Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Power RF Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Electron beam coupling to a metamaterial structure

Microwave metamaterials have shown promise in numerous applications, ranging from strip lines and antennas to metamaterial-based electron beam driven devices. In general, metamaterials allow microwave designers to obtain electromagnetic characteristics not typically available in nature. High Power Microwave (HPM) sources have in the past drawn inspiration from work done in the conventional microwave source community. In this article, the use of metamaterials in an HPM application is considered by using an effective medium model to determine the coupling of an electron beam to a metamaterial structure in a geometry similar to that of a dielectric Cerenkov maser. Use of the effective medium model allows for the analysis of a wide range of parameter space, including the “mu-negative,”“epsilon-negative,” and “double negative” regimes of the metamaterial. The physics of such a system are modeled analytically and by utilizing the particle-in-cell code ICEPIC. For this geometry and effective medium representation, optimum coupling of the electron beam to the metamaterial, and thus the optimum microwave or RF production, occurs in the epsilon negative regime of the metamaterial. Given that HPM tubes have been proposed that utilize a metamaterial, this model provides a rapid method of characterizing a source geometry that can be used to quickly understand the basic physics of such an HPM device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

Development of 50kV air-core transformer for electron gun static power source of 3MeV DC accelerator

A 3 MeV, 10 mA DC Electron Beam Accelerator based on the capacitively coupled parallel-fed voltage multiplier in 6 kg/cm{sup 2} SF{sub 6} gas environment is under commissioning at Electron Beam Centre, Kharghar, Navi Mumbai. Electron Gun is situated at -3 MV terminal which requires a constant power for its anode and filament. Gun power source has been derived by suitably coupling the ac components present in the HV Multiplier column. An aircore step down transformer rated for 50kV/600V/120kHz floating at 3 MV to extract the required power for electron gun from high voltage column has been developed. The transformer has been operated for 7 kW, 1 MeV of electron beam in 6 kg/cm{sup 2} nitrogen gas environment. The paper describes briefly about the design aspects and test results. (author)

43 PARTICLE ACCELERATORS↗

Collaboration with NSTX in Calculations of Radiofrequency and Neutral Beam Heating and Current Drive

The overall objective of this project was to advance the understanding of heating and current drive necessary for toroidal magnetic confinement fusion energy reactors, and to provide accurate models for these sources to aid in understanding magneto-hydrodynamic, transport and boundary physics issues. Increased understanding is provided by computer simulation using the underlying physics laws, and will lead to greater reliability and increased efficiency of a power producing fusion reactor. The proposed work entailed applications of existing CompX Fokker-Planck, ray tracing, full-wave microwave, and particle diffusion calculator codes to the National Spherical Torus Experiment at Princeton Plasma Physics Laboratory. Special features of NSTX include that large ion orbits are emphasized in its geometry and thus offer a major opportunity within fusion research for focused exploration of their ubiquitous effects, including comparison with simulation codes. The CompX CQL3D Fokker-Planck code was be further adapted to the finite-orbit-width physics. Comparison with experiment ensured that the computer codes have sufficient accuracy to accurately model the experiments. Nonthermal distributions of energetic ions are produced in experiments-- and modeled with the codes-- exhibiting the signatures of auxiliary heating, transport, and radiation processes within the plasma. Using physics-based modeling, in conjunction with experimental data, nonthermal distributions can provide keys to validation and quantification of auxiliary heating physics. Nonthermal distributions also hold particular information on radial transport processes, not obscured by the smoothing Maxwellization effects of Coulomb collisions. Generally, radial transport is not well understood but is a key to efficient fusion energy production. By comparison with Fokker-Planck modeling, the velocity dependence of radial transport coefficients becomes experimentally accessible, particularly in cases of well-modeled sources such as neutral beams, fast wave power, or the toroidal electric field. It is clear from modeling of fast-wave interactions with ions that finite-orbit-width effects play a significant role. For example, a different set of ions is computed to intersect a given cyclotron resonance depending on whether or not radial orbit drifts are taken into account. Also, radial transport, associated bootstrap current, and alpha channeling depend on radial drifts. Ion cyclotron heating above the first harmonic interacts preferentially with higher velocity ions, giving large radial drifts. The CQL3D Fokker-Planck code, maintained by the proposers, is a physics based model used extensively within the US fusion community to compare with and interpret experimental observations. At the beginning of this grant, bounce-averages of the rf quasilinear and other operators have been performed neglecting the radial drifts which give finite orbit widths to the particle orbits. The proposed work included a major upgrade to CQL3D to include finite-orbit-width effects be accounted for by performing the bounce-averages of rf and neutral beam fast ions along guiding center orbits. This CQL3D enhancement provided microwave and neutral beam contributions to neoclassical radial transport coefficients for nonthermal distributions, and substantially increased the comprehensiveness of the ion model. Additional work validated Fokker-Planck and ray tracing modeling of neutral beam and high harmonic fast wave absorption and current drive against the NSTX experiment, as had been very successful for electron cyclotron current drive in the DIII-D tokamak at General Atomics and lower hybrid waves on C-Mod at MIT. The validation work was in conjunction with staff and graduate students at Princeton Plasma Physics Laboratory. This DOE grant supported fusion energy research, a potential long-term solution to the world's energy needs. The research grant under consideration, DE-SC0006614, provided research support at the 0.3 Full-Time-Equivalent level for application of computer models to aid in understanding and projecting efficacy of heating and current drive sources in the National Spherical Torus Experiment, a tokamak variant, at the Princeton Plasma Physics Laboratory. The NSTX experiment explores the physics of very tight aspect ratio, almost spherical tokamaks, aiming at producing steady-state fusion plasmas. The current drive is an integral part of the steady-state concept, maintaining the magnetic geometry in the steady-state tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and development of line type modulators for high impedance electron gun

