Search NASA⌕ Search

SEARCH · Search NASA

Results for “computation time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Reliability enhancement of Navier-Stokes codes through convergence enhancement

Reduction of total computing time required by an iterative algorithm for solving Navier-Stokes equations is an important aspect of making the existing and future analysis codes more cost effective. Several attempts have been made to accelerate the convergence of an explicit Runge-Kutta time-stepping algorithm. These acceleration methods are based on local time stepping, implicit residual smoothing, enthalpy damping, and multigrid techniques. Also, an extrapolation procedure based on the power method and the Minimal Residual Method (MRM) were applied to the Jameson's multigrid algorithm. The MRM uses same values of optimal weights for the corrections to every equation in a system and has not been shown to accelerate the scheme without multigriding. Our Distributed Minimal Residual (DMR) method based on our General Nonlinear Minimal Residual (GNLMR) method allows each component of the solution vector in a system of equations to have its own convergence speed. The DMR method was found capable of reducing the computation time by 10-75 percent depending on the test case and grid used. Recently, we have developed and tested a new method termed Sensitivity Based DMR or SBMR method that is easier to implement in different codes and is even more robust and computationally efficient than our DMR method.

Choi, K.-Y.↗

Comparison of excess free energy at an interface according to the applied interpolation scheme for elasticity: A phase-field method

Phase-field modeling is an effective simulation technique for modeling microstructure evolution of elastically anisotropic systems. To introduce the elastic energy contribution in a phase field model, an interpolation scheme is used to define the mechanical properties within the phases and across the continuous interface. Several existing interpolation schemes introduce a potential excess elastic energy at the interface, which undesirable effect on microstructure evolution needs to be evaluated. In this study, we focused on three interpolation schemes including Khachaturyan’ scheme (KHS), Voigt–Taylor’s scheme (VTS), and Steinbach–Apel’s scheme (SAS). Comparisons of these schemes’ performances were performed in three configuration types using the MOOSE (Multiphysics Object-Oriented Simulation Environment) framework: bi-crystal, isotropic particle-matrix and anisotropic particle-matrix. The contribution of excess elastic energy on the interface energy as a function of interface width and the computational time to steady-state were evaluated in these three configurations. SAS introduces the lowest excess elastic energy contribution and the VTS has the biggest contribution amongst the considered schemes. Moreover, when modeling precipitation in an anisotropic elastic material, the SAS approach seems to predict more physical convex shapes during growth, making it preferable to KHS and VTS. Finally, as currently implemented, SAS requires the largest computational time and KHS requires the smallest time to reach steady-state amongst the considered schemes.

36 MATERIALS SCIENCE↗

Analysis of Sample Acquisition Dynamics Using Discrete Element Method

The analysis presented in this paper is conducted in the framework of the Ocean Worlds Autonomy Testbed for Exploration Research and Simulation (OceanWATERS) project, currently under development at NASA Ames Research Center. OceanWATERS aims at designing a simulation environment which allows for testing autonomy of scientific lander missions to the icy moons of our solar system. Mainly focused on reproducing the end effector interaction with the inherent terrain, this paper introduces a novel discrete element method (DEM)-based approach to determine forces and torques acting on the lander’s scoop during the sample acquisition process. An accurate force feedback from the terrain on the scoop is required by fault-detection and autonomous decision-making algorithms to identify when the requested torque on the robotic arm’s joints exceeds the maximum available torque. Knowledge of the terrain force feedback significantly helps evaluating the arm’s links structural properties and properly selecting actuators for the joints. Models available in literature constitute a partial representation of the dynamics of the interaction. As an example, Balovnev derived an analytical expression of the vertical and horizontal force acting on a bucket while collecting a sample as a function of its geometry and velocity, soil parameters and reached depth. Although the model represents an adequate approximation of the two force components, it ignores the direction orthogonal to the scoop motion and neglects the torque. This work relies on DEM analysis to compensate for analytical models’ deficiencies and inaccuracies, i. e. provide force and torque 3D vectors, defined in the moving reference (body) frame attached to the scoop, at each instant of the sample collection process. Results from the first presented analysis relate to the specific OceanWATERS sampling strategy, which consists of collecting the sample through five consecutive passes with increasing depth, each pass following the same circularlinear- circular trajectory. Data is collected given a specific scoop design interacting with two types of bulk materials, which may characterize the surface of icy planetary bodies: snow and ice. Although specifically concerned with the OceanWATERS design, this first analysis provides the expected force trends for similar sampling strategies and allows to deduce phenomenological information about the general scooping process. In order to further instruct the community on the use of DEM tools as a solution to the sampling collection problem, two more analyses have been carried out, mainly focused on reducing the DEM computation time, which increases with a decrease in particle size. After running a set of identical simulations, where the only changing parameter is the size of the spherical particle, it is observed that the resulting force trajectories, starting from a given particle size, converge to the true trend. It is deducible that a further decrease in size yields negligible improvements in the accuracy, while it sensibly increases computation time. A final analysis aims at discussing limitations of approximating bulk material particles having a complex shape, e. g. ice fragments, with spheres, by comparing force trends resulting in the two cases for the same simulation scenario.

