Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Adaptive Virtual Oscillator Control Structure for Grid-Forming Inverters

The electrical grid is facing unprecedented challenges due to the increasing penetration of inverter-based resources. Grid forming inverters (GFMIs) are a promising technology to address these challenges. Recently, the virtual oscillator based GFMI control is attracting more attention due to its superior performance over other control strategies. In this article, an adaptive control strategy is proposed to provide flexible operation and transition between grid-connected and islanded modes. The controller adapts the virtual oscillator's parameter values depending on the operation mode. It also provides a feedback signal using a measured frequency to account for any steady-state errors and to allow a seamless transition from grid-connected to islanded mode. Finally, to show the feasibility of the proposed controller, this article discusses the simulation results from the implementation of the controller on a single inverter system and on a group of inverters on a large practical utility feeder, the IEEE 13 node feeder, using the DIgSILENT simulation environment.

adaptive control↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Distribution Grid Model Publication Investigation

Interest in the external exchange of distribution grid model data is growing around the world, driven largely by the challenges and opportunities presented by the increasing amount of generation, storage, and flexible load being embedded within the distribution grid. This report provides an overview of the current state of distribution grid model data sharing, with a focus on the industry-leading activities currently underway in Great Britain (GB). A second report will explore opportunities for external distribution grid model sharing in the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Services Interface: Architecture, Requirements, and Agreements

This report continues and extends the development of the Energy Services Interface (ESI) that recently has been led by the U.S. Department of Energy’s Grid Modernization Laboratory Consortium. The ESI is intended to facilitate the coordination of multiple, flexible energy resources that work in tandem to satisfy grid objectives by using performance attributes encoded within an ESI Service Template. The ESI relies on a pair of interfaces, representing the service requestor (the consumer of a service) and a service provider (who manages its resources per the agreed performance attributes) to achieve what is commonly known as a “grid service”. Due to its performance-driven approach, the ESI is hypothesized to be able to satisfy all common grid needs via only six common ESI service types. This report first reviews the status of ESI development, including its fundamental tenets. The report makes three important contributions to ESI development: First, it recognizes the similarity between service level agreements and the contract-like agreements that would be needed between energy service requestors and providers and recommends that ESI service agreements be modeled after the web services agreement specification. Second, whereas prior development efforts had focused on a flat, five-stage lifecycle, this report asserts that the ESI should have three behavioral layers in its architecture—the discovery, agreement, and service layers. Finally, this report offers concrete requirements that should be useful toward the development of the service requestors’ and service providers’ respective communications interfaces.

24 POWER TRANSMISSION AND DISTRIBUTION↗

INGRID: An interactive grid generator for 2D edge plasma modeling

A fusion boundary-plasma domain is defined by axisymmetric magnetic surfaces where the geometry is often complicated by the presence of one or more X-points; and modeling boundary plasmas usually relies on computational grids that account for the magnetic field geometry. The new grid generator INGRID (Interactive Grid Generator) presented here is a Python-based code for calculating grids for fusion boundary plasma modeling, for a variety of configurations with one or two X-points in the domain. INGRID first performs partitioning over the domain consisting of a small number of patches conforming to the magnetic field and wall geometry; then it generates a subgrid on each of the patches and joins them into a global grid. This domain partitioning strategy makes possible a uniform treatment of various configurations with one or two X-points in the domain. This includes single-null, double-null, and other configurations with two X-points in the domain. The INGRID design allows generating grids either interactively, via a parameterfile driven GUI, or using a non-interactive script-controlled workflow. Results of testing demonstrate that INGRID is a flexible, robust, and user-friendly grid-generation tool for fusion boundary-plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NARUC grid data sharing playbook

In 2022, the National Association of Regulatory Utility Commissioners (NARUC) launched an initiative to support its members in addressing issues related to grid data sharing. The Grid Data Sharing Collaborative was funded by the DOE’s Office of Electricity and Office of Cybersecurity, Energy Security, and Emergency Response (CESER). NARUC invited programmatic, policy, technical, and cybersecurity subject matter experts from public utility commissions, utilities, non-governmental organizations, energy service companies, and DOE to join the two-year Grid Data Sharing Collaborative to help develop a flexible framework for states to use as a starting point when navigating complex decision-making inherent in grid data sharing. The framework took shape through a series of intensive workshops during which Collaborative participants explored illustrative use cases to identify data needs, articulate the benefits and risks of sharing such data, and assess the trade-offs. Along the way, participants offered suggestions for how the framework could be used in practice. The purpose of this playbook is to describe the elements of the Grid Data Sharing Framework and to begin supporting its implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

