Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

CSEM, BHP, Salinity, Flow-Rate, Fiber, and Tilt Data Collected in Jan. 2022 for Proj. DE-FE0031785

This dataset consists of four directories: first directory named as EM for the controlled source electromagnetic (CSEM) survey data that are zipped per day for January 18-21, 22, 23, 24, 25, 26, 27, 28, 29, 30, and 31, 2022; second directory named as "Fiber" for the fiber optic slow-strain and microseismic data that are zipped per well; the third file that contains bottomhole pressure (BHP) and salinity and pump flow rate data during the CSEM surveys; and the fourth file that contained tiltmeter data.

CSEM↗

A glimpse of stars the size of dust particles

The Nuclear Imaging System (NIS) is an important diagnostic tool used to study nuclear fusion implosions at a research facility in California. There a capsule the size of a flea is compressed until it reaches the size of a speck of dust. As the capsule collapses on itself and ignites under extreme temperature and pressure, NIS detects particles emitted from that process at a scale that would correspond to watching a 32-inch TV screen from 100 miles away. My work involves taking snapshots of one of the most minuscule, fleeting and amazing experiments on Earth in order to ensure the safety and reliability of the US nuclear stockpile and get closer to developing a new form of clean energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submillimeter-wave antennas on thin membranes

Submillimeter-wave antennas have been fabricated on 1-micron thick silicon-oxynitride membranes. This approach results in better patterns than previous lens-coupled antennas, and eliminates the dielectric loss associated with the substrate lens. Measurements on a wideband log-periodic antenna at 700 GHz, 370 GHz and 167 GHz show no sidelobes and 3-dB beamwidths between 40 and 60 deg. A linear imaging array has similar patterns at 700 GHz. Possible applications for membrane antennas include wideband superconducting tunnel-junction receivers for radio astronomy and imaging arrays for radiometry and plasma diagnostics.

Rebeiz, Gabriel M.↗

Nonparametric statistical modeling of binary star separations

We develop a comprehensive statistical model for the distribution of observed separations in binary star systems, in terms of distributions of orbital elements, projection effects, and distances to systems. We use this model to derive several diagnostics for estimating the completeness of imaging searches for stellar companions, and the underlying stellar multiplicities. In application to recent imaging searches for low-luminosity companions to nearby M dwarf stars, and for companions to young stars in nearby star-forming regions, our analyses reveal substantial uncertainty in estimates of stellar multiplicity. For binary stars with late-type dwarf companions, semimajor axes appear to be distributed approximately as a(exp -1) for values ranging from about one to several thousand astronomical units. About one-quarter of the companions to field F and G dwarf stars have semimajor axes less than 1 AU, and about 15% lie beyond 1000 AU. The geometric efficiency (fraction of companions imaged onto the detector) of imaging searches is nearly independent of distances to program stars and orbital eccentricities, and varies only slowly with detector spatial limitations.

Heacox, William D.↗

Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

Parabolic Flight↗

PLIF Study of Mars Science Laboratory Capsule Reaction Control System Jets

Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to visualize the flow in the wake of a Mars Science Lab (MSL) entry capsule with activated reaction control system (RCS) jets in NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Images were processed using the Virtual Diagnostics Interface (ViDI) method, which brings out the three-dimensional nature of the flow visualization data while showing the relative location of the data with respect to the model. Comparison of wind-on and wind-off results illustrates the effect that the hypersonic crossflow has on the trajectory and structure of individual RCS jets. The visualization and comparison of both single and multiple activated RCS jets indicate low levels of jet-jet interaction. Quantitative streamwise velocity was also obtained via NO PLIF molecular tagging velocimetry (MTV).

Johansen, C. T.↗

The Goes-R Geostationary Lightning Mapper (GLM)

The Geostationary Operational Environmental Satellite (GOES-R) is the next series to follow the existing GOES system currently operating over the Western Hemisphere. Superior spacecraft and instrument technology will support expanded detection of environmental phenomena, resulting in more timely and accurate forecasts and warnings. Advancements over current GOES capabilities include a new capability for total lightning detection (cloud and cloud-to-ground flashes) from the Geostationary Lightning Mapper (GLM), and improved storm diagnostic capability with the Advanced Baseline Imager. The GLM will map total lightning activity (in-cloud and cloud-to-ground lighting flashes) continuously day and night with near-uniform spatial resolution of 8 km with a product refresh rate of less than 20 sec over the Americas and adjacent oceanic regions. This will aid in forecasting severe storms and tornado activity, and convective weather impacts on aviation safety and efficiency. In parallel with the instrument development, a GOES-R Risk Reduction Team and Algorithm Working Group Lightning Applications Team have begun to develop the Level 2 algorithms, cal/val performance monitoring tools, and new applications. Proxy total lightning data from the NASA Lightning Imaging Sensor on the Tropical Rainfall Measuring Mission (TRMM) satellite and regional test beds are being used to develop the pre-launch algorithms and applications, and also improve our knowledge of thunderstorm initiation and evolution. In this paper we will report on new Nowcasting and storm warning applications being developed and evaluated at various NOAA Testbeds.

