Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$\alpha$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $\mu$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feynman diagrams and a combination of the integration by parts and the integration by fractional expansion techniques

In this paper, we show how to improve and extend the integration by fractional expansion technique (IBFE) by applying it to certain families of scalar massive Feynman diagrams. The strategy is based on combining this method together with the integration by parts technique. In particular, we want to calculate certain Feynman diagrams which have a triangle loop as a subgraph. The main idea is to use the integration by parts technique in this subgraph in order to simplify the topology of the original diagram in which it is immersed, using then, in a second step, the IBFE technique. The result we have obtained, after the application of both techniques, represents a simplification in the complexity of the solution, compared with having used only the IBFE technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Third Harmonic Voltage Injection Technique to Improve The Power Transmission Capacity

To facilitate the growing deployment of renewable energy sources and increasing load demand, it is imperative to increase the power transmission capacity of the existing transmission corridors. The available power uprating techniques are either costly, or require significant alteration to the existing system. Moreover, most of these techniques are suitable for long transmission lines. In light of these limitations, a third harmonic voltage injection based power uprating technique is proposed in this article. The proposed technique is economic, immune to line impedance unbalance, and is applicable for any length of transmission line. Most importantly, the technique needs very minimal modification in the existing system at the substation level. The efficacy of the proposed technique is validated through simulation and experiments.

Das, Anubrata↗

Novel Histogram Based Unsupervised Classification Technique to Determine Natural Classes From Biophysically Relevant Fit Parameters to Hyperspectral Data

Hyperspectral image analysis has benefited from an array of methods that take advantage of the increased spectral depth compared to multispectral sensors; however, the focus of these developments has been on supervised classification methods. Lack of a priori knowledge regarding land cover characteristics can make unsupervised classification methods preferable under certain circumstances. An unsupervised classification technique is presented in this paper that utilizes physically relevant basis functions to model the reflectance spectra. These fit parameters used to generate the basis functions allow clustering based on spectral characteristics rather than spectral channels and provide both noise and data reduction. Histogram splitting of the fit parameters is then used as a means of producing an unsupervised classification. Unlike current unsupervised classification techniques that rely primarily on Euclidian distance measures to determine similarity, the unsupervised classification technique uses the natural splitting of the fit parameters associated with the basis functions creating clusters that are similar in terms of physical parameters. The data set used in this work utilizes the publicly available data collected at Indian Pines, Indiana. This data set provides reference data allowing for comparisons of the efficacy of different unsupervised data analysis. The unsupervised histogram splitting technique presented in this paper is shown to be better than the standard unsupervised ISODATA clustering technique with an overall accuracy of 34.3/19.0% before merging and 40.9/39.2% after merging. Finally, this improvement is also seen as an improvement of kappa before/after merging of 24.8/30.5 for the histogram splitting technique compared to 15.8/28.5 for ISODATA.

58 GEOSCIENCES↗

A Comparative Study of Interface Techniques for Transmission and Distribution Dynamic Co-Simulation

Transmission and distribution (T&D) dynamic co-simulation is a practical and effective approach to leverage existing simulation tools for transmission and distribution systems to simulate dynamic stability and performance of T&D systems in a systematic manner. Given that these tools are developed as stand-alone programs and there are inherent differences between them, interface techniques become critical to “bridge” them. Two important unsolved questions are: 1) which interface technique is better and should be used, and 2) how the modeling and simulation capabilities in these tools that are available and can be exploited for co-simulation should be considered when selecting an interface technique. This paper presents a comprehensive study for different interface techniques that can be employed for T&D dynamic co-simulation. The study provided insights to the pros and cons of each interface technique, and helped researchers make informed decisions on choosing a proper interface technique.

Huang, Qiuhua↗

Analyzing the effectiveness of a frame-level redundancy scrubbing technique for SRAM-based FPGAs

Radiation effects such as soft errors are the major threat to the reliability of SRAM-based FPGAs. This work analyzes the effectiveness in correcting soft errors of a novel scrubbing technique using internal frame redundancy called Frame-level Redundancy Scrubbing (FLR-scrubbing). This correction technique can be implemented in a coarse grain TMR design. The FLR-scrubbing technique was implemented on a mid-size Xilinx Virtex-5 FPGA device used as a case study. The FLR-scrubbing technique was tested under neutron radiation and fault injection. Implementation results demonstrated minimum area and energy consumption overhead when compared to other techniques. The time to repair the fault is also improved by using the Internal Configuration Access Port (ICAP). Lastly, neutron radiation test results demonstrated that the proposed technique is suitable for correcting accumulated SEUs and MBUs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters

This article presents a space vector pulsewidth modulation (SVPWM) technique for wide bandgap (WBG) device-based three-level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this article, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures dc bus capacitor voltage balancing and minimizes circulating current. Here, the SVPWM technique is experimentally verified using a GaN-based 3L six-phase active neutral point clamped (ANPC) inverter prototype, and the results are presented in this article.

