Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy systems optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Development, Monitoring, and Control of Fracture Thermal Energy Storage (FTES) in Crystalline Rock Formations (DEMO-FTES) (CRADA Final Report)

The DEMO-FTES project sought to demonstrate the thermal efficiency of fracture thermal energy storage (FTES) through numerical simulations, laboratory and meso-scale field tests. A detailed dimensional and scaling analysis was performed to identify key parameters and how they can be most effectively scaled to the laboratory and decameter scale. Numerical models were developed and used for three purposes: 1. Before field experiments, numerical modelling can be used to estimate fracture properties based on previous data from the EGS Collab experiment and then predict thermal hydrological behaviors of the fracture system with hot water injection/withdrawal, therefore, help to design the experiments (e.g., to decide the duration of the cycles based on the flow rate the pump can provide, and the estimated fracture properties); 2. After the field experiment, to estimate the system properties during the experiment (as the size and shape of a fracture could change over time), and understand why system performance is different than what has been predicted, i.e., to help understand the meso-scale test; and, 3. To model the lab experiments and estimate fracture properties and storage efficiency. Ultimately, the experiment and numerical models could shed light on the processes and uncertainty happening during fracture activation and help understand the scaling between lab and field test, and finally, the design and optimization of potential fracture thermal energy storage systems.

25 ENERGY STORAGE↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supercritical water desalination and oxidation (SCWDO): Effectiveness on complex solutions, technoeconomic, and CO 2 impact for produced water treatment

The modern energy-economy is increasingly causing the production of highly saline brines, including from produced water. Supercritical water desalination can concentrate and extract minerals from these brines, but the effects of mixed salt interactions, organic degradation with additives, and the technology's economics are not well understood at supercritical condition. The present study evaluated and experimentally studied an integrated supercritical water desalination and oxidation (SCWDO) process for treating real-produced water samples from oil/natural gas field. The complex interactions between the various anions and cations in produced water were extensively evaluated. Most of the divalent and trivalent ions were extracted below 250 °C while the majority of the monovalent salt were removed between 380 to 410 °C. The treated real produced water was of drinking water quality, with <500 mg/l of total dissolved solid (TDS) and with 100% organics removal. Furthermore, the heat liberated during the organic oxidation could be utilized internally and for electricity generation for enhanced the energy efficiency and lower cost of produced water treatment. With system optimization, the proposed SCWDO process can essentially be made a net zero energy process. A novel process flow diagram for the commercial scale self-powered hybrid SCWDO technology was proposed as a cost-effective produced water treatment to mitigate the environmental crises. Techno-economic analysis showed that produced water treatment cost with SCWDO can be reduced to 2–3 $/m 3 and can be up to 60 % cheaper to traditional deep well reinjection. Additionally, the proposed SCWDO process could achieve net negative CO 2 emission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization Studies for the Long-Baseline Neutrino Facility at Fermilab

The Deep Underground Neutrino Experiment and Long-Baseline Neutrino Facility (DUNE-LBNF) are under development at Fermilab since early 2010s [1]. At present, the work is being performed towards a comprehensive review conducted by US Department of Energy (DOE)-the Critical Decision 2 (CD-2)-that is planned to take place in the middle of 2022. The primary scientific objectives of DUNE are to carry out a comprehensive investigation of neutrino oscillations to test CP violation in the lepton sector, determine the ordering of the neutrino masses, and to test the three-neutrino paradigm (electron, muon and tau neutrino). The LBNF will provide a 120-GeV proton beam on a neutrino production target utilizing a new 800-MeV superconducting Linac which is expected to be completed in 2027 [2]. The neutrino beamline, which utilizes a target and horn systems, decay pipe, hadron absorber and other systems, is a core component of the LBNF. At present-as a result of numerous iterations-there exists an optimized design with a 1.5-m graphite target and focusing system consisting of three horns. Further optimization energy deposition and radiological calculations are performed towards CD-2 and beyond. This paper describes results of the most recent MARS15 [3] optimization studies.

43 PARTICLE ACCELERATORS↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

A two-dimensional analytical unit cell model for redox flow battery evaluation and optimization

Cell performance optimization is important for improving the overall system efficiency of a redox flow battery. To gain better insights into key controlling factors of system efficiency, this work first proposed a theoretical model for a unit flow battery cell by extending a two-dimensional analytic model to a full battery cell. Such a model is then used for cell performance optimization after validating it with experimental and numerical modeling data. With the model results, the activation, equilibrium, and pump energy losses are identified as the dominant sources of battery energy losses. Further, a guideline for reducing these sources is also proposed. Following the guideline, the mass transport coefficient is shown as a key control factor of the equilibrium energy loss and Coulombic efficiency (CE). Approaches are then proposed to improve CE and the overall system efficiency. The mass transport is also revealed as the mechanism of pump rate optimization where an optimal pump rate significantly reduces the equilibrium energy loss. With both low equilibrium and pump energy losses, an optimal electrode porosity or specific area design can further improve a battery's system efficiency based on an optimal porosity predicted by the present model. The model also demonstrates distinct behaviors and overestimation in the system efficiency when reduced to a zero-dimensional model with neglected mass transport resistance. With the new model, the guideline, and new insights, this work provides a reliable and efficient tool for the evaluation and optimization of redox flow battery design in practical applications.