Goodman, Steven J.↗

NO PLIF Visualizations of the Orion Capsule in LENS-I

Planar laser-induced fluorescence (PLIF) of nitric oxide (NO) was used to visualize the interaction of reaction-control-system (RCS) jet flows in the wake of a hypersonic capsule reentry vehicle. The tests were performed at the Calspan University at Buffalo Research Center's (CUBRC) LENS-I reflected shock tunnel facility. This was the first application of PLIF to study RCS jets in a large-scale pulsed hypersonic facility. The LENS-I facility allowed RCS jet flows to be studied while varying the flow enthalpy, Reynolds number, angle of attack and jet configuration. The interaction of pitch and roll jets with the flowfield was investigated. Additionally, thin film sensors were used to monitor heat transfer on the surface of the model to detect any localized heating resulting from the firing of the RCS jets. Tests were conducted with the model held at angles of attack of 18deg and 22deg. The nominal Mach number in all tests was 8, while Reynolds number based on model diameter ranged from 2.2x10(exp 6) - 1.5x10(exp 7). Images were processed using the Virtual Diagnostics Interface (ViDI) system developed at NASA Langley Research Center to provide a three-dimensional display of the experimental data.

Combs, C.↗

PLIF Study of Mars Science Laboratory Capsule Reaction Control System Jets

Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to visualize the flow in the wake of a Mars Science Lab (MSL) entry capsule with activated reaction control system (RCS) jets in NASA Langley Research Center's 31-Inch Mach 10 Air Tunnel facility. Images were processed using the Virtual Diagnostics Interface (ViDI) method, which brings out the three-dimensional nature of the flow visualization data while showing the relative location of the data with respect to the model. Comparison of wind-on and wind-off results illustrates the effect that the hypersonic crossflow has on the trajectory and structure of individual RCS jets. The visualization and comparison of both single and multiple activated RCS jets indicate low levels of jet-jet interaction. Quantitative streamwise velocity was also obtained via NO PLIF molecular tagging velocimetry (MTV).

Johansen, C. T.↗

Understanding Heating in Active Region Cores through Machine Learning. I. Numerical Modeling and Predicted Observables

To adequately constrain the frequency of energy deposition in active region cores in the solar corona, systematic comparisons between detailed models and observational data are needed. In this paper, we describe a pipeline for forward modeling active region emission using magnetic field extrapolations and field-aligned hydrodynamic models. We use this pipeline to predict time-dependent emission from active region NOAA 1158 for low-, intermediate-, and high-frequency nanoflares. In each pixel of our predicted multi-wavelength, time-dependent images, we compute two commonly used diagnostics: the emission measure slope and the time lag. We find that signatures of the heating frequency persist in both of these diagnostics. In particular, our results show that the distribution of emission measure slopes narrows and the mean decreases with decreasing heating frequency and that the range of emission measure slopes is consistent with past observational and modeling work. Furthermore, we find that the time lag becomes increasingly spatially coherent with decreasing heating frequency while the distribution of time lags across the whole active region becomes more broad with increasing heating frequency. In a follow-up paper, we train a random forest classifier on these predicted diagnostics and use this model to classify real observations of NOAA 1158 in terms of the underlying heating frequency.

UV radiation↗

Understanding asymmetries using integrated simulations of capsule implosions in low gas-fill hohlraums at the National Ignition Facility

