Search NASA⌕ Search

SEARCH · Search NASA

Results for “operator performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Pacific Northwest National Laboratory Facility Radionuclide Emissions Units and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development (R&D) laboratories in Richland, WA, including those associated with Pacific Northwest National Laboratory (PNNL) on the U.S. Department of Energy (DOE)’s Hanford Site and PNNL Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all emission units that have the potential for radionuclide air emissions. Potential emissions are assessed annually by PNNL staff members. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled systems, a description of the buildings, exhaust units, control technologies, and sample extraction details is provided for each registered emission unit. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided. Deregistered emission unit details are provided as necessary for up to 5 years post closure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Addressing Nuclear I&C Modernization Through Application of Techniques Employed in Other Industries

This research focuses on presenting advancements that have been made by non-nuclear I&C OT vendors and potential savings that could be realized by their optimized nuclear industry application. To promote understanding and to bound the initial scope for this effort, a pilot vendor and an associated pilot implementation were chosen as an integrated, presentation example for illustration. This integrated example is unique in that a utility in the United States (Duke Energy) engaged a traditional non-nuclear vendor (Honeywell Process Solutions) to install a non-safety, Distributed Control System (DCS) in four of its nuclear units. Duke Energy is currently exploring performing a “technology refresh” of these installed systems as part of a program to address digital obsolescence. This research presents techniques developed by distributed control system vendors to enable such upgrades and potential methods to employ them in a nuclear industry context. The objectives of such an effort are to minimize the utility cost both to refresh the systems and to put the systems into a repeatable refresh cycle for future obsolescence management. This will enable the utility to maximize the benefits of expanded use of their DCS as part of a larger plant strategy to eliminate obsolete I&C systems, reduce Operating and Maintenance (O&M) costs, and improve operational performance through digitalization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Shot Planning and Analysis Tools

Shot planning and analysis tools (SPLAT) integrate components necessary to help achieve a high over-all operational efficiency of the National Ignition Facility (NIF) by combining near and long-term shot planning, final optics demand and supply loops, target diagnostics planning, and target fabrication requirements. Currently, the SPLAT project is comprised of two primary tool suites for shot planning and optics demand. The shot planning component provides a web-based interface to selecting and building a sequence of proposed shots for the NIF. These shot sequences, or 'lanes' as they are referred to by shot planners, provide for planning both near-term shots in the Facility and long-term 'campaigns' in the months and years to come. The shot planning capabilities integrate with the Configuration Management Tool (CMT) for experiment details and the NIF calendar for availability. Future enhancements will additionally integrate with target diagnostics planning and target fabrication requirements tools. The optics demand component is built upon predictive modelling of maintenance requirements on the final optics as a result of the proposed shots assembled during shot planning. The predictive models integrate energetics from a Laser Performance Operations Model (LPOM), the status of the deployed optics as provided by the online Final Optics Inspection system, and physics-based mathematical 'rules' that predict optic flaw growth and new flaw initiations. These models are then run on an analytical cluster comprised of forty-eight Linux-based compute nodes. Results from the predictive models are used to produce decision-support reports in the areas of optics inspection planning, optics maintenance exchanges, and optics beam blocker placement advisories. Over time, the SPLAT project will evolve to provide a variety of decision-support and operation optimization tools.

42 ENGINEERING↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Tobin, Matthew [Columbia Univ., New York, NY (Unit↗

Integrated Hydrogen Sensor and Separator for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory (NREL) and Acciona Energy USA Global are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). As part of this effort, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 1.33 mbar down to 0.003 mbar. In this paper, we report our most recent work, in which we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Sensor data from the integrated module also provide an estimate of the rate at which hydrogen is being extracted from the headspace gas. We designed and fabricated a laboratory-scale integrated module and determined its performance in our laboratory at NREL. Testing showed that the module performed as expected in both sensing and separating modes. The accuracy of the sensing function was +/-10%. The hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. The integrated module can be installed close to the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. We are currently installing a test-scale process at the Nevada Solar One (NSO) power plant to demonstrate this process and determine its operational performance. Results from the test-scale process will be used to specify and design the full-scale process that will be installed at NSO.