Conventional line type modulators are routinely used for powering pulsed power microwave devices such as magnetrons and klystrons used for radar, medical and scientific applications. The load impedance (operating point) is fairly well defined in these cases, and makes the design of the discharging circuit of the modulator straight forward. This paper describes the Line type modulators that have been developed and being routinely used for powering the Triode Electron Gun of industrial electron linacs. The beam parameters of such guns are user defined and the pulse current varies from few mA to 800mA (typ). The beam energies requirement varies from 40 keV to 80 keV. Hence the impedance offered by the electron gun to the power source (modulator) is not well defined. The load capacitance which is inclusive of the various stray capacitances along with the intrinsic gun capacitance is ∼ 200-400 pF. This capacitance, which depends on the configuration, shunts the load and makes the effective load highly capacitive with the resistive part varying over a wide range. The paper describes the design and development of conventional line type modulators for powering Electron gun load of the type described above. (author)

43 PARTICLE ACCELERATORS↗

An adaptable multiple power source for mass spectrometry and other scientific instruments

Power supplies are commonly used in the operation of many types of scientific equipment, including mass spectrometers and ancillary instrumentation. A generic modern mass spectrometer comprises an ionization source, such as electrospray ionization (ESI), ion transfer devices such as ion funnels and multipole ion guides, and ion signal detection apparatus. Very often such platforms include, or are interfaced with ancillary elements in order to manipulate samples before or after ionization. In order to operate such scientific instruments, numerous direct current (DC) channels and radio frequency (RF) signals are required, along with other controls such as temperature regulation. In particular, DC voltages in the range of ±400 V, along with MHz range RF signals with peak-to-peak amplitudes in the hundreds of volts range are commonly used to transfer ionized samples under vacuum. Additionally, an ESI source requires a high voltage (HV) DC source capable of producing several thousand volts and heaters capable of generating temperatures up to 300°C. All of these signals must be properly synchronized and managed in order to carry out ion trapping, accumulation and detection.

47 OTHER INSTRUMENTATION↗

Demonstration of sub-GV/m accelerating field in a photoemission electron gun powered by nanosecond 𝑋-band radio-frequency pulses

Radio-frequency (rf) photoemission electron guns operating at higher accelerating gradients offer a pathway to produce brighter electron bunches. Brighter beams are expected to revolutionize many areas of science: they could form the backbone of next-generation compact x-ray free-electron lasers or provide coherent ultrafast quantum electron probes. We report on the experimental demonstration of an rf photoemission electron source supporting an accelerating field close to 400 MV/m at the photocathode surface without major rf breakdown or significant dark current over a 3-week experimental run. This unprecedented gradient was achieved by operating the gun in a new regime with short rf pulses, ~9ns X-band (11.7 GHz). The demonstrated paradigm provides a viable path to form relativistic electron beams with unprecedented brightness.

