Search NASA⌕ Search

SEARCH · Search NASA

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Comparison of MOCLD With PLD Ba(x)Sr(1-x)TiO3 Thin Films on LaAlO3 for Tunable Microwave Applications

Historically, tunable dielectric devices using thin crystalline Ba(x)Sr(1-x)TiO3 (BST) films deposited on lattice-matched substrates, such as LaAlO3, have generally been grown using pulsed laser deposition (PLD). Highly oriented BST films can be grown by PLD but large projects are hampered by constraints of deposition area, deposition time and expense. The Metal-Organic Chemical Liquid Deposition (MOCLD) process allows for larger areas, faster turnover and lower cost. Several BST films deposited on LaAlO3 by MOCLD have been tested in 16 GHz coupled microstrip phase shifters. They can be compared with many PLD BST films tested in the same circuit design. The MOCLD phase shifter performance of 293 deg. phase shift with 53 V/micron dc bias and a figure of merit of 47 deg./dB is comparable to the most highly oriented PLD BST films. The PLD BST films used here have measured XRD full-width-at-half-maxima (FWHM) as low as 0.047 deg.. The best FWHM of these MOCLD BST films has been measured to be 0.058 deg.

VanKeuls, F. W.↗

Micromachined Tunable Fabry-Perot Filters for Infrared Astronomy

Micromachined Fabry-Perot tunable filters with a large clear aperture (12.5 to 40 mm) are being developed as an optical component for wide-field imaging 1:1 spectroscopy. This program applies silicon micromachining fabrication techniques to miniaturize Fabry-Perot filters for astronomical science instruments. The filter assembly consists of a stationary etalon plate mated to a plate in which the etalon is free to move along the optical axis on silicon springs attached to a stiff silicon support ring. The moving etalon is actuated electrostatically by electrode pairs on the fixed and moving etalons. To reduce mass, both etalons are fabricated by applying optical coatings to a thin freestanding silicon nitride film held flat in drumhead tension rather than to a thick optical substrate. The design, electro-mechanical modeling, fabrication, and initial results will be discussed. The potential application of the miniature Fabry-Perot filters will be briefly discussed with emphasis on the detection of extra-solar planets.

Barclay, Richard↗

A Comparison of MOCLD With PLD Ba(x)Sr(1-x)TiO3 Thin Films on LaAlO3 for Tunable Microwave Applications

Historically, tunable dielectric devices using thin crystalline Ba(x)Sr(1-x),TiO3 (BST) films deposited on lattice-matched substrates, such as LaAlO3 have generally been grown using pulsed laser deposition (PLD). Highly oriented BST films can be grown by PLD but large projects are hampered by constraints of deposition area, deposition time and expense. The Metal-Organic Chemical Liquid Deposition (MOCLD) process allows for larger areas, faster turnover and lower cost. Several BST films deposited on LaAlO, by MOCLD have been tested in 16 GHz coupled microstrip phase shifters. They can be compared with many PLD BST films tested in the same circuit design. The MOCLD phase shifter performance of 293 degree phase shift with 53 V/micron dc bias and a figure of merit of 47 degree/dB is comparable to the most highly oriented PLD BST films. The PLD BST films used here have measured XRD full-width-at-half-maxima (FWHM) as low as 0.047 degrees. The best FWHM of these MOCLD BST films has been measured to be 0.058 degrees.

VanKeuls, F. W.↗

Tunable Solid-Etalon Filter for the ICESat/GLAS 532 nm Channel Lidar Receiver

The Geoscience Laser Altimeter System (GLAS) was launched into Earth orbit on board the Ice, Cloud and land Elevation Satellite (ICESat) on January 12, 2003. GLAS is a laser altimeter designed to measure ice-sheet topography and associated temporal changes, as well as cloud and atmospheric properties. Each (of the three identical) GLAS lasers is a diode pumped, Q-switched Nd:YAG laser with energy levels of 75 mJ (1064 nm) and 35 mJ (532 nm). The infrared pulse is used for both surface altimetry and atmospheric measurements while the green pulse is used primarily for atmospheric measurements. The receiver uses a 1 meter diameter telescope. We report on the tunable solid-etalon filter used in the ICESat/GLAS 532 nm channel lidar receiver.

Krainak, Michael A.↗

A Large Aperture Fabry-Perot Tunable Filter Based On Micro Opto Electromechanical Systems Technology

A research and development effort sponsored by the NASA Goddard Spaceflight Center (GSFC) is focused on applying Micro Opto Electromechanical Systems (MOEMS) technology to create a miniature Fabry-Perot tunable etalon for space and ground-based near infrared imaging spectrometer applications. Unlike previous devices developed for small-aperture telecommunications systems, the GSFC research is directed toward a novel 12 - 40 mm aperture for astrophysical studies, including emission line imaging of galaxies and nebulae, and multi-spectral redshift surveys in the 1.1 - 2.3 micron wavelength region. The MOEMS design features integrated electrostatic scanning of the 11-micron optical gap, and capacitance micrometry for closed loop control of parallelism within a 10-nm tolerance. The low thermal mass and inertia inherent in MOEMS devices allows for rapid cooling to the proposed 30 K operating temperature, and high frequency response. Achieving the proposed 6-nm aperture flatness (with an effective finesse of 50) represents the primary technical challenge in the current 12-mm prototype.

