Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mixer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Wide-Bandwidth, Low-Noise SIS Receiver Design for Millimeter and Submillimeter Wavelengths

In principle, millimeter and submillimeter heterodyne receivers using state-of-the-art SIS detectors are capable of extremely large instantaneous bandwidths with noise temperatures within a few Kelvin of the quantum limit. We are applying modem design tools, such as 3D electromagnetic simulators and Caltech's SuperMix SIS analysis package, to develop a new generation of waveguide SIS mixers with very broad RF and IF bandwidths. Our initial design consists of a double-sideband mixer targeted for the 180- 300 GHz band that uses a single SIS junction excited by a full bandwidth, fixed-tuned waveguide probe on a silicon substrate. The IF output band, limited by the MMIC low-noise IF preamplifier, is 6-18 GHz, providing an instantaneous RF bandwidth of 24 GHz (double-sideband). The SIS mixer conversion loss is predicted to be no more than 1-2 dB (single-sideband) with mixer noise temperatures across the band within 10 Kelvin of the quantum limit. The single-sideband receiver noise temperature goal is 70 Kelvin. The wide instantaneous bandwidth and low noise will result in an instrument capable of a variety of important astrophysical observations beyond the capabilities of current instruments. Lab testing of the receiver will begin in the summer of 2002, and a demonstration on the CSO should occur in the spring of 2003.

Sumner, Matthew↗

Combined Numerical/Analytical Perturbation Solutions of the Navier-Stokes Equations for Aerodynamic (Ejector Nozzle) Flows

In spite of the rapid advances in both scalar and parallel computational tools, the large number and breadth of variables involved in aerodynamic systems make the use of parabolized or even boundary layer fluid flow models impractical for both preliminary design and inverse design problems. Given this restriction, we have concluded that reduced or approximate models are an important family of tools for design purposes. This study of a combined perturbation/numerical modeling methodology with an application to ejector-mixer nozzles (shown schematically in the following figure) is nearing completion. The work is being funded by a grant from the NASA Lewis Research Center to Texas A&M University. These ejector-mixer nozzle models are designed to be of use to the High Speed Civil Transport Program and may be adopted by both NASA and industry. A computer code incorporating the ejector-mixer models is under development. This code, the Differential Reduced Ejector/Mixer Analysis (DREA), can be run fast enough to be used as a subroutine or to be called by a design optimization routine. Simplified conservation equations--x-momentum, energy, and mass conservation--are used to define the model. Unlike other preliminary design models, DREA requires minimal empirical input and includes vortical mixing and a fully compressible formulation among other features. DREA is being validated by comparing it with results obtained from open literature and proprietary industry data. Preliminary results for a subsonic ejector and a supersonic ejector are shown. In addition, dedicated experiments have been performed at Texas A&M. These experiments use a hydraulic/gas flow analog to provide information about the inviscid mixing interface structure. Final validation and documentation of this work is expected by May of 1997. However, preliminary versions of DREA can be expected in early 1997. In summary, DREA provides a sufficiently detailed and realistic ejector-mixer nozzle model at a computational cost compatible with preliminary design applications.

DeChant, Lawrence J.↗

Computational Fluid Dynamics (CFD) Simulations of Jet Mixing in Tanks of Different Scales

For long-duration in-space storage of cryogenic propellants, an axial jet mixer is one concept for controlling tank pressure and reducing thermal stratification. Extensive ground-test data from the 1960s to the present exist for tank diameters of 10 ft or less. The design of axial jet mixers for tanks on the order of 30 ft diameter, such as those planned for the Ares V Earth Departure Stage (EDS) LH2 tank, will require scaling of available experimental data from much smaller tanks, as well designing for microgravity effects. This study will assess the ability for Computational Fluid Dynamics (CFD) to handle a change of scale of this magnitude by performing simulations of existing ground-based axial jet mixing experiments at two tank sizes differing by a factor of ten. Simulations of several axial jet configurations for an Ares V scale EDS LH2 tank during low Earth orbit (LEO) coast are evaluated and selected results are also presented. Data from jet mixing experiments performed in the 1960s by General Dynamics with water at two tank sizes (1 and 10 ft diameter) are used to evaluate CFD accuracy. Jet nozzle diameters ranged from 0.032 to 0.25 in. for the 1 ft diameter tank experiments and from 0.625 to 0.875 in. for the 10 ft diameter tank experiments. Thermally stratified layers were created in both tanks prior to turning on the jet mixer. Jet mixer efficiency was determined by monitoring the temperatures on thermocouple rakes in the tanks to time when the stratified layer was mixed out. Dye was frequently injected into the stratified tank and its penetration recorded. There were no velocities or turbulence quantities available in the experimental data. A commercially available, time accurate, multi-dimensional CFD code with free surface tracking (FLOW-3D from Flow Science, Inc.) is used for the simulations presented. Comparisons are made between computed temperatures at various axial locations in the tank at different times and those observed experimentally. The affect of various modeling parameters on the agreement obtained are assessed.

