Search NASA⌕ Search

SEARCH · Search NASA

Results for “signal separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Interplanetary plasma concentration measurements by use of dual frequencies from separated sites

In the interplanetary plasma studies considered, signals at two frequencies are sent simultaneously from a single site on the earth to a spacecraft, or vice versa. Changes in group and phase velocity are proportional to the number density of the plasma and inversely proportional to the square of the signal frequency. Plasma-induced radio timing changes can be measured through comparisons of the changes at widely different frequencies. Such a system has, however, certain weaknesses, which can be overcome by making use of an approach which uses separated sites for sources of the low and high frequencies. The practical advantages gained by site separation are balanced somewhat by several technical problems, but each problem can be solved. The main barrier appears to be a very exacting timekeeping requirement. These requirements can be satisfied with the aid of the cesium clock.

Croft, T. A.↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Quantifying Polaron Mole Fractions and Interpreting Spectral Changes in Molecularly Doped Conjugated Polymers

Molecular doping of conjugated polymers causes bleaching of the neutral absorbance and results in new polaron absorbance transitions in the mid and near infrared. In this report the concentration dependent changes in the spectra for a series of molecularly doped diketopyrrolopyrrole (DPP) co-polymers with a series of ultra-high electron affinity cyanotrimethylenecyclopropane-based dopants is analyzed. With these strong dopants the polaron mole fraction (Θ) reaches saturation. Analysis of the full spectrum enables separation of neutral and polaron signals and quantification of the polaron mole fraction using a simple noninteracting site model. The peak ratios for both neutral and polaron peaks change systematically with increasing polaron mole fraction for all measured polymers. Analysis of the spectral changes indicates that the polaron mole fraction can be quantified to within 5%. While the total change in the absorbance spectrum with increasing polaron mole fraction is linear, the lowest energy polaron peak (P1) grows nonlinearly, which indicates increased polarization/delocalization. Molecular doping of polymers that form either H- or J-aggregates shows systematically different spectral changes in the vibronic peak ratios of the neutral spectra and provides insights into the polymer configuration at undoped sites in the film.

36 MATERIALS SCIENCE↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal dimensionality selection for independent component analysis of transcriptomic data

Independent component analysis is an unsupervised machine learning algorithm that separates a set of mixed signals into a set of statistically independent source signals. Applied to high-quality gene expression datasets, independent component analysis effectively reveals both the source signals of the transcriptome as co-regulated gene sets, and the activity levels of the underlying regulators across diverse experimental conditions. Two major variables that affect the final gene sets are the diversity of the expression profiles contained in the underlying data, and the user-defined number of independent components, or dimensionality, to compute. Availability of high-quality transcriptomic datasets has grown exponentially as high-throughput technologies have advanced; however, optimal dimensionality selection remains an open question. We computed independent components across a range of dimensionalities for four gene expression datasets with varying dimensions (both in terms of number of genes and number of samples). We computed the correlation between independent components across different dimensionalities to understand how the overall structure evolves as the number of user-defined components increases. We then measured how well the resulting gene clusters reflected known regulatory mechanisms, and developed a set of metrics to assess the accuracy of the decomposition at a given dimension. We found that over-decomposition results in many independent components dominated by a single gene, whereas under-decomposition results in independent components that poorly capture the known regulatory structure. From these results, we developed a new method, called OptICA, for finding the optimal dimensionality that controls for both over- and under-decomposition. Specifically, OptICA selects the highest dimension that produces a low number of components that are dominated by a single gene. We show that OptICA outperforms two previously proposed methods for selecting the number of independent components across four transcriptomic databases of varying sizes. OptICA avoids both over-decomposition and under-decomposition of transcriptomic datasets resulting in the best representation of the organism’s underlying transcriptional regulatory network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging Afterglow in Scintillation-based x-ray detectors for spacetime-resolved computed tomography for accelerated acquisition and high-speed event capture

Afterglow in x-ray imaging for high-speed radiography is a constraint that limits imaging systems to low-light/fast decay screens which create poor data. Current approaches focus purely on using low-light yield screens with fast decay to avoid multiple exposure pileup due to afterglow. The goal of this work is to develop a statistical estimation approach to leverage afterglow to improve image quality thus allowing for higher quality imaging components to be used. This will allow for bright screens will slow decay to be used, and then a post-processing step applies the statistical estimation to separate each frame with superior signal compared to low-light/fast decay screens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flight test and evaluation of Omega navigation for general aviation

A seventy hour flight test program was performed to determine the suitability and accuracy of a low cost Omega navigation receiver in a general aviation aircraft. An analysis was made of signal availability in two widely separated geographic areas. Comparison is made of the results of these flights with other navigation systems. Conclusions drawn from the test experience indicate that developmental system improvement is necessary before a competent fail safe or fail soft area navigation system is offered to general aviation.

Hwoschinsky, P. V.↗

Evaluation of space shuttle main engine fluid dynamic frequency response characteristics

In order to determine the POGO stability characteristics of the space shuttle main engine liquid oxygen (LOX) system, the fluid dynamic frequency response functions between elements in the SSME LOX system was evaluated, both analytically and experimentally. For the experimental data evaluation, a software package was written for the Hewlett-Packard 5451C Fourier analyzer. The POGO analysis software is documented and consists of five separate segments. Each segment is stored on the 5451C disc as an individual program and performs its own unique function. Two separate data reduction methods, a signal calibration, coherence or pulser signal based frequency response function blanking, and automatic plotting features are included in the program. The 5451C allows variable parameter transfer from program to program. This feature is used to advantage and requires only minimal user interface during the data reduction process. Experimental results are included and compared with the analytical predictions in order to adjust the general model and arrive at a realistic simulation of the POGO characteristics.

