Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Magnetic field mapping of inaccessible regions using physics-informed neural networks

A difficult problem concerns the determination of magnetic field components within an experimentally inaccessible region when direct field measurements are not feasible. In this paper, we propose a new method of accessing magnetic field components using non-disruptive magnetic field measurements on a surface enclosing the experimental region. Magnetic field components in the experimental region are predicted by solving a set of partial differential equations (Ampere’s law and Gauss’ law for magnetism) numerically with the aid of physics-informed neural networks (PINNs). Prediction errors due to noisy magnetic field measurements and small number of magnetic field measurements are regularized by the physics information term in the loss function. We benchmark our model by comparing it with an older method. The new method we present will be of broad interest to experiments requiring precise determination of magnetic field components, such as searches for the neutron electric dipole moment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

60 APPLIED LIFE SCIENCES↗

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Error analysis of low-fidelity models for wake steering based on field measurements

The observations collected by two scanning lidars deployed on the roof of a 2.8-MW turbine undergoing a series of imposed yaw offsets are analyzed. The wake lateral displacement detected by the rear-facing lidar correlates well with the yaw offset sensed by the forward-facing lidar. We find that the high-frequency part of the yaw offset signal is connected to wake meandering, whereas the low frequency component is a good predictor for wake displacement due to yaw misalignment. Conditionally averaged wake velocity data for different yaw offsets are used as benchmarks for the validation of a linearized Reynolds-averaged Navier-Stokes and an empirical wake model. A mean error as low as 2% and a good prediction of the wake trajectory are achieved, provided that the wake recovery rate matches the observations.

17 WIND ENERGY↗

Effect of surface free energy on critical field H{sub c3}

The emergence of surface superconductivity in a type I superconductor is considered taking into account the surface free energy of the superconducting phase. It is shown that the disregard of the surface energy leads to a substantial error in determining the Ginzburg-Landau parameter from the measurements of the H{sub c3} field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE PLUTO CODE FOR ADAPTIVE MESH COMPUTATIONS IN ASTROPHYSICAL FLUID DYNAMICS

We present a description of the adaptive mesh refinement (AMR) implementation of the PLUTO code for solving the equations of classical and special relativistic magnetohydrodynamics (MHD and RMHD). The current release exploits, in addition to the static grid version of the code, the distributed infrastructure of the CHOMBO library for multidimensional parallel computations over block-structured, adaptively refined grids. We employ a conservative finite-volume approach where primary flow quantities are discretized at the cell center in a dimensionally unsplit fashion using the Corner Transport Upwind method. Time stepping relies on a characteristic tracing step where piecewise parabolic method, weighted essentially non-oscillatory, or slope-limited linear interpolation schemes can be handily adopted. A characteristic decomposition-free version of the scheme is also illustrated. The solenoidal condition of the magnetic field is enforced by augmenting the equations with a generalized Lagrange multiplier providing propagation and damping of divergence errors through a mixed hyperbolic/parabolic explicit cleaning step. Among the novel features, we describe an extension of the scheme to include non-ideal dissipative processes, such as viscosity, resistivity, and anisotropic thermal conduction without operator splitting. Finally, we illustrate an efficient treatment of point-local, potentially stiff source terms over hierarchical nested grids by taking advantage of the adaptivity in time. Several multidimensional benchmarks and applications to problems of astrophysical relevance assess the potentiality of the AMR version of PLUTO in resolving flow features separated by large spatial and temporal disparities.

79 ASTRONOMY AND ASTROPHYSICS↗

Casting the Coronal Magnetic Field Reconstruction Tools in 3D Using the MHD Bifrost Model

Quantifying the coronal magnetic field remains a central problem in solar physics. Nowadays, the coronal magnetic field is often modeled using nonlinear force-free field (NLFFF) reconstructions, whose accuracy has not yet been comprehensively assessed. Here we perform a detailed casting of the NLFFF reconstruction tools, such as π -disambiguation, photospheric field preprocessing, and volume reconstruction methods, using a 3D snapshot of the publicly available full-fledged radiative MHD model. Specifically, from the MHD model, we know the magnetic field vector in the entire 3D domain, which enables us to perform a “voxel-by-voxel” comparison of the restored and the true magnetic fields in the 3D model volume. Our tests show that the available π -disambiguation methods often fail in the quiet-Sun areas dominated by small-scale magnetic elements, while they work well in the active region (AR) photosphere and (even better) chromosphere. The preprocessing of the photospheric magnetic field, although it does produce a more force-free boundary condition, also results in some effective “elevation” of the magnetic field components. This “elevation” height is different for the longitudinal and transverse components, which results in a systematic error in absolute heights in the reconstructed magnetic data cube. The extrapolations performed starting from the actual AR photospheric magnetogram are free from this systematic error, while other metrics are comparable with those for extrapolations from the preprocessed magnetograms. This finding favors the use of extrapolations from the original photospheric magnetogram without preprocessing. Our tests further suggest that extrapolations from a force-free chromospheric boundary produce measurably better results than those from a photospheric boundary.