Breisacher, Kevin↗

Miniature MMIC Low Mass/Power Radiometer Modules for the 180 GHz GeoSTAR Array

We have developed and demonstrated miniature 180 GHz Monolithic Microwave Integrated Circuit (MMIC) radiometer modules that have low noise temperature, low mass and low power consumption. These modules will enable the Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR) of the Precipitation and All-weather Temperature and Humidity (PATH) Mission for atmospheric temperature and humidity profiling. The GeoSTAR instrument has an array of hundreds of receivers. Technology that was developed included Indium Phosphide (InP) MMIC Low Noise Amplifiers (LNAs) and second harmonic MMIC mixers and I-Q mixers, surface mount Multi-Chip Module (MCM) packages at 180 GHz, and interferometric array at 180 GHz. A complete MMIC chip set for the 180 GHz receiver modules (LNAs and I-Q Second harmonic mixer) was developed. The MMIC LNAs had more than 50% lower noise temperature (NT=300K) than previous state-of-art and MMIC I-Q mixers demonstrated low LO power (3 dBm). Two lots of MMIC wafers were processed with very high DC transconductance of up to 2800 mS/mm for the 35 nm gate length devices. Based on these MMICs a 180 GHz Multichip Module was developed that had a factor of 100 lower mass/volume (16x18x4.5 mm3, 3g) than previous generation 180 GHz receivers.

Monolithic Microwave Integrated Circuit (MMIC)↗

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

Electrostatic Beneficiation of Lunar Simulant

Electrostatic beneficiation of lunar regolith is a method allowing refinement of specific minerals in the material for processing on the moon. The use of tribocharging the regolith prior to separation was investigated on the lunar simulant MLS-I by passing the dust through static mixers constructed from different materials; aluminum, copper, stainless steel, and polytetrafluoroethylene (PTFE). The amount of charge acquired by the simulant was dependent upon the difference in the work function of the dust and the charging material. XPS and SEM were used to characterize the simulant after it was sieved into five size fractions (> 100 pm, 75-100 pm, 50- 75 pm, 50-25 pm, and < 25 pm), where very little difference in surface composition was observed between the sizes. Samples of the smallest (< 25 pm) and largest (> 100 pm) size fractions were beneficiated through a charge separator using the aluminum (charged the simulant negatively) and PTFE (charged positively) mixers. The mass fractions of the separated simulant revealed that for the larger particle size, significant unipolar charging was observed for both mixers, whereas for the smaller particle sizes, more bipolar charging was observed, probably due to the finer simulant adhering to the inside of the mixers shielding the dust from the charging material. Subsequent XPS analysis of the beneficiated fractions showed the larger particle size fraction having some species differentiation, but very little difference for the smaller.size. Although MLS-1 was made to have similar chemistry to actual lunar dust, its mineralogy is quite different. On-going experiments are using NASA JSC-1 lunar simulant. A vacuum chamber has been constructed, and future experiments are planned in a simulated lunar environment.

Trigwell, Steve↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction, supersonic, jet noise↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction↗

Wideband fixed-tuned SIS receiver for 200-GHz operation

We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.

RECEIVER NOISE TEMPERATURE↗

RF spectrometers for heterodyne receivers

Several types of spectrometers developed for radio astronomy receivers which utilize RF filters, multiple oscillators and mixers, digital autocorrelators and acoustic/optic devices are considered. The RF spectrometer developed at GSFC to provide wide bandwidths (greater than 1 GHz) as well as high resolution (5MHz) is described. The 128 channel filter bank is divided into high and low resolution sections. The high resolution section is tunable by providing a second mixer ahead of the filter bank. This is necessary because infrared receivers which use gas lasers as local oscillators are only tunable to specific laser frequencies. To compensate for astronomical Doppler shifts and molecule frequency differences a second local oscillator and mixer is needed. A diagram of the RF section of the filter bank is shown. The RF spectrometer is shown to be the best means of achieving ultra-wide bandwidths for infrared heterodyne receivers. For high resolution with a large number of channels, the acousto/optical spectrometer is the principle instrument, particularly for balloon or space flight applications.

Buhl, D.↗

Sub mm laser local oscillators: Design criteria and results

Diagnostic results are given of the spectral features and the power conversion efficiency of submillimeter (SMM) laser local oscillators. Several criteria are obtained for the design of frequency stable and efficient smm lasers for local oscillator applications. Finally, a design is described and results on the power output and power and frequency stability are given. The mode pattern is very close to a Gaussian profile so that efficient coupling to a quasioptical mixer is possible. The laser provides sufficient output power at a large number of lines to drive the mixer into the low conversion loss regime. Radiometric integration times of several minutes with a spectral resolution of 1 MHz will be possible. With present state-of-the-art Schottky mixers and low noise preamplifiers a radiometric temperature resolution of a few K can be expected over a spectral range from 500to 900 GHz.