Catanoso, Damiana↗

Adaptive hybrid simulations for multiscale stochastic reaction networks

The probability distribution describing the state of a Stochastic Reaction Network (SRN) evolves according to the Chemical Master Equation (CME). It is common to estimate its solution using Monte Carlo methods such as the Stochastic Simulation Algorithm (SSA). In many cases, these simulations can take an impractical amount of computational time. Therefore, many methods have been developed that approximate sample paths of the underlying stochastic process and estimate the solution of the CME. A prominent class of these methods include hybrid methods that partition the set of species and the set of reactions into discrete and continuous subsets. Such a partition separates the dynamics into a discrete and a continuous part. Simulating such a stochastic process can be computationally much easier than simulating the exact discrete stochastic process with SSA. Moreover, the quasi-stationary assumption to approximate the dynamics of fast subnetworks can be applied for certain classes of networks. However, as the dynamics of a SRN evolves, these partitions may have to be adapted during the simulation. We develop a hybrid method that approximates the solution of a CME by automatically partitioning the reactions and species sets into discrete and continuous components and applying the quasi-stationary assumption on identifiable fast subnetworks. Our method does not require any user intervention and it adapts to exploit the changing timescale separation between reactions and/or changing magnitudes of copy-numbers of constituent species. We demonstrate the efficiency of the proposed method by considering examples from systems biology and showing that very good approximations to the exact probability distributions can be achieved in significantly less computational time. This is especially the case for systems with oscillatory dynamics, where the system dynamics change considerably throughout the time-period of interest.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convergence acceleration of viscous and inviscid hypersonic flow calculations

The convergence of inviscid and viscous hypersonic flow calculations using a two-dimensional flux-splitting code is accelerated by applying a Richardson-type overrelaxation method. Successful results are presented for various cases; and a 50 percent savings in computer time is usually achieved. An analytical formula for the overrelaxation factor is derived, and the performance of this scheme is confirmed numerically. Moreover, application of this overrelaxation scheme produces a favorable preconditioning for Wynn's epsilon-algorithm. Both techniques have been extended to viscous three-dimensional flows and applied to accelerate the convergence of the compressible Navier-Stokes code. A savings of 40 percent in computer time is achieved in this case.

Cheer, A.↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed.

07 ISOTOPE AND RADIATION SOURCES↗

Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer

Purpose: The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Methods: The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (D{sub m,m}) and dose-to-water in medium (D{sub w,m}), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. Results: For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%-4.4% to AXB doses (both D{sub m,m} and D{sub w,m}); and within 2.5%-6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes ({+-}3%/3 mm criteria) were 94%, 97%, and 98% for AAA, AXB{sub Dm,m}, and AXB{sub Dw,m}, respectively. The differences between AXB and AAA in dose-volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However, differences up to 8% between AXB and AAA were found at lung/soft tissue interface regions for individual IMRT fields. AAA was found to be 5-6 times faster than AXB for IMRT, while AXB was 4-5 times faster than AAA for VMAT plan. Conclusions: AXB is satisfactorily accurate for the dose calculation in lung cancer for both IMRT and VMAT plans. The differences between AXB and AAA are generally small except in heterogeneous interface regions. AXB D{sub w,m} and D{sub m,m} calculations are similar inside the soft tissue and lung regions. AXB can benefit lung VMAT plans by both improving accuracy and reducing computation time.

