Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Optical-mechanical line-scan imaging process - Its information capacity and efficiency

Optical-mechanical line-scan techniques have been applied to earth satellite multispectral imaging systems. The capability of the imaging system is generally assessed by its information capacity. An approach based on information theory is developed to formulate the capacity of the line-scan process. Included are the effects of blurring of spatial detail, photosensor noise, aliasing, and quantization. The information efficiency is shown to be dependent on sampling rate, system frequency response shape, SNR, and quantization interval.

Huck, F. O.↗

Scanning thermal plumes

Over a three-year period 800 thermal line scans of power plant plumes were made by an airborne scanner, with ground truth measured concurrently at the plants. Computations using centered finite differences in the thermal scanning imagery show a lower bound in the horizontal temperature gradient in excess of 1.6 C/m. Gradients persist to 3 m below the surface. Vector plots of the velocity of thermal fronts are constructed by tracing the front motion in successive thermal images. A procedure is outlined for the two-point ground calibration of a thermal scanner from an equation describing the scanner signal and the voltage for two known temperatures. The modulation transfer function is then calculated by input of a thermal step function and application of digital time analysis techniques using Fast Fourier Transforms to the voltage output. Field calibration tests are discussed. Data accuracy is limited by the level of ground truth effort chosen.

Scarpace, F. L.↗

Preliminary design study. Shuttle modular scanning spectroradiometer

Fundamental concepts on which to base a detailed design for a Shuttle Modular Scanning Spectroradiometer were developed, and a preliminary design is presented. The recommended design features modularity and flexibility. It includes a 75-cm f/1.7-telescope assembly in an all-reflective Schmidt configuration, a solid state scan system (pushbroom) with high resolution over a 15 deg field of view, and ten detector channels covering the spectral range from 0.45 to 12.5 micrometers. It uses charge transfer device techniques to accommodate a large number of detector elements for earth observation measurements. Methods for in-flight radiometric calibration, for image motion compensation, and for data processing are described. Recommendations for ground support equipment are included, and interfaces with the shuttle orbiter vehicle are illustrated.

Source record↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

Limb-darkening scans of Jupiter

Representative center-limb photometric measurements of several areas on Jupiter are presented in the form of limb-darkening scans taken through narrow-band interference filters which isolate continuum regions near the 3-0 and 4-0 hydrogen quadrupole bands (8200 and 6300 A, respectively). Results of scans measured through filters which isolate two regions dominated by methane absorption (6190 and 7250 A) are also discussed. Limb-darkening curves at all four wavelengths are computed for semiinfinite homogeneous isotropically scattering atmospheres with different values of the single-scattering albedo of the cloud particles. It is found that albedo values between 0.985 and 0.989 match the data over most of the northern component of the South Equatorial Belt. The single-scattering albedo values are used to show that the equatorial regions of Jupiter which emit at 5 microns may be relatively clear while the tropical regions may be relatively cloudy.

Pilcher, C. B.↗

Multiline radar scan

Scanning scheme is more efficient than conventional scanning. Originally designed for optical radar in space vehicles, scheme may also find uses in site-surveillance security systems and in other industrial applications. It should be particularly useful when system must run on battery energy, as would be case in power outages.

Levinson, S.↗

Scanning radiometer for measurement of forward-scattered light to determine mean diameter of spray particles

A scanning radiometer is reported that measures forward-scattered light to determine the mean diameter of spray particles. An optical scanning method gives a continuous measurement of the light-scattering angle during spray nozzle tests. A method of calibration and a correction for background light are presented. Mean particle diameters of 10 to 500 micrometers can be measured.

Buchele, D. R.↗

Scanning mechanism study for multi-frequency microwave radiometers

Scanning mode for a microwave radiometer having large aperture antenna is determined from scientific needs by engineering tradeoffs. Two configurations of the scan drive mechanism with an integral momentum compensation are formulated for 1.OM and 1.4M diameter antennas. As the formulation is based on currently available components, it is possible to design and fabricate the formulated mechanism without new hardware development. A preliminary specification for major components of formulated drives is also included in the report.