Greenhouse, Matt↗

Difference-frequency-based tunable absorption spectrometer for detection of atmospheric formaldehyde

High-sensitivity detection of formaldehyde (CH2O) at 3.5315 micrometers (2831.64 cm-1) is reported with a diode-laser-pumped, fiber-coupled, periodically poled LiNbO3 spectroscopic source. This source replaced the Pb-salt diode laser Dewar assembly of an existing tunable diode-laser absorption spectrometer designed for ultrasensitive detection of CH2O. Spectra are recorded with 2f-modulation spectroscopy and zero-air rapid background subtraction. Initial measurements reported here, determined from multiple measurements of a flowing 7.7 parts per billion by volume (ppbv, parts in 10(9)) CH2O in air mixture, indicate replicate precisions as low as 0.24 ppbv.

Non-NASA Center↗

Airborne Measurements of Formaldehyde Employing a Tunable Diode Laser Absorption Spectrometer During TRACE-P

This final report summarizes the progress achieved over the entire 3-year proposal period including two extensions spanning 1 year. These activities include: 1) Preparation for and participation in the NASA 2001 TRACE-P campaign using our airborne tunable diode laser system to acquire measurements of formaldehyde (CH2O); 2) Comprehensive data analysis and data submittal to the NASA archive; 3) Follow up data interpretation working with NASA modelers to place our ambient CH2O measurements into a broader photochemical context; 4) Publication of numerous JGR papers using this data; 5) Extensive follow up laboratory tests on the selectivity and efficiency of our CH20 scrubbing system; and 6) An extensive follow up effort to assess and study the mechanical stability of our entire optical system, particularly the multipass absorption cell, with aircraft changes in cabin pressure.

Fried, Alan↗

High-Temperature Superconducting/Ferroelectric, Tunable Thin-Film Microwave Components

At the NASA Lewis Research Center, ferroelectric films such as SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3, are being used in conjunction with YBa(sub 2)Cu(sub 3)O(sub 7-delta) high-temperature superconducting thin films to fabricate tunable microwave components such as filters, phase shifters, and local oscillators. These structures capitalize on the variation of the dielectric constant of the ferroelectric film upon the application of a direct-current electric field, as well as on the low microwave losses of high-temperature superconductors relative to their conventional conductor counterparts. For example, the surface resistance for a YBa(sub 2)Cu(sub 3)O(sub 7-delta) thin film at 10 GHz and 77 K is more than two orders of magnitude lower than that of copper or gold at the same temperature and frequency. SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3 films are used because their crystal structure and lattice parameters are similar to those of YBa(sub 2)Cu(sub 3)O(sub 7-delta), thus enabling the growth of highly textured YBa(sub 2)Cu(sub 3)O(sub 7-delta) films with high critical current densities (i.e., greater than 1 MA/sq cm) on the underlying ferroelectric film, or alternatively, of highly textured ferroelectric film on the underlying YBa(sub 2)Cu(sub 3)O(sub 7-delta) film.

Miranda, Felix A.↗

Measurements of Trace Gases Using a Tunable Diode Laser

This report is the final report for "Measurements of Trace Gases Using a Tunable Diode Laser." The tasks outlined in the proposal are listed below with a brief comment. The publications and the conference presentations are listed. Finally, the important publications are attached. The Cooperative Agreement made possible a research effort to produce high- precision and high-accuracy in-situ measurements of carbon monoxide, methane and nitrous oxide on the WB-57 during the CRYSTAL-FACE and pre-AVE field campaigns and to analyze these measurements. These measurements of CO and CH4 were of utmost importance to studies of the radiative effects of clouds. Some important results of the CRYSTAL-FACE program were contained in two scientific papers (attached). This Cooperative Agreement allowed the participation of the Argus instrument in the program and the analysis of the data.

Jost, Hans-Juerg↗

The MVACS Tunable Diode Laser Spectrometers

Two independent tunable diode laser spectrometers are resident aboard the Mars Polar Lander as part of the Mars Volatile and Climate Surveyor payload.

