Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H↗

Impact Testing Theories and Techniques Employed at the TA-III Mechanical Shock Complex

We present theories and techniques to support safe, predictable, and efficient impact testing at the Sandia National Laboratories TA-III Mechanical Shock Complex (MSC), located in Building 6570. The two testing instruments used at the MSC are the 20-inch actuator, which is a launcher that propels sleds down an indoor track, and an indoor 6-in bore compressed-gas powered cannon. The theories and techniques presented derive from basic mechanical engineering principles but are significantly informed and validated by testing experience at the MSC.

42 ENGINEERING↗

LANL Meteorological Program: 2022 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA- 54B, and TA-16B were installed in 2021, and will be included in the 2023 data completeness/quality report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗

LANL Meteorological Program: 2023 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA-54B, and TA-16B have been in testing since they were installed in 2021, and will be included in a future data completeness report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗

Searching for Novel Chemistry in Exoplanetary Atmospheres Using Machine Learning for Anomaly Detection

Abstract The next generation of telescopes will yield a substantial increase in the availability of high-quality spectroscopic data for thousands of exoplanets. The sheer volume of data and number of planets to be analyzed greatly motivate the development of new, fast, and efficient methods for flagging interesting planets for reobservation and detailed analysis. We advocate the application of machine learning (ML) techniques for anomaly (novelty) detection to exoplanet transit spectra, with the goal of identifying planets with unusual chemical composition and even searching for unknown biosignatures. We successfully demonstrate the feasibility of two popular anomaly detection methods (local outlier factor and one-class support vector machine) on a large public database of synthetic spectra. We consider several test cases, each with different levels of instrumental noise. In each case, we use receiver operating characteristic curves to quantify and compare the performance of the two ML techniques.

Astronomy & Astrophysics↗

A study of real-world micrograph data quality and machine learning model robustness

Abstract Machine-learning (ML) techniques hold the potential of enabling efficient quantitative micrograph analysis, but the robustness of ML models with respect to real-world micrograph quality variations has not been carefully evaluated. We collected thousands of scanning electron microscopy (SEM) micrographs for molecular solid materials, in which image pixel intensities vary due to both the microstructure content and microscope instrument conditions. We then built ML models to predict the ultimate compressive strength (UCS) of consolidated molecular solids, by encoding micrographs with different image feature descriptors and training a random forest regressor, and by training an end-to-end deep-learning (DL) model. Results show that instrument-induced pixel intensity signals can affect ML model predictions in a consistently negative way. As a remedy, we explored intensity normalization techniques. It is seen that intensity normalization helps to improve micrograph data quality and ML model robustness, but microscope-induced intensity variations can be difficult to eliminate.

36 MATERIALS SCIENCE↗

How Should Machine Learning Be Successfully Used for Wind Speed Vertical Extrapolation?

An accurate characterization of the wind resource available at hub-height is required for an efficient and bankable wind farm project. However, direct measurement of wind speed at the constantly increasing height of the hub of commercial wind turbines is oftentimes challenging and expensive, so that it is common practice to vertically extrapolate the wind resource from lower and more easily accessible levels. Conventional techniques for wind speed vertical extrapolation include the use of a power law and a logarithmic profile. While simple, the limits in accuracy of these methods have been shown in various studies. Recently, machine learning has been proposed as a new method to vertically extrapolate winds. All the published studies on the topic assess the performance of machine learning techniques in vertically extrapolating the wind resource at the same location where the algorithm has been trained. However, in real-world applications, the wind resource is measured at the instrument location, but it then needs to be extrapolated at hub height at the location of the wind turbines within the find farm. To be able to fully recommend the use of machine learning techniques over the simple power law and logarithmic law, the spatial variability of the performance improvements of the machine learning approaches needs to be assessed. Here, we propose a round-robin validation of a machine learning-based method for wind speed extrapolation. We use 20 months of observations at four locations spanning a 100 km wide region at the Southern Great Plains (SGP) atmospheric observatory, in north-central Oklahoma. At each location, we train a random forest to predict 30-min average wind speed at 143 m AGL. We use as input features lidar wind speed at 65 m AGL, time of day, sonic anemometer wind speed at 4 m AGL, turbulent kinetic energy, and Obukhov length. First, we perform a same-site comparison of the performance of the proposed random forest against the conventional techniques for wind speed extrapolation (namely power law and logarithmic profile, with widely accepted stability corrections). We find that the random forest outperforms the power law in vertically extrapolating wind speed in all the considered stability regimes, with a 33% reduction in MAE for stable conditions, and a 31% reduction in unstable conditions. Similar results are found when comparing predictions of extrapolated winds from the logarithmic profile and the random forest with the observed values. Next, we propose a round-robin validation, to use the random forest trained at each site to extrapolate wind speed at the remaining three sites. We find that the performance of the random forest approach degrades when the algorithm is tested at a site different than the training one. However, even under those circumstances, the machine learning-based approach still outperforms the conventional techniques for wind speed extrapolation, with, on average, a reduction in mean absolute error between 15 and 20% over the conventional methods, with the largest benefits obtained under stable conditions.

Monte Carlo↗

Crystal growth and scintillation properties of pure and Tl-doped Cs 3 Cu 2 I 5

Here, the Bridgman crystal growth and scintillation properties of both undoped and Tl-doped Cs 3 Cu 2 I 5 are presented. This material is very attractive for gamma and X-ray detection applications, with a density of 4.53 g/cm 3 and effective atomic number of 51.9. Undoped Cs 3 Cu 2 I 5 had a light yield of 41,500 photons/MeV, with an energy resolution of 4.4% at 662 keV. Thallium doping at 0.5 mol % resulted in a much-improved scintillation response, in which light yield increased to 98,200 photons/MeV and energy resolution reduced to 3.3% at 662 keV. The X-ray excited emission is centered at 442 nm for the undoped and 500 nm for the Tl-doped crystals. The undoped emission is broad, typical of excitonic emission, while thallium doping results in an even broader band with features of both the undoped and thallium defect-mediated emissions.