60 APPLIED LIFE SCIENCES↗

Performance Study of Distance-Weighting Approach with Loopy Sum-Product Algorithm for Multi-Object Tracking in Clutter

In this paper, we explore the performance of the distance-weighting probabilistic data association (DWPDA) approach in conjunction with the loopy sum-product algorithm (LSPA) for tracking multiple objects in clutter. First, we discuss the problem of data association (DA), which is to infer the correspondence between targets and measurements. DA plays an important role when tracking multiple targets using measurements of uncertain origin. Second, we describe three methods of data association: probabilistic data association (PDA), joint probabilistic data association (JPDA), and LSPA. We then apply these three DA methods for tracking multiple crossing targets in cluttered environments, e.g., radar detection with false alarms and missed detections. We are interested in two performance metrics: tracking accuracy and computation time. LSPA is known to be superior to PDA in terms of the former and to dominate JPDA in terms of the latter. Last, we consider an additional DA method that is a modification of PDA by incorporating a weighting scheme based on distances between position estimates and measurements. This distance-weighting approach, when combined with PDA, has been shown to enhance the tracking accuracy of PDA without significant change in the computation burden. Since PDA constitutes a crucial building block of LSPA, we hypothesize that DWPDA, when integrated with LSPA, would perform better under the two performance metrics above. Contrary to expectations, the distance-weighting approach does not enhance the performance of LSPA, whether in terms of tracking accuracy or computation time.

47 OTHER INSTRUMENTATION↗

Multi-institutional Quantitative Evaluation and Clinical Validation of Smart Probabilistic Image Contouring Engine (SPICE) Autosegmentation of Target Structures and Normal Tissues on Computer Tomography Images in the Head and Neck, Thorax, Liver, and Male Pelvis Areas

Purpose: Clinical validation and quantitative evaluation of computed tomography (CT) image autosegmentation using Smart Probabilistic Image Contouring Engine (SPICE). Methods and Materials: CT images of 125 treated patients (32 head and neck [HN], 40 thorax, 23 liver, and 30 prostate) in 7 independent institutions were autosegmented using SPICE and computational times were recorded. The number of structures autocontoured were 25 for the HN, 7 for the thorax, 3 for the liver, and 6 for the male pelvis regions. Using the clinical contours as reference, autocontours of 22 selected structures were quantitatively evaluated using Dice Similarity Coefficient (DSC) and Mean Slice-wise Hausdorff Distance (MSHD). All 40 autocontours were evaluated by a radiation oncologist from the institution that treated the patients. Results: The mean computational times to autosegment all the structures using SPICE were 3.1 to 11.1 minutes per patient. For the HN region, the mean DSC was >0.70 for all evaluated structures, and the MSHD ranged from 3.2 to 10.0 mm. For the thorax region, the mean DSC was 0.95 for the lungs and 0.90 for the heart, and the MSHD ranged from 2.8 to 12.8 mm. For the liver region, the mean DSC was >0.92 for all structures, and the MSHD ranged from 5.2 to 15.9 mm. For the male pelvis region, the mean DSC was >0.76 for all structures, and the MSHD ranged from 4.8 to 10.5 mm. Out of the 40 autocontoured structures reviews by experts, 25 were scored useful as autocontoured or with minor edits for at least 90% of the patients and 33 were scored useful autocontoured or with minor edits for at least 80% of the patients. Conclusions: Compared with manual contouring, autosegmentation using SPICE for the HN, thorax, liver, and male pelvis regions is efficient and shows significant promise for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2008 ALCF annual report.

