Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryocooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Origins Space Telescope: Baseline Mission Concept

The Origins Space Telescope will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did galaxies evolve from the earliest galactic systems to those found in the Universe today? How do habitable planets form? How common are life-bearing worlds? To answer these alluring questions, Origins will operate atmid- and far-infrared (IR) wavelengths and offer powerful spectroscopic instruments and sensitivity three orders of magnitude better than that of the Herschel Space Observatory, the largest telescope flown in space to date. We describe the baseline concept for Origins recommended to the 2020 US Decadal Survey in Astronomy and Astrophysics. The baseline design includes a 5.9-m diameter telescope cryocooled to 4.5 K and equipped with three scientific instruments. A mid-infrared instrument (Mid-Infrared Spectrometer and Camera Transit spectrometer) will measure the spectra of transiting exoplanets in the 2.8 to 20 μm wavelength range and offer unprecedented spectrophotometric precision, enabling definitive exoplanet biosignature detections. The far-IR imager polarimeter will be able to survey thousands of square degrees with broadband imaging at 50 and 250 μm. The Origins Survey Spectrometer will cover wavelengths from 25 to 588 μm, making wide-area and deep spectroscopic surveys with spectral resolving power R ∼ 300, and pointed observations at R ∼ 40;000 and 300,000 with selectable instrument modes. Origins was designed to minimize complexity. The architecture is similar to that of the Spitzer Space Telescope and requires very few deployments after launch, while the cryothermal system design leverages James Webb Space Telescope technology and experience. A combination of current-state-of-the-art cryocoolers and next-generation detector technology will enable Origins’ natural background-limited sensitivity.

David Leisawitz↗

Thermal Performance Comparison and Lessons Learned for the Thermal Infrared Sensor Instruments 1 & 2

The Thermal Infrared Sensor (TIRS-1) is one of two instruments on the Landsat-8 Mission, which launched in February of 2013 and remains operational. The TIRS-2 instrument was developed for the Landsat-9 Mission, which is scheduled to launch in September of 2021. The TIRS-2 instrument design was adjusted to account for requirements changes and to include key lessons learned from its predecessor. The overall thermal subsystem design of the TIRS Sensor Unit remained comparable from mission to mission, but there were some areas that needed modifications. The general design is comprised of five thermal zones which range in temperature from less than 43 Kelvin to 320 Kelvin. Most zones are proportional heater controlled. A two-stage cryocooler provided by Ball Aerospace is used to cool the cryogenic subsystem, and excess power dissipation is rejected via ammonia transport heat pipes to a dedicated cryocooler radiator with embedded ammonia heat pipes. The cryogenic subsystem includes a series of shells used to radiatively and conductively isolate the cold stage from the warmer surroundings. The Optical System (telescope) is passively cooled to 180-195 Kelvin using a dedicated radiator with embedded dual-bore ethane heat pipes. The warmer end of the instrument includes a Scene Select Mechanism, an on-board Black Body Calibrator with a dedicated radiator, and a Focal Plane Electronics Box, all of which are attached to the Sensor Unit primary structure. The TIRS-1 thermal subsystem design was successfully verified during an extended testing campaign and during more than 8years of on-orbit operations. The TIRS-2 thermal subsystem design was successfully verified during months of ground testing prior to delivery in August of 2019and at the Observatory level in the Spring of 2021. A detailed comparison of the thermal performance of the two instruments has been made with a focus on key lessons learned during each instrument development, and with the benefit of on-orbit data acquired for the TIRS-1 instrument.

Veronica Otero↗

Numerical Modeling and Design of Gaseous Propellant Acquisition System for the Triton Hopper

Triton, the largest moon around Neptune, is a captured Kuiper Belt Object with a dynamic rarified atmosphere, active geysers, and unique “cantaloupe” like terrain. Little is known about Kuiper Belt Objects in the scientific community with most of the information coming from Pluto. Currently, NASA is designing an unmanned probe to explore the atmosphere and surface of Triton. This vehicle is unique in that it repeatedly takes off and lands (hops) using nitrogen propellant collected from its surroundings on Triton. This paper presents preliminary conceptual system design and numerical modeling of the atmospheric collection process. Four concepts are presented: a cryocooler-based system, a pump-based system, a sublimation and pump-based system, and a cryocooler and sublimation system. Numerical modeling takes into account the mass and energy transfer between all the relevant nodes in the system and is able to calculate the amount of nitrogen ice collected and ice accumulation rate as a function of time for each concept. The models are ultimately used to assess the feasibility of traversing from equator to pole in under two years using a gaseous propellant acquisition system for the Hopper.