36 MATERIALS SCIENCE↗

The Completed SDSS-IV Extended Baryon Oscillation Spectroscopic Survey: N-body Mock Challenge for Galaxy Clustering Measurements

We develop a series of N-body data challenges, functional to the final analysis of the extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 (DR16) galaxy sample. The challenges are primarily based on high-fidelity catalogues constructed from the Outer Rim simulation - a large box size realization (3h(-1) Gpc) characterized by an unprecedented combination of volume and mass resolution, down to 1.85 x 10(9) h(-1)M(circle dot). We generate synthetic galaxy mocks by populating Outer Rim haloes with a variety of halo occupation distribution (HOD) schemes of increasing complexity, spanning different redshift intervals. We then assess the performance of three complementary redshift space distortion (RSD) models in configuration and Fourier space, adopted for the analysis of the complete DR16 eBOSS sample of Luminous Red Galaxies (LRG5). We find all the methods mutually consistent, with comparable systematic errors on the Alcock-Paczynski parameters and the growth of structure, and robust to different HOD prescriptions - thus validating the robustness of the models and the pipelines used for the baryon acoustic oscillation (BAO) and full shape clustering analysis. In particular, all the techniques are able to recover and alpha(11) to within 0.9 per cent, and f sigma(8) to within 1.5 per cent. As a by-product of our work, we are also able to gain interesting insights on the galaxy-halo connection. Our study is relevant for the final eBOSS DR16 'consensus cosmology', as the systematic error budget is informed by testing the results of analyses against these high-resolution mocks. In addition, it is also useful for future large-volume surveys, since similar mock-making techniques and systematic corrections can be readily extended to model for instance the Dark Energy Spectroscopic Instrument (DESI) galaxy sample.

cosmology: theory, large-scale structure of Univer↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

An automated workflow to screen alkene reductases using high-throughput thin layer chromatography

Background: Synthetic biology efforts often require high-throughput screening tools for enzyme engineering campaigns. While innovations in chromatographic and mass spectrometry-based techniques provide relevant structural information associated with enzyme activity, these approaches can require cost-intensive instrumentation and technical expertise not broadly available. Moreover, complex workflows and analysis time can significantly impact throughput. To this end, we develop an automated, 96-well screening platform based on thin layer chromatography (TLC) and use it to monitor in vitro activity of a geranylgeranyl reductase isolated from Sulfolobus acidocaldarius (SaGGR). Results: Unreduced SaGGR products are oxidized to their corresponding epoxide and applied to thin layer silica plates by acoustic printing. These derivatives are chromatographically separated based on the extent of epoxidation and are covalently ligated to a chromophore, allowing detection of enzyme variants with unique product distributions or enhanced reductase activity. Herein, we employ this workflow to examine farnesol reduction using a codon-saturation mutagenesis library at the Leu377 site of SaGGR. We show this TLC-based screen can distinguish between fourfold differences in enzyme activity for select mutants and validated those results by GC–MS. Conclusions: With appropriate quantitation methods, this workflow can be used to screen polyprenyl reductase activity and can be readily adapted to analyze broader catalyst libraries whose products are amenable to TLC analysis.

09 BIOMASS FUELS↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Astrometric Calibration and Performance of the Dark Energy Spectroscopic Instrument Focal Plane

Abstract The Dark Energy Spectroscopic Instrument, consisting of 5020 robotic fiber positioners and associated systems on the Mayall telescope at Kitt Peak, Arizona, is carrying out a survey to measure the spectra of 40 million galaxies and quasars and produce the largest 3D map of the universe to date. The primary science goal is to use baryon acoustic oscillations to measure the expansion history of the universe and the time evolution of dark energy. A key function of the online control system is to position each fiber on a particular target in the focal plane with an accuracy of 11 μ m rms 2D. This paper describes the set of software programs used to perform this function along with the methods used to validate their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Depth Mass Spectrometry-Based Single-Cell and Nanoscale Proteomics

Leukemic stem cells are highly dynamic and heterogeneous. Analysis of leukemic stem cells at the single cell level should provide a wealth of insights that would not be possible using bulk measurements. Mass spectrometry (MS)-based proteomic workflows can quantify hundreds or thousands of proteins from a biological sample and has proven invaluable for biomedical research, but samples comprising large numbers of cells are typically required due to limited sensitivity. Recent developments in sample processing, chromatographic separations and MS instrumentation are now extending in-depth proteome profiling to single mammalian cells. We describe specific techniques that increase the sensitivity of single-cell proteomics by orders of magnitude, enabling the promise of single cell proteomics to become a reality. We anticipate such techniques could significantly advance our understanding of leukemic stem cells.

Liang, Yiran↗

Overview of the Magnetic Resonance Capabilities at INL

The aim of this presentation is to give a broad overview of the magnetic resonance capabilities at Idaho National Laboratory and how the technique is implemented within the different directorates at the lab. Historically, the high-field NMR instrumentation has been used by our Energy & Environment Science and Technology (EES&T) directorate primarily as a characterization tool for synthetic chemistry work, but we have been actively trying to expand the use of the instrumentation into our Nuclear Science and Technology (NS&T) and National and Homeland Security (NHS) directorates. The expanded scope of work has ranged from solid-state characterization of biomass, analysis of electrolyte materials from lithium ion batteries, quantification of extracted critical materials, and measurement of metal-ligand complexes using ligands proposed for use in the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