43 PARTICLE ACCELERATORS↗

The Serendip II design

Serendip II is an automated system designed to perform a real time search for narrow band radio signals in the spectra of sources in a regularly scheduled, non-Seti, astronomical observing program. Because Serendip II is expected to run continuously without requiring dedicated observing time, it is hoped that a large portion of the sky will be surveyed at high sensitivity and low cost. Serendip II will compute the power spectrum using a 65,536 channel fast Fourier transform processor with a real time bandwidth of 128 KHz and 2 Hz per channel resolution. After searching for peaks in a 100 KHz portion of the radio telescope's IF band, Serendip II will move to the next 100 KHz portion using a programmable frequency synthesizer; when the whole IF band has been scanned, the process will start again. Unidentified peaks in the power spectra are candidates for further study and their celestial coordinates will be recorded along with the time and power, IF and RF frequency, and bandwidth of the peak.

Werthimer, D.↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

The Berkeley Serendip Project

An automated system was designed to perform a real time search for narrow band radio signals in the spectra of sources in a regularly scheduled, non-SETI astronomical observing program. The system will compute the power spectrum using a 65,536 channel fast Fourier transform processor with a real time bandwidth of 128 KHz and 2 Hz per channel resolution. After search for peaks in a 100 KHz portion of the IF band of the radio telescope, the system will move to the next 100 KHz portion using a programmable frequency synthesizer. When the whole IF band is scanned, the process will start again. Unidentified peaks in the power spectra are candidates for further study and their celestial coordinates will be recorded along with the time and power, IF and RF frequency, and bandwidth of the peak. Most of the hardware was developed and the machine software is in the process of being finalized. A number of means for identifying and rejecting power spectra peaks which have a high likelihood of being nonuseful are being investigated.

Bowyer, S.↗

Chemical Free Surface Processing for High Gradient Superconducting RF Cavities

Chemical treatment such as buffered chemical polishing (BCP) or electro polishing (EP) followed by high pressure rinsing (HPR) of niobium (Nb) superconducting RF (SRF) cavities is expensive and complex multistep process. Furthermore, the cavity RF surfaces after the treatment still have numerous bubbles and pits that result from welding. These quench-producing weld defects together with the particulate contamination, result in significant scatter of the multi-cell Nb SRF cavities performance characteristics. This scatter is the major problem in the current manufacturing of the Nb SRF cavities. When developed the chemical free surafce processing using IEB will benefit first J-lab's CEBAF and Fermilab's Project X. Also, light sources, require 1.3 - 1.5 GHz SRF structures. Furthermore, IEB will produce much broader impact because it can be implemented into manufacturing of many other types of RF devices including both superconducting as well as normal conducting RF cavities. This program will develop a new process that will enhance quality of the superconducing radio-frequency cavities and allow acceleration of charged particles to much higher energies. The process also will improve the cavity manufacturing and result in substantial cost reduction of superconducting radio-frequency high-energy particle accelerators. Niobium samples were successfully processed by a DC electron beam to a degree that is suitable for the interior surface of an SRF cavity. To accomplish this, a complete system was developed from the ground up. A vacuum chamber system was acquired and adapted to act as the vessel for performing the Nb processing experiments. An extremely robust high voltage power supply was developed and manufactured to provide the power necessary to drive the multi-kW DC electron gun. A high voltage isolation filament transformer was also designed and manufactured to provide the necessary current to drive the filament within the electron gun. Finally, a beam melt characterization DC electron gun was created. This gun was used to explore the parameter space of interest for processing Nb SRF cavities. The beam melt characterization tests concluded that multiple quick passes at moderate beam power provided the most ideal melt zone characteristics Nb surfaces. It was also found that excellent melt and polish results could be achieved at lower voltages than originally conceived, getting the great results at a beam voltage of 20kV versus the 50kV used in the initial Phase I testing at Jefferson Laboratory. Operating at 20kV will also greatly reduce the challenges of designing a compact DC electron gun for processing of complete Nb SRF cavities, which will be done in Phase III. This final report is divided in eight parts which cover the major investigation work and results which have been performed and achieved. The first part addresses the design, fabrication and testing of the vacuum chamber. In the second part, the DC power supply output circuit design is presented for providing an operating space of 50-60kV with currents from 20-160mA and short and open circuit fault modes are considered and resolved. The third section covers testing and commissioning of the high voltage step up transformer and 150kV isolation transformer. Section four covers the design, construction and performance for a 100kV high voltage bushing. Section number five treats the filament design and load testing. Section number six covers electron gun design and simulation of electron beam melting. Section seven presents the beam target design, assembly and testing and test gun with solenoid magnet, design, fabrication and testing. Finally, section eight demonstrates electron beam melting and polishing of Nb, Cu and SS samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferroelectric Emission Cathodes for Low-Power Electric Propulsion

