Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Radiation Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life measurement of the 199-keV isomeric state in Ga 76

Background: Isomeric states in atomic nuclei are a sensitive probe of their underlying microscopic structure and can be used to study the evolution of shell structure far from stability. Recent studies have identified and provided detailed spectroscopy of isomers in neutron-rich nuclei with Z = 28-50. Isomeric states in the odd-odd gallium isotopes have been reported for all gallium isotopes from A = 72 to A = 80 with the exception of 76 Ga. Purpose: The purpose of this experiment was to observe short-lived isomeric states in the vicinity of 78 Ni. Methods: In-beam fragmentation of a 86 Kr primary beam at the National Superconducting Cyclotron Laboratory produced radioactive ions which were delivered to and deposited in a Ce Br 3 scintillator coupled to a position-sensitive photomultiplier tube. Beta-delayed γ rays were measured by ancillary HPGe clover and LaBr 3 detectors which surrounded the implantation detector. Results: The previously observed J π = 1 + , 199-keV level in 76 Ga, populated following the β decay of 76 Zn, was identified as isomeric with a half-life of 34(1) stat. (8) sys. ns. Shell-model calculations suggest this state is formed by the coupling of protons in negative-parity configurations to 1/2 - neutron configurations. Transition strengths assuming a ground-state spin of J = 2 and J = 3 were determined from the experimental data.

59 ≤ A ≤ 89↗

Total kinetic energy release in the fast neutron induced fission of actinide nuclei

The total kinetic energy release and fission mass distributions for the fast neutron (En = 3–100 MeV) induced fission of 232 Th, 233 U, 235 U, 237 Np, 239 Pu, 240 Pu, and 242 Pu have been measured using the LANSCE facility. The neutron energies were deduced from time-of- flight measurements. The fission fragments were detected using Si PIN diode detectors, giving us the fragment energies. The actinide targets were made by vapor deposition leading to high-quality targets, that were thin and uniform with reduced impurities. Corrections were made to the data for pulse height defect and the fragment energy loss in the target and its backing. The TKE distributions were Gaussian in shape and their mean value as a function of incoming neutron energy could be fitted with second order polynomials. In the case of 233 U and 235 U, our measurements agree with prior work. Our measurements for 232 Th are unique. Our data agree with Viola scaling. The constant position of the heavy mass peak is interpreted as being due to the influence of the N = 88 and Z = 50 shells. The GEF model predictions agree with the data in general as do the CGMF model predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision pulse shape simulation for proton detection at the Nab experiment

The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron β decay to an anticipated precision of approximately 0.1%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. In conclusion, we present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray signatures of 𝑟-process radioactivity from the collapse of magnetized white dwarfs

We predict the gamma-ray line emission from 𝑟-process nuclei synthesized in the ejecta of the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf. Using ejecta from a two-dimensional general-relativistic neutrino-magnetohydrodynamic simulation, further evolved with a radiation-hydrodynamics code coupled to an in situ nuclear reaction network, we construct angle-dependent gamma-ray spectra in the 0.01–10 MeV band via composition-dependent ray tracing through the ejecta. The emission between ∼1 and 10 d is dominated by 132 I (𝑡 1/2 = 2.3 h), continuously replenished by the decay of its parent 132 Te (𝑡 1/2 = 3.2 d), with additional contributions from 131 I, 133 Xe, and 132 Te . At 𝑡 ≳ 20 d, 56 Co (from 56 Ni decay) becomes the primary emitter. The simultaneous presence of 𝑟 process and iron-peak gamma-ray lines is distinctive of AIC ejecta and absent in binary neutron star mergers, where iron-peak nuclei are generally not synthesized. Comparing with the 3⁢𝜎 continuum sensitivities of planned MeV gamma-ray telescopes (COSI, AMEGO-X, e-ASTROGAM, GRAMS, GammaTPC), we find the brightest 𝑟-process lines detectable to ∼10 Mpc by GammaTPC and GRAMS, with the signal approaching their sensitivity threshold at 30 Mpc. As a result, the 𝑟-process spectral features survive time integration over ∼30 d exposures, demonstrating robustness against the long observation times required by gamma-ray detectors.