14 SOLAR ENERGY↗

FY25 MOOSE Usability Improvements: 3D Meshing Capabilities, Initiation of Geometry Support for Monte Carlo Tools, and Enhancement of MOOSE/Workbench User Input Interactions

Usability improvements have been made to MOOSE and Workbench in FY25 to enhance usability and user workflows. Assorted enhancement have been made to MOOSE’s intrinsic meshing capabilities in order to enable more flexible and complex meshing of nuclear reactor systems, in particular for 3D applications. Mesh generators have been added to perform operations such as batch mesh generation, surface mesh generation, and creation of 3D transition layers. These mesh generation capabilities make it much easier to generate high quality non-extruded 3D meshes. Additionally, work to integrate Monte Carlo reactor physics simulations into MOOSE-based multi-physics workflows has reached another milestone with the implementation of the Constructive Solid Geometry (CSG) base framework. This framework lays the foundation for mesh generators to offer the user a generic CSG output option (as opposed to a finite element mesh). To support users, workshop on the MOOSE Reactor Module was delivered which featured hands-on examples using the NEAMS Workbench on INL’s High Performance Computing system. Recent updates to the NEAMS Workbench, WASP, and the MOOSE language server have introduced several improvements aimed at making MOOSE-based simulation setup and input management faster, more accurate, and easier to use. Key capabilities that have been added include multi-tab-stop autocompletion, visual input diagnostics, developer-directed data visualizations, upgraded ParaView integration, and Workspace-level file tracking. Together, these changes make it easier for users to build, validate, and manage complex MOOSE-based simulation models — especially those involving reusable components, included files, and datasets. The improvements are designed to save time, reduce input errors, and help users get to a successful simulation run faster, with more confidence in the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NOAA National Centers for Environmental Information Fisheries Acoustics Archive Network Deep Dive

EPOC uses the Deep Dive process to discuss and analyze current and planned science use cases and anticipated data output of a particular use case, site, or project to help inform the strategic planning of a campus or regional networking environment. This includes understanding future needs related to network operations, network capacity upgrades, and other technological service investments. A Deep Dive comprehensively surveys major research stakeholders’ plans and processes in order to investigate data management requirements over the next 5–10 years. Deep Dives help ensure that key stakeholders have a common understanding of the issues and the actions that a campus or regional network may need to undertake to offer solutions. The EPOC team leads the effort and relies on collaboration with the hosting site or network, and other affiliated entities that participate in the process. EPOC organizes, convenes, executes, and shares the outcomes of the review with all stakeholders. Between May 2021 and August 2021, staff members from the Engagement and Performance Operations Center (EPOC) met with researchers and staff from the National Oceanic and Atmospheric Administration (NOAA)'s N-Wave (the Enterprise network that supports the NOAA mission) and National Centers for Environmental Information (NCEI)'s Fisheries Acoustics Archive for the purpose of a recording a Deep Dive into research drivers. The goal of these meetings was to help characterize the requirements for the research use case, and to enable cyberinfrastructure support staff to better understand the needs of the researchers they support.

59 BASIC BIOLOGICAL SCIENCES↗

University of Central Florida Campus-Wide Deep Dive

EPOC uses the Deep Dive process to discuss and analyze current and planned science use cases and anticipated data output of a particular use case, site, or project to help inform the strategic planning of a campus or regional networking environment. This includes understanding future needs related to network operations, network capacity upgrades, and other technological service investments. A Deep Dive comprehensively surveys major research stakeholders’ plans and processes in order to investigate data management requirements over the next 5–10 years. Deep Dives help ensure that key stakeholders have a common understanding of the issues and the actions that a campus or regional network may need to undertake to offer solutions. The EPOC team leads the effort and relies on collaboration with the hosting site or network, and other affiliated entities that participate in the process. EPOC organizes, convenes, executes, and shares the outcomes of the review with all stakeholders. Between December 2020 and August 2021, staff members from the Engagement and Performance Operations Center (EPOC) met with researchers and staff at University of Central Florida (UCF) for the purpose of a Campus-Wide Deep Dive into research drivers. The goal of this meeting was to help characterize the requirements for five campus research use cases and to enable cyberinfrastructure support staff to better understand the needs of the researchers they support.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Assessment of Core Physics Characteristics of Extended Enrichment and Higher Burnup LWR Fuels using the Polaris/PARCS Two-Step Approach. Vol. I: PWR Fuel