Low- or no-flow electron emitters are required for low-power electric thrusters, spacecraft plasma contactors, and electrodynamic tether systems to reduce or eliminate the need for propellant/expellant. Expellant-less neutralizers can improve the viability of very low-power colloid thrusters, field emission electric propulsion devices, ion engines, Hall thrusters, and gridded vacuum arc thrusters. The NASA Glenn Research Center (GRC) is evaluating ferroelectric emission (FEE) cathodes as zero expellant flow rate cathode sources for the applications listed above. At GRC, low voltage (100s to approx. 1500 V) operation of FEE cathodes is examined. Initial experiments, with unipolar, bipolar, and RF burst applied voltage, have produced current pulses 250 to 1000 ns in duration with peak currents of up to 2 A at voltages at or below 1500 V. In particular, FEE cathodes driven by RF burst voltages from 1400 to 2000 V peak to peak, at burst frequencies from 70 to 400 kHz, emitted average current densities from 0.1 to 0.7 A/sq cm. Pulse repeatability as a function of input voltage has been initially established. Reliable emission has been achieved in air background at pressures as high as 10(exp -6) Torr.

Kovaleski, Scott D.↗

Summary of RF Technology Program Activities, October 2013 - September 2017

The goals of the National RF Research and Development Program (NRRDP) are to advance the basic understanding of high-power radio frequency (RF) in a plasma environment, and to maintain the high-power transmitters and cooling water systems required to support the ITER Ion Cylcotron Range of Frequencies (ICRF) transmission line high power component testing and operation of the Proto-Material Plasma Exposure eXperiment (MPEX) device. The work includes the study of the RF sheath, and development of RF-related diagnostics. These include active and passive spectroscopic diagnostics that can provide local and line integrated measurements of RF and Direct Current (DC) electric fields in the edge plasma of fusion devices, as well as measurements of other parameters. One of these, the Doppler Free Saturation Spectroscopy (DFSS) diagnostic, utilizes a laser beam split into two intersecting, counter-propagating pump and probe beams, whose intersection defines the measurement region. DFSS has demonstrated measurements of atomic spectra with 500 times greater resolution than passive Optical Emission Spectroscopy (OES). This allows Stark effect based electric field measurements to be made with two orders of magnitude high sensitivity than with OES. Measurements have been made using an ORNL electron-cyclotron resonant (ECR) plasma source producing densities up to 10 19 m -3 , in the vicinity of an RF-biased planar electrode.

47 OTHER INSTRUMENTATION↗

Ion Source Development For The Proposed FNAL 750 keV Injector Upgrade

Currently there is a Proposed FNAL 750 keV Injector Upgrade for the replacement of the 40 year old Fermi National Laboratory (FNAL) Cockcroft-Walton accelerators with a new ion source and 200 MHz Radio Frequency Quadruple (RFQ). The slit type magnetron being used now will be replaced with a round aperture magnetron similar to the one used at Brookhaven National Lab (BNL). Operational experience from BNL has shown that this type of source is more reliable with a longer lifetime due to better power efficiency. The current source development effort is to produce a reliable source with >60 mA of H{sup -} beam current, 15 Hz rep-rate, 100 {mu}s pulse width, and a duty factor of 0.15%. The source will be based on the BNL design along with development done at FNAL for the High Intensity Neutrino Source (HINS).

