Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Liveness as a factor to evaluate memory vulnerability to soft errors

Memory, used by a computer to store data, is generally prone to faults, including permanent faults (i.e. relating to a lifetime of the memory hardware), and also transient faults (i.e. relating to some external cause) which are otherwise known as soft errors. Since soft errors can change the state of the data in the memory and thus cause errors in applications reading and processing the data, there is a desire to characterize the degree of vulnerability of the memory to soft errors. In particular, once the vulnerability for a particular memory to soft errors has been characterized, cost/reliability trade-offs can be determined, or soft error detection mechanisms (e.g. parity) may be selectively employed for the memory. In some cases, memory faults can be diagnosed by redundant execution and a diagnostic coverage may be determined.

Bramley, Richard Gavin↗

Geology and in situ stress of the MH-2 borehole, Idaho, USA: Insights into western Snake River Plain structure from geothermal exploration drilling

Project HOTSPOT, the Snake River Scientific Drilling Project (International Continental Scientific Drilling Program), tested for deep geothermal resources and examined the petrology of volcanic rocks with three drillholes in the central and western Snake River Plain (western USA). The MH-2 drillhole targeted fractured crystalline and hydrothermally altered basalt in the area of the Mountain Home Air Force Base (Idaho) to a total depth of 1821 m. At 1745 m depth the drillhole encountered flowing artesian hydrothermal fluids of at least 150 °C. We integrate geological analyses of core, image log, and borehole geophysical data, and in situ stress analyses to describe the structural environment that produces permeability for artesian flow. The rocks in the lower 540 m of the drillhole consist of basalt flows as much as 30 m thick, altered basalt, and thin sedimentary horizons. The mechanical stratigraphy is defined by nine mechanical horizons that are in three ranges of rock strength on the basis of experimentally determined strength data, core logging, and geophysical log signatures. Hydrothermal alteration products and mineralization in the core are associated with three highly faulted sections; the lowermost section is associated with the zone of flowing thermal water. Shear slip indicators on faults observed in core indicate slip ranging from pure strike slip to normal failure mechanisms in the stronger horizons. The borehole breakouts indicate that the maximum horizontal stress, SH, is oriented 047° ± 7°, and drilling-induced tensile fractures indicate that SH is oriented at 67° ± 21°. The in situ stress orientations exhibit little variation over the depth of the measured interval, but the SH magnitude varies with depth, and is best explained by an oblique normal fault stress regime. The geomechanical model indicates that if pore pressures at depth are elevated above the normal hydrostatic gradient, as observed here, the system has the potential to deform by mixed normal and strike-slip failure. Our observations and interpretations suggest that the MH-2 borehole was drilled into oblique normal faults that intersect a buried 300°-trending fault block masked by the basaltic volcanic complex. These data indicate that the transition from the central to western Snake River Plain is characterized by complex structures developed in response to a transitional stress state related to Snake River Plain and western Basin and Range stress regimes. Furthermore, the western Basin and Range stress and tectonic regime may extend from northern Nevada into western Idaho and may enhance the potential for geothermal resources by creating interconnected fracture and fault-related permeability at depth.

15 GEOTHERMAL ENERGY↗

Regional and Local Geothermal Potential Evaluation: Examples from the Great Basin, USA, Iceland and East Africa

In both tectonically and magmatically mediated geothermal systems, geologic structures play a crucial role in focusing geothermal fluid circulation in the upper crust. In a variety of geothermal provinces worldwide, normal and strike-slip faults, caldera related faults, as well as fractures and fissures related to dikes and other magmatic intrusions generate the fracture permeability utilized for geothermal circulation. Localities where the above structures intersect and interact are characterized by the most robust generation and maintenance of fracture permeability, and therefore are the most favorable conduits for geothermal circulation. We present an evaluation of the structural geometries that tend to generate high density faulting and fracturing and an evaluation of the orientations of those structures with respect to the ambient stress conditions in three regions of high geothermal potential; The Great Basin, USA, Iceland, and east Africa. These analyses provide first-order constraints on areas that have favorable conditions for permeability and where future exploration for geothermal resources could be focused. In the Great Basin, USA, fault step-overs, fault terminations and accommodation zones are among the most common structural settings of known geothermal activity. Analysis of the geometry of these structures with respect to the ambient stress conditions reveals locations where faults associated with these structures are favorably oriented for enhanced fracture permeability. In magmatically active extensional provinces, like Iceland and east Africa, heat associated with shallow magmatic intrusions beneath volcanic centers drives geothermal circulation in near-surface fracture permeability conduits. Accentuated fault and fracture density and fracture permeability is generated by both axially oriented faults and fractures associated with axial rift zones and radially oriented structures near volcanic centers. Although heat from magmatic intrusion is most robust at volcanic centers, a high density of young intrusions may actually result in decreased permeability through closing of fracture networks. The locations of these three types of features; axial faults and fractures, radial structures, and young magmatic intrusions, all play a critical role in determining the most favorable locations for fracture permeability and fluid flow in magmatic geothermal systems. Within and around the margins of volcanic centers, where radial structures associated with volcanic centers interact and intersect with axially oriented structures associated with axial extension are the most favorable locations for fracture permeability and geothermal fluid circulation in magmatic extensional geothermal systems.

