through application-specific kernels instead of using the generic BLAS kernels, e.g. as provided by NVIDIA’s cuBLAS library, and by designing a graphics processing unit specific sparse matrix-vector product kernel that is able to more efficiently use the graphics processing unit’s computing power. Furthermore, we derive a model estimating the performance improvement, and use experimental data to validate the expected runtime savings. Finally, considering that the derived implementation achieves significantly higher performance, we assert that similar optimizations addressing algorithm structure, as well as sparse matrix-vector, are crucial for the subsequent development of high-performance graphics processing units accelerated Krylov subspace iterative methods.

97 MATHEMATICS AND COMPUTING↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic substructuring by the boundary flexibility vector method of component mode synthesis

Component mode synthesis (CMS) is a method of dynamic analysis, for structures having a large number of degrees of freedom (DOF). These structures often required lengthy computer CPU time and large computer memory resources, if solved directly by the finite-element method (FEM). In CMS, the structure is divided into independent components in which the DOF are defined by a set of generalized coordinates defined by displacement shapes. The number of the generalized coordinates are much less than the original number of physical DOF, in the component. The displacement shapes are used to transform the component property matrices and any applied external loads, to a reduced system of coordinates. Reduced system property matrices are assembled, and any type of dynamic analysis is carried out in the reduced coordinate system. Any obtained results are back transformed to the original component coordinate systems. In all conventional methods of CMS, the mode shapes used for components are dynamic mode shapes, supplemented by static deflected shapes. Historically, all the dynamic mode shapes used in conventional CMS are the natural modes (eigenvectors) of components. A new method of CMS, namely the boundary flexibility vector method of CMS, is presented. The method provides for the incorporation of a set of static Ritz vectors, referred to as boundary flexibility vectors, as a replacement and/or supplement to conventional eigenvectors, as displacement shapes for components. The generation of these vectors does not require the solution of a costly eigenvalue problem, as in the case of natural modes in conventional CMS, and hence a substantial saving in CPU time can be achieved. The boundary flexibility vectors are generated from flexibility (or stiffness) properties of components. The formulation presented is for both free and fixed-interface components, and for both the free and forced vibration problems. Free and forced vibration numerical examples are presented to verify the accuracy of the method and the saving in CPU time. Compared to conventional methods of CMS, the results indicate that by using the new method, more accurate results can be obtained with a substantial saving in CPU time.

Abdallah, Ayman Ahmed↗