Current capsule implosions at the National Ignition Facility (NIF) using high-density-carbon ablators and laser energies close to 2 MJ have shown neutron yields in excess of 50 kJ. Improving on this performance requires understanding of the different degradation mechanisms. For many NIF implosions, nuclear diagnostic signatures have inferred residual hot-spot velocities that correlate with fuel areal density variations consistent with a low-order mode-1 asymmetry. A current working hypothesis attributes these asymmetries to a combination of beam to beam variations in the laser delivery and possibly coupling to target features, such as the diagnostic holes needed for x-ray imaging. Recently, a new source has been identified, thickness variation in the ablator shell. To gain better understanding and eventually mitigate the causes of <ρR> asymmetries, 3D integrated simulations using the actual delivered laser powers are needed. To capture the effect of the diagnostic holes (DHs) using direct numerical simulation would require significantly large computational resources. Instead, our 3D simulations make use of a subgrid model developed using highly-resolved 2D simulations that include several details of the DH engineering complexity. Simulations of NIF shots using hohlraums without DHs, to isolate the effect of beam-to-beam variations, reproduce fairly well the observed nuclear diagnostic signatures. Similarly, reasonable agreement between data and simulations is also obtained in the presence of diagnostic holes. To account for the remaining discrepancies a sensitivity study of ablator thickness variation showed that 1% thickness asymmetries are comparable in effect to 1% peak drive mode-1 asymmetries. Furthermore, this study identified sensitivity to variations in the imbedded doped layer (needed to shield the DT ice from the high energy x-rays generated in the hohlraum) thickness even when the inner and outer surface of the ablator are perfectly spherical.

radiation hydrodynamics↗

Applying queueing theory to evaluate wait-time-savings of triage algorithms

Abstract In the past decade, artificial intelligence (AI) algorithms have made promising impacts in many areas of healthcare. One application is AI-enabled prioritization software known as computer-aided triage and notification (CADt). This type of software as a medical device is intended to prioritize reviews of radiological images with time-sensitive findings, thus shortening the waiting time for patients with these findings. While many CADt devices have been deployed into clinical workflows and have been shown to improve patient treatment and clinical outcomes, quantitative methods to evaluate the wait-time-savings from their deployment are not yet available. In this paper, we apply queueing theory methods to evaluate the wait-time-savings of a CADt by calculating the average waiting time per patient image without and with a CADt device being deployed. We study two workflow models with one or multiple radiologists (servers) for a range of AI diagnostic performances, radiologist’s reading rates, and patient image (customer) arrival rates. To evaluate the time-saving performance of a CADt, we use the difference in the mean waiting time between the diseased patient images in the with-CADt scenario and that in the without-CADt scenario as our performance metric. As part of this effort, we have developed and also share a software tool to simulate the radiology workflow around medical image interpretation, to verify theoretical results, and to provide confidence intervals for the performance metric we defined. We show quantitatively that a CADt triage device is more effective in a busy, short-staffed reading setting, which is consistent with our clinical intuition and simulation results. Although this work is motivated by the need for evaluating CADt devices, the evaluation methodology presented in this paper can be applied to assess the time-saving performance of other types of algorithms that prioritize a subset of customers based on binary outputs.

Thompson, Yee Lam Elim (ORCID:0000000196537707)↗

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]↗

Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system

An Electron Cyclotron Emission Imaging (ECEI) system has been developed on the J-TEXT tokamak and employed for the multi-dimensional electron temperature fluctuation imaging measurement in 2019 campaign. The intelligent control module has been developed and been used to flexibly setup the 256-channel ECEI system configurations for different plasma scenarios. The adjustments of key parameters are merged in this module including size and position of the geometric observation window, and the dynamic range of the signal and image resolution. The user-friendly interface is also developed for the tokamak operator to set the ECEI system focusing on physics interested region. Furthermore, this module is installed close to the diagnostic system around the J-TEXT tokamak, which can be remotely controlled by authorized operators in the control room. It significantly improves ECEI flexibility and stability, and also keeps the operation technician away from the harsh radiation environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

Machine-Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Application in Experimental Facilities

Real-time monitoring of combustion behavior is a crucial step toward actively controlled rotating detonation engine (RDE) operation in laboratory and industrial environments. Various machine learning methods have been developed to advance diagnostic efficiencies from conventional postprocessing efforts to real-time methods. Here this work evaluates and compares conventional techniques alongside convolutional neural network (CNN) architectures trained in previous studies, including image classification, object detection, and time series classification, according to metrics affecting diagnostic feasibility, external applicability, and performance. Real-time, capable diagnostics are deployed and evaluated using an altered experimental setup. Image-based CNNs are applied to externally provided images to approximate dataset restrictions. Image classification using high-speed chemiluminescence images and time series classification using high-speed flame ionization and pressure measurements achieve classification speeds enabling real-time diagnostic capabilities, averaging laboratory-deployed diagnostic feedback rates of 4–5 Hz. Object detection achieves the most refined resolution of 20 μs in postprocessing. Image and time series classification require the additional correlation of sensor data, extending their time-step resolutions to 80 ms. Comparisons show that no single diagnostic approach outperforms its competitors across all metrics. This finding justifies the need for a machine learning portfolio containing a host of networks to address specific needs throughout the RDE research community.

33 ADVANCED PROPULSION SYSTEMS↗