Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Models for Single–Site Heterogeneous Catalysts on Carbon: MoO 2 Epoxidation Catalyst Anchored to a Fullerene

Single-site molybdenum dioxo catalysts, fullerenol/MoO 2 , are prepared via grafting precursor (DME)MoO 2 Cl 2 onto a highly polyhydroxylated fullerene (ful) and an isomerically-pure and well-defined fullerene (ful*). These catalyst structures are characterized by ICP-OES, XPS, XANES, EXAFS, DRIFT, Raman, and NMR spectroscopy, and DFT. Mo 3d 5/2 XPS and Mo K-edge XANES assign the oxidation state as Mo(VI). Mo EXAFS data fitting reveals two Mo=O double and two Mo–O single bonds at distances of 1.7 and 1.9 Å, respectively, while an Mo=O stretchingl mode is observed at ~950 cm –1 by DRIFT and Raman spectroscopy. These data align well with DFT computational results, supporting the proposed catalyst structure as Fullerene(-μ-O-) 2 M(=O) 2 . Additionally, DFT provides insight into the energetically favorable grafting sites for an isomerically pure fullerenol. The scope of fullerenol/MoO 2 mediated alkene epoxidation includes abiotic alkenes, natural occurring terpenes, and conjugated olefins. For cyclooctene the rate law is first-order in [Mo], near first order in [olefin] and zero-order in [t-butyl hydroperoxide]. A plausible reaction mechanism involves peroxide addition first and then cyclooctene addition directly across the peroxo bond forming the epoxide product, consistent with DFT computation. Overall, fullerenol/MoO 2 shows promise as a sustainable and structurally well-defined system with versatile catalytic activity and good epoxidation recyclability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polymer Size–Catalytic Activity Relationships in Solution by Fluorescence Correlation Spectroscopy

Measuring the catalytic activity of specific sizes of polymers with active catalysts in solution is typically challenging, due to limited instrument detection sensitivity and/or dynamic range. Here, a fluorescence correlation spectroscopy (FCS) method is developed to determine the catalytic activity of living polymers of a specific apparent size in solution. Deviation from a single-component FCS data fitting, as assessed by χ2, is also introduced and developed as a “speciation index”—a method to evaluate and track changes in the relative amount of distinct polymer sizes with reaction progress. These methods are enabled by incorporating a selectively reactive fluorescent monomer into growing polydicyclopentadiene or polynorbornene during ring-opening metathesis polymerization (ROMP). Compared to polynorbornene, data showed that catalysts in aggregates of polyDCPD retained higher activity for longer—outcomes not directly inferable from simple diffusional-access predictions. Here, the ability to assign catalytic activity to polymers of specific sizes, and then to determine how this activity evolves with reaction progress, support long-term goals in the development and measurement of nano-objects that possess size-dependent catalytic activity.

Active catalyst↗

Carbon‐13 Hyperpolarization of α‐Ketocarboxylates with Parahydrogen in Reversible Exchange

Abstract Signal Amplification by Reversible Exchange (SABRE) is a relatively simple and fast hyperpolarization technique that has been used to hyperpolarize the α‐ketocarboxylate pyruvate, a central metabolite and the leading hyperpolarized MRI contrast agent. In this work, we show that SABRE can readily be extended to hyperpolarize 13 C nuclei at natural abundance on many other α‐ketocarboxylates. Hyperpolarization is observed and optimized on pyruvate (P 13C =17 %) and 2‐oxobutyrate (P 13C =25 %) with alkyl chains in the R‐group, oxaloacetate (P 13C =11 %) and alpha‐ketoglutarate (P 13C =13 %) with carboxylate moieties in the R group, and phenylpyruvate (P 13C =2 %) and phenylglyoxylate (P 13C =2 %) with phenyl rings in the R‐group. New catalytically active SABRE binding motifs of the substrates to the hyperpolarization transfer catalyst – particularly for oxaloacetate – are observed. We experimentally explore the connection between temperature and exchange rates for all of these SABRE systems and develop a theoretical kinetic model, which is used to fit the hyperpolarization build‐up and decay during SABRE activity.