79 ASTRONOMY AND ASTROPHYSICS↗

Micrometer: Micromechanics transformer for predicting full field mechanical responses of heterogeneous materials

Predicting mechanical responses of heterogeneous materials across scales remains a significant challenge. Traditional computational methods often struggle with complex and multiscale nature of these materials, limiting their effectiveness in real-world applications. Here, in this paper, we introduce Micrometer, a vision transformer based deep learning model designed to predict full field mechanical responses of heterogeneous materials, bridging the gap between computer vision and solid mechanics problems. We show that Micrometer, trained on a large-scale high-resolution dataset of 2D fiber-reinforced composites, can achieve state-of-the-art performance in predicting microscale strain fields across a wide range of material properties and loading conditions. Our model demonstrates accuracy and computational efficiency in applications such as computational homogenization and multiscale modeling, reducing computational time by up to two orders of magnitude compared to conventional numerical solvers while maintaining less than 1 % errors in predicting macroscale stress fields. Furthermore, we showcase Micrometer’s adaptability through transfer learning experiments on new materials with limited data, highlighting its potential to tackle diverse scenarios in computational solid mechanics. These results represent a significant step towards AI-driven innovation in materials science, addressing the limitations of traditional numerical methods and paving the way for more efficient simulations of heterogeneous materials across various industrial applications.

Composite materials↗

SU-F-BRF-03: Quality Assurance of Deformable Image Registration in Radiotherapy

Purpose: To introduce methods to analyze Deformable Image Registration (DIR) and identify regions of potential DIR errors. Methods: DIR Deformable Vector Fields (DVFs) quantifying patient anatomic changes were evaluated using the Jacobian determinant and the magnitude of DVF curl as functions of tissue density and tissue type. These quantities represent local relative deformation and rotation, respectively. Large values in dense tissues can potentially identify non-physical DVF errors. For multiple DVFs per patient, histograms and visualization of DVF differences were also considered. To demonstrate the capabilities of methods, we computed multiple DVFs for each of five Head and Neck (H'N) patients (P1–P5) via a Fast-symmetric Demons (FSD) algorithm and via a Diffeomorphic Demons (DFD) algorithm, and show the potential to identify DVF errors. Results: Quantitative comparisons of the FSD and DFD registrations revealed <0.3 cm DVF differences in >99% of all voxels for P1, >96% for P2, and >90% of voxels for P3. While the FSD and DFD registrations were very similar for these patients, the Jacobian determinant was >50% in 9–15% of soft tissue and in 3–17% of bony tissue in each of these cases. The volumes of large soft tissue deformation were consistent for all five patients using the FSD algorithm (mean 15%±4% volume), whereas DFD reduced regions of large deformation by 10% volume (785 cm{sup 3}) for P4 and by 14% volume (1775 cm{sup 3}) for P5. The DFD registrations resulted in fewer regions of large DVF-curl; 50% rotations in FSD registrations averaged 209±136 cm{sup 3} in soft tissue and 10±11 cm{sup 3} in bony tissue, but using DFD these values were reduced to 42±53 cm{sup 3} and 1.1±1.5 cm{sup 3}, respectively. Conclusion: Analysis of Jacobian determinant and curl as functions of tissue density can identify regions of potential DVF errors by identifying non-physical deformations and rotations. Collaboration with Phillips Healthcare, as indicated in authorship.

60 APPLIED LIFE SCIENCES↗

Characterizing Dynamic Test Fixtures Through the Modal Projection Error

Across many industries and engineering disciplines, physical components and systems of components are designed and deployed into their environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will survive its physical environment or if it will fail due to mechanical stresses. One method to determine if the component will survive the environment is to expose the component to a simulation of the environment in a laboratory. One difficulty in doing this is that the component may not have the same boundary condition in the laboratory as is in the field configuration. This paper presents a novel method of quantifying the error in the modal domain that occurs from the impedance difference between the laboratory test fixture and the next level of assembly in the field configuration. The error is calculated from the projection from one mode shape space to the other, and the error is in terms of each mode of the field configuration. This provides insight into the effectiveness of the test fixture with respect to the ability to recreate the mode shapes of the field configuration. A case study is presented to show that the error in the modal projection between two configurations is a lower limit for the error that can be achieved by a laboratory test.

42 ENGINEERING↗

Effect of Evanescent Waves on the Dark Current of Thermophotovoltaic Cells

The output power of thermophotovoltaic (TPV) cells may be greatly increased when the gap between the emitter and cell is reduced to submicron distances (near-field regime), at which photon tunneling due to evanescent waves becomes important. Accurate modeling of TPV cells in these conditions is crucial for the design and optimization of near-field TPV systems. The conventional or standard modeling method uses the summation of the dark current and the short-circuit current, while the direct method applies the photon chemical potential. It has been shown that the two methods are linked through a modification of the direct method using Wien’s approximation. By contrasting different modeling approaches, we quantitatively analyze the effects of evanescent waves on the TPV cell performance parameters, especially the dark current, for different emitter and cell materials in the near-field regime. Our results show that the saturation current by radiative recombination is strongly affected by evanescent waves and the bandgap energy. The current-voltage characteristics calculated by different modeling methods are displayed to demonstrate that a constant saturation current typically used in the standard method could cause substantial error in the near-field regime. Finally, for a TPV system with an emitter operating at relatively low temperatures, we show that it is necessary to include the photon chemical potential in the computation of the net radiative heat transfer between the emitter and receiver.