MVACS Diode Laser Spectrometer Mars Mars Volatile ↗

Tunable All-Solid-State Local Oscillators to 1900 GHz

We present a status report of an ongoing effort to develop robust tunable all-solid-state sources up to 1900 GHz for the Heterodyne Instrument for the Far Infrared (HIFI) on the Herschel Space Observatory. GaAs based multi-chip power amplifier modules at W-band are used to drive cascaded chains of multipliers. We have demonstrated performance from chains comprised of four doublers up to 1600 GHz as well as from a x2x3x3 chain to 1900 GHz. Measured peak output power of 23 (micro)W at 1782 GHz and 2.6 (micro)W at 1900 GHz has been achieved when the multipliers are cooled to 120K. The 1900 GHz tripler was pumped with a four anode tripler that produces a peak of 4 mW at 630 GHz when cooled to 120 K. We believe that these sources can now be used to pump hot electron bolometer (HEB) heterodyne mixers.ter (HEB) heterodyne mixers.

local oscillator↗

Tunable graded rod laser assembly

A tunable laser assembly including a pair of radially graded indexed optical segments aligned to focus the laser to form an external resonant cavity with an optical axis, the respective optical segments are retativity moveable along the optical axis and provide a variable et aion gap sufficient to permit variable tuning of the laser wavelength without altering the effective length of the resonant cavity. The gap also include a saturable absorbing material providing a passive mode-locking of the laser.

AuYeung, John C.↗

Quasi-monolithic tunable optical resonator

An optical resonator has a piezoelectric element attached to a quasi-monolithic structure. The quasi-monolithic structure defines an optical path. Mirrors attached to the structure deflect light along the optical path. The piezoelectric element controllably strains the quasi-monolithic structure to change a length of the optical path by about 1 micron. A first feedback loop coupled to the piezoelectric element provides fine control over the cavity length. The resonator may include a thermally actuated spacer attached to the cavity and a mirror attached to the spacer. The thermally actuated spacer adjusts the cavity length by up to about 20 microns. A second feedback loop coupled to the sensor and heater provides a coarse control over the cavity length. An alternative embodiment provides a quasi-monolithic optical parametric oscillator (OPO). This embodiment includes a non-linear optical element within the resonator cavity along the optical path. Such an OPO configuration is broadly tunable and capable of mode-hop free operation for periods of 24 hours or more.

Arbore, Mark↗

Tunable resonator-based devices for producing variable delays and narrow spectral linewidths

Devices with two or more coupled resonators to produce narrow spectral responses due to interference of signals that transmit through the resonators and techniques for operating such devices to achieve certain operating characteristics are described. The devices may be optical devices where optical resonators such as whispering gallery mode resonators may be used. In one implementation, at least one of the coupled optical resonators is a tunable resonator and is tuned to change its resonance frequency to tune the spectral response of the device. The described devices and techniques may be applied in optical filters, optical delays, optical waveform generators, and other applications.

Savchenkov, Anatoliy↗

Tunable quantum well infrared detector

A novel infrared detector (20, 20', 20), is provided, which is characterized by photon-assisted resonant tunneling between adjacent quantum wells (22a, 22b) separated by barrier layers (28) in an intrinsic semiconductor layer (24) formed on an n.sup.+ substrate (26), wherein the resonance is electrically tunable over a wide band of wavelengths in the near to long infrared region. An n.sup.+ contacting layer (34) is formed over the intrinsic layer and the substrate is n.sup.+ doped to provide contact to the quantum wells. The detector permits fabrication of arrays (30) (one-dimensional and two-dimensional) for use in imaging and spectroscopy applications.

Maserjian, Joseph↗

Method for generation of tunable far infrared radiation from two-dimensional plasmons

Tunable far infrared radiation is produced from two-dimensional plasmons in a heterostructure, which provides large inversion-layer electron densities at the heterointerface, without the need for a metallic grating to couple out the radiation. Instead, a light interference pattern is produced on the planar surface of the heterostructure using two coherent laser beams of a wavelength selected to be strongly absorbed by the heterostructure in order to penetrate through the inversion layer. The wavelength of the far infrared radiation coupled out can then be readily tuned by varying the angle between the coherent beams, or varying the wavelength of the two interfering coherent beams, thus varying the periodicity of the photoconductivity grating to vary the wavelength of the far infrared radiation being coupled out.

Katz, Joseph↗

Tunable Infrared Laser Instruments for Airborne Atmospheric Studies

Tunable infrared laser-based instruments on airborne platforms have provided invaluable contributions to atmospheric studies over the past several decades. This paper presents an overview of some recent studies and developments using this approach that were presented at the 2007 Field Laser Applications in Industry and Research (FLAIR, http://www.inoa.it/flair/) conference in Florence, Italy. The present overview only covers select in situ absorption-based instruments that were presented in the airborne session at this conference. In no case are comprehensive details presented. These details can be found in the numerous references given. Additional approaches based upon cavity-enhanced and photoacoustic measurements, which are also making invaluable contributions in airborne atmospheric studies, are not discussed in this brief overview.

Fried, A.↗

Frequency-Tunable Pre-stabilized lasers for LISA via Stabilized Lasers for LISA via Sideband Locking

This viewgraph presentation discusses a major potential source of noise for the Laser Interferometer Space Antenna (LISA) that is the laser frequency noise and the proposed mechanism to suppress the unstabilized frequency fluctuations. These fluctuations must be suppresed by about 12 orders of magnitude to achieve a stability that is sufficient for the detection of gravitational waves. This presentation reviews present a modification to the traditional cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This presentation also discusses measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements and a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilization stage.

Livas, Jeffrey↗