Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Tapering-enhanced high-efficiency THz waveguide oscillator

Using a waveguide in a THz FEL has been shown to maximize the coupling and enable efficient extraction of relativistic electron beam energy from a single passage through a tapered helical undulator. An oscillator configuration can further boost energy extraction above the single-pass limits and open the door toward very high average power THz sources. Embedding the undulator in an oscillator cavity is particularly useful in combination with high repetition rate electron sources, even if at reduced peak brightness, since recycling a fraction of the radiation as an intense seed can compensate for lower single-pass gain. In this paper, we investigate the efficiency scaling of a tapering-enhanced waveguide oscillator, showcasing its capability for frequency-tuning operation and high-efficiency operation at different wavelengths. Using a thermionic-driven beamline equipped with compression elements, numerical start-to-end simulation results indicate a 16% efficiency at 200 GHz and a 2.1% efficiency at 1.5 THz, resulting in kW-level average power out-coupled in radiation pulses with few hundred μ J energy and tens of MW peak power. Published by the American Physical Society 2024

Yang, Y. N. (ORCID:0009000849540151)↗

Security proof of practical quantum key distribution with detection-efficiency mismatch

Quantum key distribution (QKD) protocols with threshold detectors are driving high-performance QKD demonstrations. The corresponding security proofs usually assume that all physical detectors have the same detection efficiency. However, the efficiencies of the detectors used in practice might show a mismatch depending on the manufacturing and setup of these detectors. A mismatch can also be induced as the different spatial-temporal modes of an incoming signal might couple differently to a detector. Here we develop a method that allows to provide security proofs without the usual assumption. Our method can take the detection-efficiency mismatch into account without having to restrict the attack strategy of the adversary. Especially, we do not rely on any photon-number cutoff of incoming signals such that our security proof is directly applicable to practical situations. We illustrate our method for a receiver that is designed for polarization encoding and is sensitive to a number of spatial-temporal modes. In our detector model, the absence of quantum interference between any pair of spatial-temporal modes is assumed. For a QKD protocol with this detector model, we can perform a security proof with characterized efficiency mismatch and without photon-number cutoff assumption. Our method also shows that in the absence of efficiency mismatch in our detector model, the key rate increases if the loss due to detection inefficiency is assumed to be outside of the adversary's control, as compared to the view where for a security proof this loss is attributed to the action of the adversary.

97 MATHEMATICS AND COMPUTING↗

Dynamical Sketching for Enhanced Communication Efficiency in Federated Learning

Federated learning (FL) has revolutionized distributed machine learning by enabling collaborative model training without sharing local data. However, communication efficiency and privacy guarantees remain significant challenges. This paper introduces a dynamic sketching mechanism in FL, optimizing the trade-off between communication efficiency and model accuracy. By dynamically selecting the sketch matrix size, our approach adapts to the evolving characteristics of the data and the model, ensuring optimal performance across diverse scenarios. We leverage Bayesian optimization to systematically tune the sketch parameters, achieving an effective balance between resource efficiency and model performance. Experimental results on the MNIST dataset using a convolutional neural network (CNN) architecture validate the proposed method's efficiency and scalability. Our dynamic sketching approach significantly outperforms fixed-size sketching techniques, achieving higher compression ratios (up to 62x) and providing better privacy guarantees while maintaining high model accuracy. These findings highlight the robustness and versatility of our approach and make it a valuable solution for privacy-preserving, communication-efficient federated learning.

Afrose, Sharmin [ORNL]↗

A Comparison of the Optoelectronic Properties of High-Efficiency Polycrystalline and Epitaxial Cu(In,Ga)Se2 Photovoltaic Films

Over the last several decades, champion photovoltaic (PV) devices using CuInGaSe2 (CIGS) as the absorber material have been achieved using polycrystalline films exclusively. This has led to the assumption that polycrystalline CIGS generally outperform single-crystal CIGS in PV devices. However, recently, very high-quality epitaxial CIGS has been grown on GaAs substrates producing PV device efficiencies of 20.0%. These results have revived the debate on what effects grain boundaries have on PV device efficiencies. In this contribution, we compare the optoelectronic properties of polycrystalline CIGS films with those of high-efficiency epitaxial CIGS films. This comparison reveals that grain boundaries are associated with properties that negatively impact PV device efficiency. Additionally, we find that the grain interiors in polycrystalline films exhibit properties that are similar to the high-performance epitaxial films. Our results suggest that it may be possible to achieve higher device efficiencies with epitaxial CIGS than with polycrystalline films.