McBride, Stephen J. [Department of Chemistry North↗

Improved Kelbg Potentials for Z > 1 and Application to Carbon Plasmas

In this work, we present a general form for the electron‐ion diffractive potential derived from the quantum pair density matrix and fit to the improved Kelbg potential for atomic numbers up to $Z = 54$. We apply classical molecular dynamics using the improved Kelbg potential for carbon with various forms of the Pauli potential to compute internal energies and pressures for hot, dense plasma conditions. Our results are compared to an equation of state model based on path integral Monte Carlo and density functional theory simulations to examine the extent to which the improved Kelbg potential reproduces the internal energy and pressure of carbon plasmas. The regions of validity for carbon agree generally with those derived previously for hydrogen once pressure ionization effects are incorporated. Based on our carbon results and previously published hydrogen studies, we discuss the general applicability and limitations of these potentials for equation of state studies in warm dense matter and high energy density plasmas.

general physics↗

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Human–mouse comparison of the multistage nature of radiation carcinogenesis in a mathematical model

Abstract Mouse models are vital for assessing risk from environmental carcinogens, including ionizing radiation, yet the interspecies difference in the dose response precludes direct application of experimental evidence to humans. Herein, we take a mathematical approach to delineate the mechanism underlying the human–mouse difference in radiation‐related cancer risk. We used a multistage carcinogenesis model assuming a mutational action of radiation to analyze previous data on cancer mortality in the Japanese atomic bomb survivors and in lifespan mouse experiments. Theoretically, the model predicted that exposure will chronologically shift the age‐related increase in cancer risk forward by a period corresponding to the time in which the spontaneous mutational process generates the same mutational burden as that the exposure generates. This model appropriately fitted both human and mouse data and suggested a linear dose response for the time shift. The effect per dose decreased with increasing age at exposure similarly between humans and mice on a per‐lifespan basis (0.72‐ and 0.71‐fold, respectively, for every tenth lifetime). The time shift per dose was larger by two orders of magnitude in humans (7.8 and 0.046 years per Gy for humans and mice, respectively, when exposed at ~35% of their lifetime). The difference was mostly explained by the two orders of magnitude difference in spontaneous somatic mutation rates between the species plus the species‐independent radiation‐induced mutation rate. Thus, the findings delineate the mechanism underlying the interspecies difference in radiation‐associated cancer mortality and may lead to the use of experimental evidence for risk prediction in humans.

Oncology↗

Anion Binding by Macrocyclic Receptors: Computational Landscape of 1:1 and 2:1 Stoichiometries

Macrocyclic receptors play a crucial role in supramolecular chemistry, enabling the selective binding of guest molecules through non-covalent interactions. This study investigates the anion binding properties of three shape-persistent macrocycles, triazolophane, cyanostar, and tricarb, each featuring preorganized cavities with polarized CH hydrogen bond donors. In the 1:1 binding stoichiometries, the macrocycles preferentially bind anions that fit inside their two-dimensional cavities, with this preference being more pronounced in solution. Specifically, the triazolophane favors smaller anions like chloride and bromide, while the larger cavities offered by cyanostar and tricarb macrocycles preferentially bind the larger iodide. For large, polyatomic anions (SCN − , BF$^{−}_{4}$, ClO$^{−}_{4}$, and PF$^{−}_{6}$), the macrocycles self-assemble to form stable 2:1 sandwich complexes, exhibiting stronger binding. This shift in selectivity highlights the versatility of the macrocycles, making them promising candidates for anion sensing and regulation with various complexation stoichiometries.

Che, Minwei [Indiana University, Bloomington, IN (↗

Angle-Resolved Polarized Raman Study of Layered Cr 2 Se 3

The polarization-resolved Raman spectra of two-dimensional Cr 2 Se 3 synthesized via chemical vapor deposition (CVD) and chemical vapor transport (CVT) techniques were investigated in detail. The samples were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). A distinct polarization dependence was observed in the Raman intensity of all the Cr-Cr, Cr-Se, and Se-Se modes in both samples. The observed angle-dependent Raman intensities of each peak could be related to the crystal structure-specific Raman tensor. XRD results of the bulk Cr 2 Se 3 sample synthesized via CVT confirm its trigonal crystal structure, and the Raman peaks can be fitted using the Raman tensors for the A g and E g modes for both the parallel and crossed polarizations. However, for the Cr 2 Se 3 samples directly grown on Si/SiO 2 substrates by CVD, it was necessary to assume the triclinic crystal structure in order to explain the polarized Raman dependence of all the peaks in both parallel and crossed polarization directions. Furthermore, this is the first experimental result suggesting the existence of triclinic Cr 2 Se 3 crystal structure, which has been theoretically predicted in the Materials Project database.