25 ENERGY STORAGE↗

Discharge Rate‐Driven Li 2 O 2 Growth Exhibits Unconventional Morphology Trends in Solid‐State Li‐O 2 Batteries

Solid-state lithium oxygen batteries (LOBs) are known for their enhanced safety, higher electrochemical stability, and improved energy density compared to liquid-state LOBs. However, the investigation of solid-state LOBs is limited with little understanding of their discharge and charge processes. In this work, a polymer-based solid-state LOB is used to investigate the effect of discharge rate on lithium peroxide (Li 2 O 2 ) formation, the oxygen evolution reaction (OER), and cycle performance. Notably, we observe a counterintuitive trend: Li 2 O 2 particle size increases with increasing discharge current density, in contrast to liquid systems. This behavior arises from inherent space charge layers that restrict Li⁺ transport under high current, and spatially heterogeneous active sites at the solid electrolyte–cathode interface, directly evidenced by small angle X-ray scattering (SAXS), which govern nucleation accessibility and promote site-selective Li 2 O 2 growth. Furthermore, higher current densities improve ORR and OER efficiency but accelerate anode degradation, while lower currents promote side reactions. These opposing effects result in a trade-off that defines an optimal discharge rate (0.1 mA cm -2 ) for maximizing cycle life. This study provides a new mechanistic perspective on discharge-driven processes in solid-state LOBs and offers practical guidelines for performance optimization in future high-energy battery systems.

Discharge current density↗

Optimal carbon storage reservoir management through deep reinforcement learning

Model-based optimization plays a central role in energy system design and management. The complexity and high-dimensionality of many process-level models, especially those used for geosystem energy exploration and utilization, often lead to formidable computational costs when the dimension of decision space is also large. This work adopts elements of recently advanced deep learning techniques to solve a sequential decision-making problem in applied geosystem management. Specifically, a deep reinforcement learning framework was formed for optimal multiperiod planning, in which a deep Q-learning network (DQN) agent was trained to maximize rewards by learning from high-dimensional inputs and from exploitation of its past experiences. To expedite computation, deep multitask learning was used to approximate high-dimensional, multistate transition functions. Both DQN and deep multitask learning are pattern based. As a demonstration, the framework was applied to optimal carbon sequestration reservoir planning using two different types of management strategies: monitoring only and brine extraction. Both strategies are designed to mitigate potential risks due to pressure buildup. Results show that the DQN agent can identify the optimal policies to maximize the reward for given risk and cost constraints. Finally, experiments also show that knowledge the agent gained from interacting with one environment is largely preserved when deploying the same agent in other similar environments.

15 GEOTHERMAL ENERGY↗

Universal energy-speed-accuracy trade-offs in driven nonequilibrium systems

The connection between measure theoretic optimal transport and dissipative nonequilibrium dynamics provides a language for quantifying nonequilibrium control costs, leading to a collection of thermodynamic speed limits, which rely on the assumption that the target probability distribution is perfectly realized. This is almost never the case in experiments or numerical simulations, so here we address the situation in which the external controller is imperfect. We obtain a lower bound for the dissipated work in generic nonequilibrium control problems that (1) is asymptotically tight and (2) matches the thermodynamic speed limit in the case of optimal driving. Along with analytically solvable examples, we refine this imperfect driving notion to systems in which the controlled degrees of freedom are slow relative to the nonequilibrium relaxation rate, and identify independent energy contributions from fast and slow degrees of freedom. Furthermore, we develop a strategy for optimizing minimally dissipative protocols based on optimal transport flow matching, a generative machine learning technique. Furthermore, this latter approach ensures the scalability of both the theoretical and computational framework we put forth. Crucially, we demonstrate that we can compute the terms in our bound numerically using efficient algorithms from the computational optimal transport literature and that the protocols we learn saturate the bound.

59 BASIC BIOLOGICAL SCIENCES↗

A comprehensive review on regeneration strategies for direct air capture

Direct air capture (DAC), which removes CO 2 directly from ambient air, is a critical negative emission technology for mitigating global climate change. Efficiency and the source of energy are crucial considerations for DAC to enable negative emissions. Substantial technological progress has been made in DAC technologies, and promising opportunities exist for commercial-scale deployments. However, DAC technologies require high regeneration energy to release CO 2 from sorbents. Various approaches have been tested and optimized for different DAC systems. This review demonstrates that the work equivalent regeneration energy demand (supported by either the electric grid or fossil fuel combustion) ranges from 0.5–18.75 GJ/t-CO 2 for solid sorbent DAC systems and 0.62–17.28 GJ/t-CO 2 for liquid solvent DAC systems. The regeneration process is the energy-demanding process in DAC that is a key step for efficient operation. Potential methods to lower the regeneration energy demand include microwave, ultrasound, magnetic particle heating, and electric swing. Although the potential methods to date are still at the lab scale, significant work is being done to optimize DAC system processes.

