Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Development of a Wind Plant Large-Eddy Simulation with Measurement-Driven Atmospheric Inflow: Preprint

This paper details the development of an aeroelastic wind plant model with large-eddy simulation (LES). The chosen LES solver is the Simulator for Wind Farm Applications (SOWFA) based on the OpenFOAM framework, coupled to NREL's comprehensive aeroelastic analysis tool, FAST. An atmospheric boundary layer (ABL) precursor simulation was constructed based on assessments of meteorological tower, lidar, and radar data over a 3-hour window. This precursor was tuned to the specific atmospheric conditions that occurred both prior to and during the measurement campaign, enabling capture of a night-to-day transition in the turbulent ABL. In the absence of height-varying temperature measurements, spatially averaged radar data were sufficient to characterize the atmospheric stability of the wind plant in terms of the shear profile, and near-ground temperature sensors provided a reasonable estimate of the ground heating rate describing the morning transition. A full aeroelastic simulation was then performed for a subset of turbines within the wind plant, driven by the precursor. Analysis of two turbines within the array, one directly waked by the other, demonstrated good agreement with measured time-averaged loads.

17 WIND ENERGY↗

Mars water vapor, near-surface

In a previous paper we concluded that the temperature sensors aboard the Viking landers (VL-1 and VL-2) were detecting the water vapor frost point. Analysis of one Mars year of data at both lander sites substantiates this conclusion. At VL-1 it is found that the water vapor mixing ratio is constant with height through the bulk of the atmosphere, most of the time. Exceptions are during the onset phases of the two major dust storms when temporary enhancement of near-surface vapor occurs (the same phenomenon is observed at VL-2), and some depletion of near-surface vapor during the decay phase of the first storm, possibly the second storm as well. The former suggests near-surface, northward transport of water vapor with the storms. The latter suggests adsorption of vapor on dust particles followed by surface deposition. At VL-2, severe near-surface depletion of water vapor occurs during northern autumn and winter. The residual vapor is in equilibrium with the surface condensate observed at the site during this period, indicating that the source region for the condensate must be aloft with downward transport by dust fall-out. Since the near-surface water vapor mixing ratio and concentration at VL-1 generally parallels the column abundance over VL-1 obtained by the orbiters, this suggests that VL-1 can be used to give a measure of column abundance for as long as the temperature sensors remain operational.

Ryan, J. A.↗

Crucial Role of Thermal Gradients in MMS Fluxgate In-Flight Calibration

To meet the science goals of the Magnetospheric Multiscale (MMS) mission, the Fluxgate Magnetometer (FGM) must measure the ambient magnetic field with an accuracy of 0.1 nT. On a typical MMS orbit, the offsets (or zero levels) of the 3-axis FGM can vary by ~0.5 nT (exclusive of periods in Earth shadow). Previous studies have shown that these variations can be characterized as functions of sensor temperature, TS, and can thus be corrected to within 0.2 nT in the spin plane using in-flight calibration techniques (Bromund, et al., 2016, https://ntrs.nasa.gov/citations/20160014711). In that presentation, we noted two significant observations: A distinct function of TS must be used to characterize offsets during shadow: offsets at a given TScan differ by as much as 2 nT in shadow vs sunlight. Offsets change after maneuvers, without a commensurate change in TS . These changes can be as large as 2 nT. We now note a third, related observation: Offsets increase with proximity to the earth even when TS is constant, resulting in variations of ~0.2 nT at 4-5 Earth radii (RE) These effects are evidence that offsets are a multivariate function of TS and another factor, namely: thermal gradients. Due to the spacecraft spin, the Earth and the Sun each provide a relatively constant thermal input onto one instrument face while the opposite face remains in shadow, thus giving rise to thermal gradients. The thermal gradient depend on the orientation of the spin axis relative to the Earth or Sun. We observe that offsets vary by as much as 0.17 nT/degree as a function of the tilt of the spin axis towards the Sun. Thermal input from the Earth is dominated by Outgoing Longwave Radiation (OLR). Due to the proximity to Earth, the inverse proportion of the distance squared is a significant factor in the thermal gradient attributed to Earth OLR. We find that offsets can be corrected to <0.05 nT accuracy near perigee when accounting for these factors using empirically determined constants of proportionality that account for differences in emissivity of the top and bottom faces of the sensor to OLR (as well as other thermal effects). The changes in offset associated with thermal gradient are of the same order of magnitude as effects that were formerly attributed to sensor temperature alone, and thus both parameters are necessary to characterize the FGM offsets.