Shin, I.↗

An antenna for limited scan in one plane - Design criteria and numerical simulation

Aperture illumination is synthesized through the use of overlapping subarrays with independently controlled excitations. Detailed analysis and design criteria are provided for a specific limited-scan antenna configuration scanning in one plane. The number of phase shifts is the theoretical minimum corresponding to specified aperture size and field of view. Beam pointing and width are approximately constant for moderate frequency variation, and ultralow sidelobes outside the field of view can be produced at the cost of a slight loss of illumination efficiency. Accurate aperture illumination control makes for excellent independently specified sum and difference patterns in beamforming.

Borgiotti, G. V.↗

Estimating regional heat flux from scanning radiometer data

Method using matrix approach to determine best linear estimate of total flux consistent with condition of minimum variance proves useful in meteorological studies. It is useful for researchers studying options in scanner design such as scan pattern, scan rate, and radiometer field-of-view.

Bess, T. D.↗

Torque-while-turnaround scan mirror assembly

A scan mirror assembly which is part of a thematic mapper system is described with emphasis on mechanical aspects of the design. Features of the oscillating scan mirror mechanism include: a low level of structural vibration for the impact energies involved in mirror oscillation and return of energy lost during impact to the mirror by applying torque during the instant of impact.

Starkus, C. J.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

The remote measurement of tornado-like flows employing a scanning laser Doppler system

The paper deals with a scanning laser Doppler velocimeter system employed in a test program for measuring naturally occurring tornado-like phenomena, known as dust devils. A description of the system and the test program is followed by a discussion of the data processing techniques and data analysis. The system uses a stable 15-W CO2 laser with the beam expanded and focused by a 12-inch telescope. Range resolution is obtained by focusing the optical system. The velocity of each volume of air (scanned in a horizontal plane) is determined from spectral analysis of the heterodyne signal. Results derived from the measurement program and data/system analyses are examined.

Jeffreys, H. B.↗

Nondestructive determination of the depth of planar p-n junctions by scanning electron microscopy

A method was developed for measuring nondestructively the depth of planar p-n junctions in simple devices as well as in integrated-circuit structures with the electron-beam induced current (EBIC) by scanning parallel to the junction in a scanning electron microscope (SEM). The results were found to be in good agreement with those obtained by the commonly used destructive method of lapping at an angle to the junction and staining to reveal the junction.

Chi, J.-Y.↗

Research in pilot scanning behavior

A NASA-developed oculometer, which measures pilot scanning behavior, is described in terms of design and operating parameters. Results are presented of tests conducted in a terminal configured vehicle (TVC) aft cockpit simulator, involving pilots making simulated instrument approaches. Attention is given to the amount of time the pilots spend scanning the SFD and EADI CRT displays, and to differences resulting from both the physical location of the CRTs (within a 30 x 30 x 30 cm space), and from their intrinsic characteristics.

Waller, M. C.↗

System considerations for an earth radiation budget scanning radiometer

The objective of the scanning radiometer of the Earth Radiation Budget Satellite System is to measure the longwave and reflected shortwave radiation from the earth on a gridwork of approximately 250 km square regions in order to obtain one-month averages of flux with global coverage to an accuracy of 14 W/sq m. A number of considerations in the choice of some of the design parameters of the scanner are discussed. The error sources which must be considered in the design of a scanning radiometer designed to measure regional radiation budget are examined. An analysis of the system performance through spatial averaging is presented. The analysis provides insight into the effects of field of view, time response, onboard processing and spatial averaging.

Smith, G. L.↗

Stereographic cloud heights from the imagery of two scan-synchronized geostationary satellites

Scan synchronization of the sensors of two SMS-GOES satellites yields imagery from which cloud heights can be derived stereographically with a theoretical two-sigma random uncertainty of + or - 0.25 km for pairs of satellites separated by 60 degrees of longitude. Systematic height errors due to cloud motion can be kept below 100 m for all clouds with east-west components of speed below hurricane speed, provided the scan synchronization is within 40 seconds at the mid-point latitude, and the spin axis of each satellite is parallel to that of the earth.

Minzner, R. A.↗