43 PARTICLE ACCELERATORS↗

Fully Printed High-Frequency Phased-Array Antenna on Flexible Substrate

To address the issues of flexible electronics needed for surface-to-surface, surface-to-orbit, and back-to-Earth communications necessary for manned exploration of the Moon, Mars, and beyond, a room-temperature printing process has been developed to create active, phased-array antennas (PAAs) on a flexible Kapton substrate. Field effect transistors (FETs) based on carbon nanotubes (CNTs), with many unique physical properties, were successfully proven feasible for phased-array antenna systems. The carrier mobility of an individual CNT is estimated to be at least 100,000 sq cm/V(dot)s. The CNT network in solution has carrier mobility as high as 46,770 sq cm/V(dot)s, and has a large current-density carrying capacity of approx. 1,000 mA/sq cm , which corresponds to a high carrying power of over 2,000 mW/ sq cm. Such high carrier mobility, and large current carrying capacity, allows the achievement of high-speed (>100 GHz), high-power, flexible electronic circuits that can be monolithically integrated on NASA s active phasedarray antennas for various applications, such as pressurized rovers, pressurized habitats, and spacesuits, as well as for locating beacon towers for lunar surface navigation, which will likely be performed at S-band and attached to a mobile astronaut. A fully printed 2-bit 2-element phasedarray antenna (PAA) working at 5.6 GHz, incorporating the CNT FETs as phase shifters, is demonstrated. The PAA is printed out at room temperature on 100-mm thick Kapton substrate. Four CNT FETs are printed together with microstrip time delay lines to function as a 2-bit phase shifter. The FET switch exhibits a switching speed of 0.2 ns, and works well for a 5.6-GHz RF signal. The operating frequency is measured to be 5.6 GHz, versus the state-of-the-art flexible FET operating frequency of 52 MHz. The source-drain current density is measured to be over 1,000 mA/sq cm, while the conventional organic FETs, and single carbon nanotube-based FETs, are typically in the mA to mA/sq cm range. The switching voltage used is 1.8 V, while the state-of-the-art flexible FET has a gate voltage around 50 V. The gate voltage can effectively control the source-drain current with an ON-OFF ratio of over 1,000 obtained at a low Vds bias of 1.8 V. The azimuth steering angles of PAA are measured at 0deg, -14.5deg, -30deg, and 48.6deg. The measured far-field patterns agree well with simulation results. The efficiency of the 2-bit 2-element PAA is measured to be 39 percent, including the loss of transmission line, FET switch, and coupling loss of RF probes. With further optimization, the efficiency is expected to be around 50-60 percent.

Chen, Yihong↗

RF Processing Experience with the GTF Prototype RF Gun

The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. A total of five different metal cathodes (4 Cu and 1 Mg) have been installed on the GTF gun. The rf processing history with the different cathodes will be presented including peak field achieved at the cathode. The LCLS gun is intended to operate at 120 MV/m and fields up to 140 MV/m have been achieved in the GTF gun. After installing a new cathode the number of rf pulses required to reach 120 MV/m is approximately 5-10 million. Total emitted dark current and Fowler Nordheim plots are also shown over the life of the cathode. The GTF photo-injector gun is an S-band standing-wave structure, with two resonant cavities and an intervening thick washer (Figure 1). The flat, back wall of the first cavity is a copper plate that serves as photocathode when illuminated with ultraviolet light from a pulsed, high-power laser. RF power enters the gun through an iris on the outer wall of the second cavity, and is coupled to the first through the axial opening of the washer. The first cavity is often referred to as a half cell, because its full-cell length has been truncated by the cathode plate and the second cavity is called the full cell. The gun is designed to operate in a {pi} mode, with the peak field on axis in each cell approximately equal. The maximum in the half cell occurs at the cathode, and in the full cell near the center of the cavity. The field profile and tuning procedures are discussed in a separate tech note [1].

43 PARTICLE ACCELERATORS↗

PROSPECTS FOR A VERY HIGH POWER CW SRF LINAC

Steady development in SRF accelerator technology combined with the success of large scale installations such as CEBAF at Jefferson Laboratory and the SNS Linac at ORNL gives credibility to the concept of very high average power CW machines for light sources or Proton drivers. Such machines would be powerful tools for discovery science in themselves but could also pave the way to reliable cost effective drivers for such applications as neutrino factories, an energy-frontier muon collider, nuclear waste transmutation or accelerator driven subcritical reactors for energy production. In contrast to machines such as ILC that need maximum accelerating gradient, the challenges in these machines are mainly in efficiency, reliability, beam stability, beam loss and of course cost. In this paper the present state of the art is briefly reviewed and options for a multi-GeV, multi-MW CW linac are discussed.

43 PARTICLE ACCELERATORS↗

Aberration corrected RF flipper for high resolution neutron spectroscopy

Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.

36 MATERIALS SCIENCE↗