Nuclear reactions↗

Shedding light on the 239Pu fission source term with new high-precision experiments and advanced fission modeling

In the last decade, there has been a renaissance of fission research resulting in new high-precision experiments and advanced fission modeling. For instance, the Chi-Nu and CEA teams supplied, for the first time, the 239 Pu prompt fission neutron spectrum (PFNS) for broad ranges of incident and outgoing neutron energies. The CEA team also measured 239 Pu average prompt neutron multiplicities, ν ̄ p , with lower statistical uncertainties and a technique significantly different than the one used in the past. The NIFFTE collaboration provided 239 Pu( n ,f)/ 235 U( n ,f) cross section shape ratios with uncertainties below 1% utilizing a novel detector type. Advanced fission event generators were developed, among them CGMF, FIFRELIN, FREYA, and GEF, which calculate post-scission fission observables in a correlated manner. These new experimental data and more consistent fission models change the evaluated PFNS, ν ̄ p , and ( n ,f) cross sections, some only modestly, compared to ENDF/B-VIII.0. In turn, the individual new nuclear data distinctly change simulated effective neutron multiplication factors of fast critical assemblies, but their combined impact is small, while affecting the prediction of LLNL pulsed sphere neutron leakage spectra and reaction rates only within experimental uncertainties. Also, the parameters obtained from fitting to ν ̄ p reproduce various post-scission fission observables within the uncertainties of experimental data. This indicates that new differential experiments and consistent fission modeling reduce compensating errors present in ENDF/B-VIII.0.

fission cross section↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of MCNP Training Modules for Safeguards Practitioners [Abstract]

The Monte-Carlo N-Particle (MCNP) software developed at LANL is the most widely used neutron transport code in the world. It is an essential tool for a variety of applications including detector development and design, nuclear fuel burnup simulation, criticality safety, and nondestructive assay system optimization. For this reason, it is indispensable within the safeguards and materials control & accountability (MC&A) communities. Multiple MCNP training courses have been created and taught over the last several decades by the MCNP development team at LANL, however there are no existing courses that cover specialized topics considered fundamental to NDA and safeguards models. To fill this gap, the MCNP team and Safeguards Science and Technology group at LANL have co-created a set of training modules customized to meet the specialized needs of the safeguards and MC&A communities. The basic modules cover concepts such as NDA system optimization, He-specific and other capture tallies, and tools for improved theoretical understanding. An advanced module was also created to cover topics including variance reduction for active interrogation simulations, use of the LANL MCNPTools post-processor, PTRAC (particle tracking) and list-mode data simulations, and fuel burnup simulations. The training modules teach to the latest and most state-of-the-art MCNP features and tools released by the development team at LANL and are intended to be taught jointly by the developers and safeguards experts. Ultimately, we hope that creation of these modules will serve to capture and convey the safeguards modeling and MCNP expertise at LANL, and that we will be able to share the modules more broadly with the MC&A and safeguards communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decay studies of the 𝛽-delayed neutron emitters 87 Br and 88 Br measured by means of the Modular Total Absorption Spectrometer at ORNL HRIBF

The β decays of 87 Br, 88 Br, and 87 Kr were measured with the Modular Total Absorption Spectrometer (MTAS) at Oak Ridge National Laboratory’s Holifield Radioactive Ion Beam Facility (HRIBF). Both bromine isotopes are β-delayed neutron emitters that have large cumulative fission yields and were identified as top-priority cases for total absorption study by the Nuclear Energy Agency in 2007. Our investigations corroborate that the decay schemes of 87 Br and 88 Br suffer from the so-called pandemonium effect. Unique MTAS properties enable direct neutron measurements. Here, we present MTAS-derived β-delayed neutron spectra, β-delayed neutron emission probabilities of P n ( 87 Br) = 2.36(24)%, and P n ( 88 Br) = 6.4(6)%, and the β-delayed neutron transitions intensity of 4(2)% to the first excited 87 Kr state, populated in the β-neutron decay of 88Br. Incorporating new data into calculations of the electromagnetic decay heat component emitted during thermal neutron fission of 235 U and 239 Pu improves agreement with experimental data up to approximately 80 s after fission. The estimation of the nuclear reactor $\bar{ν}_e$ flux results in changes of up to 1% in the expected $\bar{ν}_e$ interactions with the detector material for 235 U, 238 U, 239Pu, and 241 Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments with neutron induced neutron emission from U-235, Pu-239, and graphite

A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Innovative dead-time correction and background subtraction for neutron multiplicity measurements using neural networks