Hopper↗

Thermal Radiator for CO2 Deposition in Deep Space Transit (FY21 XHab Final Report - University of North Texas)

This UNT Senior design team was tasked by NASA to develop a variable conductance thermal radiator prototype for CO2 deposition for deep space transit. NASA selects university teams every year to partake in the X-HAB Academic Innovation Challenge, with this year’s number of teams being six. Air Revitalization is a crucial system for any space travel, be it for Low Earth Orbit, such as the International Space Station, or for deep space transit. Current systems, such as the Carbon Dioxide Removal Apparatus aboard the ISS, require upkeep and maintenance, which cannot be done on long distance space missions. For the past several years, NASA has done research on Cryogenic systems for Carbon Dioxide removal. These systems operate on the fact that Carbon Dioxide freezes at a higher temperature than Oxygen and Nitrogen, so Carbon Dioxide can be frozen out of the cabin atmosphere without the use of filters, which degrade over time. To cool the cabin air down to a temperature where Carbon Dioxide freezes, Stirling cryocoolers have been used, which have shown promise in the hope of Carbon Dioxide deposition for Cabin Air Revitalization. Cryogenic systems are much more reliable but require significant energy input to operate. Physical systems, such as radiators, have generally not been used for this task, as there is a need to be able to “turn off” the rejection of heat to allow the frozen carbon dioxide to be collected. However, with working fluids pumped through a physical radiator, that aspect of operation can be achieved. The goal of this challenge is to determine the effectiveness of a variable conductance thermal radiator that can reject heat to deep space, without the use of a dedicated cryocooler to remove energy from the cabin air. The proposed design uses piping, hot and cold working fluids, and non-condensable gas to absorbl heat from the cabin air on one side of the radiator and reject the heat to deep space by means of thermal radiation. As well, the system will allow for the recovery of deposited Carbon Dioxide. The UNT X-HAB 2021 team will create a model radiator and test its performance with simulated heat sources and sinks and extrapolate those data points to analyze for real world conditions.

Travis Seaver↗

Gravitational Effects on Liquefaction Systems for Lunar and Mars Exploration

There is interest at NASA, other space agencies, and industry, in the liquefaction of fluids produced through in-situ processes on the surfaces of the Moon and Mars. A multi-center team at NASA recently considered multiple different refrigeration cycles and refrigeration integration methodologies and how these might fit into early liquefaction plants for NASA's exploration initiatives. The rate of liquefaction for these initiatives is quite slow in comparison to large scale terrestrial applications. These studies concluded that, for both structural and heat spreading reasons, integrating the refrigeration tubing on the surface of the storage tank wall is an attractive path to pursue in the near term. In order to develop a technology development path and inform investors, it was desired to investigate the sensitivity of gravity of the processes involved. An analysis of the condensation processes within the tank is performed. The objective is to determine the sensitivity of liquefaction to gravitational effects. The heat transfer mechanisms include forced convection heat removal to the refrigeration system (or cryocooler), conduction through the tank wall heat exchanger, and convection and condensation on the inner tank wall. Gravity affects the liquefaction process via condensate liquid drainage, natural convection in the ullage, and the shape of the liquid-vapor interface within the tank. Analysis of these mechanisms shows that while there is some sensitivity to gravitational level in general, within the bounds of current interest (rate of liquefaction appropriate to Lunar and Martian applications, and cooling capacity of the cryocooler), this sensitivity of liquefaction to gravity is quite small. Thus, system level testing on the Earth should suffice for the performance prediction and demonstration of liquefaction operations as applicable to Lunar and Martian applications.