42 ENGINEERING↗

Core-drilling technique for in-situ stress evaluation in concrete structures

SummaryFor assessing the existing stresses in distressed reinforced concrete/prestressed concrete structures, the concrete core-drilling technique can be used. This core-drilling technique is a stress measurement technique in which a small core is drilled on the structure and the strain perturbations around the core are measured by instrumenting strain gages aligned in the same direction. Laboratory studies were conducted to evaluate the reliability of this concrete core-drilling technique. Calibration coefficients were evaluated experimentally for the used gage length, location, and configuration. Comparison was also made with coefficients evaluated theoretically. This technique is suitable for prestressed concrete girders where girders are prestressed in one direction (longitudinally). Also in reinforced concrete members like columns, compression zones of beams on the major bending axis (along the span) can be evaluated for their in-situ stresses. This concrete core-drilling technique can be used to determine the in-situ stress with enhanced sensitivity in “in-service” prestressed concrete structures.

36 MATERIALS SCIENCE↗

A technique optimization protocol and the potential for dose reduction in digital mammography

Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems. The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established techniques based on screen- film. An objective figure of merit (FOM) was employed to evaluate a direct-conversion amorphous selenium (a-Se) FFDM system (Siemens Mammomat Novation{sup DR}, Siemens AG Medical Solutions, Erlangen, Germany) and was derived from the quotient of the squared signal-difference-to-noise ratio to mean glandular dose, for various combinations of technique factors and breast phantom configurations including kilovoltage settings (23-35 kVp), target/filter combinations (Mo-Mo and W-Rh), breast-equivalent plastic in various thicknesses (2-8 cm) and densities (100% adipose, 50% adipose/50% glandular, and 100% glandular), and simulated mass and calcification lesions. When using a W-Rh spectrum, the optimized FOM results for the simulated mass and calcification lesions showed highly consistent trends with kVp for each combination of breast density and thickness. The optimized kVp ranged from 26 kVp for 2 cm 100% adipose breasts to 30 kVp for 8 cm 100% glandular breasts. The use of the optimized W-Rh technique compared to standard Mo-Mo techniques provided dose savings ranging from 9% for 2 cm thick, 100% adipose breasts, to 63% for 6 cm thick, 100% glandular breasts, and for breasts with a 50% adipose/50% glandular composition, from 12% for 2 cm thick breasts up to 57% for 8 cm thick breasts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the robustness of the preprocessing technique improving reversible compressibility of CT images: Tested on various CT examinations

Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique was developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-16: A Hybrid VMAT/IMRT Technique for the Treatment of Nasopharyngeal Carcinoma

Purpose: To investigate a Hybrid VMAT/IMRT technique which combines volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods: 2 full arcs VMAT, 9-field IMRT and Hybrid VMAT/IMRT plans were created for 10 patients with NPC. The Hybrid VMAT/IMRT technique consisted of 1 full VMAT arc and 7 IMRT fields. The dose distribution of planning target volume (PTV) and organs at risk (OARs) for Hybrid VMAT/IMRT was compared with IMRT and VMAT. The monitor units (MUs) were also evaluated. Results: The Hybrid VMAT/IMRT technique significantly improved target dose homogeneity compared with IMRT and VMAT for PTV70 and PTV54. For PTV70 and PTV60, the Hybrid VMAT/IMRT technique significantly improved target dose conformity compared with IMRT (0.62 vs 0.47; p<0.05 and 0.64 vs 0.58; p<0.05, respectively) and VMAT (0.62 vs 0.43; p<0.05 and 0.64 vs 0.6; p<0.05, respectively). The near maximum dose (D2%) of temporomandibular joint (TMJ), temporal lobe and mandible for Hybrid plans were 5.5%, 7.9% and 5.2% lower than IMRT plans (p<0.05). The mean dose of TMJ, temporal lobe, mandible and unspecified tissue for Hybrid plans were 12.8%, 11.4%, 4.2% and 4.1% lower than IMRT plans (p<0.05). The mean dose of right parotid, mandible and unspecified tissue for Hybrid plans were 3.3%, 2.4% and 3.1% lower than VMAT plans (p<0.05). The mean MUs needed for IMRT, VMAT and Hybrid plans were 2256, 507 and 1394, respectively. Conclusion: Hybrid VMAT/IMRT technique significantly improved the target dose homogeneity and conformity compared with IMRT and VMAT and reduced the dose of OARs and unspecified tissue compared with IMRT with fewer MUs. Compared with VMAT, Hybrid VMAT/IMRT technique can better protect parotid gland, mandible and unspecified tissue. Ruijie Yang was funded by the grant project: National Natural Science Foundation of China (No. 81071237). Other authors have no competing interest for this work.

