Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLID STATE LASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A compact and low power coherent optical system for on-board spacecraft data processing.

Discussion of the design and performance of a compact low-power coherent optical data processing system suitable for spacecraft onboard applications. The system is a modification of the conventional optical data processing system in which a much more efficient solid state GaAs laser is substituted for the bulky and inferior He-Ne laser and paraboloidal mirror segments are substituted for the axially symmetric optical system of the conventional data processing system. Theoretical considerations are given to substantiate the improvement of performance aimed at in the modified system. Preliminary tests of the modified design being in progress indicate that a low power, rugged, small size optical system, capable of onboard spacecraft data processing, can be constructed by using off-axis paraboloidal mirror segments.-

Husain-Abidi, A. S.↗

Measurements of the effect of horizontal variability of atmospheric backscatter on dial measurements

The horizontal variability of atmospheric backscatter may have a substantial effect on how Differential Absorption Lidar (DIAL) data must be taken and analyzed. To minimize errors, lidar pulse pairs are taken with time separations which are short compared to the time scales associated with variations in atmospheric backscatter. To assess the atmospheric variability for time scales which are long compared to the lidar pulse repetition rate, the variance of the lidar return signal in a given channel can be computed. The variances of the on-line, off-line, and ration of the on-line to off-line signals at given altitudes obtained with the dual solid-state Alexandrite laser system were calculated. These evaluations were made for both down-looking aircraft and up-looking ground-based lidar data. Data were taken with 200 microsecond separation between on-line and off-line laser pulses, 30 m altitude resolution, 5 Hz repetition rate, and the signal were normalized for outgoing laser energy.

Schwemmer, G. K.↗

Spectroscopic investigation of the Cr to Tm energy transfer in Yttrium Aluminum Garnet (YAG) crystals

New and interesting schemes have recently been considered for the efficient operation of solid-state ionic laser systems. Often the available data on these systems were obtained only because they seemed directly related to the laser performance and provide no insight into the physical processes. A more systematic approach is desirable, where more attention is devoted to the elementary basic processes and to the nature of the mechanisms at work. It is with this aim that we have undertaken the present study. Yttrium Aluminum Garnet (Y4Al5O12), called YAG, has two desirable properties as host for rare earth impurities: (1) trivalent rare earth ions can replace the yttrium without any charge compensation problem, and (2) YAG crystals have high cutoff energies. The results of measurements and calculations indicate that the Cr(3+) ion in YAG can be used to sensitize efficiently the Tm(3+) ion.

Dibartolo, B.↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

1047 nm laser diode master oscillator Nd:YLF power amplifier laser system

A master oscillator power amplifier (MOPA) laser transmitter system at 1047 nm wavelength using a semiconductor laser diode and a diode pumped solid state (Nd:YLF) laser (DPSSL) amplifier is described. A small signal gain of 23 dB, a near diffraction limited beam, 1 Gbit/s modulation rates and greater than 0.6 W average power are achieved. This MOPA laser has the advantage of amplifying the modulation signal from the laser diode master oscillator (MO) with no signal degradation.

Yu, A. W.↗

Wake vortex detection at Denver Stapleton Airport with a pulsed 2-micron coherent lidar

This report describes the effort undertaken to relate aircraft wake history to the local environment. This involved the monitoring of the embedded windfield, monitoring of local meteorological parameters, a high-resolution velocity field analysis in vertical scan planes and measurement of the axial velocity signature. A flashlight pumped 2.09 micron solid state coherent laser radar system was used to detect and track wake vortices. Strong wake vortex signatures were measured for moderate to large aircraft at Denver's Stapleton airport and a large vortex database was compiled.

Hannon, Stephen M.↗

Non-intrusive measurements in a rocket engine combustor

In recent years analytical tools to characterize combustor flow have been developed in order to support design. To facilitate anchoring of combustion related physical models and the CFD codes in which they are incorporated, considerable development and application of non-intrusive combustion diagnostic capabilities has occurred. Raman spectroscopy can be used to simultaneously detect all polyatomic molecules present in significant concentrations and to determine gas temperature. This is because all molecules possess a distinct temperature dependent Raman spectrum. A multi-point diagnostic system for non-intrusive temperature and species profiling in rocket engines has been developed at Rocketdyne. In the present effort, the system has been undergoing validation for application to rocket engine component testing. A 4 inch diameter windowed combustor with a coaxial gas-gas injector was chosen for this series of validation experiments. Initially an excimer-pumped tunable dye laser and later a solid state Nd-Yag laser served as excitation sources. The Raman signal was dispersed by a monochromator and detected by a gated, intensified Charged Coupled Device (CCD) array. Experiments were carried out prior to each series of hot fire tests to ensure that the Raman signal detected was due to a spontaneous rather than a stimulated Raman emission process. Over sixty hot fire tests were conducted during the first series of tests with the excimer/dye laser. All hot fire testing was at a mixture ratio of 0.5 and chamber pressures of approximately 100 and approximately 300 psia. The Raman spectra of hydrogen, water vapor and oxygen recorded during single element hot fire tests were reduced and analyzed. A significant achievement was the attainment of single shot Raman spectra in cold flow tests. Unfortunately, the single shot signal-to-noise ratio deteriorated to an unacceptable level during the hot fire testing. Attempts to obtain temperature data from the hydrogen Q1-branch profiles obtained in hot fire tests suggest that potentially complicating factors may render the approach of averaging data on the photodiode array invalid. A second series of hot fire tests was conducted with a 4 element coaxial injector using the Nd-Yag laser. A very compact and portable diagnostics set up was assembled for ease of alignment, relocation and flexibility. Measurements were made at several regions in the chamber in order to map concentration profiles. High spatial resolution and improved signal to noise characteristics were demonstrated.