INGRID: An interactive grid generator for 2D edge plasma modeling

A fusion boundary-plasma domain is defined by axisymmetric magnetic surfaces where the geometry is often complicated by the presence of one or more X-points; and modeling boundary plasmas usually relies on computational grids that account for the magnetic field geometry. The new grid generator INGRID (Interactive Grid Generator) presented in this work is a Python-based code for calculating grids for fusion boundary plasma modeling, for a variety of configurations with one or two X-points in the domain. INGRID first performs partitioning over the domain consisting of a small number of patches conforming to the magnetic field and wall geometry; then it generates a subgrid on each of the patches and joins them into a global grid. This domain partitioning strategy makes possible a uniform treatment of various configurations with one or two X-points in the domain. This includes single-null, double-null, and other configurations with two X-points in the domain. The INGRID design allows generating grids either interactively, via a parameter-file driven GUI, or using a non-interactive script-controlled workflow. Results of testing demonstrate that INGRID is a flexible, robust, and user-friendly grid-generation tool for fusion boundary-plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Extensible Software and Communication Platform for Distributed Energy Resource Management

This paper introduces a novel Distributed Extensible Grid Control (DEGC) software and communication platform to facilitate the control of distributed energy resources on electric grids. The DEGC software platform leverages state-of-the-art advances in secure, distributed communication and decentralized authorization and authentication. We discuss how these advances enable the kind of robust and secure communication required for a distributed grid control platform, and show how DEGC applies these technologies to the agile development and deployment of grid software through an extensible and flexible API. Here, we describe how DEGC can implement both Volt-VAR voltage magnitude control and Phasor-Based Control as sample applications and demonstrate the DEGC platform in hardware with the demanding Phasor-Based Control test case, and provide performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware Implementation and Market Impacts of Grid-Supportive Functions in End-Use Loads

Grid-supportive loads (GSLs) are power electronics-based end-use loads that can provide frequency response and other grid services by autonomously adjusting their output power using local grid measurements. This report provides details on GSL hardware design options and their associated costs and benefits for multiple devices, including EV chargers, refrigerators, and heat pumps. We consider mechanisms to incentivize adoption of GSLs at scale and estimate the quantity of frequency response that can be procured with GSLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the Charging Flexibility of Shared Automated Electric Vehicle Fleets

The combined anticipated trends of vehicle sharing (ride-hailing), automated control, and powertrain electrification are poised to disrupt the current paradigm of predominately owner-driven gasoline vehicles with low levels of utilization. Shared, automated, electric vehicle (SAEV) fleets offer the potential for lower cost and emissions and have garnered significant interest among the research community. While promising, unmanaged operation of these fleets may lead to unintended negative consequences. One potentially unintended consequence is a high quantity of SAEVs charging during peak demand hours on the electric grid, potentially increasing the required generation capacity. This research explores the flexibility associated with charging loads demanded by SAEV fleets in response to servicing personal mobility travel demands. Travel demand is synthesized in four major United States metropolitan areas: Detroit, MI; Austin, TX; Washington, DC; and Miami, FL. In each of these four cities, SAEV simulations are performed using local projected electricity prices from the Regional Energy Deployment System (ReEDS) for a handful of supply side scenarios. A coordinated charging model is introduced that seeks to reduce fleet charging costs in response to time-varying electricity prices and increasing shares of personal trip demand served (between 1% and 25% of all metro trips served by the SAEV fleet). Simulation results are presented across various scenarios assuming fleetwide coordination to minimize charging energy costs while constrained by offering adequate mobility service to fleet customers. The results indicate that the SAEV charging load is highly flexible; energy costs were shown to reduce between 13% and 46% across a wide range of simulated scenarios. In addition, these savings were realized without detrimentally impacting the fleet’s ability to service trips.

autonomous vehicle↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