Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Integrated Pumped Thermal and Liquid Air Energy Storage

Liquid air energy storage (LAES) and pumped thermal energy storage (PTES) are two closely related technologies that employ thermodynamic cycles to store electricity in the form of thermal energy. This chapter describes the integration of PTES and LAES in a single combined cycle (PT-LAES), where the PTES side provides the cold source required to drive the air liquefaction process. This presents several advantages compared to the separate cycles, including the partial or complete removal of cold stores, a higher energy density and the achievement of full air liquefaction. Notably, PT-LAES does not depend on external sources of heat or cold and thus constitutes a stand-alone system. As a result, PT-LAES can also be viewed as an advanced LAES cycle with full liquefaction.

Carnot batteries↗

Assessing geothermal/solar hybridization – Integrating a solar thermal topping cycle into a geothermal bottoming cycle with energy storage

Geothermal and concentrating solar power (CSP) technologies typically use heat at different temperatures in their commercial deployments. This enables a technically viable hybridization of a solar topping cycle and a geothermal bottoming cycle at locations where both resources are available. In this article, an underperforming geothermal power system based at Burley, Idaho is used as a baseline to investigate the technical and economic potential of such a hybrid cycle. A direct thermal energy storage (TES) system is also integrated to overcome the intermittency of the solar resource. Design and off-design behavior of key components are modelled to simulate the annual performance of the hybrid system on an hourly basis. The sizing of the solar field and thermal storage is investigated and is seen to significantly impact the annual electricity generation and efficiency. Various cost scenarios for the solar field and thermal energy storage are investigated. An economic metric - levelized cost of electricity (LCOE) - is used to optimize the solar field sizing and TES capacity. The hybrid plant converts the additional solar heat input into additional work with an efficiency of 32.9%. Retrofitting a geothermal plant with solar and eight hours of energy storage can achieve an LCOE of 0.136 $/kWhe in current cost scenarios and 0.081 $/kWhe in a future cost reduction scenario. Although the hybrid system cannot directly compete with current PV systems without batteries, it has an LCOE 32% lower than that of a PV-battery system. This paper provides insights into the research and development of the future grid with a high renewable energy penetration and encourages further study of energy hybridization for improved efficiencies and economics.

15 GEOTHERMAL ENERGY↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

The world’s largest liquid hydrogen storage tanks were constructed in the mid-1960sat the NASA Kennedy Space Center. These two vacuum-jacketed, perlite powder insulated tanks, still in service today, have 3,200 m3 of useable capacity. In 2018, construction began on an additional storage tank at Launch Complex 39B. This new tank will give an additional storage capacity of 4,700 m3 for a total on-site storage capacity of roughly 8,000 m3. NASA’s new Space Launch System (SLS) heavy lift rocket for the Artemis program includes an LH2tank that makes up the bulk of the vehicle, holding 2,033 m3 of LH2 in its 8.4-m diameter by40-m height. The new storage tank includes two new energy-efficient technologies: a glass bubbles insulation system in lieu of perlite, and an Integrated Refrigeration and Storage (IRAS)heat exchanger for controlled storage capability. The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46%versus perlite in field demonstrations. The IRAS capability is centered on a heat exchanger system that is built within the inner vessel to reject heat from the bulk liquid through the future implementation of an external helium refrigerator. Controlled storage via IRAS, when fully implemented, will provide full control of the ullage pressure, zero boiloff, and even production of densified LH2 pending its adoption on future launch vehicles. The design basics are described along with main construction and testing processes involved. The key features of the new technology items and implications on simplified operations and long-term energy savings are addressed

cryogenics↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

NASA Tech Briefs, January 2007

Topics covered include: Flexible Skins Containing Integrated Sensors and Circuitry; Artificial Hair Cells for Sensing Flows; Video Guidance Sensor and Time-of-Flight Rangefinder; Optical Beam-Shear Sensors; Multiple-Agent Air/Ground Autonomous Exploration Systems; A 640 512-Pixel Portable Long-Wavelength Infrared Camera; An Array of Optical Receivers for Deep-Space Communications; Microstrip Antenna Arrays on Multilayer LCP Substrates; Applications for Subvocal Speech; Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply; The PICWidget; Fusing Symbolic and Numerical Diagnostic Computations; Probabilistic Reasoning for Robustness in Automated Planning; Short-Term Forecasting of Radiation Belt and Ring Current; JMS Proxy and C/C++ Client SDK; XML Flight/Ground Data Dictionary Management; Cross-Compiler for Modeling Space-Flight Systems; Composite Elastic Skins for Shape-Changing Structures; Glass/Ceramic Composites for Sealing Solid Oxide Fuel Cells; Aligning Optical Fibers by Means of Actuated MEMS Wedges; Manufacturing Large Membrane Mirrors at Low Cost; Double-Vacuum-Bag Process for Making Resin- Matrix Composites; Surface Bacterial-Spore Assay Using Tb3+/DPA Luminescence; Simplified Microarray Technique for Identifying mRNA in Rare Samples; High-Resolution, Wide-Field-of-View Scanning Telescope; Multispectral Imager With Improved Filter Wheel and Optics; Integral Radiator and Storage Tank; Compensation for Phase Anisotropy of a Metal Reflector; Optical Characterization of Molecular Contaminant Films; Integrated Hardware and Software for No-Loss Computing; Decision-Tree Formulation With Order-1 Lateral Execution; GIS Methodology for Planning Planetary-Rover Operations; Optimal Calibration of the Spitzer Space Telescope; Automated Detection of Events of Scientific Interest; Representation-Independent Iteration of Sparse Data Arrays; Mission Operations of the Mars Exploration Rovers; and More About Software for No-Loss Computing.