41 EE - Solar Energy Technologies Office (EE-4S)↗

LiCl–Based Aqueous Electrolytes for Efficient Iron Electrodeposition

This study investigates room temperature, aqueous electrolytes for efficient iron electrodeposition. Specifically, a novel lithium chloride-based electrolyte was identified to suppress hydrogen evolution while promoting fast kinetics of iron electrodeposition, achieving high coulombic efficiency (>90%) at high current densities (>400 mA cm −2 ). Electrochemical analysis of the partial current densities of iron deposition and hydrogen co-evolution revealed that water reduction is kinetically suppressed in this electrolyte, resulting in an increase in the measured coulombic efficiency. Furthermore, a detailed investigation of the iron speciation and their complexation was performed, which revealed that, in concentrated LiCl-containing electrolytes, the ferrous (Fe 2+ ) species coordinate with chloride rather than water, enhancing deposition kinetics. The combined effect of enhanced electrodeposition kinetics and suppressed water activity provide elevated coulombic efficiency. Overall, this paper develops an understanding of anion and cation effects on the mechanism of electrodeposition and hydrogen co-evolution in concentrated electrolytes in search of improved aqueous media (e.g., concentrated LiCl) for efficient metal electro-synthesis.

Lvovich, William [Case Western Reserve University,↗

Spectral Efficiency and Tandem Performance Calculators [SWR-24-92]

The Spectral Efficiency and Tandem Performance Calculators allow users to test material types for use in tandem photovoltaic devices to better understand if a given material could work well. The Spectral Efficiency (SE) calculator takes a set of current vs voltage (I-V) and quantum efficiency (QE) data along with a spectrum input and plots the spectral efficiency of the cells represented by the datasets for the spectrum provided. The Tandem Performance calculator uses the calculated spectral efficiency of top and bottom cells and the transmission data of the top cell to calculate performance metrics for a tandem device in either a two or four terminal architecture. The SE and Tandem Performance calculators are based on the following publication: Yu, Z., Leilaeioun, M. & Holman, Z. Selecting tandem partners for silicon solar cells. Nat Energy 1, 16137 (2016).

Warren, Emily↗

Chlorophyll fluorescence imaging captures photochemical efficiency of grain sorghum (Sorghum bicolor) in a field setting

Abstract Background Photosynthesis is one of the most important biological reactions and forms the basis of crop productivity and yield on which a growing global population relies. However, to develop improved plant cultivars that are capable of increased productivity, methods that can accurately and quickly quantify photosynthetic efficiency in large numbers of genotypes under field conditions are needed. Chlorophyll fluorescence imaging is a rapid, non-destructive measurement that can provide insight into the efficiency of the light-dependent reactions of photosynthesis. Results To test and validate a field-deployed fluorescence imaging system on the TERRA-REF field scanalyzer, leaves of potted sorghum plants were treated with a photosystem II inhibitor, DCMU, to reduce photochemical efficiency (F V /F M ). The ability of the fluorescence imaging system to detect changes in fluorescence was determined by comparing the image-derived values with a handheld fluorometer. This study demonstrated that the imaging system was able to accurately measure photochemical efficiency (F V /F M ) and was highly correlated ( r = 0.92) with the handheld fluorometer values. Additionally, the fluorescence imaging system was able to track the decrease in photochemical efficiency due to treatment of DCMU over a 7 day period. Conclusions The system’s ability to capture the temporal dynamics of the plants’ response to this induced stress, which has comparable dynamics to abiotic and biotic stressors found in field environments, indicates the system is operating correctly. With the validation of the fluorescence imaging system, physiological and genetic studies can be undertaken that leverage the fluorescence imaging capabilities and throughput of the field scanalyzer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data for Miscanthus giganteus Biolistic Transformation Using the Visible RUBY Red Marker Gene to Monitor Transformation Efficiency