15 GEOTHERMAL ENERGY↗

Discovering operating modes in telemetry data from the Shuttle Reaction Control System

This paper addresses the problem of detecting and diagnosing faults in physical systems, for which suitable system models are not available. An architecture is proposed that integrates the on-line acquisition and exploitation of monitoring and diagnostic knowledge. The focus is on the component of the architecture that discovers classes of behaviors with similar characteristics by observing a system in operation. A characterization of behaviors based on best fitting approximation models is investigated. An experimental prototype has been implemented to test it. Preliminary results in diagnosing faults of the reaction control system of the space shuttle are presented. The merits and limitations of the approach are identified and directions for future work are set.

Manganaris, Stefanos↗

Fault localization and analysis in semiconductor devices with optical-feedback infrared confocal microscopy

We report on a cost-effective optical setup for characterizing light-emitting semiconductor devices with optical-feedback confocal infrared microscopy and optical beam-induced resistance change.We utilize the focused beam from an infrared laser diode to induce local thermal resistance changes across the surface of a biased integrated circuit (IC) sample. Variations in the multiple current paths are mapped by scanning the IC across the focused beam. The high-contrast current maps allow accurate differentiation of the functional and defective sites, or the isolation of the surface-emittingp-i-n devices in the IC. Optical beam-induced current (OBIC) is not generated since the incident beam energy is lower than the bandgap energy of the p-i-n device. Inhomogeneous current distributions in the IC become apparent without the strong OBIC background. They are located at a diffraction-limited resolution by referencing the current maps against the confocal reflectance image that is simultaneously acquired via optical-feedback detection. Our technique permits the accurate identification of metal and semiconductor sites as well as the classification of different metallic structures according to thickness, composition, or spatial inhomogeneity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIR Glass Test Vehicle Designed to Characterize Process Materials

The exposure to harsh environments can result in reliability issues on highly dense electronic packages and circuit assemblies. One area of concern is electrochemical failure mechanisms caused by electrolytic corrosion, electrochemical migration (dendrites), and leakage currents under humid conditions. These no-fault and no-trouble found failure points are challenging to detect and to perform process control during the assembly process. The focus of this research centers on metallizing glass surface insulation resistance test vehicles to characterize materials on electronic packages and components that exhibit the highest risk of failure due to material interactions and process residues. Glass test vehicles provide a visual representation of materials when they are exposed to moisture content in the air. Harsh environments can cause material interactions resulting in morphology changes, opening, and release of active components. A transparent test vehicle is highly functional for environmental stress testing under temperature, humidity, and bias. The designed experiment will evaluate the effects of material and process residues that can undergo changes in behavior during application, which leads to local failures.

Capen, Bill↗

Current Pressure Transducer Application of Model-based Prognostics Using Steady State Conditions

Prognostics is the process of predicting a system's future states, health degradation/wear, and remaining useful life (RUL). This information plays an important role in preventing failure, reducing downtime, scheduling maintenance, and improving system utility. Prognostics relies heavily on wear estimation. In some components, the sensors used to estimate wear may not be fast enough to capture brief transient states that are indicative of wear. For this reason it is beneficial to be capable of detecting and estimating the extent of component wear using steady-state measurements. This paper details a method for estimating component wear using steady-state measurements, describes how this is used to predict future states, and presents a case study of a current/pressure (I/P) Transducer. I/P Transducer nominal and off-nominal behaviors are characterized using a physics-based model, and validated against expected and observed component behavior. This model is used to map observed steady-state responses to corresponding fault parameter values in the form of a lookup table. This method was chosen because of its fast, efficient nature, and its ability to be applied to both linear and non-linear systems. Using measurements of the steady state output, and the lookup table, wear is estimated. A regression is used to estimate the wear propagation parameter and characterize the damage progression function, which are used to predict future states and the remaining useful life of the system.

