Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Image segmentation for analyzing galaxy-galaxy strong lensing systems

The goal of this Letter is to develop a machine learning model to analyze the main gravitational lens and detect dark substructure (subhalos) within simulated images of strongly lensed galaxies. Using the technique of image segmentation, we turn the task of identifying subhalos into a classification problem, where we label each pixel in an image as coming from the main lens, a subhalo within a binned mass range, or neither. Our network is only trained on images with a single smooth lens and either zero or one subhalo near the Einstein ring. On an independent test set with lenses with large ellipticities, quadrupole and octopole moments, and for source apparent magnitudes between 17–25, the area of the main lens is recovered accurately. On average, only 1.3% of the true area is missed and 1.2% of the true area is added to another part of the lens. In addition, subhalos as light as 10 8.5 M ⊙ can be detected if they lie in bright pixels along the Einstein ring. Furthermore, the model is able to generalize to new contexts it has not been trained on, such as locating multiple subhalos with varying masses or more than one large smooth lens.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK X. Planck Low Frequency Instrument frequency maps with sample-based error propagation

We present Planck Low Frequency Instrument (LFI) frequency sky maps derived within the BEYONDPLANCK framework. This framework draws samples from a global posterior distribution that includes instrumental, astrophysical, and cosmological parameters, and the main product is an entire ensemble of frequency sky map samples, each of which corresponds to one possible realization of the various modeled instrumental systematic corrections, including correlated noise, time-variable gain, as well as far sidelobe and bandpass corrections. This ensemble allows for computationally convenient end-to-end propagation of low-level instrumental uncertainties into higher-level science products, including astrophysical component maps, angular power spectra, and cosmological parameters. We show that the two dominant sources of LFI instrumental systematic uncertainties are correlated noise and gain fluctuations, and the products presented here support – for the first time – full Bayesian error propagation for these effects at full angular resolution. We compared our posterior mean maps with traditional frequency maps delivered by the Planck Collaboration, and find generally good agreement. The most important quality improvement is due to significantly lower calibration uncertainties in the new processing, as we find a fractional absolute calibration uncertainty at 70 GHz of Δg 0 /g 0 = 5 x 10 -5 , which is nominally 40 times smaller than that reported by Planck 2018. However, we also note that the original Planck 2018 estimate has a nontrivial statistical interpretation, and this further illustrates the advantage of the new framework in terms of producing self-consistent and well-defined error estimates of all involved quantities without the need of ad hoc uncertainty contributions. We describe how low-resolution data products, including dense pixel-pixel covariance matrices, may be produced from the posterior samples directly, without the need for computationally expensive analytic calculations or simulations. We conclude that posterior-based frequency map sampling provides unique capabilities in terms of low-level systematics modeling and error propagation, and may play an important role for future Cosmic Microwave Background (CMB) B-mode experiments aiming at nanokelvin precision.

79 ASTRONOMY AND ASTROPHYSICS↗

End-to-End Jet Classification of Boosted Top Quarks with CMS Open Data

We describe a novel application of the end-to-end deep learning technique to the task of discriminating top quark-initiated jets from those originating from the hadronization of a light quark or a gluon. The end-to-end deep learning technique combines deep learning algorithms and low-level detector representation of the high-energy collision event. In this study, we use lowlevel detector information from the simulated CMS Open Data samples to construct the top jet classifiers. To optimize classifier performance we progressively add low-level information from the CMS tracking detector, including pixel detector reconstructed hits and impact parameters, and demonstrate the value of additional tracking information even when no new spatial structures are added. Relying only on calorimeter energy deposits and reconstructed pixel detector hits, the end-to-end classifier achieves a ROC-AUC score of 0.975±0.002 for the task of classifying boosted top quark jets. After adding derived track quantities, the classifier ROC-AUC score increases to 0.9824±0.0013, serving as the first performance benchmark for these CMS Open Data samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of a 2.1 MeV H− beam with an Allison scanner

Transverse 2D phase space distributions of a 2.1 MeV, 5 mA H− beam are measured at the Proton Improvement Plan II Injector Test accelerator at Fermilab with an Allison scanner. This paper describes the design, calibration, and performance of the scanner along with the main results from beam measurements. Analyses of the recorded phase portraits are performed primarily in action-phase coordinates. The stability of the action under linear optics makes it easier to compare measurements taken under different beamline conditions. The amplitude of a single measured point (“pixel”) is proportional to the phase density in the corresponding portion of the beam. When the Twiss parameters are calculated using only the high-phase density part of the beam, the pixel amplitude in the beam core is found to be decreasing approximately exponentially with action and to be phase-independent. Outside of the core, the amplitudes decrease with action at a slower rate than in the core. This “tail” comprises 10%–30% of the beam, with 0.1% of the total measured intensity extending beyond action 10–20 times larger than the rms emittance. The transition from the core to the tail is accompanied by the appearance of two “branches” that are separated in phase and extend beyond the core. A set of selected measurements shows that there is no measurable emittance dilution along the beamline; the beam parameters are practically constant over a 0.5 ms pulse; and scraping in various parts of the beamline is an effective way to decrease the transverse tails by removing the branches.

