Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Alvin Tollestrup (1924-2020): A Life in Science

Alvin Tollestrup was a physicist and engineer of uncommon insight, intuition, and ingenuity who was revered in life for his essential leadership in the development of superconducting magnets for high-energy accelerators. He exhibited a matchless mastery of what he called freshman physics — though his mastery hardly ended there — and an uncanny gift for joining careful measurements with transparent calculations to reveal the essence of a subject. To watch Alvin at work was to learn how a true scientist formulates and solves a problem. He had other gifts: a nose for significant problems in both science and technology, the ability to draw talented people to an important cause, and a mentor's instinct for spotting gifted junior colleagues and helping them to mature as engineers and scientists. He was also good company! Alvin brought his keen vision about what constitutes important science, along with powerful ambition for the institution and for fundamental science, to considerat ions about Fermilab's future. His questions were uniformly probing, his opinions unfailingly interesting, and his appetite for work consistently inspiring. Among Alvin's many contributions to experimental particle physics — in a career that spanned seven decades — the rich achievements of the Collider Detector at Fermilab Collaboration, of which he was a founder and an enduring leader, stand out. The discovery of the top quark in 1995 earned worldwide acclaim. He reaped individual accolades as well, including election to the National Academy of Sciences. The National Medal of Technology, conferred in 1989, recognized Alvin’s leading role in developing superconducting magnets for Fermilab's Tevatron. Universities Research Association created the Tollestrup Award for Postdoctoral Research, commemorating Alvin's avuncular support for young scientists. This volume celebrates Alvin Tollestrup’s career and the rich, fulfilling life he led beyond the laboratory. Contributions from colleagues and family illuminate many facets of this remarka! ble figure. May old friends savor the memory of the Alvin they knew, while discovering less-familiar parts of his history; and may readers who did not have the opportunity to know Alvin firsthand find inspiration in his exemplary life in science.

Palmer, Mark↗

Exploration of signal processing methods for superconducting magnet and quench data

Quenching is the phenomenon of a superconducting magnetic material carrying current transitioning into a regular conducting material. This may cause severe and irreparable damage to the superconductor due to Joule heating. The Magnet Department at Fermi National Accelerator Laboratory (FNAL) has acquired experimental data through quench antenna arrays that are recorded when the quench is detected. These data are in terms of voltage signals that are sampled at 100kHz for several minutes. There are multiple channels and each channel provides a data set of more than 20 million observations, while there is one channel, called the trigger channel which shows the time when quench is detected. Despite some advancements that were made including machine learning, data complexity still shadows the progress. In this work, we studied a multi-resolution analysis of the quench antenna data through the Haar wavelet transform. In particular, we applied the maximally overlapped discrete w avelet transform (MODWT) of a suitable level L to the given data and then projected it onto the wavelet basis. This decomposes a given signal (Original data) $x ϵ \mathbb{R}^N$ into $L + 1$ subspaces of $\mathbb{R}^N$. One of the subspaces called the approximation, captures the trend of the signal, and the others, called the details, capture the fluctuations at different frequency bands. This decomposition provides a clear trend of the data at a suitable level and also various activities (spikes) are seen in the details of the decomposition at every level. These spikes might reveal some information about the quench under investigation but in any case, give information about magnet behavior. Also, this decomposition is seen to be very useful in removing noise present in the data due to the source or mechanism of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strong interplay between superluminosity and radiation friction during direct laser acceleration

Using a test-particle model, we examine direct laser acceleration of electrons within a magnetic filament that has been shown to form inside a laser-irradiated plasma. We focus on ultra-high intensity interactions where the force of radiation friction caused by electron emission of electromagnetic radiation must be taken into account. It is shown that even relatively weak superluminosity of laser wave fronts—the feature that has been previously neglected—qualitatively changes the electron dynamics, leading to a so-called attractor effect. As a result of this effect, electrons with various initial energies reach roughly the same maximum energy and emit roughly the same power in the form of x-rays and gamma-rays. Our analysis implies that the primary cause of the superluminosity is the laser-heated plasma. The discovered strong interplay between superluminosity and radiation friction is of direct relevance to laser-plasma interactions at high-intensity multi-PW laser facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quench Performance of the First Pre-series AUP Cryo-assembly

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S. contributions to the HL-LHC. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of the two interaction points. Each cryo-assembly consists of two 4.2 m long Nb 3 Sn quadrupole magnets with aperture 150 mm and operating gradient 132.6 T/m. The first pre-series cryo-assembly has been fabricated and successfully tested at the horizontal test facility at Fermi National Accelerator Laboratory. Here in this manuscript we report the quench test results of the LQXFA/B-01 cryo-assembly. The primary objective of the horizontal test is full cryo-assembly qualification and validation of the performance requirements.