Farhangi, S.↗

Differential absorption lidars for remote sensing of atmospheric pressure and temperature profiles

A near infrared differential absorption lidar technique is developed using atmospheric oxygen as a tracer for high resolution vertical profiles of pressure and temperature with high accuracy. Solid-state tunable lasers and high-resolution spectrum analyzers are developed to carry out ground-based and airborne measurement demonstrations and results of the measurements presented. Numerical error analysis of high-altitude airborne and spaceborne experiments is carried out, and system concepts developed for their implementation.

Korb, C. Laurence↗

Optical ordnance system for use in explosive ordnance disposal activities

A portable hand-held solid state rod laser system and an optically-ignited detonator have been developed for use in explosive ordnance disposal (EOD) activities. Laser prototypes from Whittaker Ordnance and Universal Propulsion have been tested and evaluated. The optical detonator contains 2-(5 cyanotetrazolato) pentaamine cobalt(III) perchlorate (CP) as the DDT column and the explosive Octahydro- 1,3,5,7 - tetrazocine (HMX) as the output charge. The laser is designed to have an output of 150 mJ in a 500 microsecond pulse. This output allows firing through 2000 meters of optical fiber. The detonator can also be ignited with a portable laser diode source through a shorter length of fiber.

Merson, J. A.↗

Mid-infrared Spectroscopy of Pr-Doped Materials

Solid state lanthanide doped lasers primarily operate in the ultraviolet, visible, near infrared and short-wavelength infrared out to around 2.1 μm. At longer wavelengths, the transitions in conventional oxide crystal and glass materials become susceptible to multiphonon quenching due to their relatively large phonon energy. The use of low phonon materials can minimize the nonradiative quenching, opening up possibilities for solid state lanthanide lasers operating in the mid-infrared (MIR). This provides motivation to study the spectroscopy of lanthanide ions in bromide, chloride and fluoride materials, which have relatively low phonon energies. In this article, the MIR spectroscopy or praseodymium ions in five different host materials is studied, specifically KPb2Br5 (KPB), LaF3, KYF4 (KYF), BaY2F8 (BYF) and YLiF4 (YLF) host crystals. The MIR emission cross sections have been measured from 3 to 6 μm and reciprocity of absorption and emission is utilized to validate the results. The lifetime dynamics in the MIR are covered for various pump and emission wavelengths. Results are also presented on MIR emission from 6.5 to 8.5 μm in a Pr: KPB crystal, which, to the best of the authors knowledge, is the first such measurement of luminescence in this wavelength range that has been published.

Brian M Walsh↗

Nd:Glass-Raman laser for water vapor dial

A tunable solid-state Raman shifted laser which was used in a water vapor Differential Absorption Lidar (DIAL) system at 9400 A is described. The DIAL transmitter is based on a tunable glass laser operating at 1.06 microns, a hydrogen Raman cell to shift the radiation to 1.88 microns, and a frequency doubling crystal. The results of measurements which characterize the output of the laser with respect to optimization of optical configuration and of Raman parameters were reported. The DIAL system was also described and preliminary atmospheric returns shown.

Kagann, R. H.↗

The LASL program in nuclear pumped liquid lasers

The development of nuclear-pumped, liquid-based lanthanide ion lasers is discussed. Early investigations of lanthanide ion lasers have lead to solid-state and gaseous neodymium lasers, and a demonstration of lasing in the liquid state. Solvents containing organic chelating agents have been employed in liquid Eu(+3) and Tb(+3) lasers to extend fluorescence lifetimes, however aprotic solvents have been found to enable the development of large-scale liquid lasers. The advantages to be gained from high-power nuclear-pumped lasers based on lanthanide solutions include the high density of fissile materials possible, and a nuclear pumping cell which can operate in either a nuclear or optical pumping mode is being fabricated at the Los Alamos Scientific Laboratory to investigate the nuclear pumping of liquid lanthanide ion lasers. Areas that need exploration before specific laser design features can be considered include energy channeling within the liquid upon excitation, radiation damage due to solvent dissociation, and reactor technology for the development of a self-critical liquid reactor.

Mansfield, C. R.↗

Insights into the laser-assisted photoelectric effect from solid-state surfaces

Photoemission from a solid surface provides a wealth of information about its electronic structure and dynamic evolution. Ultrafast pump-probe experiments offer real-time access to photon-surface interactions and the resulting electron dynamics. Here, we present a femtosecond time-resolved photoelectron spectroscopy study of laser-assisted photoemission (LAPE) from two different metal surfaces, tungsten and platinum. Utilizing synchronized IR laser and x-ray pulses, photoelectron sideband generation up to the sixth order is observed. A significant material-dependent variation of the LAPE response has not been predicted by previous theoretical models, to the best of our knowledge. The observed phenomena are semiquantitatively reproduced by considering distinct dynamic dielectric responses of the two materials. In conclusion, these findings provide a deeper understanding of the LAPE process and insights into the dynamic interplay between optical laser fields and metal surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Precision Wavelength Monitor for Tunable Laser Systems

A solid-state apparatus for tracking the wavelength of a laser emission has a power splitter that divides the laser emission into at least three equal components. Differing phase shifts are detected and processed to track variations of the laser emission.

Mark E Froggatt↗