Fault Estimation↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

Rifting Processes at a Continent‐Ocean Transition Rift Revealed by Fault Analysis: Example of Dabbahu‐Manda‐Hararo Rift (Ethiopia)

Abstract Analyses of fault attributes have contributed to unraveling fault growth processes in diverse tectonic settings. By integrating such analysis at the scale of a fault population, we propose to investigate the characteristics of a rift that has evolved up to a stage typical of a continent‐ocean transition. We address this problem by considering Dabbahu‐Manda‐Hararo (DMH) rift segment (Central Afar, Ethiopia), recognized for being in a late rifting stage. We quantify fault azimuth, length, and throw attributes for 668 normal faults. Along DMH rift, the mean fault density is 0.87 ± 0.7 km/km 2 and the median tectonic strain ranges from 1.8% to 3.1% assuming a fault dip of 60° and 45°, respectively. Maximum tectonic strain (>10%) is found where the rift azimuth changes. Along‐rift variations in fault azimuth, length, and scaling relationships suggest a different stage of rifting in the northern part of the rift. We show that this difference can be attributed to the influence of the Dabbahu volcano located at the northern tip of the rift, which captured the propagating Manda‐Hararo rift in the last ~100 kyr. The morpho‐tectonic analysis reveals numerous common features with slow‐spreading ridge segments, such as the Lucky Strike segment located along the Mid‐Atlantic ridge (segment length, spreading rate, associated magmatic system) but also with intermediate and fast ones (axial valley, fault throws, and diking). This study reveals that a rift at the continent‐ocean transition may be characterized by a transient and evolutionary behavior that shares features with oceanic ridges from slow‐ to fast‐spreading rates.

Dumont, S.↗

Utah FORGE: Earth Model Mesh Data for Selected Surfaces

This submission contains a number of data files with vertices of meshed/interpolated surfaces used in the Phase 2B earth model. Examples include land surface (based on 10-meter DEM), the granitoid-basin fill contact, several faults, and also interpolated temperature isosurfaces for 175 and 225 degrees C. All data are georeferenced to UTM, zone 12N, NAD 83, NAVD 88.

15 GEOTHERMAL ENERGY↗

Experimental evidence for dynamic friction on rock fractures from frequency-dependent nonlinear hysteresis and harmonic generation: Low-Frequency Torsional Dynamic Friction

Frictional properties affect the propagation of high-amplitude seismic waves across rock fractures and faults. Laboratory evidence suggests that these properties can be measured in active seismic surveys, potentially offering a route to characterizing friction in situ. Here, we present experimental results from a subresonance torsional modulus and attenuation apparatus that utilizes micron-scale sinusoidal oscillations to probe the nonlinear stress-strain relation at a range of strain amplitudes and rates. Nonlinear effects are further quantified using harmonic distortion; however, time series data best illuminate underlying physical processes. The low-frequency stress-strain hysteretic loops show stiffening at the sinusoid's static ends, but stiffening is reduced above a threshold frequency. This shape is determined by harmonic generation in the strain; the stress signal has no harmonics, confirming that the fractured sample is the source of the nonlinearity. These qualitative observations suggest the presence of rate-dependent friction and are consistent between fractures in three different rock types. We propose that static friction at the low strain rate part of the cycle, when given sufficient “healing” time at low oscillation frequencies, causes this stiffening cusp shape in the hysteresis loop. While rate-and-state friction is commonly used to represent dynamic friction, it cannot capture static friction or negative slip velocities. So we implement another dynamic friction model, based on the work of Dahl, which describes this process and produces similar results. Since the two models have a similar form, parameterizations of field data could constraint fault model inputs, such as specific location velocity strengthening or weakening properties.