43 PARTICLE ACCELERATORS↗

Initial Feasibility and Clinical Implementation of Daily MR-Guided Adaptive Head and Neck Cancer Radiation Therapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation

This prospective study is, to our knowledge, the first report of daily adaptive radiation therapy (ART) for head and neck cancer (HNC) using a 1.5T magnetic resonance imaging-linear accelerator (MR-linac) with particular focus on safety and feasibility and dosimetric results of an online rigid registration-based adapt to position (ATP) workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultranarrow electroluminescence from magnetic excitons in the van der Waals antiferromagnetic semiconductor NiPS 3

Electrically driven light emission from two-dimensional (2D) semiconducting materials has enabled numerous optoelectronic technologies, including light-emitting diodes, solid-state lasers, and single-photon sources for quantum communication. Here we report ultranarrow electroluminescence from the magnetic excitonic state of the van der Waals antiferromagnetic semiconductor NiPS 3 . This electroluminescence is enabled by the fabrication of gate-tunable NiPS 3 devices that remain electrically conductive below the antiferromagnetic ordering temperature of 155 K, ultimately allowing field-effect mobilities of 1.3 cm 2 V –1 s –1 and 4.5 cm 2 V –1 s –1 to be directly measured at room temperature and 7 K, respectively. By applying a high-frequency square wave voltage to the gate electrode of the resulting field-effect transistors, electroluminescence is capacitively induced from the magnetic excitons of NiPS 3 . Due to the coupling of these excitons with the underlying NiPS 3 antiferromagnetic order, the electroluminescence has an ultranarrow linewidth of 1 meV and a high degree of linear polarization (ρ = 0.78). In addition to facilitating fundamental studies of the coupling between spin states and excitons in van der Waals magnetic semiconductors, this work will accelerate the development of emerging 2D opto-spintronic applications.

two-dimensional materials↗

Development of Superconducting RF Cavity in Traveling-Wave Regime at Fermilab

Niobium Superconducting RF (SRF) cavities have a theoretical peak magnetic field which limits the accelerating field to 50-60 MV/m. Presently, all SRF cavities operate in a Standing Wave (SW) resonance field in which particles experience an accelerating force alternating from zero to peak. In contrast, a resonance field in Traveling Wave (TW) mode propagates along with a structure, so particles in such field can experience a constant acceleration force and could have higher energy gain than that of SW mode. This phenomenon is defined by the cavity’s transit time factor, T. A TW structure proposed in an early study achieves T ~0.9, suggesting an increase in acceleration per structure by more than 20% compared to a SW structure (T ~0.7). The early stages of developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. It demonstrated the TW resonance excitation at room temperature in the “as-fabricated” 3-cell structure. Here we report recent progresses and the first cryogenic testing of the 3-cell TW cavity in 2 K liquid helium at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Relativistic Shear Boundary Layer and the Gamma-Ray Emission of GW170817

We present an analysis of the radiation characteristics of kinetic shear boundary layers created by relativistic plasma jets. Using a model of electromagnetic field data based on particle-in-cell simulations of an electron–ion plasma, we solve the motion of individual test electrons and compute their instantaneous radiated power and peak frequency. By analyzing a large number of test electrons in this manner, we find two distinct electron populations present around the shear boundary layer. The most highly radiative electrons execute looping motion due to crossed electric and magnetic fields as they are accelerated along the bulk flow of the jet, and eventually cross the shear boundary interface at steep angles. Electrons that never cross the shear boundary interface radiate much less energy as a group. Summing over all of the highly radiative electrons, we compute the distribution of the total radiated energy as a function of the angle relative to the bulk flow. Furthermore, this result has important potential implications for the observed radiation output of short gamma-ray bursts viewed at large angles from the jet axis, such as the neutron star merger event GW170817/GRB 170817A.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Optimization of a traveling wave superconducting radiofrequency cavity for upgrading the International Linear Collider

The standing wave TESLA niobium-based superconducting radio frequency structure is limited to an accelerating gradient of about 50 MV/m by the critical rf magnetic field. To break through this barrier, we explore the option of niobium-based traveling wave (TW) structures. Optimization of TW structures was done considering experimentally known limiting electric and magnetic fields. It is shown that a TW structure can have an accelerating gradient above 70 MeV/m that is about 1.5 times higher than contemporary standing wave structures with the same critical magnetic field. The other benefit of TW structures shown is R/Q about 2 times higher than the TESLA structure that reduces the dynamic heat load by a factor of 2. A method is proposed how to make TW structures multipactor-free. Some design proposals are offered to facilitate fabrication. Further increase of the real-estate gradient (equivalent to 80 MV/m active gradient) is also possible by increasing the length of the accelerating structure because of higher group velocity and cell-to-cell coupling. Realization of this work opens paths to International Linear Collider energy upgrades beyond 1 to 3 TeV in competition with CLIC. The paper will discuss corresponding opportunities and challenges.