ISRU↗

Static Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for A 1.4 MW Electric Machine in a Thermal Vacuum Chamber

NASA’s high efficiency megawatt motor (HEMM) is a partially superconducting, 1.4 MW electric machine designed for electrified aircraft propulsion. HEMM’s high performance is enabled by a field winding composed of 2nd generation high temperature superconducting (HTS) coils that are designed to operate at temperatures below 62 K. The superconducting rotor is conductively cooled to cryogenic temperatures using a rotating cryocooler embedded inside the machine’s shaft. This paper presents a static test of the full-scale superconducting rotor in a thermal vacuum chamber. The experimental setup is described in detail. Thermal and electromagnetic 3D finite element analyses of the experimental setup are shown along with a comparison of the model results to model results for HEMM. The thermal response during cool down from room temperature is discussed. Electrical measurements are presented for operation at different dc current excitations up to the rated current of the rotor (57.2 A) and temperature limit of the HEMM design (62 K). The results suggest that minor damage to one superconducting coil occurred at 50 A and 61.2 K, causing increased resistance in the system, but that the system could still be stably operated at 57.2 A and 62 K when conductively cooled by a cryocooler.

electrified aircraft propulsion↗

Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) activity has been investigating concepts for the liquefaction of cryogenic fluids produced on the surface of the Moon and Mars. Liquefaction testing of oxygen in a scaled lander tank using an integrated, industrial cryocooler system was completed. The testing covered the determination of the nominal performance operation of the system, constant liquefaction performance, and transient liquefaction performance. The goal of the testing was to demonstrate cryogenic liquefaction operational capabilities on the Lunar and Martian surfaces for landers and In Situ Resource Utilization. The testing met all key performance parameter threshold values including liquefaction rate (demonstrated 1.6 kg/hr compared to threshold of 1.1 kg/hr), number of variables as transient (goal of 3: liquefaction flow, environmental temperature, and cryocooler input power – all demonstrated), and number of fill levels (goal of 3: < 5%, 50%, and 90% - all demonstrated). Key testing results from oxygen liquefaction testing will be discussed including sensitivities provided by the analysis team.

Liquefaction↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The fullscale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

Comparison of Liquefaction Testing with Liquid Nitrogen and Liquid Oxygen

Liquid nitrogen is often used as a substitute for oxygen testing due to safety concerns, and the general similarity between their fluid properties. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, an opportunity arose to compare liquid nitrogen and liquid oxygen behavior using the same test hardware in similar test conditions. Comparative testing would verify whether the system response to nitrogen and oxygen would behave in a similar manner. Tests that were investigated include system boil-off heat load determination, autogenous pressurization, cryocooler loop initiation, and cryocooler loop operations. Results from testing are shown and compared to verify that liquid nitrogen and liquid oxygen tests yield similar system responses, and that nitrogen can be used as a substitute for oxygen in developmental tests at cryogenic temperatures.

Cryogenic Fluid Management↗

Thermal Design, Analysis, and Testing of a Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This presentation covers the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The full-scale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Thermal modeling and correlation with test data is presented identifying the areas of largest discrepancy. Opportunities to reduce the temperature gradient are identified.

electrified aircraft propulsion↗

Thermal Vacuum Testing of the Cryostat Heat Removal System for COSI SMEX

The Cryostat Heat Removal System (CHRS) of the Compton Spectrometer and Imager (COSI) consists of cryocooler, three transport aluminum ammonia Constant Conductance Heat Pipes (CCHP), three radiators with CCHP spreaders and Cryocooler Control Electronics (CCE) attached to a separate radiator. A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the integrated COSI CHRS in the flat configuration. This presentation summarizes the measured COSI CHRS performance along with lessons learned.