Koepf, G. A.↗

Pulsed phase locked loop strain monitor

The RF output of a voltage controlled oscillator (VCO) is periodically gated to a transducer which produces acoustic waves in a bolt. The reflected acoustic waves are converted to electrical signals by the transducer and gated to a mixer which also receives the output from the VCO and produces an output which is filtered by a low pass filter. The output of filter is a dc signal proportional to the phase difference change from a fixed phase difference between the two input signals to the mixer. This dc signal is sampled at an instant and held by circuit in response to the "P" signal. The output of the circuit is integrated and then applied to the VCO to change the frequency of the VCO such that the phase difference between the two inputs to the mixer remains at the fixed phase difference. The frequency of the VCO is a measure of the change in strain of the bolt.

Heyman, J. S.↗

High stability buffered phase comparator

A low noise RF signal phase comparator comprised of two high stability driver buffer amplifiers driving a double balanced mixer which operate to generate a beat frequency between the two RF input signals coupled to the amplifiers from the RF sources is described. The beat frequency output from the mixer is applied to a low noise zero crossing detector which is the phase difference between the two RF inputs. Temperature stability is provided by mounting the amplifiers and mixer on a common circuit board with the active circuit elements located on one side of a circuit board and the passive circuit elements located on the opposite side. A common heat sink is located adjacent the circuit board. The active circuit elements are embedded into the bores of the heat sink which slows the effect of ambient temperature changes and reduces the temperature gradients between the active circuit elements, thus improving the cancellation of temperature effects. The two amplifiers include individual voltage regulators, which increases RF isolation.

Adams, W. A.↗

EHF low-noise FET receiver

Extremely high frequency (EHF) receivers for military and NASA programs must be small, lightweight, and highly reliable. In connection with recent advances in the development of mm-wave FET devices and circuits, a basis has been obtained for the eventual replacement of diode mixer front-ends by FET preamplifiers in receivers up to 94 GHz. By placing a low noise amplifier in front of the mixer it is possible to achieve a lower system noise figure than that found in conventional mm-wave receivers. A broader bandwidth can also be provided. Attention is given to the receiver configuration, a low noise FET amplifier, an image rejection filter, a dual-gate FET mixer, a FET local oscillator, and a FET receiver.

Schellenberg, J. M.↗

A superconducting tunnel junction receiver for millimeter-wave astronomy

The development and construction of an ultralow noise heterodyne receiver for millimeter wave astronomy is described along with its use for 115.3 GHz Co line observations. The receiver uses a Superconductor-Insulator-Superconductor (SIS) quasiparticle tunnel junction mixer to convert the millimeter wave signal to a microwave intermediate frequency. Experiments aimed at quantitative verification of J. R. Tucker's quantum mixer theory are studied, to see whether it could be used as the basis for the design of a practical receiver. The experimental results were in excellent agreement with the theory, assuming the three frequency approximation. Infinite available gain and negative output resistance were observed for the first time, nonclassical effects which are not seen in conventional diode mixers. Using Tucker's theory, an SIS receiver was then designed and constructed. At 115 GHz, the single sideband receiver noise temperature is 83K, the lowest ever reported in this frequency range. A CO survey toward Cygnus-X region, using this SIS receiver on the Columbia-GISS 4 ft. telescope, is also described.

Pan, S. K.↗

The U.C. Berkeley Space Sciences Laboratory and Department of Physics Submillimeter Receiver

The UCB submm heterodyne receiver is a complete system for high-resolution astronomical spectroscopy in the 350-micron and 450-micron atmospheric windows. This compact system mounts directly at the Cassegrain focus of large optical and IR telescopes. It consists of a laser local oscillator, open structure mixer, quasi-optical coupling system, a broad-band IF system, and an acoustooptical spectrometer. The local oscillator is a 1-m-long submm laser optically pumped by a CO2 laser. The mixer is a quasi-optical corner-cube antenna structure and Schottky diode. The mixer is currently operated at room temperature, and its performance at 77 K is being evaluated. The system noise temperature is less than 7000 K SSB during observations.

Harris, A. I.↗

Submillimeter heterodyne receiver for the CSO telescope

This task is to build a cryogenically cooled 620 to 700 GHz astronomical receiver that will be used as a facility instrument at the CalTech Submillimeter Observatory (CSO) on Mauna Kea, Hawaii. The receiver will have applications as a very high resolution spectrometer to investigate spectral lines in planetary and satellite atmospheres, and comets. The receiver will also be used to make continuum measurements of planets, satellites, and asteroids. During FY88, a scale model (200 GHz) SIS mixer radiometer was built and intrgrated into a cryostat designed for use on the CSO telescope. This system will serve as a model to guide the work on the higher frequency mixer. A solid state local oscillator source that covers two bands in the 600 to 700 GHz has been developed under contract JPL and will be delivered before the end of the year. Work has continued on the SIS materials needed for the 620 to 700 GHz mixer. Test hardware has been developed which allow the 1 to 5 curves for SIS material to be easily measured.

Gulkis, S.↗