14 SOLAR ENERGY↗

Modeling protein structures from predicted contacts with modern molecular dynamics potentials: accuracy, sensitivity, and refinement

Protein structure prediction has become increasingly popular and successful in recent years. An essential step for fragment-free, template-free methods is the generation of a final three-dimensional protein model from a set of predicted amino acid contacts that are often described by interresidue pairwise atomic distances. Here we explore the use of modern, open-source molecular dynamics (MD) engines, which have been continually developed over the last three decades with all-atom Hamiltonians to model biomolecular structure and dynamics, to generate accurate protein structures starting from a set of inferred pairwise distances. Additionally, the ability of MD empirical physical potentials to correct inaccuracies in the predicted geometries is tested. We rigorously characterize the effect of modeling parameters on results, the effect of different amounts of error in the predicted distances on the final structures, and test the ability of post-processing analysis to sort the best models out of a set of statistical replicas. We find that with exact distances and with noisy distances, the method can produce excellent structural models, and that the molecular dynamics force field seems to help correct errors in distance predictions, resisting the effects of applied noise.

Davidson, Russ↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the bounce-averaging of scattering rates and the calculation of bounce period

For many applications to planetary magnetospheres and elsewhere in the Universe, it is desirable to average physical quantities such as particle and plasma transport coefficients over a charged particle's bounce motion between magnetic mirror points along field lines. In this paper, we perform such bounce-averaging in a way that avoids singularities in the integrands of expressions that arise in calculations of this sort. Our method applies in principle to an almost arbitrary magnetic field model. We illustrate the advantage of using our method for removing the integrand's singularity through a change of variables (rather than by truncating the integral over latitude at points progressively nearer to the mirror point) by computing the component of the bounce-averaged momentum-space diffusion tensor in a dipolar magnetic field both ways for resonance interaction of geomagnetically trapped relativistic (1 MeV) electrons with field-aligned whistler-mode plasma waves at L = 6 (a field line that passes near synchronous altitude). Moreover, we develop improved analytical approximations for particle bounce periods in a dipolar magnetic field by minimizing mean square errors with respect to expansion coefficients in algebraic representations of the bounce period.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Classical Non-Markovian Noise in Symmetry-Preserving Quantum Dynamics

In quantum dynamics, symmetries are vital for identifying and assessing conserved quantities that govern the evolution of a quantum system. When promoted to the open quantum system setting, dynamical symmetries can be negatively altered by system-environment interactions, thus, complicating their analysis. Previous work on noisy symmetric quantum dynamics has focused on the Markovian setting, despite the ubiquity of non-Markovian noise in a number of widely used quantum technologies. Here, in this Letter, we develop a framework for quantifying the impact of non-Markovian noise on symmetric quantum evolution via root space decompositions and the filter function formalism. We demonstrate analytically that symmetry-preserving noise maintains the symmetric subspace, while nonsymmetric noise leads to highly specific leakage errors that are block diagonal in the symmetry representation. We support our findings with numerical studies of a transverse-field Ising model and a quantum error detecting code subject to spatiotemporally correlated multiaxis noise. Our results are broadly applicable, providing new analytic insights into the control and characterization of open quantum system dynamics.

decoherence↗

Optics correction for the multi-pass FFAG ERL machine eRHIC

Gradient errors in the multi-pass Fixed Field Alternating Gradient (FFAG) Energy Recovery Linac (ERL) machine, eRHIC, distort the beam orbit and therefore cause emittance increase. The localization and correction of gradient errors are essential for an effective orbit correction and emittance preservation. In this report, the methodology and simulation of optics correction for the multi-pass FFAG ERL machine eRHIC will be presented.

43 PARTICLE ACCELERATORS↗

Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose at extended distances due to the limits of the dose calculation matrix.

60 APPLIED LIFE SCIENCES↗

Noise in x-ray grating-based phase-contrast imaging

Purpose: Grating-based x-ray phase-contrast imaging is a fast developing new modality not only for medical imaging, but as well for other fields such as material sciences. While these many possible applications arise, the knowledge of the noise behavior is essential. Methods: In this work, the authors used a least squares fitting algorithm to calculate the noise behavior of the three quantities absorption, differential phase, and dark-field image. Further, the calculated error formula of the differential phase image was verified by measurements. Therefore, a Talbot interferometer was setup, using a microfocus x-ray tube as source and a Timepix detector for photon counting. Additionally, simulations regarding this topic were performed. Results: It turned out that the variance of the reconstructed phase is only dependent of the total number of photons used to generate the phase image and the visibility of the experimental setup. These results could be evaluated in measurements as well as in simulations. Furthermore, the correlation between absorption and dark-field image was calculated. Conclusions: These results provide the understanding of the noise characteristics of grating-based phase-contrast imaging and will help to improve image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