Nuclear fuel with extended enrichment (235U enrichment within 5-8 wt%) is one of the evolutionary changes that have been pursued in recent years by commercial light water reactor operators and fuel vendors to improve the fuel cycle economy and operation performance of a nuclear plant. This work assesses the performance of the Polaris/PARCS two-step approach in core physics modeling of the pressurized water reactor cores with extended enrichment fuel, referred to as “LEU+” in this report. A representative LEU+ core with a 24-month fuel cycle developed by Southern Nuclear Company (SNC) was modeled using this two-step approach. A representative LEU core with an 18-month fuel cycle was also modeled to provide a reference for the LEU+ core. As expected, significantly more burnable poison absorbers were used in the LEU+ core to accomodate its higher fuel enrichment. Nine different fuel assembly types were modeled using Polaris for each core to generate the assembly cross sections, which were then processed by GenPMAX to prepare the cross-section data for PARCS. The average specific powers of each fuel batch in each core were derived from VERA results and higher specific powers in fresh assemblies were found in the LEU core due to its less total uranium loading included in the VERA LEU model, given that the total core power was assumed to be the same for both cores. PARCS models were developed to simulate the steady-state operations of both cores. PARCS results on the LEU+ core were first compared with the VERA results for verification purpose; good agreements were seen in soluble boron and burnup distribution results, indicating that the Polaris/PARCS modeling and simulation were correctly implemented. Core physics parameters calculated by PARCS, at zero power physics tests, beginning of cycle (BOC), and end of cycle conditions (EOC), were compared between the LEU+ core and the LEU core, including soluble boron concentration, burnup distributions, assembly and pin power peaking factors, fuel temperature reactivity coefficients, moderator temperature and density reactivity coefficients, control rod worth, and shut down margin. The main differences in PARCS results between the LEU+ and the LEU cores are summarized below: 1)The critical boron concentrations were found to be much higher in the LEU+ core than in the LEU core (1582 vs. 1335 ppm for peak values). 2)Higher assembly radial power peaking factors (1.4 vs. 1.3 for peak values), 2D pin peaking factors (1.53 vs. 1.42 for peak values), and 3D pin peaking factors (1.89 vs. 1.81 for peak values) were found in the LEU+ core than in the LEU core. 3)Significantly higher reactivity coefficients of moderator temperature (and density) were found in LEU+ than in LEU.4)Significantly lower control rod worth at EOC were found in LEU+ than LEU for all but one control banks.5)Significantly lower shut down margins were found in the LEU+ core than in the LEU core. The Polaris/GenPMAX/PARCS code suite was found to be capable of modeling the LEU+ PWR core for steady-state operations and no unexpected results in core physics parameters were observed, in spite of that a) several bugs in PARCS were identified and workarounds were used; b) several features were found lacking in the current version of PARCS that would be useful for core modeling. A list of requests for bug fixes and feature upgrades for PARCS originated from this work were transmitted to the code developers. The assessments on the performance of the Polaris/PARCS two-step approach in core modeling for boiling water reactor with LEU+ fuel is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of Test Beds to Facilitate Implementation of Innovative Technologies at Complex Sites - 17147

The Department of Energy, Office of Environmental Management (DOE-EM) has invested significant resources targeted at reducing risk to the environment and to the public. Considerable progress has been achieved, yet major remediation challenges remain. DOE-EM recognizes that new, innovative technologies offer the potential to improve operational performance, accelerate schedules, and reduce cost for environmental cleanup. One challenge that often limits the adoption of new technologies is the lack of information about their performance under real-world conditions. This is particularly true of the complex radiological and chemical environments present at many DOE-EM sites. Test-beds provide a useful approach to test new technologies and technical approaches. With the ability to be field-scale, meso-scale, and/or lab-scale in size and scope, test-beds allow scientists and researchers to explore theories, technologies and tools within replicated, 'real-world' physical, chemical and environmental conditions. To address this challenge, DOE-EM is managing a suite of test-beds and prototype test facilities. The focus of test-bed efforts is on several key issues and challenges that confront site operators. Priority environmental remediation concerns are technetium-99, cesium-137, and strontium-90. Additionally, DOE-EM has determined that advanced robotic and remote sensing techniques offer promise in increasing operational efficiency, reducing personnel exposure, and enhancing safety. Savannah River National Laboratory is implementing a test-bed program. Selection of technologies and alignment with test-beds will depend on applicability to DOE-EM issues, technology maturity, a site's ability to host vendors (industry, SBIR, academia, national laboratories), and availability of supporting infrastructure. Viable results are generated through the test-bed process so that these solutions can be utilized in larger-scale thereby facilitating quick implementation of new technologies at DOE sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle—Pacific Northwest Division operates numerous research and development laboratories in Richland, Washington, including those associated with the Pacific Northwest National Laboratory (PNNL) on the Department of Energy’s Hanford Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all effluent release points that have the potential for radionuclide emissions. Potential emissions are assessed annually. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission point system performance, operation, and design information. A description of the buildings, exhaust points, control technologies, and sample extraction details is provided for each registered or deregistered facility emission point. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided.