54 ENVIRONMENTAL SCIENCES↗

Microgrid Assisted Design for Remote Areas

In this work, we present a three-stage multiobjective mixed-integer linear programming (MILP) for the optimal expansion planning and operation of isolated multienergy microgrids in remote areas. By selecting the optimal distributed generators (DGs) and energy storage systems (ESSs) mix selection, siting, sizing, and scheduling in the remote microgrid, the proposed model is targeted to minimize the annualized total cost of microgrids while enhancing the performance of the system, i.e., minimizing the voltage deviations and line power loss. To represent the electricity and heat flow between generation resources and various electrical, heating, and cooling loads in the isolated microgrid, linearized power flow, and heat flow constraints are employed in the proposed optimization model. The available capacity of DGs and ESSs are modeled as discrete constants instead of continuous variables for practical purpose. Numerical simulation results on a remote microgrid consisting of DGs, ESSs, and various loads validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method of evaluating change in energy consumption due to Volt VAR optimization

A method of evaluating an optimization system is disclosed. The system is transitioned from an on state to an off state. Data is collected at time intervals for a time period before and after the system is transitioned from the on state to the off state. The transitioning occurs while a load of a particular type is active. In one embodiment, the optimization system is a Volt/VAR Optimization (VVO) system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

CPES-QSM: A Quantitative Method Towards the Secure Operation of Cyber-Physical Energy Systems

Power systems are evolving into cyber-physical energy systems (CPES) mainly due to the integration of modern communication and Internet-of-Things (IoT) devices. CPES security evaluation is challenging since the physical and cyber layers are often not considered holistically. Existing literature focuses on only optimizing the operation of either the physical or cyber layer while ignoring the interactions between them. This paper proposes a metric, the Cyber-Physical Energy System Quantitative Security Metric (CPES-QSM), that quantifies the interaction between the cyber and physical layers across three domains: electrical, cyber-risk, and network topology. A method for incorporating the proposed cyber-metric into operational decisions is also proposed by formulating a cyber-constrained AC optimal power flow (C-ACOPF) that considers the status of all the CPES layers. The C-ACOPF considers the vulnerabilities of physical and cyber networks by incorporating factors such as voltage stability, contingencies, graph-theory, and IoT cyber risks, while using a multi-criteria decision-making technique. We note that simulation studies are conducted using standard IEEE test systems to evaluate the effectiveness of the proposed metric and the C-ACOPF formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydroboost

HydroBoost is the most realistic revenue optimization tool for the hybridization of hydropower and battery energy storage systems to date. The innovative representation of how operators actually schedule hydropower in practice results in more realistic predictions of revenue and operations. Unlike other optimization tools, HydroBoost generates forecast energy prices with uncertainty to use in the optimization. This allows HydroBoost to give users a range of potential revenue with an upper bound using the perfect foresight pricing and a lower bound using a naive persistence forecast model. Additional forecast can be generated and used in the optimization, such as additive models, random forest, and neural networks to give further insight into potential revenue. HydroBoost has been designed to be applicable for both run-of-river and reservoir storage sites. The primary focus is on the day-ahead market and requires year-long data with an hour time-step. All time-series input and constraints are contained in an Excel worksheet for convince. The user will run the forecasting generation first with a Python script to give the optimization model the necessary requirements. Next the optimization is ran using Julia and results are generated and stored into a directory as csv files. HydroBoost includes an additional module to generate figures based on the results of the optimization simulation. The results help analyze the results and users to draw insights into how the hydro and battery systems are operated and the revenue each is producing. Additionally, the difference between the perfect foresight model and models that include forecast can easily be inspected.

Phillips, TylerB. [Idaho National Laboratory (INL)↗

Methods, systems, and devices to optimize a fluid harvester

An apparatus for energy extraction from fluid flow including an assembly including a plenum. The assembly further includes an aperture extending from an exterior surface to the plenum to allow flow therethrough. The apparatus further includes a channel including an inlet and an outlet in fluid communication with the plenum. The apparatus yet further includes an energy extraction device. The assembly is configured to create a pressure differential between the plenum and the inlet of the channel. The pressure differential causes fluid flow from the inlet of the channel to the plenum. The energy extraction device is configured to extract energy from the fluid flow. The apparatus additionally includes a control system configured to modify the pressure differential to control the fluid flow between the inlet of the channel and the plenum based on a characteristic of an exterior environment.

Houchens, Brent Charles↗