60 APPLIED LIFE SCIENCES↗

SU-E-T-561: Development of Depth Dose Measurement Technique Using the Multilayer Ionization Chamber for Spot Scanning Method

Purpose: To develop a measurement technique which suppresses the difference between profiles obtained with a multilayer ionization chamber (MLIC) and with a water phantom. Methods: The developed technique multiplies the raw MLIC data by a correction factor that depends on the initial beam range and water equivalent depth. The correction factor is derived based on a Bragg curve calculation formula considering range straggling and fluence loss caused by nuclear reactions. Furthermore, the correction factor is adjusted based on several integrated depth doses measured with a water phantom and the MLIC. The measured depth dose profiles along the central axis of the proton field with a nominal field size of 10 by 10 cm were compared between the MLIC using the new technique and the water phantom. The spread out Bragg peak was 20 cm for fields with a range of 30.6 cm and 6.9 cm. Raw MLIC data were obtained with each energy layer, and integrated after multiplying by the correction factor. The measurements were performed by a spot scanning nozzle at Nagoya Proton Therapy Center, Japan. Results: The profile measured with the MLIC using the new technique is consistent with that of the water phantom. Moreover, 97% of the points passed the 1% dose /1mm distance agreement criterion of the gamma index. Conclusion: We have demonstrated that the new technique suppresses the difference between profiles obtained with the MLIC and with the water phantom. It was concluded that this technique is useful for depth dose measurement in proton spot scanning method.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-101: An Arc Based Treatment Technique for Proton PBS Beam Utilizing Overlaid Bragg Peak Spots

Purpose: When Bragg peaks from proton PBS beams are overlaid from a large number of directions, it creates a localized dose distribution with rapid falloff. By positioning these overlaid Bragg peak (OBP) spots strategically throughout the targeted volume, a uniform and conformal dose distribution can be achieved. When PBS spots from all the directions are delivered in an arc fashion, it becomes the Volume Modulated Proton Therapy (VMPT) technique which corresponds to the VMAT technique in photon therapy. Methods: PBS beam from an IBA machine and a 20cm radius cylindrical phantom were simulated with GATE/GEANT4. To position the OBP spot at the center of the phantom, single energy PBS beam from 10/36/360 equally-spaced directions around the phantom was used. To position the OBP spot at an off-center position, PBS beams with various energies were used. To form a uniform dose distribution in 1D/2D, OBP spots are positioned in arrays with spot intervals and weight optimized. Results: Dose profile for single energy OBP spot improved when the number of beam angles increased from 10 to 36, but remained same from 36 to 360 angles. Multi-energy OBP spot had a slightly non-symmetrical profile due to the different energy proton beams used. By optimizing each OBP spot’s weight, 11 OBP spots with 10mm interval size created a uniform dose distribution covering a length of 10cm. Similarly, 11×11 OBP spots in an array of 10mm interval size created a uniform dose distribution covering an area of 10×10cm{sup 2}. Conclusion: We demonstrated the technique of using OBP spots to deliver uniform dose in 1D/2D. This technique can be easily extended through the optimization of position and weight of OBP spots in 3D and becomes the arc based VMPT technique. Further studies are needed to explore the optimization methods and full potential of the VMPT technique.