58 GEOSCIENCES↗

3D characterization of a Great Basin geothermal system: Astor Pass, NV

The Great Basin exhibits both anomalously high heat flow (~75±5 mWm-2) and active faulting and extension resulting in robust geothermal activity. There are ~430 known geothermal systems in the Great Basin, with evidence suggesting that undiscovered blind geothermal systems may actually represent the majority of geothermal activity. These systems employ discrete fault intersection/interaction areas as conduits for geothermal circulation. Recent studies show that steeply dipping normal faults with step-overs, fault intersections, accommodation zones, horse-tailing fault terminations and transtensional pull-aparts are the most prominent structural controls of Great Basin geothermal systems. These fault geometries produce sub-vertical zones of high fault and fracture density that act as fluid flow conduits. Structurally controlled fluid flow conduits are further enhanced when critically stressed with respect to the ambient stress conditions. The Astor Pass blind geothermal system, northwestern Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Along this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range. As such, the Astor Pass area lies in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and more northerly striking normal faults. The Astor Pass tufa tower implies the presence of a blind geothermal system. Previous studies suggest that deposition of the Astor Pass tufa was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal fault. Subsequent drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming the presence of a blind geothermal system at Astor Pass. Expanding upon previous work and employing additional detailed geologic mapping, interpretation of 2D seismic reflection data and analysis of well cuttings, a 3-dimensional geologic model of the Astor Pass blind geothermal system was constructed. The 3D structural framework indicates that the Pleistocene tufa is associated with three discrete fault zones whose intersections plunge moderately to steeply NW-NNW. These critically stressed fault intersections act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

Towards a machine learning framework for acquiring and exploiting monitoring and diagnostic knowledge

In this paper we address the problem of detecting and diagnosing faults in physical systems, for which neither prior expertise for the task nor suitable system models are available. We propose an architecture that integrates the on-line acquisition and exploitation of monitoring and diagnostic knowledge. The focus of the paper is on the component of the architecture that discovers classes of behaviors with similar characteristics by observing a system in operation. We investigate a characterization of behaviors based on best fitting approximation models. An experimental prototype has been implemented to test it. We present preliminary results in diagnosing faults of the Reaction Control System of the Space Shuttle. The merits and limitations of the approach are identified and directions for future work are set.

Manganaris, Stefanos↗

Assessment of the Geomechanical Risks Associated with CO 2 Injection at the FutureGen 2.0 Site: Application of the State of Stress Assessment Tool (SOSAT)

This report presents the results of the application of the State of Stress Assessment Tool (SOSAT) on the FutureGen 2.0 data set. SOSAT was developed as part of the National Risk Assessment Partnership (NRAP) project and provides a unique integrated framework for estimating the state of stress probability distribution at a given depth in the subsurface and evaluating the risk of induced shear and tensile failure resulting from the injection of carbon dioxide (CO 2 ). The approach implemented by SOSAT is based on two deterministic and widely used methods of determining the state of stress (i.e., stress polygon and one-dimensional tectonic-elastic approach). These methods have been modified using a probabilistic approach to account for uncertainties in the input parameters. The methodology proposed in SOSAT was demonstrated using the data obtained for the FutureGen 2.0 project located in the Illinois Basin. Although the FutureGen 2.0 project was suspended by the U.S. Department of Energy prior to the start of injection operations, the extensive characterization efforts undertaken at the storage site have yielded a considerable amount of valuable data about this part of the sedimentary basin. The FutureGen 2.0 storage site was designed to accommodate the injection of 1.1 million metric tons of CO 2 per year over a 20-year period. The injection of CO 2 and the associated pressure buildup in the reservoir is expected to alter the state of stress over the course of the injection. These changes in the initial stress state may affect fault stability and potentially lead to the unintentional creation of hydraulic fractures, which could pose a leakage risk if not contained within the reservoir. Assessing these risks is critical to making informed decisions about the characterization, management of the injection operation, and monitoring of the storage site. The data required by SOSAT for the geomechanical assessment of the FutureGen 2.0 site were identified, and the methodology proposed in SOSAT was followed to evaluate the probability of reactivating critically oriented faults or potentially creating hydraulic fractures in the reservoir. The results of the geomechanical analysis performed using the SOSAT led to the following conclusions. 1. The probability distribution of the state of stress indicates significant uncertainties in the magnitude of the maximum horizontal stress S Hmax , while the minimum horizontal stress S hmin is well constrained by the stress measurements conducted during the characterization efforts at the storage site. This uncertainty in the magnitude of S Hmax is a common challenge and has significant implications for geomechanical risk at sites like FutureGen 2.0 where a strike-slip tectonic regime exists. 2. The probability that the Mount Simon reservoir was initially critically stressed is relatively high—25%. When the pore pressure increases to the maximum allowable pressure permitted under the Underground Injection Control Class VI regulation of the FutureGen 2.0 project, the risk of shear failure approaches a probability of 43%. These relatively high probabilities reflect the current state of information about the geomechanical conditions in this part of the Illinois Basin. For future operations in this basin this should be a high characterization priority because it could significantly lower the risk of operations. 3. Based on the maximum injection pressure allowed in the UIC Class VI, the risk of unintentional hydraulic fracturing is limited. The risk of shear failure as determined by SOSAT is based on a very conservative approach assuming that critically oriented faults exist in the subsurface. While no faults have been formally identified at the FutureGen 2.0 site, the results obtained with SOSAT using the FutureGen 2.0 data set highlight the importance of integrating uncertainties in critical parameters to quantify geomechanical risks in a defensible way. Should SOSAT have been available at the time the characterization activities were being planned, more characterization efforts would have been implemented to reduce the uncertainties on the magnitude of the maximum horizontal stress, and to dismiss with confidence the potential existence of a critically-oriented fault in the reservoir (e.g., 3D seismic survey).

