Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Modeling and Analysis of Hybrid Pixel Detector Deficiencies for Scientific Applications

Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TMI-2 – A Case Study for PWR Instrumentation Performance During a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focussed upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focused upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification of Daiichi Units 1, 2, and 3 Data for Severe Accident Evaluations - Process and Illustrative Examples from Prior TMI-2 Evaluations

The accidents at the Three Mile Island Unit 2 (TMI-2) Pressurized Water Reactor (PWR) and the Daiichi Units 1, 2, and 3 Boiling Water Reactors (BWRs) provide unique opportunities to evaluate instrumentation exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during the TMI-2 accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This initial review focused on the set of sensors deemed most important by post-TMI-2 instrumentation evaluation programs. Instrumentation evaluation programs focused on data required by TMI-2 operators to assess the condition of the reactor and containment and the effect of mitigating actions taken by these operators. In addition, prior efforts focused on sensors providing data required for subsequent forensic evaluations and accident simulations. To encourage the potential for similar activities to be completed for qualifying data from Daiichi Units 1, 2, and 3, this report provides additional details related to the formal process used to develop a qualified TMI-2 data base and presents data qualification details for three parameters: primary system pressure; containment building temperature; and containment pressure. As described within this report, sensor evaluations and data qualification required implementation of various processes, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design to instruments easily removed from the TMI-2 plant for evaluations. As documented in this report, results from qualifying data for these parameters led to key insights related to TMI-2 accident progression. Hence, these selected examples illustrate the types of activities completed in the TMI-2 data qualification process and the importance of such a qualification effort. These details are documented in this report to facilitate implementation of similar process using data and examinations at the Daiichi Units 1, 2, and 3 reactors so that BWR-specific benefits can be obtained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D Technology for intelligent trackers

At Super-LHC luminosity it is expected that the standard suite of level 1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the level 1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional integrated circuit technology incorporating chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

99 GENERAL AND MISCELLANEOUS↗

Reduction of 1/f noise in graphene after electron-beam irradiation

We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S{sub I}/I{sup 2} (I is the source-drain current) by an order-of magnitude at the radiation dose of 10{sup 4} {mu}C/cm{sup 2}. We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscale autonomous sensor and communications module

Various technologies pertaining to a microscale autonomous sensor and communications module are described herein. Such a module includes a sensor that generates a sensor signal that is indicative of an environmental parameter. An integrated circuit receives the sensor signal and generates an output signal based at least in part upon the sensor signal. An optical emitter receives the output signal and generates an optical signal as a function of the output signal. An energy storage device is configured to provide power to at least the integrated circuit and the optical emitter, and wherein the module has a relatively small diameter and thickness.

97 MATHEMATICS AND COMPUTING↗

Integrating event detection system operation characteristics into sensor placement optimization.

We consider the problem of placing sensors in a municipal water network when we can choose both the location of sensors and the sensitivity and specificity of the contamination warning system. Sensor stations in a municipal water distribution network continuously send sensor output information to a centralized computing facility, and event detection systems at the control center determine when to signal an anomaly worthy of response. Although most sensor placement research has assumed perfect anomaly detection, signal analysis software has parameters that control the tradeoff between false alarms and false negatives. We describe a nonlinear sensor placement formulation, which we heuristically optimize with a linear approximation that can be solved as a mixed-integer linear program. We report the results of initial experiments on a real network and discuss tradeoffs between early detection of contamination incidents, and control of false alarms.

54 ENVIRONMENTAL SCIENCES↗

Conducting metal oxides integrated with the surface acoustic wave (SAW) sensor platform

One or more embodiments relates a single port surface acoustic wave sensor (SAW) device adapted for use in a wide range of operational temperatures and gas phase chemical species. The device includes a piezoelectric crystal substrate; at least one interdigitated electrode/transducer (IDT) positioned on the piezoelectric crystal substrate; and at least one conducting metal oxide film positioned on the piezoelectric crystal substrate and in communication with at least the IDT.

Ohodnicki, Jr., Paul R.↗

Microengineering Pressure Sensor Active Layers for Improved Performance

Abstract Pressure sensors play an integral role in a wide range of applications, such as soft robotics and health monitoring. In order to meet this demand, many groups microengineer the active layer—the layer that deforms under pressure and dictates changes in the output signal—of capacitive, resistive/piezoresistive, piezoelectric, and triboelectric pressure sensors in order to improve sensor performance. Geometric microengineering of the active layer has been shown to improve performance parameters such as sensitivity, dynamic range, limit of detection, and response and relaxation times. There are a wide range of implemented designs, including microdomes, micropyramids, lines or microridges, papillae, microspheres, micropores, and microcylinders, each offering different advantages for a particular application. It is important to compare the techniques by which the microengineered active layers are designed and fabricated as they may provide additional insights on compatibility and sensing range limits. To evaluate each fabrication method, it is critical to take into account the active layer uniformity, ease of fabrication, shape and size versatility and tunability, and scalability of both the device and the fabrication process. By better understanding how microengineering techniques and design compares, pressure sensors can be targetedly designed and implemented.

Ruth, Sara Rachel Arussy↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Enabling The Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

Ohio University (OHIO), West Virginia University (WVU), and American Electric Power (AEP) proposed to study and report on the benefits of 5G wireless cellular technologies for coal-fired power plants. The significant advantages, cost savings, and potential of 5G wireless data communications based sensors promised to usher in a new era of reliable, inexpensive, and powerful embedded systems that had not previously been available for coal-fired power plants. The team built upon existing experience with cellular-based systems, power plant water quality sensing, and high temperature sensors developed during past projects. Principal Investigator Wilhelm had been developing cellular-based sensor data systems with a commercial partner for 10 years, pioneering innovative solar-powered devices that began with 2G technology. The lessons and knowledge gained served as a foundation to demonstrate innovations and potential impacts specific to coal fired power plants enabled by 5G technology, along with integration with existing sensors and systems.

20 FOSSIL-FUELED POWER PLANTS↗