Pipes↗

Temperature Control Diagnostics for Sample Environments

In a scientific laboratory setting, standard equipment such as cryocoolers are often used as part of a custom sample environment system designed to regulate temperature over a wide range. The end user may be more concerned with precise sample temperature control than with base temperature. But cryogenic systems tend to be specified mainly in terms of cooling capacity and base temperature. Technical staff at scientific user facilities (and perhaps elsewhere) often wonder how to best specify and evaluate temperature control capabilities. Here we describe test methods and give results obtained at a user facility that operates a large sample environment inventory. Although this inventory includes a wide variety of temperature, pressure, and magnetic field devices, the present work focuses on cryocooler-based systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Twin-Screw D-2 Extruder for the ITER Pellet Injection System

A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. The extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with single-stage gas gun into the plasma. A one-fifth ITER scale prototype extruder has been built to produce a continuous solid deuterium extrusion. Deuterium gas is precooled and liquefied before being introduced into the extruder. The precooler consists of a copper vessel containing liquid nitrogen surrounded by a deuterium gas filled copper coil. The liquefier is comprised of a copper cylinder connected to a Cryomech AL330 cryocooler, which is surrounded by a copper coil that the precooled deuterium flows through. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at approximate to 15 K) before it is forced through the extruder nozzle. A viewport located below the extruder nozzle provides a direct view of the extrusion. A camera is used to document the extrusion quality and duration. A data acquisition system records the extruder temperatures, torque, and speed, upstream, and downstream pressures. This paper will describe the prototype twin-screw extruder and initial extrusion results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Compatible Microfluidic platforms for screening, Crystallization and De Novo Structure Determination of Proteins

We present here an X-ray compatible, array based microfluidic chip that functions as a complete crystallization platform. It is capable of screening multiple crystallization conditions using minimal amount of protein solution per trial and facilitates de novo structure determination by collecting and merging X-ray data from multiple crystals grown on-chip. Our approach bypasses issues associated with the need to grow large, high quality crystals, crystal damage during handling, cryocooling, and radiation exposure and enables in situ data collection at biologically relevant temperatures. To validate the method, we determined the structure of PhnA to 2.30{angstrom} resolution solely using data collected on-chip. Here we have presented a microfluidic platform that allows for screening of crystallization conditions, together with on-chip X-ray analysis of the crystals formed. Not only do these chips eliminate crystal handling, they also allow for room temperature data collection from multiple small crystals, as opposed to collecting data from single large crystals, which requires cryocooling to avoid radiation damage. Efforts on extending the capabilities of this platform to perform a variety of other studies on different novel protein targets are currently underway.

59 BASIC BIOLOGICAL SCIENCES↗

Twin-Screw Extruder Development for the ITER Pellet Injection System

The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pellets used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ≈5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ≈15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.

Meitner, Steven J↗

Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity

Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

magnetic refrigeration↗

A multi-layered SRF cavity for conduction cooling applications

Industrial application of SRF technology would favor the use of cryocoolers to conductively cool SRF cavities for particle accelerators, operating at or above 4.3 K. In order to achieve a lower surface resistance than Nb at 4.3 K, a superconductor with higher critical temperature should be used, whereas a metal with higher thermal conductivity than Nb should be used to conduct the heat to the cryocoolers. A standard 1.5 GHz bulk Nb single-cell cavity has been coated with a ~2 µm thick layer of Nb3Sn on the inner surface and with a 5 mm thick Cu layer on the outer surface for conduction cooled applications. The cavity performance has been measured at 4.3 K and 2.0 K in liquid He. The cavity reached a peak surface magnetic field of ~40 mT with a quality factor of 6×109 and 3.5×109 at 4.3 K, before and after applying the thick Cu layer, respectively.

Ciovati, G.↗

Evaluation of low heat conductivity rf cables

New potential applications of superconducting radio-frequency can be envisioned with conduction cooling of the cavities using cryocoolers. In this case, the total heat load to the cryocoolers have to be carefully managed to assure sufficient margin to operate the cavity at an acceptable accelerating gradient. The static and dynamic heat load from rf cables connected to the cavity can be a significant contribution to the total heat load. In this contribution we report the results from measurements of the temperature profile at 1.3 GHz for two low heat conductivity rf cables, as a function of the rf power and with one end of the cable in thermal contact with a liquid helium bath at 4.3 K. A parametric model of the two cables was developed with ANSYS to match the temperature profiles and calculate the heat load at the cold end of the cable.

Cheng, G.↗