Miscanthus × giganteus ( M × g ) is a high- yielding perennial C4 bioenergy crop, but genetic improvement by breeding is constrained by triploid sterility and clonal propagation. Improving genetic transformation methods for M × g would provide opportunities for advantageous trait introgression. Use of an easy to phenotype reporter gene is a promising strategy to improve transformation processes and efficiency. This study presents an efficient novel method for biolistic transformation of inflorescence- derived callus in M × g and demonstrates its efficacy using RUBY, a betalain-based noninvasive reporter that is visible throughout the transformation process. RUBY expression ( Zea mays codon optimized) was visible from callus stage through plantlet development into maturity. RUBY expressing independently transformed plants were confirmed by hygromycin phosphotransferase ELISA and by genomic PCR demonstrating that the RUBY phenotype is sufficient for screening transformants. The Zea mays codon optimized hygromycin selection marker was driven by previously established promoters for Miscanthus, ZmUBI and 2×35S, while the RUBY gene expression was controlled by a known Zea mays C4 promoter, Brachypodium UBI10, newly employed in Miscanthus. The construct containing the 2×35S promoter for hygromycin had a 15.1% transformation efficiency while the ZmUBI promoter had a 20.5% transformation efficiency. This study provides a novel, highly efficient protocol for successful biolistic transformation of M × g for stable expression. This study also demonstrates that RUBY expression can be used as a convenient and powerful monitor of transformation in ongoing and future work to engineer M × g into an improved bioproduct feedstock. **NOTE: in "TableS2_ProtocolComparison.csv", the data from row 665 to 971 should be removed.

Gene Editing↗

PINE: Photonic Integrated Networked Energy efficient datacenters

We review the motivation, goals, and achievements of the Photonic Integrated Networked Energy efficient datacenter (PINE) project, which is part of the Advanced Research Projects Agency–Energy (ARPA-E) ENergy-efficient Light-wave Integrated Technology Enabling Networks that Enhance Dataprocessing (ENLITENED) program. Here, the PINE program leverages the unique features of photonic technologies to enable alternative mega-datacenters and high-performance computing (HPC) system architectures that deliver more substantial energy efficiency improvements than can be achieved through link energy efficiency alone. In phase 1 of the program, the PINE system architecture demonstrated an average factor of 2.2× improvement in transactions/joule across a diverse set of HPC and datacenter applications. In phase 2, PINE will demonstrate an aggressive 1.0 pJ/bit total link budget with high-bandwidth-density dense wavelength-division multiplexing (DWDM) links to enable additional 2.5× or more efficiency gains through deep resource disaggregation.

42 ENGINEERING↗

Highly efficient visible and near-IR photon pair generation with thin-film lithium niobate

Efficient on-chip entangled photon pair generation at telecom wavelengths is an integral aspect of emerging quantum optical technologies, particularly for quantum communication and computing. However, moving to shorter wavelengths enables the use of more accessible silicon detector technology, and opens up applications in imaging and spectroscopy. Here, we present high brightness ((1.6 ± 0.3) × 10 9 pairs/s/mW/nm) visible–near-IR photon pair generation in a periodically poled lithium niobate nanophotonic waveguide. The degenerate spectrum of the photon pairs is centered at 811 nm with a bandwidth of 117 nm when pumped with a spectrally multimode laser diode. The measured on-chip source efficiency of (2.3 ± 0.5) × 10 11 pairs/s/mW is on par with source efficiencies at telecom wavelengths and is also orders of magnitude higher than the efficiencies of other visible sources implemented in bulk crystal or diffused waveguide-based technologies. Further improvements in the brightness and efficiencies are possible by pumping the device with a single-frequency laser, which would also shrink the pair bandwidth. These results represent the shortest wavelength of photon pairs generated in a nanophotonic waveguide reported to date by nearly an octave.

42 ENGINEERING↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Expanding the Knock/Emissions/Misfire Limits for the Realization of Ultra-Low Emissions, High Efficiency Heavy Duty Natural Gas Engines

The Vehicle Technologies Office funds early-stage, high-risk research to develop technology upon which industry can implement innovative transportation energy technologies that increase efficiency, decrease cost, and expand use of domestic energy sources, such as natural gas (NG). To improve the viability of medium and heavy-duty vehicles the natural gas engine efficiency must be closer to that of diesel. This work addresses fundamental limitations to achieve diesel-like efficiencies in heavy duty on-road natural gas engines. The primary goal of this research is to achieve diesel-like efficiencies in heavy duty on-road NG engines, focusing on the Cummins 15 liter engine platform (baseline diesel efficiency of 44% at peak torque). That goal has been achieved, though more work is needed to facilitate practical implementation of the developed technologies.

