Snapshot Report: Linear Luminaires, Troffer Luminaires, & Troffer Retrofit Kits
A report using LED Lighting Facts data to examine the current state of the market for linear luminaires, troffer luminaires, and troffer retrofit kits.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A report using LED Lighting Facts data to examine the current state of the market for linear luminaires, troffer luminaires, and troffer retrofit kits.
The purpose of this guideline is to provide a methodology for estimating additional costs for retrofitting carbon capture technologies onto existing fossil power plants.
Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.
The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) mission is to “create and sustain American leadership in the transition to a global clean energy economy.” EERE’s vision is a strong and prosperous America powered by clean, affordable, and secure energy. In support of this vision, one of EERE’s strategic pillars is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.
NETL has been reviewing recently published DOE-funded FEED studies for retrofitting fossil power plants with carbon capture technology. This presentation, prepared for the 8th IEAGHG CCS Cost Network Workshop, presents learnings from reviewing these FEED studies.
This report is GSA Green Proving Ground M&V study that assesses the performance of Linear LED Retrofit products for fluorescent lighting troffers. The study evaluates describes energy efficiency, photometric performance, economic analysis, occupant satisfaction and recommendations for broad implementation within GSA facilities.
The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.
One of the challenges of supersymmetry (SUSY) breaking and mediation is generating a {mu} term consistent with the requirements of electro-weak symmetry breaking. The most common approach to the problem is to generate the {mu} term through a SUSY breaking F-term. Often these models produce unacceptably large B{mu} terms as a result. We will present an alternate approach, where the {mu} term is generated directly by non-perturtative effects. The same non-perturbative effect will also retrofit the model of SUSY breaking in such a way that {mu} is at the same scale as masses of the Standard Model superpartners. Because the {mu} term is not directly generated by SUSY breaking effects, there is no associated B{mu} problem. These results are demonstrated in a toy model where a stringy instanton generates {mu}.
The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a cost-effective solution package that met the requirements of 30% source energy savings compared to the pre-retrofit performance. This home had already been updated aesthetically (kitchen and bathrooms), so the owners wanted the energy-efficiency measures to be as non-disruptive to the interior finishes as possible.
We did energy efficient retrofits for the Indiana University Purdue University—Indianapolis Health Science Building using the eQuest energy software. The current dual-fan dual-duct (DFDD) system is 41 years old and has a higher energy utilization index (EUI) than the national average for similar building types. The baseline model with the DFDD system was compared with the actual electrical consumption. Then, two energy efficiency measures (EEMs) were applied to the model. The first EEM was ‘DFDD system with chilled water and steam heating,’ and the second EEM was ‘single-duct variable air volume (VAV) with chilled water and electric reheat.’ After comparative simulations and analyses, it was determined that the ‘single duct VAV with chilled water and electric reheat’ was the most energy efficient and saved 28% in utility costs. The recommendation given to the facility services was to change the current DFDD system to the single-duct VAV system. The single-duct VAV system will save energy and create additional space above the ceiling after the heating duct is removed.
While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.
This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.
This report assesses the potential national benefits of retrofitting U.S. single-family homes with state-of-the-art GSHP systems at various penetration rates. The benefits considered include energy savings, reduced summer electrical peak demand, consumer utility bill savings, and reduced carbon dioxide (CO2) emissions. The assessment relies heavily on energy consumption and other data obtained from the Residential Energy Consumption Survey conducted by the U.S. Department of Energy s Energy Information Administration. It also considers relative differences in energy consumption between a state-of-the-art GSHP system and existing residential space-heating, space-cooling, and water-heating (SH SC WH) systems, which were determined with a well-established energy analysis program for residential SH SC WH systems. The impacts of various climate and geological conditions, as well as the efficiency and market share of existing residential SH SC WH systems, have been taken into account in the assessment.
This case study describes the retrofit of a home in West Concord, Massachusetts that proved that a 50% reduction in home energy use could be met today in existing housing.
This case study describes how SMUD teamed with Building America partners to retrofit aging, foreclosed homes into high-performance homes.
This case study describes a retrofit project between SMUD and Building America to create a high-performance home.
The University of Hawaii at Manoa (UHM) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program.
Hines partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.