Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diagnostic assessment of reservoir response to fracturing: a case study from Hydraulic Fracturing Test Site (HFTS) in Midland Basin

Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.

Energy & Fuels↗

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Refabriation of HERA-HBU-2, LOC-HBU-1, and LOC-HBU-2

The development of advanced fuels for Light Water Reactors (LWRs) is essential for improved fuel performance and safety, including performance margins, uprates, and higher burnup. Because available commercial LWR fuels often cannot be used in research reactors, the refabrication of preirradiated fuel is necessary to enable follow-on testing of these fuels for characterizing fuel behavior during steady and transient irradiations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MSR Transient Simulation and MSRE Transient Benchmark with SAM and SPECTRA

In recent years, there has been renewed interest in molten salt reactors (MSRs) for their potential advantages compared to reactors that rely on solid fuel. In response to such interest, many methods and codes have been developed to capture the unique features of MSRs. Among them, SPECTRA and SAM are two system analysis codes that have been enhanced to include MSR-specific modeling capabilities, including delayed neutron precursor drift and modified point kinetics equations.This paper discusses the efforts taken to verify and validate these features. A standard MSR system test problem was developed to verify and demonstrate the capability of SPECTRA and SAM on the MSR transient simulation. Sixteen transients were simulated. Further, the results obtained from SPECTRA and SAM show good agreement. The Molten Salt Reactor Experiment transient experiments were reviewed and selected to validate the SPECTRA and SAM codes. The experiments included pump startup and coastdown tests at zero power, reactivity insertion tests at different power levels, frequency tests, and a natural convection test. The simulation results from SPECTRA and SAM show good agreement with the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Effect of Micro-Structural Dispersity of SiMo Ductile Iron on High Temperature Performance during Static Oxidation

High silicon and molybdenum (SiMo) ductile iron is commonly used for car exhaust systems, and its micro-structural dispersity depends on intrinsic parameters, which include alloy composition and inoculation efficiency, as well as extrinsic factors, such as casting wall thickness and molding material, which define cooling rate during solidification. Micro-structural dispersity is referred to as the degree of heterogeneity of sizes of structural constituencies within the microstructure. A variation in the micro-structural dispersity could impact the high temperature performance of SiMo ductile iron during static oxidation and transient thermo-mechanical loading conditions. In this study, static high temperature tests were performed on SiMo ductile iron solidified in a casting with varying wall thicknesses from 5 mm to 100 mm. The faster solidified specimens (taken from near chilled casting surfaces) had extremely high micro-structural dispersity as compared to the thicker section samples. After thermal exposure, each of the samples were characterized using 2D sections and 3D µCT images, and the results indicated an order of magnitude difference in graphite phase dispersity. The surface degradation was quantified after static oxidation experiments were implemented at temperature intervals between 650 °C and 800 °C. Non-destructive µCT 3D analysis and SEM/EDS were performed on cross sections and used to quantify the scale topology and structure. Carbon analysis was used to decouple the scale formation and decarburization phenomena that occurred within the samples. These methods enabled the quantification of the oxidation of the SiMo cast iron with different micro-structural dispersity levels after being exposed to high temperature static oxidation. Additionally, the complex material behavior during oxidation-assisted transient thermo-mechanical loading will be presented in a separate article.

36 MATERIALS SCIENCE↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

REFRACTORY COMPACT HEAT EXCHANGERS WITH EMBEDDED SENSORS ENABLED BY HYBRID ADVANCED SINTERING AND ADDITIVE APPROACH

Structural health monitoring (SHM) of compact heat exchangers (CHXs) operating in extreme environments is essential for ensuring system reliability, safety, and longevity. This study presents the development of high-temperature sensors fabricated via aerosol jet printing (AJP) using platinum ink, selected for its exceptional thermal stability, oxidation resistance, and electrical conductivity. AJP enables precise deposition of fine-feature sensor patterns onto complex geometries, making it well-suited for integration within CHX architectures. To enhance sensor durability, an alumina-based ceramic protective layer was printed over the platinum sensing elements. The sensors demonstrated stable, repeatable performance up to 900?°C during extended thermal cycling. A custom test setup was developed to evaluate sensor accuracy and robustness under steady-state and transient conditions. Substrate screening identified HG-1 ceramic-coated stainless steel as the most effective platform, offering strong adhesion and low resistance. Furthermore, electric field-assisted sintering (EFAS) was employed to embed the sensors into stainless steel 316L matrices without degrading their functionality. Post-embedding electrical tests confirmed sensor integrity, and initial characterization suggests strong potential for in-situ monitoring. This work provides a scalable strategy for integrating high-performance temperature sensors directly into refractory components, advancing embedded SHM technologies for harsh operating environments.

36 - MATERIALS SCIENCE↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a three-dimensional APOLLO3 neutrons deterministic scheme for the CABRI reactor

CABRI is an experimental reactor to study the fuel behavior during reactivity injection transients. These transients being highly multiphysics, the development of suitable modeling and simulation tools to simulate them is important for the optimization of the tests and the control of the experimental conditions. This paper focuses on the development of an APOLLO3 deterministic core calculation tool dedicated to the CABRI transient analysis. It represents the first stage of the incremental process for the implementation of a multiphysics time-dependent modeling of the CABRI transient. The neutron calculation scheme is based on a classical two-step approach. The first step consists of a 281-energy group calculation flux with the TDT-MOC (Method Of Characteristics) solver for cross-section space and energy (23 groups) collapsing for the CABRI different assembly clusters. The bias on a 2D core neutron calculation due to the self-shielding calculation and collapsing on a restricted pattern are investigated thanks to a comparison with a direct full 2D calculation on a quarter of core. The second step relies on a pin-resolved transport 3D transport core calculation with the SN solver MINARET. A progressive numerical validation process is followed to quantify the calculation biases on reactivity and reaction rates at each step using reference calculations with the stochastic code TRIPOLI4. The next development stage toward a multiphysics scheme will be the implementation of the 3D-kinetics equation resolution and the coupling with a core thermal-hydraulics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Leveraging Optimal Sparse Sensor Placement to Aggregate a Network of Digital Twins for Nuclear Subsystems

Nuclear power plants (NPPs) require continuous monitoring of various systems, structures, and components to ensure safe and efficient operations. The critical safety testing of new fuel compositions and the analysis of the effects of power transients on core temperatures can be achieved through modeling and simulations. They capture the dynamics of the physical phenomenon associated with failure modes and facilitate the creation of digital twins (DTs). Accurate reconstruction of fields of interest (e.g., temperature, pressure, velocity) from sensor measurements is crucial to establish a two-way communication between physical experiments and models. Sensor placement is highly constrained in most nuclear subsystems due to challenging operating conditions and inherent spatial limitations. This study develops optimized data-driven sensor placements for full-field reconstruction within reactor and steam generator subsystems of NPPs. Optimized constrained sensors reconstruct field of interest within a tri-structural isotropic (TRISO) fuel irradiation experiment, a lumped parameter model of a nuclear fuel test rod and a steam generator. The optimization procedure leverages reduced-order models of flow physics to provide a highly accurate full-field reconstruction of responses of interest, noise-induced uncertainty quantification and physically feasible sensor locations. Accurate sensor-based reconstructions establish a foundation for the digital twinning of subsystems, culminating in a comprehensive DT aggregate of an NPP.

42 ENGINEERING↗