36 MATERIALS SCIENCE↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Layers Can Be Deceiving: A Hopping Model for Small Molecule Diffusion in TATB Crystal

Sorption of small molecule gases in materials can play a significant role in their long‐term stability and compatibility within multi‐material assemblies. While many material properties of the insensitive high explosive TATB (1,3,5‐triamino‐2,4,6‐trinitrobenzene) are well understood, very little is known regarding its permeability to gases. TATB crystal exhibits a graphitic‐like layered packing structure that evokes a mental schema in which the layers form nanoscopic channels, but it is unclear whether this structure promotes gas transport. Here, we use molecular dynamics (MD) simulations to predict transport of small molecules through TATB single crystal. An approach to fit classical force fields is developed to model TATB interactions with H 2 O, He, Ne, and Ar, which is then combined with steered MD to probe gas transport along selected directions in the crystal. We find that small molecule transport occurs via a hopping mechanism that exhibits distinct jumps between interstitial sites and is substantially faster normal to the layers as compared to through them. This result stems from the finding that intralayer junctions between adjacent TATB molecules are the most stable interstitial sites and that energetic barriers are lower for hopping between adjacent layers. An empirical model for diffusion rate based on the MD data shows that the rate decays exponentially with increasing molecular radius and is negligibly small for all molecules larger than He, including common atmospheric gases. These findings have implications for the interpretation of experiments that measure surface area, material response to extreme conditions, and are expected to help constrain models for material aging.

36 MATERIALS SCIENCE↗

Uncertainty Quantification Enabled by Automatic Differentiation for Hydrodynamic Simulation of Shock‐to‐Detonation Transition in High Explosives

Quantifying the effects of uncertainty in a reactive burn model on the run-to-detonation time in high explosives (HEs) provides a robust methodology for assessing the probability of an HE failing the IHE qualification standard. Moreover, uncertainty quantification helps evaluate whether the model calibration accurately represents data outside the calibration set. This study uses a specialized hydrodynamic simulation code for modeling detonation to determine the run-to-detonation time of the HE PBX 9502 for various impact velocities. To quickly approximate uncertainties in the model, a surrogate was constructed using a Taylor series expansion centered at the mean of the input parameters. To obtain the sensitivities required for constructing the Taylor series, HYP-percomplex Automatic Differentiation (HYPAD) was implemented. HYPAD is a methodology for infusing existing codes with automatic differentiation capabilities by augmenting variables with one or more imaginary units to compute step-size independent partial derivatives. These derivatives are accurate to machine precision with respect to the implemented numerical algorithm, meaning their accuracy reflects that of the underlying method (e.g., integration or discretization schemes). Using reduced order modeling techniques, the mean and standard deviation of the run-to-detonation time of a shock within PBX 9502 were computed for a number of initial impact velocities. A weighted least squares regression was then performed to obtain a best fit curve and prediction interval for the computed statistics. Historical data points from explosively driven wedge tests were utilized to validate the prediction interval, ensuring its reliability in predicting future outcomes. With this prediction interval and a known safety constraint curve, the most probable point of failure and the probability of failure for the HE PBX 9502 were determined.

97 MATHEMATICS AND COMPUTING↗

Effect of Sample Mass, Confinement, and Preheating Time on the Thermal Response of LLM‐105: Experiments and Kinetic Analysis

Various small-scale experiments were performed to provide data for developing a model to predict the thermal response of LLM-105 over a wide range of conditions. The thermal decomposition of LLM-105 was studied as a function of sample mass, confinement of volatile products, and preheating time in both isothermal and ramped heating experiments. The thermal decomposition of LLM-105 is a two-step process, as shown by the two exothermic peaks in the heat flow profiles, which were fitted to two nth-order autocatalytic reaction models with a similar activation energy of ∼289 kJ/mol. The magnitude and shape of these peaks varied with sample mass and confinement. Increasing sample mass enhanced the second exotherm with respect to the first one, while increasing the level of confinement promoted a transition from a sublimation-dominated regime towards thermal decomposition. The effect of LLM-105 particle size on the rate of weight loss was evident for open-pan experiments, where bigger particles sublimed at lower temperatures than smaller particles. Thermal response and solid residue composition of LLM-105 samples were analyzed following preheating for different durations. Longer preheating times caused a shift of the second exotherm to lower temperatures and a decrease in the reaction enthalpy, confirming that LLM-105 decay is a consecutive reaction mechanism, probably autocatalytic. In conclusion, the kinetic model derived from ramped experiments was validated against the measured LLM-105 fraction remaining and the enthalpy remaining of the solid residue as a function of preheating times and showed good agreement.

