Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WE-D-17A-05: Measurement of Stray Radiation Within An Active Scanning Proton Therapy Facility: EURADOS WG9 Intercomparison Exercise of Active Dosimetry Systems

Purpose: Intercomparison of active dosemeters in the measurement of stray radiation at the Trento active-scanning proton therapy facility. Methods: EURADOS WG9 carried out a large intercomparison exercise to test different dosemeters while measuring secondary neutrons within a 230 MeV scanned proton therapy facility. Detectors included two Bonner Sphere Spectrometers (BSS), three tissue equivalent proportional counters (TEPCHawk) and six rem-counters (Wendi II, Berthold, RadEye, a regular and an extended-range Anderson and Braun NM2B counters). Measurements of neutron ambient dose equivalents, H*(10), were done at several positions inside (8 positions) and outside (3 positions) the treatment room while irradiating a water tank phantom with a 10 × 10 × 10 cc field. Results: A generally good agreement on H*(10) values was observed for the tested detectors. At distance of 2.25 m and angles 45°, 90° and 180° with respect to the beam axis, BSS and proportional counters agreed within 30%. Higher differences (up to 60%) were observed at the closest and farthest distances, i.e. at positions where detectors sensitivity, energy, fluence and angular response are highly dependent on neutron spectra (flux and energy). The highest neutron H*(10) value, ∼60 microSv/Gy, was measured at 1.15 m along the beam axis. H*(10) decreased significantly with the distance from the isocenter dropping to 1.1 microSv/Gy at 4.25 m and 90° from beam axis, ∼2 nanoSv/Gy at the entrance of the maze, 0.2 nanoSv/Gy at the door outside the room and below detection limit in the gantry control room and at an adjacent room. These values remain considerately lower than those of passively scattered proton beams. BSS and Hawk unfolded spectra provide valuable inputs when studying the response of each detector. Conclusion: TEPCs and BSS enable accurate measurements of stray neutrons while other rem-meters also give satisfactory results but require further improvements to reduce uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron counter based on beryllium activation

The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron cyclotron resonance 140 mA D{sup +} beam extraction optimization for IFMIF EVEDA accelerator

Based on the experience of the SILHI electron cyclotron resonance (ECR) ion source for the IPHI accelerator, which produces routinely 100-120 mA H{sup +} beam, the CEA-Saclay is in charge of the design and realization of the 140 mA cw deuteron source for the IFMIF project (International Fusion Materials Irradiation Facility). IFMIF is an accelerator-based neutron irradiation facility consisting of two accelerators of 125 mA D{sup +} beam at 40 MeV that hit in parallel a lithium target. IFMIF utilizes the deuteron-lithium (d-Li) neutron, producing a reaction to simulate the 14 MeV neutron environment in deuterium-tritium (D-T) fusion reactors. In the framework of the IFMIF EVEDA phase (Engineering Validation and Engineering Design Activities), we are studying a cw ECR ion source with a new extraction system to allow high current extraction while keeping a low divergence as well as a small emittance. Starting from SILHI five-electrode system with H{sup +} ions, the extracted beam characteristics as well as electric field conditions are compared with the cases of four- and three-electrode extraction systems. Experimental results made on the SILHI source with H{sup +} ions are briefly discussed. Extensive experimental results on the new source test bench BETSI are expected as soon as the design and fabrication of a dedicated extraction system with a new set of electrodes will be finished.

36 MATERIALS SCIENCE↗

Low Background Counting at LBNL

The Low Background Facility (LBF) at Lawrence Berkeley National Laboratory in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background cave and remotely at an underground location that historically has operated underground in Oroville, CA, but has recently been relocated to the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products, as well as active screening via Neutron Activation Analysis for specific applications. The LBF also provides hosting services for general R&D testing in low background environments on the surface or underground for background testing of detector systems or similar prototyping. A general overview of the facilities, services, and sensitivities is presented. Recent activities and upgrades will also be presented, such as the completion of a 3π anticoincidence shield at the surface station and environmental monitoring of Fukushima fallout. The LBF is open to any users for counting services or collaboration on a wide variety of experiments and projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The PANDA physics program: Strangeness and more

The physics program of the PANDA experiment at FAIR is illustrated, with a particular attention to the planned activity in the field of the doubly strange systems. The investigation of these systems can help, among others, to shed light on the role of the hyperons in the composition of the neutron stars. The great advantages that can be reached in the field of the charmed systems and nucleon structure by using high quality and intense antiproton beams are also recalled.

79 ASTRONOMY AND ASTROPHYSICS↗

Continued Research for Improvement of PROTEUS-SN

Over the past several years, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program of U.S. DOE has focused on developing a neutronics component as part of a larger dynamics product meant to analyze both existing and proposed nuclear reactor systems. The goal is to reduce the uncertainties and biases in reactor design activities by providing enhanced prediction capabilities. As part of the SHARP program, we have invested considerable effort into creating the PROTEUS-SN code. The PROTEUS-SN solver was intended to treat conventional homogenized assembly to explicit geometry schemes for time dependent analysis with coupled thermal-hydraulics and structural mechanics.