radionuclide air emission↗

National Ignition Facility and Managing Location, Component, and State

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system coupled with a 10-meter diameter target chamber. There are over 6,200 Line Replaceable Units (LRUs) comprised of more than 104,000 serialized parts that make up the NIF. Each LRU is a modular unit typically composed of a mechanical housing, laser optics (glass, lenses, or mirrors), and utilities. To date, there are more than 120,000 data sets created to characterize the attributes of these parts. Greater than 51,000 Work Permits have been issued to install, maintain, and troubleshoot the components. One integrated system is used to manage these data, and more. The Location Component and State (LoCoS) system is a web application built using Java Enterprise Edition technologies and is accessed by over 1,200 users. It is either directly or indirectly involved with each aspect of NIF work activity, and interfaces with ten external systems including the Integrated Computer Control System (ICCS) and the Laser Performance Operations Model (LPOM). Besides providing business functionality, LoCoS also acts as the NIF enterprise service bus. In this role, numerous integration approaches had to be adopted including: file exchange, database sharing, queuing, and web services in order to accommodate various business, technical, and security requirements. Architecture and implementation decisions are discussed.

42 ENGINEERING↗

Enhanced Thermal Conductivity UO{sub 2}-BeO and UO{sub 2}-SiC Fuels Behavior

Commercial light-water reactors currently use UO{sub 2} as a nuclear fuel, which has demonstrated several desirable characteristics. However, UO{sub 2} has a low thermal conductivity that leads to the development of a large temperature gradient across the fuel pellet. This temperature gradient contributes to limits in the operational performance of the reactor due to effects that include thermal stresses causing pellet cladding interaction and the release of fission product gases as demonstrated. These high fuel temperatures can be decreased and reactor performance improved by developing an enhanced thermal conductivity nuclear fuel. A high thermal conductivity nuclear fuel would decrease fuel temperatures and facilitate a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling as described. Additionally, fission gas release would be decreased allowing for higher fuel burn-up, and the safety of the reactor would be improved with a faster thermal response and less stored energy in the fuel pins. A ceramic-ceramic composite nuclear fuel has an increased effective thermal conductivity due to adding a second compatible and high thermal conductivity ceramic to UO{sub 2}. SiC and BeO are two materials that demonstrate compatibility with UO{sub 2} and have a high thermal conductivity. In summary, the enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuel performance has been modelled in a light water reactor, and a more complete and detailed understanding was achieved for enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuels. BeO and SiC have high melting point, low neutron absorption, low thermal expansion coefficient and chemical compatibility with current UO{sub 2} fuels which makes them a suitable material for thermal conductivity enhancement. In our modeling and simulation work, the enhanced thermal conductivity nuclear fuel showed the capability of decreasing the fuel temperatures, increasing the gap total conductance, reducing the fission gas release, decreasing the gap/plenum pressure, lessening oxygen redistribution, and facilitating a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling. The safety of the reactor operation would be then improved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

Selective recovery of rare earth elements with ligand-functionalized polymers in fixed-bed adsorption columns

Rare earth elements (REE) are a group of valuable metals with growing demand and broad applications. Mineral ores, the traditional sources of REE, require significant capital investment and their refinement has been a source of environmental contamination. Industrial fluids and natural REE-bearing liquids are potential alternative sources for these metals. This work investigated the performance and REE selectivity of polymer resin beads functionalized with N,N-bis(phosponomethyl)glycine (BPG) for extraction of REE from saline solutions in fixed-bed adsorption columns. Competitive batch adsorption experiments were conducted with various metals (Nd, Gd, Ho, Al, Fe, Co, Ni, Ba, Pb, Th, and U) and the BPG-functionalized resins were up to 137 times more selective for REE than aminated resins. In column experiments, the BPG-functionalized resins preferentially adsorbed heavier metals and REE were strongly retained in the functionalized column, taking 270 times longer than the amine column to reach 10% breakthrough and 128 times longer to reach 50% breakthrough. REE bound to the BPG-functionalized resins were recovered with a dilute HNO3 solution, yielding REE concentrations up to 236 times higher than the influent feedstock. This work provides new insight into the operational performance of novel functionalized adsorbents for recovery of REE from saline fluids.

42 ENGINEERING↗