Gardner, T. G.↗

E-beam generated holographic masks for optical vector-matrix multiplication

An optical vector matrix multiplication scheme that encodes the matrix elements as a holographic mask consisting of linear diffraction gratings is proposed. The binary, chrome on glass masks are fabricated by e-beam lithography. This approach results in a fairly simple optical system that promises both large numerical range and high accuracy. A partitioned computer generated hologram mask was fabricated and tested. This hologram was diagonally separated outputs, compact facets and symmetry about the axis. The resultant diffraction pattern at the output plane is shown. Since the grating fringes are written at 45 deg relative to the facet boundaries, the many on-axis sidelobes from each output are seen to be diagonally separated from the adjacent output signals.

Arnold, S. M.↗

Discovery of 69 ms periodic X-ray pulsations in A0538-66

The detection of X ray pulsations with a period of 69.2126 ms from A0538-66 was done from the Einstein Observatory. A point source was located by the High Resolution Imager and a proportional counter registered a flux of 40 counts/sec over background. A column spectral density of 2 x 10 to the 23/sq cm identified the object as A0538-66. A persistent periodicity of 0.0692126 sec was observed throughout the event. The outbursts were not detected on three other observations of A0538-66, and a best fit to a change of rotation velocity indicated that the period observed was from a binary star with a Doppler shifted signal. The two stars are separated by less than 39 solar radii, with the larger star having a 40 solar radius. Consideration is given to the possibility that the X rays are due to accretion on a neutron star and that the two stars at times share a common envelope.

Skinner, G. K.↗

Monolithic 20-GHz Transmitting Module

20-GHz monolithic microwave/millimeter-wave integrated circuit (MMIC) with amplification and phase-shift (time-delay) capabilities developed. Use of MMIC module technology promises to make feasible development of weight- and cost-effective phased-array antenna systems, identified as major factor in achieving minimum cost and efficient use of frequency and orbital resources of future generations of communication satellite systems. Use of MMIC transmitting modules provides for relatively simple method for phase-shift control of many separate radio-frequency (RF) signals required for phased-array antenna systems.

Kascak, T.↗

Investigation of the quantum efficiency of optical heterodyne detectors

The frequency response and quantum efficiency of optical photodetectors for heterodyne receivers is investigated. The measurements utilized two spectral lines from the output of two lasers as input to the photodetectors. These lines are easily measurable in power and frequency and hence serve as known inputs. By measuring the output current of the photodetector the quantum efficiency is determined as a function of frequency separation between the two input signals. An investigation of the theoretical basis and accuracy of this type of measurement relative to similar measurements utilizing risetime is undertaken. A theoretical study of the heterodyne process in photodetectors based on semiconductor physics is included so that higher bandwidth detectors may be designed. All measurements are made on commercially available detectors and manufacturers' specifications for normal photodetector operation are compared to the measured heterodyne characteristics.

Batchman, T. E.↗

Laser sounding of instantaneous and mean speed of wind using correlation method

The correlation methods for laser sounding of wind speed are based on mutual processing of lidar signals scattered from several spatially separated volumes at each altitude investigated. The time of atmospheric aerosol transport between the scattering volumes estimated by the position of maximum of the mutual correlation function is the measure of corresponding wind speed. In this case the distance between the scattering volumes (the measuring base), defining the time of aerosol movement through the measuring base also determines the lidar possibilities for measuring the instantaneous (during the time interval of several seconds) or the mean wind speed (some minutes). Based on the experimental investigations performed using two lidars, these possibilites are analyzed.

Zuev, V. E.↗

State-of-the-art satellite laser range modeling for geodetic and oceanographic applications

Significant improvements have been made in the modeling and accuracy of Satellite Laser Range (SLR) data since the launch of LAGEOS in 1976. Some of these include: improved models of the static geopotential, solid-Earth and ocean tides, more advanced atmospheric drag models, and the adoption of the J2000 reference system with improved nutation and precession. Site positioning using SLR systems currently yield approximately 2 cm static and 5 mm/y kinematic descriptions of the geocentric location of these sites. Incorporation of a large set of observations from advanced Satellite Laser Ranging (SLR) tracking systems have directly made major contributions to the gravitational fields and in advancing the state-of-the-art in precision orbit determination. SLR is the baseline tracking system for the altimeter bearing TOPEX/Poseidon and ERS-1 satellites and thus, will play an important role in providing the Conventional Terrestrial Reference Frame for instantaneously locating the geocentric position of the ocean surface over time, in providing an unchanging range standard for altimeter range calibration, and for improving the geoid models to separate gravitational from ocean circulation signals seen in the sea surface. Nevertheless, despite the unprecedented improvements in the accuracy of the models used to support orbit reduction of laser observations, there still remain systematic unmodeled effects which limit the full exploitation of modern SLR data.

Klosko, Steve M.↗