The word 'breakthrough' aptly describes the transformational science and milestones achieved at the Argonne Leadership Computing Facility (ALCF) throughout 2008. The number of research endeavors undertaken at the ALCF through the U.S. Department of Energy's (DOE) Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program grew from 9 in 2007 to 20 in 2008. The allocation of computer time awarded to researchers on the Blue Gene/P also spiked significantly - from nearly 10 million processor hours in 2007 to 111 million in 2008. To support this research, we expanded the capabilities of Intrepid, an IBM Blue Gene/P system at the ALCF, to 557 teraflops (TF) for production use. Furthermore, we enabled breakthrough levels of productivity and capability in visualization and data analysis with Eureka, a powerful installation of NVIDIA Quadro Plex S4 external graphics processing units. Eureka delivered a quantum leap in visual compute density, providing more than 111 TF and more than 3.2 terabytes of RAM. On April 21, 2008, the dedication of the ALCF realized DOE's vision to bring the power of the Department's high performance computing to open scientific research. In June, the IBM Blue Gene/P supercomputer at the ALCF debuted as the world's fastest for open science and third fastest overall. No question that the science benefited from this growth and system improvement. Four research projects spearheaded by Argonne National Laboratory computer scientists and ALCF users were named to the list of top ten scientific accomplishments supported by DOE's Advanced Scientific Computing Research (ASCR) program. Three of the top ten projects used extensive grants of computing time on the ALCF's Blue Gene/P to model the molecular basis of Parkinson's disease, design proteins at atomic scale, and create enzymes. As the year came to a close, the ALCF was recognized with several prestigious awards at SC08 in November. We provided resources for Linear Scaling Divide-and-Conquer Electronic Structure Calculations for Thousand Atom Nanostructures, a collaborative effort between Argonne, Lawrence Berkeley National Laboratory, and Oak Ridge National Laboratory that received the ACM Gordon Bell Prize Special Award for Algorithmic Innovation. The ALCF also was named a winner in two of the four categories in the HPC Challenge best performance benchmark competition.

59 BASIC BIOLOGICAL SCIENCES↗

Time-mode analog computation circuits and methods

A time-mode analog computation circuit is provided. The time-mode analog computation circuit includes one or more inputs for receiving one or more temporal input signals. The time-mode analog computation circuit further includes circuitry for performing a mathematical operation based on the one or more temporal input signals. A result of the mathematical operation is expressed in a timing of an output signal generated by the circuit.

Ravinuthula, Vishnu V.↗

Multifidelity Uncertainty Quantification with Applications in Wind Turbine Aerodynamics: Preprint

The propagation of input uncertainty through engineering models allows designers to better understand the range of possible outcomes resulting from design decisions. This could lead to greater trust between modelers and stakeholders in the wind energy industry. In this study, we apply multilevel-multifidelity Monte Carlo sampling to flow over an airfoil, assuming uncertainty in the inflow conditions, and characterize the associated computational savings compared to standard Monte Carlo approaches. The truth model is provided by an airfoil simulation with a very fine computational time step, and auxiliary lower-level models are provided by simulations with coarser time steps. Reynolds-averaged Navier Stokes and detached eddy simulations are used to obtain two different model fidelities. The primary quantity of interest for this analysis is the lift force, which is examined for a range of angles of attack. We launch an initial set of 'trial' samples to determine the optimal allocation of model evaluations, and these trial evaluations are used to inform a larger sampling effort. Using the multilevel-multifidelity approach, we achieve roughly an order of magnitude variance reduction in expected lift as compared to the standard Monte Carlo approach with an equivalent computational cost.

17 WIND ENERGY↗

SU-C-BRC-03: Development of a Novel Strategy for On-Demand Monte Carlo and Deterministic Dose Calculation Treatment Planning and Optimization for External Beam Photon and Particle Therapy

Purpose: Accurate and fast dose calculation is a prerequisite of precision radiation therapy in modern photon and particle therapy. While Monte Carlo (MC) dose calculation provides high dosimetric accuracy, the drastically increased computational time hinders its routine use. Deterministic dose calculation methods are fast, but problematic in the presence of tissue density inhomogeneity. We leverage the useful features of deterministic methods and MC to develop a hybrid dose calculation platform with autonomous utilization of MC and deterministic calculation depending on the local geometry, for optimal accuracy and speed. Methods: Our platform utilizes a Geant4 based “localized Monte Carlo” (LMC) method that isolates MC dose calculations only to volumes that have potential for dosimetric inaccuracy. In our approach, additional structures are created encompassing heterogeneous volumes. Deterministic methods calculate dose and energy fluence up to the volume surfaces, where the energy fluence distribution is sampled into discrete histories and transported using MC. Histories exiting the volume are converted back into energy fluence, and transported deterministically. By matching boundary conditions at both interfaces, deterministic dose calculation account for dose perturbations “downstream” of localized heterogeneities. Hybrid dose calculation was performed for water and anthropomorphic phantoms. Results: We achieved <1% agreement between deterministic and MC calculations in the water benchmark for photon and proton beams, and dose differences of 2%–15% could be observed in heterogeneous phantoms. The saving in computational time (a factor ∼4–7 compared to a full Monte Carlo dose calculation) was found to be approximately proportional to the volume of the heterogeneous region. Conclusion: Our hybrid dose calculation approach takes advantage of the computational efficiency of deterministic method and accuracy of MC, providing a practical tool for high performance dose calculation in modern RT. The approach is generalizable to all modalities where heterogeneities play a large role, notably particle therapy.