60 APPLIED LIFE SCIENCES↗

SU-E-T-772: Uncertainties in Treatment Planning for IROC-Houston Proton Phantom QA Program Due to Variable CT Technique and Proton Energy

Purpose: To understand the uncertainties in proton therapy treatment planning for the IROC- Houston proton phantom QA program due to variations in CT technique and proton energy. Methods: A CT phantom used by IROC-H during therapy site visits was scanned using three CT techniques (80, 120, 140kV) with a CT scanner used for proton therapy simulations and irradiated with a passively scattered beam at three energies (140, 200, 250 MeV) to measure, respectively, HU and Relative Linear Stopping Power (RLSP) in order to create HU to RLSP calibration curves for comparison with reference curves used by current proton treatment planning systems. The phantom has proton equivalent materials with a wide variety of HU and RLSPs to allow for the creation of a calibration curve for common tissue equivalent materials. Treatment plans were created for a lung phantom using the various CT technique/ beam energy calibration curves to determine the differences in the dose distributions by performing a gamma analysis. Results: Comparison of the calibration curves created using the phantom materials showed a maximum difference of 12% for a given material between the custom curve and the reference curve currently used by the treatment planning system. The highest differences were a Result of using an 80 kV CT technique and a 250 MeV high proton energy. A comparison of the completed treatment plans will be presented. Conclusion: These results indicate the possibility of differences in proton HU to RLSP calibration curves caused by varying CT technique and proton energy that could manifest as differences in planned and delivered dose distributions, particularly at high proton energies and low kV CT techniques. These differences could Result in discrepancies not accounted for by IROC-Houston and could possibly affect proton institutions’ pass rate when irradiating the proton phantoms.

60 APPLIED LIFE SCIENCES↗

MO-B-BRD-03: Principles, Pitfalls and Techniques of 3D Printing for Bolus and Compensators

This session is designed so that the learning objectives are practical. The intent is that the attendee may take home an understanding of not just the technology, but also the logistical steps necessary to execute these 3D printing techniques in the clinic. Four practical 3D printing topics will be discussed: (i) Creating bolus and compensators for photon machines; (ii) tools for proton therapy; (iii) clinical applications in imaging; (iv) custom phantom design for clinic and research use. The use of 3D printers within the radiation oncology setting is proving to be a useful tool for creating patient specific bolus and compensators with the added benefit of cost savings. Creating the proper protocol is essential to ensuring that the desired effect is achieved and modeled in the treatment planning system. The critical choice of printer material (since it determines the interaction with the radiation) will be discussed. Selection of 3D printer type, design methods, verification of dose calculation, and the printing process will be detailed to give the basis for establishing your own protocol for electron and photon fields. A practical discussion of likely obstacles that may be encountered will be included. The diversity of systems and techniques in proton facilities leads to different facilities having very different requirements for beam modifying hardware and quality assurance devices. Many departments find the need to design and fabricate facility-specific equipment, making 3D printing an attractive technology. 3D printer applications in proton therapy will be discussed, including beam filters and compensators, and the design of proton therapy specific quality assurance tools. Quality control specific to 3D printing in proton therapy will be addressed. Advantages and disadvantages of different printing technology for these applications will also be discussed. 3D printing applications using high-resolution radiology-based imaging data will be presented. This data is used to 3D print individualized physical models of patient’s unique anatomy for aid in planning complex and challenging surgical procedures. Methods, techniques and imaging requirements for 3D printing anatomic models from imaging data will be discussed. Specific applications currently being used in the radiology clinic will be detailed. Standardized phantoms for radiation therapy are abundant. However, custom phantom designs can be advantageous for both clinical tasks and research. 3D printing is a useful method of custom fabrication that allows one to construct custom objects relatively quickly. Possibilities for custom radiotherapy phantoms range from 3D printing a hollow shell and filling the shell with tissue equivalent materials to fully printing the entire phantom with materials that are tissue equivalent as well as suitable for 3D printing. A range of materials available for use in radiotherapy phantoms and in the case of phantoms for dosimetric measurements, this choice is critical. The necessary steps required will be discussed including: modalities of 3D model generation, 3D model requirements for 3D printing, generation of machine instructions from the 3D model, and 3D printing techniques, choice of phantoms material, and troubleshooting techniques for each step in the process. Case examples of 3D printed phantoms will be shown. Learning Objectives: Understand the types of 3D modeling software required to design your device, the file formats required for data transfer from design software to 3D printer, and general troubleshooting techniques for each step of the process. Learn the differences between materials and design for photons vs. electrons vs. protons. Understand the importance of material choice and design geometries for your custom phantoms. Learn specific steps of quality assurance and quality control for 3D printed beam filters and compensators for proton therapy. Learn of special 3D printing applications for imaging. Cunha: Research support from Phillips Healthcare.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-00: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-01: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: Introduction and KV Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRD-02: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: MV Tracking

Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniques for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.

60 APPLIED LIFE SCIENCES↗