Richard, C. (ORCID:000000029891135X)↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Timing characterization of fast hCMOS sensors

We describe a method of analyzing gate profile data for ultrafast x-ray imagers that allows pixel-by-pixel determination of temporal sensitivity in the presence of substantial background oscillations. With this method, systematic timing errors in gate width and gate arrival time of up to 1 ns (in a 2 ns wide gate) can be removed. In-sensor variations in gate arrival and gate width are observed, with variations in each up to 0.5 ns. This method can be used to estimate the coarse timing of the sensor, even if errors up to several ns are present.

Benedetti, L. R. (ORCID:0000000160502983)↗

Poisson_CCD: A dedicated simulator for modeling CCDs

A dedicated simulator, Poisson_CCD, has been constructed which models astronomical CCDs by solving Poisson’s equation numerically and simulating charge transport within the CCD. The potentials and free carrier densities within the CCD are self-consistently solved for, giving realistic results for the charge distribution within the CCD storage wells. The simulator has been used to model the CCDs that are being used to construct the LSST digital camera. The simulator output has been validated by comparing its predictions with several different types of CCD measurements, including astrometric shifts, brighter-fatter induced pixel–pixel covariances, saturation effects, and diffusion spreading. The code is open source and freely available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

INR-TEM: Robust cavity detection in multifocus TEM images via implicit neural representations

When characterizing materials using transmission electron microscopy (TEM) images, detecting and quantifying small features in microstructures, such as cavities, pose significant challenges. Off-the-shelf object detection models, including YOLOv8, show considerable performance degradation, particularly when images vary in resolution and the objects of interest possess a low percentage of the total image region of interest. In this study, we introduce a novel detection pipeline that incorporates an implicit neural representation (INR)-based detection method, INR-TEM, and two-modality imaging (e.g., under-focused and over-focused images typically acquired during materials characterization) to improve object detection performance. The INR-TEM method incorporates a pixel-wise prediction principle inspired by pixel-wise centerness weighting. INR-TEM demonstrates superior robustness to resolution variability, maintaining high detection accuracy even at low image resolutions compared to YOLOv8. To leverage INR-TEM effectively in real-world two-modality characterization applications, we further integrate a two-stage motion correction pipeline designed explicitly for aligning multifocus TEM images. The alignment process, comprising keypoint (based on scale-invariant feature transform, SIFT) and intensity matching, significantly mitigates the adverse effects of perceived motion-induced image degradation during through-focal TEM imaging, directly enhancing INR-TEM’s detection capability over conventional single-focus images. Our integrated INR-TEM cavity detection framework notably improves performance across various cavity sizes, outperforming off-the-shelf YOLOv8 detections that rely on a single image modality.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Pan-tropical daily L-band microwave land surface emissivity retrieval from GNSS-R observations

The uncertainties in microwave land surface emissivity (MLSE) measurements have long limited the use of spaceborne microwave radiometer data. As an emerging observation method, Global Navigation Satellite System Reflectometry (GNSS-R) has demonstrated great potential in several land and ocean applications. In this study, a method for obtaining daily MLSE dataset in the pan-tropical region from Cyclone GNSS (CYGNSS) observations is presented and evaluated. The CYGNSS observations are first aggregated into the Equal-Area-Scalable-Earth (EASE) 2.0 36 km grid by a combined weight function of distance, time, and signal-to-noise ratio variance. Then, the method employs a pixel-by-pixel regression algorithm to conduct the daily MLSE retrieval using reference emissivity derived from the Soil Moisture Active Passive (SMAP) brightness temperature. The CYGNSS MLSE shows good agreement with SMAP MLSE, delivering an overall root-mean-square error (RMSE) of 0.022 and 0.017 for horizontal and vertical polarization, respectively, during the training set spanning the whole year of 2018. Furthermore, on the test set from January 2019 to May 2019, the RMSE values amounted to 0.030 and 0.023 for horizontal and vertical polarization, respectively. Temperature records from the International Soil Moisture Network are employed to calculate the emissivity and for in-situ validation, which yield an RMSE of 0.034 and 0.026 for the two polarizations, respectively. The proposed algorithm provides an encouraging approach to obtain accurate daily MLSE dataset for microwave remote sensing. Compared to the SMAP MLSE, the CYGNSS MLSE has a remarkable improvement of 86% in temporal resolution, greatly complementing the existing microwave emissivity datasets.

54 ENVIRONMENTAL SCIENCES↗

Robust two-colour pyrometry uncertainty analysis to acquire spatially-resolved measurements

Two-colour pyrometry (2CP) has been used over several decades to study engine-relevant combustion processes, but results are generally regarded as qualitative or semi-quantitative. In many current 2CP systems, large measurement errors are introduced by parallax because the two measured wavelengths are not from the same line of sight. Here this work presents a spatially-resolved 2CP system with the objective of quantifying and reducing measurement uncertainty. An optical setup that eliminates parallax in 2CP is used together with pixel-by-pixel calibration of the camera sensor to increase measurement accuracy. Primary uncertainty terms are identified, and an error propagation analysis is performed to compute uncertainties in the final results of soot temperature, soot concentration parameter, KL, and soot mass. These methodologies are applied to investigate an auto-igniting fuel spray in a constant pressure flow rig at diesel-like conditions of high ambient pressure and temperature. Results show bias uncertainty of around 200 K (≈10%) for temperature and about 40%–60% for KL. High uncertainty was found to occur on the diffusion flame front where both optical thickness and soot concentrations are small. However, these uncertain measurement zones with relatively low soot concentrations contribute minimally to the total soot mass present in the reacting jet during the temporal evolution of the flame.

42 ENGINEERING↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