60 APPLIED LIFE SCIENCES↗

Parametric Analysis of Aircraft WingWeight Using Low-Order Physics-Based Analysis

In the conceptual aircraft design phase, prediction of the empty weight typically relies on empirically-based regression equations which execute quickly and require little detailed information about the internal structural layout. Since they are based on existing aircraft, however, empirical methods can lose their validity for newer technologies and unconventional configurations. Designers can transition to higher-order, physics-based analysis methods to improve the accuracy of the weight prediction, but at the cost of complex model setup and increased computational time. This paper describes a methodology for low-order aero-structural analysis of conceptual aircraft configurations that increases the use of physics-based analysis in conceptual design, but is less complex and time-consuming than higher-order methods such as finite-element analysis. The methodology uses Vehicle Sketch Pad (OpenVSP) to model the aircraft geometry, and ASWING to perform the aero-structural analysis. The internal forces and moments from the ASWING analysis are post-processed to calculate the resulting direct and shear stresses in the structure, and the thickness distributions of the aircraft components are varied to match the maximum von Mises stress at each cross section to the material allowable. To offset the increased computational time relative to empirical weight equations, a process is studied which uses parametric variation to develop a regression equation relating the weight of the aircraft wing to major design variables. This new weight equation is similar to existing empirical equations, but is built using the more physics-based methodology; the new equation could be used to augment or replace portions of the empirical database to improve the validity of the wing weight prediction for unconventional configurations and advanced technologies.

Olson, Erik D.↗

Monitoring by Use of Clusters of Sensor-Data Vectors

The inductive monitoring system (IMS) is a system of computer hardware and software for automated monitoring of the performance, operational condition, physical integrity, and other aspects of the health of a complex engineering system (e.g., an industrial process line or a spacecraft). The input to the IMS consists of streams of digitized readings from sensors in the monitored system. The IMS determines the type and amount of any deviation of the monitored system from a nominal or normal ( healthy ) condition on the basis of a comparison between (1) vectors constructed from the incoming sensor data and (2) corresponding vectors in a database of nominal or normal behavior. The term inductive reflects the use of a process reminiscent of traditional mathematical induction to learn about normal operation and build the nominal-condition database. The IMS offers two major advantages over prior computational monitoring systems: The computational burden of the IMS is significantly smaller, and there is no need for abnormal-condition sensor data for training the IMS to recognize abnormal conditions. The figure schematically depicts the relationships among the computational processes effected by the IMS. Training sensor data are gathered during normal operation of the monitored system, detailed computational simulation of operation of the monitored system, or both. The training data are formed into vectors that are used to generate the database. The vectors in the database are clustered into regions that represent normal or nominal operation. Once the database has been generated, the IMS compares the vectors of incoming sensor data with vectors representative of the clusters. The monitored system is deemed to be operating normally or abnormally, depending on whether the vector of incoming sensor data is or is not, respectively, sufficiently close to one of the clusters. For this purpose, a distance between two vectors is calculated by a suitable metric (e.g., Euclidean distance) and "sufficiently close" signifies lying at a distance less than a specified threshold value. It must be emphasized that although the IMS is intended to detect off-nominal or abnormal performance or health, it is not necessarily capable of performing a thorough or detailed diagnosis. Limited diagnostic information may be available under some circumstances. For example, the distance of a vector of incoming sensor data from the nearest cluster could serve as an indication of the severity of a malfunction. The identity of the nearest cluster may be a clue as to the identity of the malfunctioning component or subsystem. It is possible to decrease the IMS computation time by use of a combination of cluster-indexing and -retrieval methods. For example, in one method, the distances between each cluster and two or more reference vectors can be used for the purpose of indexing and retrieval. The clusters are sorted into a list according to these distance values, typically in ascending order of distance. When a set of input data arrives and is to be tested, the data are first arranged as an ordered set (that is, a vector). The distances from the input vector to the reference points are computed. The search of clusters from the list can then be limited to those clusters lying within a certain distance range from the input vector; the computation time is reduced by not searching the clusters at a greater distance.

Iverson, David L.↗

TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections; 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)

60 APPLIED LIFE SCIENCES↗