43 PARTICLE ACCELERATORS↗

First-principles Prediction of X-Ray Polarization from Magnetic Reconnection in High-frequency BL Lacertae Objects

Relativistic magnetic reconnection is a potential particle acceleration mechanism for high-frequency BL Lac objects (HBLs). The Imaging X-ray Polarimetry Explorer (IXPE) scheduled to launch in 2021 has the capability to probe the evolution of magnetic field in HBLs, examining the magnetic reconnection scenario for the HBL flares. In this paper, we make the first attempt to self-consistently predict HBL X-ray polarization signatures arising from relativistic magnetic reconnection via combined particle-in-cell and polarized radiation transfer simulations. Here, we find that although the intrinsic optical and X-ray polarization degrees are similar on average, the X-ray polarization is much more variable in both the polarization degree and angle (PD and PA). Given the sensitivity of the IXPE, it may obtain one to a few polarization data points for one flaring event of nearby bright HBLs Mrk 421 and 501. However, it may not fully resolve the highly variable X-ray polarization. Due to temporal depolarization, where the integration of photons with variable polarization states over a finite period of time can lower the detected PD, the measured X-ray PD can be considerably lower than the optical counterpart or even undetectable. The lower X-ray PD than the optical thus can be a characteristic signature of relativistic magnetic reconnection. For very bright flares where the X-ray polarization is well resolved, relativistic magnetic reconnection predicts smooth X-ray PA swings, which originate from large plasmoid mergers in the reconnection region.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Comment on “Nonideal Fields Solve the Injection Problem in Relativistic Reconnection”

Sironi (hereafter S22) reported the correlation between high-energy particles and their crossings of regions with electric field larger than magnetic field (E > B regions) in kinetic simulations of relativistic magnetic reconnection. They claim that E > B regions (for vanishing guide fields) accelerate particles to the injection energy γ inj ~ σ (magnetization). S22 shows that if test particles are reset to low energies in E > B regions, injection is suppressed. Here, we reexamine these claims using a simulation resembling the reference case in S22 with no guide field. We show that E > B regions contribute very little to injection (~ 10% γ inj ) as they only host particles for a short duration. The energization before any E > B crossings has a comparable contribution, indicating E > B regions are not unique for pre-acceleration. A new test-particle simulation that zeroes out E during E > B does not strongly influence injection. We suggest that the procedure to exclude E > B acceleration in S22 partly removes acceleration outside E > B, leading to a false conclusion.

79 ASTRONOMY AND ASTROPHYSICS↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Fiber Optic Sensing to Identify Locations of Resistive Transitions in REBCO Conductors and Magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-x (REBCO, RE = rare earth) can generate strong magnetic fields that are promising for applications in particle accelerators and compact fusion reactors. Traditionally, voltage taps are installed in superconducting magnets to measure the voltage signals due to resistive transitions. The voltage-tap-based diagnostics is important for the development of magnet technology as it can help pinpoint the locations in the magnet windings that limit the magnet performance. The architecture of the multi-tape REBCO cable such as CORC wires, however, makes it difficult to apply the voltage-tap-based diagnostics to identify the locations of resistive transitions. Distributed fiber optic sensing (DFOS) has the potential to address this issue. In this paper, we report the measurements of thermal strain along a CORC wire based on optical frequency domain reflectometry with a maximum spatial resolution of 0.65 mm and a temporal resolution of 10 Hz. The optical fiber is co-wound with the CORC wire that is epoxy impregnated. During the test, current was increased until a resistive transition occurred in the conductor. The spectrum shift of the reflected light along the fiber was recorded. The results suggested that with proper thermal isolation from the cryogen, DFOS can be used to identify the locations of resistive transitions in CORC wires and magnets. In conclusion, the results will allow a better understanding of the causes of resistive transitions in REBCO conductors and magnets, which will help improve the REBCO magnet technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MLSPICE: Machine Learning based SPICE Modeling Platform for Power Magnetics

Electrical power converters are critical to a wide range of applications ranging from renewable integration to transportation electrification, and can be a key factor determining the size, weight, and efficiency of energy conversion systems. Magnetic components are typically the largest and least efficient components in power electronics. While there have been major strides in the modeling and analysis of power semiconductor devices and circuit simulations, the necessary advances in the design of power magnetics have lagged. In this project, we have transformed the modeling and design of power magnetics with machine learning enabled methods and catalyze simultaneous disruptive improvements for ML-based power electronics design tools. A fully automated open-source machine learning based magnetics modeling platform – the MagNet project - with innovations in full stack have been developed to greatly accelerate the design process and provide new insights to magnetic material and geometry design. The ARPA-E funded MagNet platform contains three major building blocks: 1) a ML-Integrated Data Acquisition System (MIDAS): a highly automated data acquisition testbed which is capable of measuring a large number of magnetic cores with a wide range of electrical circuit excitations; 2) a ML-integrated Core Loss Model (MICLM): a machine-learning trained modeling method for modeling the core loss and saturation effects of magnetic materials for arbitrary excitation waveforms; 3) ML-guided Magnetics SPICE Simulation Tool (PMSPICE): a fully integrated CAD tool which can simulate the magnetics in SPICE. It can help the designers to quickly model the linear and non-linear characteristics of magnetic components and evaluate their behavior in SPICE simulations. The developed MagNet system has fully demonstrated the proposed performance target and has been open sourced to the entire power electronics community to advance the modeling and design of power magnetics from many different angles.

36 MATERIALS SCIENCE↗

Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC

By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.

43 PARTICLE ACCELERATORS↗