Source record↗

Federated Access from DOE Labs to Distributed Storage in the EIC Era of Computing

The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Case Study of the City of Reno: Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City of Reno's efforts to quantify the value of resilience and the entrepreneurial ways through which the City approached the questions of what role solar and storage could play in their resilience efforts and how to value and pay for solar-plus-storage systems. It documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

New Matrix Framework to Determine Carbon Storage Technical Viability

Carbon storage is an integral component of reducing CO2 emissions. Research over the past two decades has developed workflows for volume assessments and economic project feasibility, providing necessary and useful tools to progress geologic carbon storage (GCS) projects. These workflows and assessments have focused primarily on determining the in-situ storage resource based on geologic and engineering parameters and do not integrate subsurface characterization with surface conditions, social factors, and environmental factors that may pose a benefit or impediment to the implementation of GCS. Furthermore, the data required to assess the technical viability of GCS are myriad and disparate. There is no current methodology that identifies technical viability criteria and systematically informs how to aggregate these factors for spatial assessments. To address this gap, the National Energy Technology Laboratory has developed a Carbon Storage Technical Viability Approach (CS TVA) Matrix that incorporates a wide variety of factors to inform and accelerate screening for GCS site selection in the United States.

Mulhern, Julia↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

IOTA Run 2 Beam Dynamics Studies in Nonlinear Integrable Systems

Nonlinear integrable optics is a promising design approach for suppressing fast collective instabilities. To study it experimentally, a new storage ring, the Integrable Optics Test Accelerator (IOTA), was built at Fermilab. IOTA has recently completed its second scientific run, incorporating many hardware and instrumentation improvements. This report presents the results of the two integrable optics experiments - the quasi-integrable Henon-Heiles octupole system and the fully integrable Danilov-Nagaitsev system. We demonstrate tune spread and dynamic aperture in agreement with tracking simulations, and a stable crossing of the integer resonance. Based on recovered single-particle phase space dynamics, we show improved invariant jitter consistent with intended effective Hamiltonian. We conclude by outlining future plans and efforts towards proton studies and larger designs.

43 PARTICLE ACCELERATORS↗

Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City's project evolution and the entrepreneurial ways through which the City approached the questions of how solar and storage could support their resilience efforts and how to value and pay for solar-plus-storage systems. This report documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. (The City of Reno applied for and was awarded FEMA BRIC funding in January 2021; leveraging work that was underway in this project.) This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗

A 150-kW 99% Efficient All-Silicon-Carbide Triple-Active-Bridge Converter for Solar-Plus-Storage Systems

Solar-plus-storage systems could effectively mitigate the uncertainties of the photovoltaic (PV) generation and improve system reliability by adding an integrated battery energy storage system. As a three-port bidirectional isolated dc–dc converter with soft-switching capability, the triple-active-bridge (TAB) converter inherently matches the requirements of the solar-plus-storage system. However, challenges still remain in the TAB converter design to further improve system efficiency. In this article, the detailed design, implementation, and demonstration for a silicon carbide (SiC) 150-kW TAB converter are presented. Starting from a brief review of the TAB converter, the modulation scheme, power characteristics, and soft-switching region are analyzed. Then, the detailed design of the H-bridge converter building block is given. Here, to improve the system efficiency, a comprehensive characterization of the SiC gate driver with various external gate resistances is performed to address tradeoffs between switching loss and voltage overshoot during transients, as well as the thermal performance of the H-bridge building block. In addition, the design and characterization of the 20-kHz three-port transformer are also given. Comprehensive experimental studies are conducted on a full-power prototype to verify the proposed design. With a measured 99.1% peak efficiency, the proposed TAB converter can fulfill the requirements for solar-plus-storage applications.

14 SOLAR ENERGY↗

Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

liquefaction↗

Assessing the Performance and Impact of PV Technologies on Storage in Hybrid Renewable Systems

Traditional monofacial photovoltaic (mPV) systems are commonly adopted and well-documented because of their lower upfront costs in comparison to bifacial photovoltaic (bPV) systems. This study investigates how PV technologies impact energy storage in grid-scale hybrid renewable systems, focusing on optimizing and assessing the performance of mPV and bPV technologies integrated with pumped storage hydropower. Using Ludington City, Michigan as a case study and analyzing real-world data such as solar irradiance, ambient temperature, and utility-scale load profiles, the research highlights the operational and economic benefits of bPV systems. The results reveal that bPV systems can pump approximately 10.38% more water annually to the upper reservoir while achieving a lower levelized cost of energy ($0.0578/kWh for bPV vs. $0.0672/kWh for mPV). This study underscores the outstanding potential of bPV systems in enhancing energy storage and management strategies, contributing to a more sustainable and resilient renewable energy future.

13 HYDRO ENERGY↗