Smith, M. A.↗

Radiochemistry as a (rho)R Diagnostic with the RAGS Gas Collection System

Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-section measurement of the {sup 18}F({alpha},p){sup 21}Ne reaction and possible implication for neutron production in explosive helium burning

At the high temperature and density conditions of hot or explosive helium burning, the {sup 18}F({alpha},p){sup 21}Ne reaction may compete successfully with the {sup 18}F({beta}{sup +}{nu}) decay. This suggests {sup 21}Ne({alpha},n) as an alternative neutron source in the r-process. We have determined the total cross section of the {sup 18}F({alpha},p){sup 21}Ne reaction by studying the time-reverse reaction {sup 21}Ne(p,{alpha}){sup 18}F. Using the activation technique, the total reaction yield was measured in the proton beam energy range of 2.3-4.0 MeV, which corresponds to energies of 0.5-2.1 MeV in the {sup 18}F+{alpha} system. The resulting yield curve was analyzed in terms of the thick target formalism and the R-matrix theory. The reaction rate was deduced experimentally for the first time for the temperature of 0.1<T{sub 9}<1. The experimental reaction rate was compared with Hauser-Feshbach predictions. The astrophysical implications of the new rate are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗

Simulation of the Nondestructive Assay of 237 Np Using Active Neutron Multiplicity Counting

In this work, the epithermal neutron multiplicity counter (ENMC) and an organic scintillator mul- tiplicity counter (OSMC) are compared in the assay of 237 Np, a potentially weapons-usable isotope, using active neutron multiplicity counting. In active neutron multiplicity counting, the neutron doubles and triples multiplicity rates are used to analytically calculate sample mass. To distinguish the masses of two different samples, the measured triples and doubles rates of each sample must be separated by one standard deviation. Here, the time it takes each system to separate the measured triples multiplicity rates was compared using 20 metal samples of 237 Np with masses logarithmi- cally distributed between 10 and 1000 g. The results show that the OSMC can distinguish the smallest masses (10.0 and 12.7 g) beyond one standard deviation in 20 minutes, and the ENMC requires more than 400 times the measurement time to obtain the same precision. Similarly, the OSMC is at least 4.5 times faster than the ENMC in separating the doubles multiplicity rates.

42 ENGINEERING↗

Chemical fractionation in the solar system

The cosmochemical and geochemical history of planetary material is reflected in relative and absolute abundances of two groups of trace elements; siderophiles and volatiles. Many of these elements can be determined at the required levels only by radiochemical neutron activation analysis. The abundance patterns of elements in chondritic meteorites result from condensation processes in the solar nebula. The composition of planetisimals which bombarded the moon is characterized from trace elements in lunar breccias, and is also related to nebula processes. Trace elements in anorthosites and basalts from earth and moon suggest that the moon is refractory-rich and volatile-poor relative to the earth.

Morgan, J. W.↗

Angular Correlation Date Measurements with the GeRMAC system

Advanced modeling and simulation efforts have improved at Idaho National Laboratory in recent years with a solid foundation of experimental results. Current computational methods represent significant modeling capabilities but are limited by the accuracy and availability of nuclear data. The creation of pre- and post-processing software tools to address these limitations is fundamental to the improvement of nuclear science modeling capacities. One aspect of predictive modeling tools deals with gamma-rays emitted from radionuclides, including fissile or fissionable material, fission products, or activation products, produced in reactor experiments or other neutron environments. The resulting radionuclides decay in unique ways, providing complications upon measurement as a result of random and cascade, or true, coincidence summing. These effects are not easily quantified during modeling efforts of gamma-ray source terms., The germanium rotational measurements for angular correlation (GeRMAC) system was built to quantify the relative angles for gamma rays emitted by radionuclides of interest to investigate true coincidence, or cascade, summing as well as the nuclear energy levels of decay schemes of interest. Proof of concept studies utilize a series of laboratory check sources to provide validity, and it will soon be used to perform the same measurements for fission products of interest. The resulting data can be used to implement into a Monte Carlo code, such as Geant4, to provide more precise gamma-ray source terms following irradiations of materials.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sustaining knowledge in the neutron generator community and benchmarking study. Phase II.

This report documents the second phase of work under the Sustainable Knowledge Management (SKM) project for the Neutron Generator organization at Sandia National Laboratories. Previous work under this project is documented in SAND2008-1777, Sustaining Knowledge in the Neutron Generator Community and Benchmarking Study. Knowledge management (KM) systems are necessary to preserve critical knowledge within organizations. A successful KM program should focus on people and the process for sharing, capturing, and applying knowledge. The Neutron Generator organization is developing KM systems to ensure knowledge is not lost. A benchmarking study involving site visits to outside industry plus additional resource research was conducted during this phase of the SKM project. The findings presented in this report are recommendations for making an SKM program successful. The recommendations are activities that promote sharing, capturing, and applying knowledge. The benchmarking effort, including the site visits to Toyota and Halliburton, provided valuable information on how the SEA KM team could incorporate a KM solution for not just the neutron generators (NG) community but the entire laboratory. The laboratory needs a KM program that allows members of the workforce to access, share, analyze, manage, and apply knowledge. KM activities, such as communities of practice (COP) and sharing best practices, provide a solution towards creating an enabling environment for KM. As more and more people leave organizations through retirement and job transfer, the need to preserve knowledge is essential. Creating an environment for the effective use of knowledge is vital to achieving the laboratory's mission.

07 ISOTOPE AND RADIATION SOURCES↗

Self-diffusion and microscopic dynamics in a gold-silicon liquid investigated with quasielastic neutron scattering

We use incoherent quasielastic neutron scattering to study the atomic dynamics of gold in a eutectic Au{sub 81}Si{sub 19} melt. Despite the glass-forming nature of this system, the gold self-diffusivity displays an Arrhenius behavior with a low activation energy characteristic of simple liquids. At high temperatures, long-range transport of gold atoms is well described by hydrodynamic theory with a simple exponential decay of the self-correlation function. On cooling towards the melting temperature, structural relaxation crosses over to a highly stretched exponential behavior. This suggests the onset of a heterogeneous dynamics, even in the equilibrium melt, and is indicative of a very fragile liquid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