54 ENVIRONMENTAL SCIENCES↗

Asperity generation and its relationship to seismicity on a planar fault: A laboratory simulation

Earthquake faults, and all frictional surfaces, establish contact through asperities. A detailed knowledge of how asperities form will enable a better understanding of the manner in which they communicate during foreshock failure sequences that are observed, leading to the larger main shock. We present results of experiments where a pressure sensitive film was used to map, size and measure the magnitudes of the normal stresses at asperities along a seismogenic section of a laboratory simulated fault. We measured seismicity acoustically and foreshocks were found to be the result of localized asperity failure during the nucleation phase of gross fault rupture. Since surface roughness plays an important role in how asperities are formed, two Hurst exponents were measured to characterize a highly worn interface using roughness profiles: (i) long wavelength estimates (H ~ 0.45) and (ii) short wavelength estimates (H ~ 0.8-1.2). The short wavelength roughness estimates were computed at the scale of single asperity junction points. Macroscopically, the number of asperities and real contact area increased with additional application of normal force while the mean normal stress remained constant. The ratio of real to nominal contact area was low - ranging from 0.02 < A r /A 0 < 0.05-predicting that the asperities should be elastically independent of each other. Results from the pressure sensitive film showed that asperities were closely spaced and could not be treated as mechanically independent. Larger asperities carried both higher levels of average normal stress and higher levels of normal stress heterogeneity than smaller ones. Using linear stability theorem, the critical slip distance on foreshocking asperities was estimated to be d 0 ~ 0.65-3 μm. The critical slip distance d 0 was ~1.8-11.5 per cent of the premonitory slip needed to initiate gross fault rupture of the interface (20-40 μm) and the overall slip necessary to initiate gross fault rupture was on the order of the average asperity diameter (52 μm). In conclusion, foreshocks may be due to a change in the critical slip distance, at localized sections of the fault, caused by the two distinct roughness profiles measured at short and long length scales.

58 GEOSCIENCES↗

Geothermal potential of Harrat Rahat, Northern Arabian Shield: geological constraints

Arabian Shield offers a strong potential for geothermal energy. However, only a limited amount of exploration effort has taken place. Harrat Rahat is a recent volcanic area located along the Makkah-Madinah-Nafud volcanic line in western Saudi Arabia. This study is oriented to identify the geothermal potential of Harrat Rahat. The geologic data was collected and processed. Here, we focus on evaluating the potential sources of subsurface heat and groundwater. Subsurface heat is based on the age of erupted volcanoes and the expected volume of subsurface magma chambers. An analogy with an existing geothermal field in a similar setting as Mexico suggests that the faults and the coincident seismicity may be associated with higher permeability. It is concluded that Harrat Rahat is characterized by a good geothermal potential for future geothermal energy source production.

58 GEOSCIENCES↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

24 POWER TRANSMISSION AND DISTRIBUTION↗