03 NATURAL GAS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

National and Regional Initiatives to Promote Energy Efficiency and Renewable Energy Through State Energy Offices

The National Association of State Energy Officials (NASEO) worked with the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE), Weatherization and Intergovernmental Programs Office (WIP) over a ten year period to provide technical assistance, research and analyses, and enhanced coordination between DOE and the State and Territory Energy Offices. Over the life of the agreement, NASEO worked with WIP and the states to provide statewide strategic energy plan analyses and recommendations, including customized technical assistance to the states; peer to peer financing assistance via NASEO’s Financing Committee and supporting activities; training on core energy policies and programs, including dialogues and resources to support energy-air coordination, a training for new State Energy Office Directors, peer to peer exchange via a rural energy taskforce, and support to states to enhance buildings efficiency, home energy labeling, and technology deployment opportunities; support for State Energy Program metrics; and regional coordination via regional coordinators and peer exchange opportunities both in-person and online. Over the life of the project, the position and role of State Energy Offices within state government has changed, with now 80 percent of State Energy Office Directors serving as their Governor’s energy advisor, or reporting directly to their Governor’s energy advisor. This shift in stature has made it ever more crucial for State Energy Offices to receive timely and relevant technical assistance across a range of energy issue areas. NASEO, in collaboration with WIP, was able to deliver this technical assistance, and energy efficiency and renewable energy deployment has accelerated across the country. The State Energy Office Directors and their staff continue to engage in NASEO’s Committees – many of which were supported through this agreement – and have provided formal and informal feedback on the value of the programs supported through this award (e.g., reporting via survey increased understanding of their roles and technical assistance offerings provided by WIP and NASEO following the New Director Trainings). Moreover, resources developed through this award (e.g., Comprehensive State Energy Planning Guidelines, State Energy Loan Fund Database, Rural Data Resources for State Energy Planning and Programs, The Value of Adding home Energy Score to Low-Income Energy Efficiency Programs, etc.) have been cited by states as instrumental to their understanding of specific energy issue areas and in many cases led directly to enhanced program design within a state (e.g. Iowa citing their review of NASEO’s Comprehensive State Energy Planning Guidelines as a necessary first step in their planning process, later following may of the steps outlined in the guidelines). The priorities of the states and federal government have evolved over the last decade, with an increasing focus on climate mitigation and adaptation, equity impacts and considerations, energy security and resilience, and enhanced energy efficiency and renewable energy technology deployment, but the roots of these new priorities are based in the state and federal policies and programs, and research and analyses, that were supported in part through this award and other complementary initiatives. NASEO looks forward to continuing to support the states, and collaborate and coordinate with DOE, as we build on this important foundation in the years ahead.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Maneuvering of Connected and Automated Vehicles (CAVs) with Situational Awareness at Intersections (Final Progress Report)

The increased development of Connected and Automated Vehicle (CAV) systems, currently used for safety and driver convenience, presents new opportunities to improve the energy efficiency of vehicles. Southwest Research Institute (SwRI) achieved a 20% energy consumption reduction in a 2017 Toyota Prius Prime plug-in hybrid by using connectivity (V2V, V2I, V2X) as part of the Next Generation Energy Technologies for Connected and Automated on-Road Vehicles (NEXTCAR) program. The energy consumption gains were achieved by a combination of vehicle dynamics and powertrain control algorithms with a focus on SAE L1 and L2 automated vehicles where a human is still responsible for safe operation. SwRI is now involved in NEXTCAR-II, focusing on energy-efficient control tech for SAE Level 4/5 automated vehicles, aiming for a 30% energy reduction compared to stock hybrids. The rise of Mobility as a Service (MaaS) is driving investments in L4 and L5 automated vehicles. A study by the University of Michigan shows these vehicles might increase energy use and emissions by 3-20%. Technology similar to NEXTCAR can enhance energy efficiency in highly automated vehicles, leveraging improved sensing and actuation capabilities. While the NEXTCAR programs targeted energy efficiency improvements for a single vehicle, this program adopts a more expansive approach. It places its focus on understanding and testing the cumulative effects within a region or corridor, aiming to assess how a subset of vehicles equipped with NEXTCAR-style technologies influence the overall energy consumption of all vehicles traveling within that area. Additionally, the program explores infrastructure-based mobility solutions to optimize efficiency, and seeks to understand and quantify public perception and likelihood of technology adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