Chemistry - Chemical explosives↗

Bayesian D‐Optimal Designs for Gaussian Process Surrogate Models

Computer experiments often employ space-filling strategies to create surrogate models with strong predictive performance. The impact of model parameter estimation for Gaussian process surrogates, however, is often overlooked. Obtaining a better initial estimate of the covariance lengthscale parameter, θ, can greatly improve the resulting Gaussian process fit through more effective sequential acquisitions during active learning. In this work, we propose a novel initial design maximizing the Bayesian D-optimality criterion of the Gaussian process lengthscale parameter. Previously published results have shown the emphasis on lengthscale estimation to be promising, but relied on an empirically driven design creation process. Our Bayesian D-optimal designs are rooted in information theory and lead to more informative sequential acquisitions by improving lengthscale estimation. In many cases, these gains eventually result in better surrogates than those seeded with space-filling initial designs. Furthermore, Bayesian D-optimal designs can be tailored to either isotropic or anisotropic covariance structures, and the Bayesian framework enables the inclusion of prior knowledge in the design process, offering greater flexibility and adaptability. Through several simulation studies, we demonstrate the advantages of Bayesian D-optimal designs in terms of both lengthscale estimation accuracy and predictive performance during active learning.

Bayesian experimental design↗

Efficient Simulation of Open Quantum Systems on NISQ Trapped‐Ion Hardware

Abstract Simulating open quantum systems, which interact with external environments, presents significant challenges on noisy intermediate‐scale quantum (NISQ) devices due to limited qubit resources and noise. In this study, an efficient framework is proposed for simulating open quantum systems on NISQ hardware by leveraging a time‐perturbative Kraus operator representation of the system's dynamics. This approach avoids the computationally expensive Trotterization method and exploits the Lindblad master equation to represent time evolution in a compact form, particularly for systems satisfying specific commutation relations. The efficiency of this method is demonstrated by simulating quantum channels, such as the continuous‐time Pauli channel and damped harmonic oscillators, on NISQ trapped‐ion hardware, including IonQ Harmony and Quantinuum H1‐1. Additionally, hardware‐agnostic error mitigation techniques are introduced, including Pauli channel fitting and quantum depolarizing channel inversion, to enhance the fidelity of quantum simulations. These results show strong agreement between the simulations on real quantum hardware and exact solutions, highlighting the potential of Kraus‐based methods for scalable and accurate simulation of open quantum systems on NISQ devices. This framework opens pathways for simulating more complex systems under realistic conditions in the near term.

Burdine, Colin [Department of Electrical and Compu↗

Surface analysis insight note: Illustrating the effect of adventitious contamination on Pt photoemission peak intensities

Adventitious carbon contaminations are not only omnipresent and used for charge referencing of XPS spectra but also can alter the apparent presence of the element peaks that span over the large spectral window of binding energies. This Insight note describes the effect of an adventitious contamination layer on Pt and presents, in brief, the approach whereby the component spectra are derived for ion beam cleaned Pt samples that can then utilize linear mathematics to peak fit said spectra thus quantifying the amount of each component including that assigned to the contamination itself of Pt metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface science insight note: A linear algebraic approach to elucidate native films on Fe 3 O 4 surface

Standard materials are often used to obtain spectra that can be compared to those from unknown samples. Spectra measured from these known substances are also used as a means of computing sensitivity factors to allow quantification by X-ray photoelectron spectroscopy (XPS) of less well-defined materials. Spectra from known materials also provide line shapes suitable for inclusion in spectral models which, when fitted to spectra, permit the chemical state for a sample to be assessed. Both types of information depend on isolating photoemission signals from the inelastically scattered signal. In this Insight note, technical issues associated with the use of XPS of as received Fe 3 O 4 powder sample surface are discussed. The Insight note is designed to show how linear algebraic techniques applied to data collected from a sample marketed as pure Fe 3 O 4 powder are used to verify that XPS has been performed on chemistry representative of the sample. The methods described in this Insight note can further be utilized in elucidating complex XPS data obtained from thin films formed or evolved during cyclic/non-steady use of complex (electro)catalyst surfaces, especially in the presence of contaminants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Entropic Constraints on the Thermodynamics of Molecular Adsorption in Nano‐Porous Materials

Abstract Gas separation is a critical industrial process that consumes a significant amount of energy due to the widely used techniques that are currently employed. Adsorptive materials—such as metal–organic frameworks (MOFs)—show promise as an energy‐efficient alternative. Of particular current interest are novel, temperature‐dependent separation processes in MOFs, such as the recently reported separation of ternary isomeric hydrocarbon mixtures within one and the same material. However, the mechanisms of these highly desirable separations remain poorly understood. Herein, through a combination of ab initio simulations and statistical mechanics, it is shown that the temperature dependence is the result of a constraint on the guest molecule's entropic degrees of freedom when loaded into the MOF, caused by the fortuitous tight fitting of the guest inside the pore. While the framework applies to all molecular adsorption in porous media, it is essential for the description of large molecules in small pores, which is demonstrated here using the separation of C6 isomers in Ca(H 2 tcpb) as a test case. The developed framework and analysis not only reveal the reason why separation occurs but also predict the temperatures at which it takes place, thus opening the door to newly designed MOFs with tailor‐made precision.

Chemistry↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