Kenneth R Bromund↗

Personal Cabin Pressure Monitor and Warning System

A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.

Jan A Zysko↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Controlled heat flux measurement across a closing nanoscale gap and its comparison to theory

We present here a controlled measurement of heat flux across a closing gap that is initially less than 10 nm wide between two solid surfaces at different temperatures. The measured heat transfer is compared with our published theoretical analyses of this phenomenon that show thermal radiation dominates the heat transfer for gaps wider than about 1–2 nm, but phonon conduction dominates between 1 and 2 nm and contact. The experiments employ a thermal actuator mounted on a rocking base block for coarse positioning that supplies Joule heating to an embedded element to cause thermal expansion of a localized region for less than 10 nm spacing control, together with an embedded near-surface resistive temperature sensor to measure its temperature change due to the heat flux across the gap. The measured results are in general agreement with the theoretical predictions, and they also agree with common sense expectations. This paper not only shows nano-scale heat transfer measurement across a closing gap, it also lends additional strong support to the validity of the referenced theoretical developments. The proposed experimental approach can provide support to design of future devices for nano-scale heat transfer measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metallic magnetic calorimeters

Metallic magnetic calorimeters (MMC) are calorimetric particle detectors, typically operated at temperatures below 100 mK, that make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. During the last years a growing number of groups has started to develop MMC for a wide variety of applications, ranging from alpha-, beta- and gamma-spectrometry over the spatially resolved detection of accelerated molecule fragments to arrays of high resolution x-ray detectors. For x-rays with energies up to 6 keV an energy resolution of 2.7 eV (FWHM) has been demonstrated and we expect that this can be pushed below 1 eV with the next generation of devices. We give an introduction to the physics of MMCs and summarize the presently used readout schemes as well as the typically observed noise contributions and their impact on the energy resolution. We discuss general design considerations, the micro-fabrication of MMCs and the performance of micro-fabricated devices. In this field large progress has been achieved in the last years and the thermodynamic properties of most materials approach bulk values allowing for optimal and predictable performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring in Coal-Based Power Generation Boilers

In this project, we successfully achieved the goals we proposed: 1. optimization and development of electrochemical sensor, 2. sensor construction and package, 3. sensor testing @Longview Power Plant and data analysis, 4. lab-scale sensor optimization and corrosion database development, 5. electrochemical and corrosion monitoring validation and 6. TEA.

01 COAL, LIGNITE, AND PEAT↗

Biodegradable Temperature & pH Sensors VIASTIMULI-Responsive Polymers

Soil sensors play a key role in agriculture, and for good reason; knowledge about soil conditions enables farmers to make informed decisions about resource expenditure and crop selection for areas of land. On an industrial agriculture scale, though, this is difficult; the average U.S. farm is approximately 500 acres. To put that in perspective, if you’ve driven past Concannon Winery, all that land is only about 200 acres. This is why modern state-of-the-art soil sensors need to be equipped to not only collect precise and accurate data, but also to transmit that data large distances.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

Bimetal sensor averages temperature of nonuniform profile

Instrument that measures an average temperature across a nonuniform temperature profile under steady-state conditions has been developed. The principle of operation is an application of the expansion of a solid material caused by a change in temperature.

Dittrich, R. T.↗

Evaluation of Raman scattering as a sensor of temperature and molecular density

The performance of the Raman scattering technique for the remote monitoring of temperature and molecular number density in various wind tunnel and engine testing facilities has been experimentally evaluated. Temperature measurements were made by monitoring the pure rotational spectrum of nitrogen and the rotational branch separations of nu2 of CF4 for temperatures in the range 300 to 1000 K. These measurements yielded an average error of 2.6 and 7.6%, respectively, for temperature measurements at pressures near 1 atm. Molecular number density measurements with 20% error could be made at densities as low as 3.5 times 10 to the 22-nd power per cu m by monitoring the 6 to 8 rotational transition of nitrogen, 3.5 times 10 to the 23-rd power per cu m by monitoring the Q-branch of the fundamental vibrational transition of nitrogen, and 7 times 10 to the 22-nd power per cu m by monitoring the nu1 fundamental vibrational transition of CF4.

Bandy, A. R.↗