Abstract The number of neutrons emitted from a nuclear reaction plays a crucial role in various fields, including nuclear theory, nuclear nonproliferation, nuclear energy and nuclear criticality safety. Accurate determination of neutron multiplicities requires the application of several corrections, with dead-time correction and background subtraction being particularly significant. These corrections become more challenging for neutron detectors with time-dependent neutron capture. In this work, we perform a comprehensive study of three existing methods used for dead-time correction and background subtraction in neutron detectors with time-dependent neutron capture. The methods were tested for dead-times in the range from 0 to 1 μs using a Monte Carlo model simulating the dead-time and background effects in the standard neutron multiplicity probability distribution of $$^{252}$$ 252 Cf. The previous methods showed larger than desired uncertainty or systematic trade off. Those uncertainties prompted the development of a novel approach using neural networks trained with data from Monte Carlo simulations. The Neural Network method enabled the correction of neutron multiplicity probabilities more accurately than the other methods with fractional errors smaller than 3% for multiplicities around the peak of $$^{252}$$ 252 Cf. A similar approach using neural networks could be applied to problems where the system being studied can be accurately simulated without having an accurate analytical description available. The neural network method presented in this paper can be easily expanded if multiplicities greater than 10 are expected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Data Sheets for A=64

The evaluated experimental data are presented and evaluated for 13 known nuclides of mass 64 (Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se). For each nuclide, the best values combining all available data are recommended for spectroscopic properties. No excited states have been identified in 64 Ti, 64 As, and 64 Se. Only one excited state in 64 V as an isomer, and three in 64 Cr have been identified. Data for excited states in 64 Mn, 64 Fe, and 64 Co remain limited. 64 Ni, 64 Cu, and 64 Zn are the most studied nuclides through various reactions and decays, followed by 64 Ga and 64 Ge. In the opinion of the evaluators, there are several incomplete or discrepant aspects of the high-spin portion of the level scheme for 64 Zn above ≈5 MeV excitation which need to be resolved in further experiments using large γ-detector arrays. The decay schemes of 64 Ti β - , 64 As ε and 64 Se ε are unknown, while very little information is available for 64 V β - and 64 Cr β - . The decay schemes of 64 Mn β - , 64 Fe β - , 64 Co β - and 64Ge ε are somewhat better known, but still considered incomplete by evaluators. The decay scheme of 64 Ga ε decay is known in detail, however there is the possibility of additional levels populated above 4713 keV, as the Q(ε) value is 7171 keV. The β - , β + and ε decay modes of 64 Cu are well known, as this radionuclide is of great importance in applications, for example, as a dosimeter for neutron flux determination in nuclear reactors, and as a radiopharmaceutical for positron emission tomography (PET). This work supersedes earlier full evaluations of A=64 by 2007Si04, 1996Si12, 1991Si03, 1979Ha35 and 1974Au04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Levels in 125 Cd populated by the β decay of 125 m Ag and 125 Ag

Here, the β decay of 125 m, 125 Ag into levels in 125 Cd was investigated at the Holifield Radioactive Ion Beam Facility (HRIBF). Uranium-238 targets were bombarded with 50-MeV protons with an intensity of 15 μ A, and the induced fission products were mass separated and deposited on a moving tape in the center of the VANDLE array consisting of γ detectors and plastic scintillators. A partial decay scheme has been assigned for both β decay of the (9/2 + ) ground state of 125 Ag and its low-lying (1/2 - ) isomer, with the energy of the low-lying (11/2 - ) isomeric state in 125 Cd assigned as 188.5 keV. In addition, β -delayed neutron emission probabilities were also determined to be 1.2(2)% for the (9/2 + ) 125 Ag ground state and 4.6(10)% for the (1/2 - ) isomer, which are substantially lower than the previously reported value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Interrogation of the Snyder Shells using a SEA-7 Betatron

The shielded highly enriched uranium (HEU) problem is one that still needs to be addressed. As a first step towards a solution, the Snyder shells (depleted uranium) were actively interrogated with a SEA-7 betatron in various configurations using an MC15 as a detector. These configurations include masses from 0.55 to 5.1 kg, as well as 5.1 kg in a steel container. A strong electromagnetic field (EMF) background was identified in previous work, but the results in this work show all configurations produce a signal well above the background. An initial simulation capability was developed that produces the expected flux profile from the SEA-7 betatron, but further work needs to be done to determine the magnitude of the flux via a combination of experiment and simulation validation. Depleted uranium generally produces more neutrons than HEU, so additional future work will need to include similar measurements of HEU to confirm similar performance of the technique. Additionally the EMF background needs to be better characterized as a function of distance and angle from the SEA-7 source and mitigation techniques explored.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